소규모 업무용 건물의 외피 열성능에 따른 건축물 에너지효율등급 평가 연구 (Evaluation of the Energy Efficiency Rating in small office building according to the Thermal Performance of Building Envelope)

  • 김상아;홍원화;박효순
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.65-70
    • /
    • 2012
  • Each country has implemented various environmental policies to prevent natural disasters and destruction of ecosystem caused by global wanning. The republic of Korea also was performed building energy efficiency rating certification system as part of paradigm of 'Low carbon green growth' since 2010. However, the status on the building energy efficiency rating certification system has not been analyzed. In this study, We analyzed the elements affecting the energy efficiency of small office buildings focusing the status and certification cases of the building energy efficiency rating system. As a result, it is judged that thermal performance contribution of the building envelope is not high in the buildings certificated the first grade of the building energy efficiency rating system.

공동주택의 환기시스템별 에너지성능 비교 분석 (A Comparative Analysis of Energy Performance according to the Ventilation System in Apartment House)

  • 김길태;전주영;김선동
    • 토지주택연구
    • /
    • 제6권4호
    • /
    • pp.215-220
    • /
    • 2015
  • 본 연구는 공동주택에 적용되고 있는 환기장치를 선정하고 환기장치의 에너지특성 분석과 에너지저감을 목적으로 시뮬레이션 프로그램 (ECO2)을 이용하여 환기장치 별 에너지성능평가를 수행하였으며, 아래와 같이 결과를 도출하였다. 공동주택을 대상으로 환기장치 별 에너지 효율등급평가 기준에 따른 소비량을 수행하고자 하였다. 또한 단지별 에너지소비량과 비교 검토 결과를 통하여 현재 우리나라에서 공동주택에 적용하고 있는 환기장치별 에너지 소비량 실태를 파악하였다. 중부지방의 84type, 한 개동을 대상으로 시뮬레이션한 결과, 자연환기장치의 등급용 1차에너지소요량 값은 $159.9kWh/m^2yr$, 전열교환환기장치 $161kWh/m^2yr$, 바닥환기장치 $179.7kWh/m^2yr$로 계산 되었다. 위 시뮬레이션 결과를 공동주택의 실제 현장자료로 검증하였으며, 환기장치별 에너지소요량에 대한 비율로 비교해본 결과, 전열교환환기방식이 자연환기방식에 비해 -1~6% 적은 값을 보였으며, 바닥배관환기방식이 자연환기방식에 비해 약 10~20% 더 많은 1차에너지소요량이 나타났다. 환기장치의 팬동력과 열회수효율에 따라 에너지소요량의 난방과 환기 값이 변화하며, 향후 기계환기장치의 효율화 및 최적화가 필요하다고 판단된다.

건물에너지효율등급 평가도구와 상세해석프로그램의 비교 분석 (An Analysis of Comparison between the Evaluation Tool for Building Energy Efficiency Rating System and Detailed Analysis Programs)

  • 이재혁;유기형;조동우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.3-8
    • /
    • 2009
  • Since 2001, the Building Energy Efficiency Rating and Certification System have been implemented in Korea. For rating the energy efficiency performance, the evaluation tool for Building Energy Efficiency Rating System has been used. In this study, the evaluation tool was compared with detailed analysis programs(Trnsys 16, ESP-r) through simulations of heating energy needs for apartment, and we checked the character of the evaluation tool.

  • PDF

건물에너지효율등급 적용에 따른 초단열 슈퍼윈도우 열성능 평가 (A study on the Insulation Performance of the SuperWindow considering the Evaluation of Building Energy Rating)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제30권1호
    • /
    • pp.1-6
    • /
    • 2010
  • Generally, the building's windows and ventilation for the purpose of mining and the vista and windows by emotional engineering design area is a growing trend.In addition, the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is six times more than it through wall. Therefore, the purpose of this study is to evaluate the environmental performance of the super window system by verification experiment. The results of this study are as follows; 1) The insulation performance of super window system is $1.44\;W/m^2^{\circ}C$ 2) Super Window compared to a normal window reduce heating energy requirements have been 5.3% 3) Compared to a normal window, Super window savings rate was 4.1% lower 4) Building energy efficiency rating was up to 1 rating from 2 rating.

발코니 확장형 공동주택의 이중외피 창호 열성능에 따른 지역별 건축물에너지 효율등급 평가 (Study on the Evaluation of Regional Building Energy Efficiency Rating According to the Insulation Performance of Double Skin Window in Apartment Houses Expanded Balcony)

  • 장철용;안병립;김치훈;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.32-37
    • /
    • 2010
  • In order to handle the crisis about energy-environment problem, it is necessary to develop the future-oriented and innovative energy technology in architecture area. So the development of new technology for energy saving and alternative energy use has been spurred in this area. Double skin window system, which is an active covering to respond to the exterior change of the environment, is the skill that can reduce the indoor cooling and heating load and the environmental architecture can be realized. This study works out U-value of windows using the window-simulation program with the development and study of the double skin. In addition, the effect of the double skin insulation on the efficiency rating has been analyzed, applying to the certification system of the building energy efficiency rating which has implemented.

차폐계수와 창면적비에 따른 공동주택의 건물에너지효율등급 평가 (The Building Energy Efficiency Rating Evaluation of Apartment depending on SC and Window area ratio)

  • 장철용;한혜심;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제30권5호
    • /
    • pp.38-43
    • /
    • 2010
  • Enhancement of exterior's insulation performance like wall or window etc. is general way for building's energy efficient and thermal performance. But exterior's opening plan is important for minimizing the energy consumption and heat loss. In this paper, energy saving rate will be analyzed and compared considering the window area's rate and window's SC(Shading Coefficient) in a apartment with Building Energy Efficiency Rating System's evaluation tool. In the process of evaluation, energy saving rate is measured at each stage of the window area's rate from 20% to 60% every 10% term and the shading coefficient value from 1.0 to 0.6. As a result of this research, energy saving evaluation could not be measured exactly with existing evaluation tool. Accord this research, Building Energy Rating System's evaluation range is needed to be broaden for exact evaluation of energy saving rate.

지역에 따른 주거용 건물에너지효율등급 분석 연구 (A Study on the Analysis of Building Energy Rating considering the Region)

  • 안병립;김지훈;김지연;장철용
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.53-58
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

외피 열성능에 따른 건물에너지효율등급 분석 연구 (A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Building Envelope)

  • 김치훈;안병립;김지연;장철용
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.59-64
    • /
    • 2009
  • According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

창호 에너지 소비 효율 등급제와 건물 에너지 소비의 상관관계 분석 (Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption)

  • 곽희정;장향인;이현수;엄재용;서승직
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.338-345
    • /
    • 2013
  • The purpose of this study is to analyze the correlation between the 'Fenestration Energy Consumption Efficiency Rating System' (hereafter referred to as FECERS) and building energy consumption. 'EnergyPlus' was used for the calculation of energy consumption in apartments and office buildings, according to FECERS's rating and SHGC. The result indicates that the FECERS has high correlation with apartments, but has low correlation with office buildings. Also, it indicates that office buildings have a large impact from SHGC, which is not reflected in the FECERS. Consequently, the FECERS needs to be improved, by adding optical properties to assessment items. Additional study is required to establish the fenestration rating system, which, on the basis of this work, has high relevance to building energy consumption.

70 kW 이하 가정용 가스보일러 에너지소비효율 실험방법 개발 (A Development of Test Method on the Energy Consumption Efficiency of Domestic Gas Boiler below 70 kW)

  • 박찬일;김래현
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.73-82
    • /
    • 2016
  • 표시가스 소비량이 70 kW 이하인 가정용 가스보일러에 대하여 여러 가지 운전조건하의 에너지 소비효율 측정에 대해 고찰하였다. 실제 운전상태와 유사한 실험조건에서 행한 에너지 효율실험 결과를 국내의 효율등급표시 실험방법 결과와 비교 분석하였다. 실험에 사용된 가정용가스보일러는 일반보일러와 콘덴싱 보일러 각 1개씩이며, 각각의 보일러에 대하여 네 가지 조건으로 실험하였다. 실험종류를 구분하면 실험실 모드와 실제 가동모드로 나누고, 각각의 모드별로 최대가스소비량 상태와 소비자판매 상태로 나누어 적용하였다. 효율실험을 위해 사용하는 장비는 KS 표준과 유럽의 EN 규격 등 가스보일러 관련 규격에서 제시하는 실험장치의 기능을 다하면서, 여러 가지 측정 인자를 지속적으로 축적, 기록 및 저장할 수 있는 장치로 하였다. 측정 대상 인자들은 유량(가스, 물), 온도(실험실, 난방공급수, 난방환수, 배기가스), 압력(가스미터 내부, 가스보일러 입구, 대기압) 등이다. 위 네 가지 모드의 실험결과 에너지소비효율은 실험실 상태(보일러의 안정화 상태로 실험 시작)로 실험할 때가 실제 소비자가 사용하는 패턴으로 실험할 때 보다 일반보일러의 경우 약 10 %, 콘덴싱 보일러의 경우 약 20% 높은 소비효율로 측정되었다. 에너지소비효율등급을 부여하는 정부 고시의 효율실험방법도 본 연구에서 실시한 것과 같이 실제상황을 가정한 효율실험방법을 도입 운영할 필요가 있다.