• Title/Summary/Keyword: 에너지소산능력

Search Result 225, Processing Time 0.023 seconds

Displacement and Velocity Dependence of Clamped Shape Metallic Dampers (꺽쇠형 강재 댐퍼의 변위 및 속도 의존성)

  • Lee, Hyun Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.62-70
    • /
    • 2013
  • The purpose of this study is the displacement and velocity dependence evaluation of clamped shape metallic damper, which were evaluated superior in energy dissipation capacity than straight type slit damper. For this purpose, 6 metallic damper specimens are prepared and dependence test are performed. Test variables are displacement dependence and velocity dependence. According to displacement dependence test results, larger target displacement (50mm) shows lower cyclic numbers and cumulated energy dissipated area than lower target displacement (25mm). Also it shows higher strength and early failure than short target displacement. In velocity dependence evaluation, fast target velocity (60mm/sec) shows lower cyclic numbers and cumulated energy dissipated area than slow target velocity (40mm/sec). Therefore the hysteresis dependence of metallic damper were evaluated as close relation to the loading displacement and velocity conditions.

Experimental Study on the Cyclic Behavior of Modular Building with Strap Braced Load Bearing Steel Stud Walls (스트랩 브레이스를 갖는 내력벽식 모듈러건축 스틸스터드 벽체의 반복하중에 대한 거동 연구)

  • Lee, Doo Yong;Cho, Bong Ho;Kim, Tae Hyeong;Ha, Tae Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.415-425
    • /
    • 2016
  • Load-bearing steel stud wall system is widely used for the middle-to-high rise modular buildings worldwide. Seismic performance is a key issue to apply load-bearing steel stud wall system to modular buildings in Korea. This study proposes a new strap braced steel stud wall system with enhanced seismic performance and design equations considering the flexural behaviour of the vertical outer studs. For the verification, two specimens with different strap braces and vertical outer stud were designed and tested. The test results showed that the total strengths were evaluated to be 1.11 to 1.18 times higher than the predicted values. Usually strap braced walls are considered to have low energy dissipation capacities. The proposed system showed enhanced seismic performance with equivalent damping of 9.42% due to the reduced pinching effects.

Influence of the Random Yield Strength Distribution on the Behaviour Factor of Steel Structures (임의항복강도의 분포가 강구조물의 거동계수에 미치는 영향)

  • Kook, Seung Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.229-235
    • /
    • 1997
  • In order to check the influence of the randomness in yield strengths on the energy dissipation capacity of steel structures, behaviour factors applied for the "Response Spectrum Method" and their distributions are determined in this study with 7 steel framed models. Also 4 artificial accelerograms simulated with a given spectrum are applied to check the influence of the randomness in seismic action on the behviour factor. To execute numerous time-step calculations for the investigation a time-step analysis method is developed and applied after the reliability estimation to determine the action effects.

  • PDF

Displacement Dependency and Capacity Evaluation According to the Cross-Sectional Shape and Aspect Ratio of Steel Rod Dampers (강봉댐퍼의 단면형상과 형상비에 따른 변위의존성 및 성능 평가)

  • Hyun-Ho Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.5
    • /
    • pp.89-96
    • /
    • 2023
  • In this study, the displacement dependence, strength, and energy dissipation capacity of the steel rod damper were evaluated. The test variables were cross-sectional shape and aspect ratio. The 6th test specimens were made for performance test. From the test results, it was evaluated that the displacement dependence conditions of design code were satisfied in all specimens. And the strength effect according to the cross-sectional shape was minimal. As a result, the strength and energy dissipation capacity of the aspect ratio of 13.7 were evaluated as excellent.

Improvement and Evaluation of Seismic Performance of Flat Plate Slab-Column Joint Using High Ductile Fiber-Reinforced Mortar (고인성섬유 복합모르타르를 활용한 플랫 플레이트 슬래브-기둥 접합부의 내진성능 평가 및 개선)

  • Ha, Gee-Joo;Yi, Dong-Ryul
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.341-349
    • /
    • 2012
  • Recently, as structures in Korea and other countries become much taller, larger, and more specialized, concrete used for constructions of these structures is required to have high performance characteristics. Especially, seismic performance of concrete must be improved to resist cyclic loading from earthquakes. Consequently, this study was performed to focus on developing optimal mixtures of high ductile fiber reinforced mortar with high ductility and durability, which have good serviceability, stability and reliability performances. Eventually, this material is expected to improve seismic performance of concrete structures such as load carrying capacity, ductility capacity, and energy dissipation capacity when applied to critical regions of flat plate slab-column joint. Ultimately, this research is intended to develop a material for basic designs and practical constructions of reinforced concrete structures. Test results showed that the maximum load carrying capacity, the ductility capacity, and the energy dissipation capacity of the test specimens titled RCFPP series were increased by 15%~34%, by 33%~37%, and by 2.14 times, respectively, compared to those of the standard specimen titled SRCFP.

Failure Behavior of Non-seismic RC Column with aspect ratio of 4.0 (형상비 4.0인 비내진 철근콘크리트 기둥의 파괴거동)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.59-66
    • /
    • 2020
  • Two octagonal RC bridge columns of small scale model were tested under cyclic lateral load with constant axial load. One in two specimens was solid cross section, the other was hollow cross section. The volumetric ratio of transverse spiral hoop of all specimens is 0.00206. The columns showed flexure-shear failure. Failure behavior and seismic performance were investigated. The test results showed that the structural performance of the hollow specimen such as initial crack pattern, initial stiffness, and energy dissipation performance was comparable to that of the solid specimen, but the lateral strength, ultimate displacement, energy dissipation performance of hollow specimen noticeably decreased after drift ratio of 3%.

Experimental Test for Seismic Performance of PCS Structural System (PCS 구조 시스템의 내진 성능 분석)

  • Park, Soon-Kyu;Yeo, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.313-322
    • /
    • 2007
  • The PCS system, which consists of precast concrete column and steel beam, is a kind of composite structural systems. In this paper, experimental study has been conducted to analyze seismic performance of bolted beam-to-column connections for the PCS system. Based on experimental results from the seismic testing of eight interior PCS specimens, it shows that behavior of PCS system is satisfactory to seismic performance criteria of ACI such as strength deterioration, stiffness degradation and energy dissipation capacity except initial stiffness. All of the specimens maintain their strength at large levels of story drift without significant loss of stiffness and show high ductility level for inelastic behavior. The energy dissipation capacity is two times greater than requirement of ACI criterion. But the initial stiffness of all specimens does not satisfy ACI criterion, and this phenomenon is similar to the other composite structural systems such as RCS, CFT system.

Experimental Study on the Vibration Control Capacity of Hybrid Buckling-Restrained Braces (하이브리드 비좌굴가새의 진동제어능력에 관한 실험적 연구)

  • Kim, Do Hyun;Ju, Young Kyu;Kim, Myung Han;Sung, Woo Gi;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.83-91
    • /
    • 2009
  • Buckling Restrained Braces (BRBs) show good seismic behavior. They do not dissipate energy, however, when they are subjected to minor earthquakes or wind. Hybrid Buckling Restrained Braces (H-BRBs), which can improve the wind performance of the BRB system, are a kind of hybrid damper system composed of a viscoelastic damper and BRBs. In this paper, two H-BRB specimens with different cores were experimentally investigated to ensure the structural behavior of the H-BRB system in an elastic range. The axial deformation of the primary resisting system was compared with that of the secondary resisting system, and the equivalent damping ratio of the H-BRBs was estimated. It was concluded that H-BRBs with double shear dampers show good structural behavior and are applicable to tall buildings, to improve the building performance at a comfortable level.

Behavior of Reinforced Concrete Inclined Column-Beam Joints (철근콘크리트 경사기둥-보 접합부의 거동)

  • Kwon, Goo-Jung;Park, Jong-Wook;Yoon, Seok-Gwang;Kim, Tae-Jin;Lee, Jung-Yoon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.147-156
    • /
    • 2012
  • In recent years, many high-rise buildings have been constructed in irregular structural system with inclined columns, which may have effect on the structural behavior of beam-column joints. Since the external load leads to shear and flexural forces on the inclined columns in different way from those on the conventional vertical columns, failure mode, resistant strength, and ductility capacity of the inclined column-beam joints may be different than those of the perpendicular beam-column joints. In this study, six RC inclined beam-column joint specimens were tested. The main parameter of the specimens was the angle between axes of the column and beam (90, 67.5, and 45 degree). Test results indicated that the structural behavior of conventional perpendicular beam-column joint was different to that of the inclined beam-column joints, due to different loading conditions between inclined and perpendicular beam-column joints. Both upper and lower columns of perpendicular beam-column joints were subjected to compressive force, while the upper and lower columns of the inclined beam-column joints were subjected to tensile and compressive forces, respectively.

Earthquake Resistance of Beam-Column Connection of Precast Concrete U-Shaped Shell Construction (프리캐스트 콘크리트 U형 쉘 공법 보-기둥 접합부의 내진성능)

  • Im, Hyeong-Ju;Park, Hong-Gun;Eom, Tae-Sung;Kang, Su-Min
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.741-751
    • /
    • 2010
  • An experimental study was performed to investigate the earthquake resistance of the beam-column connections as a part of a precast concrete moment-resisting frame that uses precast concrete U-shaped shells for the beams. Five full-scale precast concrete specimens and one conventional monolithic concrete specimen were tested under cyclic loading. The parameters for this test were the reinforcement ratio, stirrup spacing, and end-strengthening details of the precast beam shell. The test results showed that regardless of the test parameters, the precast concrete beam-column connections showed good load-carrying capacity and deformation capacity, which were comparable to those of conventional monolithic concrete specimen. However, at large deformations, the beam-column connections of the precast concrete specimens were subjected to severe strength degradation due to diagonal shear cracks and the bond-slip of re-bars at the joint region. For this reason, the energy dissipation capacity and stiffness of the precast concrete specimens were significantly less than those of the cast-in-place specimen.