• Title/Summary/Keyword: 에너지성능평가

Search Result 1,877, Processing Time 0.028 seconds

The Study to Suggest a Methods to Evaluate Heating and Cooling Energy Performance based on Daily Life (실생활기반 냉난방에너지 성능평가 방법 제안 연구)

  • Jeon, Gangmin;Lee, Heangwoo;Kim, Yongseong
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.5 no.3
    • /
    • pp.291-299
    • /
    • 2015
  • With recent surge of attention to heating and air conditioning energy consumption, the need for evaluating performance of heating and air conditioning energy is also on the rise. This research aims to propose daily-life based evaluation method as an alternative to existing one, as well as to apply the method in real life to prove its validity. The results are as following. 1) I studied temperatures preferred by persons indoors and appropriate level of temperature, and the results show that properties of such persons such as age is directly linked with pleasantness of the room, but the issue lies with the fact that such properties are not considered in existing performance evaluation of heating and air conditioning. 2) Daily life based evaluation proposed herein reflects such properties of persons indoors. It controls heating / air conditioning devices installed in the test bed with the same size as a real life room to get quantitative and visual performances in our daily life as well as simple temperature information. 3) To verify validity of daily life based evaluation, I conducted different evaluation sessions with and without a blind and also based on ages of persons indoors. Results based on properties of persons showed difference of 77.6%, leading to effective analysis of energy consumption pattern by heating / air conditioning devices. This research takes significance in that it comes with a new performance evaluation method based on real life, and I gather that further studies are required to develop more multilateral performance evaluation in order to verify and improve technology for reduction of energy consumption.

건축물 에너지 소비량 성능평가 프로그램의 최근 기술동향

  • 윤종호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.31 no.4
    • /
    • pp.7-11
    • /
    • 2002
  • 최대부하 및 기간부하, 쾌적성능, 부분적 시스템 성능, 자연에너지 활용 시스템 등 건물의 종합적 에너지 성능을 평가하는 대표적 프로그램의 기술동향을 고찰한다.

  • PDF

태양광발전소 현장 진단평가 기술: 발전량 시뮬레이션과 다채널 I-V 장치를 통한 고장진단

  • Go, Seok-Hwan;Sin, U-Gyun;Sin, Ju-Yeong;Choe, Ui-Seong
    • Bulletin of the Korea Photovoltaic Society
    • /
    • v.7 no.2
    • /
    • pp.7-15
    • /
    • 2021
  • 태양광 발전소에 대한 성능을 평가하기 위해서는 IEC 61724-1에 적합한 계측장치를 설치하고 데이터를 수집하여 평가하는 것이 일반적인 방법이다. 본 논문에서는 태양광발전소 현장에서 DC 어레이 성능을 평가하기 위한 방법을 제시하였다. 측정 일사량과 같은 환경정보 값과 태양광 DC 어레이 전압-전류 특성 곡선을 이용해 일사량에 따른 출력모델 식을 도출하였다. 도출된 모델 식은 태양전지 셀의 종류나 버스바에 따라서 차이가 발생되므로 기존의 태양전지 셀 등가회로 수식을 반영한 시뮬레이션 모델식이 적절히 변경되어야 함을 실험을 통해 검증하였다. 주기적인 진단 평가를 실시하지 않는 국내외 태양광 발전소는 성능저하가 발생된 상태로 운전되는 경우가 다수 일 것이다. 대부분의 관제모니터링을 시스템은 미쓰매칭 손실 평가분석이 불가능하며 운전상태 모니터링 하는 시스템이 대부분이다. 이에 태양광 발전소의 효율적 운영을 위해서는 현장진단 장치를 이용한 주기적 성능진단 평가나 발전소 데이터의 손실평가 분석 기술의 개발이 필요할 것이다.

Evaluation on the Performance of Power Generation of Energy Harvesting Blocks for Urban and Housing Application (도시·주택 적용 미관용 에너지 블록의 발전성능 평가)

  • Noh, Myung-Hyun;Kim, Hyo-Jin;Park, Ji-Young;Lee, Sang-Youl;Cho, Young-Bong
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.187-193
    • /
    • 2012
  • A technology that newly attract attention in the area of energy-related study is the energy harvesting(or scavenging) technology. In this paper, the performance of power generation for the energy harvesting block with a combination of piezoelectric technology and electromagnetic technology among various energy harvesting technologies was investigated. The goal of this study is to evaluate on the applicability of our developed energy harvesting block into the field of urban & housing. First, we evaluated the performance of power generation for the multi-layer energy harvester at laboratory scale. Second, we described the features of our developed prototype module that includes amplification technologies to improve power density per module and evaluated the performance of power generation for the energy harvesting block in a variety of ways. From the test results, the developed product increased the performance of power generation up to 255% or 505% compared to the existing product and its superiority were shown. Finally, we suggested the direction for the improvement of the energy harvesting block module.

A Study on the Energy Performance Evaluation of Building Evaporative Cooling System for Building Construction in Response to Climate Change (기후변화 대응 저에너지 건축물 조성을 위한 건축물 기화냉각시스템 에너지성능평가 연구)

  • Kwon, Ki-Uk
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.1
    • /
    • pp.54-60
    • /
    • 2019
  • The recent climate change is exacerbating the external thermal environment and increasing the amount of energy used in building. Energy Plus was used to evaluate low energy technology performance of buildings responding to climate change. The test types of basic building(control) and evaporative mist system + basic building(EMS), and the analysis results of each type are compared. Energy performance evaluation result, Cooling peak load were EMS reduction compared to control is about 9%. Annual cooling load per unit area were EMS reduction compared to control is about 17%. Annual energy use per unit area were EMS reduction compared to control is about 10%. Therefore, the effect of the evaporative cooling system is considered to be good through energy reduction technology of building, according to the amount and distance of the evaporative mist system in the future research on building energy performance evaluation should be carried out.

건물에너지 성능평가를 위한 표준기상자료의 국내외 현황

  • 윤종호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.8
    • /
    • pp.7-14
    • /
    • 2003
  • 건물에너지 성능평가 결과의 신뢰성 검증을 위해 가장 먼저 확인하는 요소 중의 하나가 어떠한 기상데이터를 적용했는가일 것이다. 아쉽게도 국내의 경우 아직까지 공인된 표준기상자료가 확립되어 있지 못한 실정이며, 이로 인해 다양한 프로그램을 통한 해석결과의 객관성 확립에 많은 어려움을 겪고 있다. 본 고에서는 건물에너지 성능평가를 위한 시간별 기상자료를 대상으로 국외 및 국내의 개발현황을 고찰하고, 향후 개선방향을 제안하고자 한다.

  • PDF

Evaluation of Pulmonary Nodules filter on energy subtraction X-ray Images (에너지 차분 흉부 X선 화상에 있어서 폐종류 음영 필터의 평가)

  • 김응규
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10b
    • /
    • pp.386-388
    • /
    • 2000
  • 에너지 차분 흉부 단순 X선 화상으로부터 폐종류 음영을 검출하기 위한 필터를 예측해서 그 성능을 평가하기 위한 방법을 제안한다. 더욱이 그 평가방법을 이용해서 기존에 제안된 필터인 다중 해상도 ▽2G 필터의 평가를 행한다. 방사선과 전문의의 진단보조 혹은 총합자동진단시스템의 구성요소로서 필터가 발휘한 역할을 고려한 후, 필터가 만족해야 할 조건 및 그 조건을 만족한 경우에 있어서 몇가지 성능평가 척도를 명확히 한다. 제안한 평가방법을 통해서 다중 해상도 필터가 단일 해상도 필터에 비해 높은 성능을 나타내고 있음을 명확히 한다.

  • PDF

Evaluation of Power Generation of Hybrid Energy Harvesting Blocks applying the Piezoelectric Effects and Electromagnetic Induction Principle (압전 및 전자기 유도 기술을 적용한 하이브리드 에너지수확 블록의 발전량 평가)

  • Noh, Myung-Hyun;Lee, Sang-Youl
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.734-737
    • /
    • 2012
  • 에너지하비스팅이란 도시와 자연 환경 속에 상시 존재하지만 진동, 열, 빛 등과 같이 버려지는 에너지 소스로부터 전기를 수확하는 것으로 대용량 발전소와는 다른 신개념의 전기 수확 기술이다. 본 연구에서는 다양한 에너지 하비스팅 기술들 중에서 압전 원리와 전자기 유도 방식을 조합한 하이브리드 에너지 하비스팅 블록에 대한 발전량을 평가하여 에너지 하비스팅 블록의 주택 도시 분야 적용 가능성을 검토하고자 하였다. 이를 위해 랩스케일 PZT 기반 다층 에너지 하베스터의 현 발전량을 평가하여 제시하였고, 증폭기술을 적용하여 개발된 에너지 블록의 발전성능을 다각적으로 평가하여 제시하였다. 또한 개발된 에너지 블록과 기존 상용 제품과의 발전성능 비교 실험을 수행하여 개발된 에너지 블록의 우수성을 입증하였다.

  • PDF

Performance Evaluation of Pulmonary Nodules Detection Filter from X-ray Images (흉부 X선 화상으로부터 폐종류 음영 검출 필터의 평가)

  • 김응규
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.133-136
    • /
    • 2000
  • 에너지 차분 흥부 X선 화상으로부터 폐종류 음영을 검출하기 위한 필터를 예측해서 전문의의 진단보조 혹은 총합자동진단시스템의 구성 요소로서 필터가 발휘한 역할을 고려한 후, 구체적인 성능 평가 방법을 제안한다. 필터의 성능을 평가할 때 문턱값을 변화시킨 경우, 못보고 빠트린 비율과 잘못 본 비율의 변화를 ROC 곡선으로 나타내어 이것에 기초한 판단을 행하는 접근방법이 있다. 본 연구에서는 이와같은 평가에 대한 구체적인 예를 통하여 문제점을 명확히 하여 그 평가기준을 마련한다. 성능 평가를 행하기 위해 이용된 에너지 차분화상으로서, 임상 데이터 14개의 증예를 이용한다. 즉, 총 종류수 32개 한 개의 증예에 있어서 종류의 개수는 1~8개로 평균 2개, 1mm 당 샘플링 간격 5 픽셀, 비트 분해능 10 bit의 저압화상으로, 그 크기는 1760$\times$1760이다. 계산기 하드웨어의 제약으로부터 원화상을 가우스 함수로 평활화 해서 1/8로 축소한 화상으로 실험을 행한다. 상기 평가 절차에 따라, 이전에 개발된 다중해상도 ∇$^2$G 필터의 성능을 평가하고, 단일해상도 ∇$^2$G 필터와의 비교를 통해 그 성능이 우수함을 확인한다. 본 평가 방법은 화상진단 지원용 필터의 평가에 대해서 적용될 수 있을 것이다.

  • PDF

An Evaluation of Airtightness Performance and Analysis of Energy Savings Potential in Apartment Housing (공동주택의 기밀성능 평가 및 에너지 절감효과 분석)

  • Leigh, Seung-Bok
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.119-125
    • /
    • 1995
  • Since the using of heating energy associated with infiltration is significant in a building, the efforts to minimize the infiltration while ensuring minimum ventilation rates for various types of occupancy will be beneficial. In constrast to that many efforts have been made to reduce heat loss by improving thermal resistance of building envelope, little has been tried to reduce heat loss from infiltration. For achieving such an objective, measurement of air leakage rate will be pre-requisite as a diagnostic tool. A blower door system, a depressurization/pressurization method, was employed and it demonstrated a good potential for measuring airtightness performance of residential buildings. Based on the test results, annual energy savings for residential heating was estimated by reducing infiltration to a level of reasonably airtight or to a level of ASHRAE Standard 62-1989 for minimum ventilation.

  • PDF