• Title/Summary/Keyword: 에너지관제

Search Result 29, Processing Time 0.027 seconds

A New LED Light Device Lighting Control Algorithm for Optimal Energy Saving (최적의 에너지 효율을 위한 새로운 LED 조명기기 점등제어 알고리즘)

  • In, Chi-Goog;Hong, Sung-Il;Chang, Jeong-Uk;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.17-23
    • /
    • 2012
  • In this paper, we were proposed a new LED light device lighting control algorithm for optimal energy saving. The propose lighting control algorithm be to the LED lights devices lighting control by measuring illuminance into multi sensors. And it be to lighting control by inverting of octagon pattern during set-up time. All the LED is lighting when detecting motion by the motion sensor. And, it was designed enable remote management control by communicate with central monitoring center using Zigbee wireless network to measured data from sensors at real time. In this paper, a proposed lighting control algorithm was measured power consumption about the lighting status of LED lighting device using the lighting control program for demonstrate of energy savings effect. The measured result, the lighting method applying proposed algorithm were proved energy savings effect of more 40% more compared to the existing lighting method.

A Study on the Energy Absorption Capacity of Collision and Corner Posts of EMU according to APTA SS-C&S-034-99 Standard (미국 규격에 따른 전두부 충돌에너지 흡수 요구조건의 해석적 평가)

  • Jeong, Ji-Ho;Lee, Jan-Wook;Park, Gun-Soo;Woo, Kwan-Je
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.289-294
    • /
    • 2011
  • The purpose of this paper is to validate energy absorbing capacity that satisfies APTA SS-C&S-034-99, REV.2 with North America type Electric Multiple Units. The FE models for collision and corner post simulation were developed. Two type of simulation were conducted. One is quasi-static analysis for collision post and the other is quasi-static analysis for corner post. And the energy absorption capacity of the analytical model was verified.

  • PDF

VLCC기항에 따른 인천VTS 안전대책

  • Lee, Seong-Yong;Jang, Jae-Yeong;Choe, Ja-Yun;Lee, Chang-U;Park, Hyeon-Ji
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.06a
    • /
    • pp.316-318
    • /
    • 2014
  • VLCC에 의한 SK에너지 울산CLX와 인천CLX의 일원화된 효율적 원유 수급체계에 따른 물류비용의 절감, 이에 따른 국가 산업 경쟁력확보 및 항만경쟁력 강화를 위한 고도화 사업의 일환으로 고부가가치 선박인 VLCC가 인천항에 처녀입항하게 되었다. 이로 인한 해상교통관제센터(VTS)의 안전대책이 요구되어 비교적 통항량이 많고 항로길이가 긴 인천항의 VLCC운항 계획에 따른 해상교통 혼잡도 등, 다각적인 통항 안전성 및 VLCC 입출항에 따른 타 통항선과의 항행안전 관계등을 점검하여, 계속적인 VLCC 입항에 따른 항행 위험성을 파악하고, 앞으로의 인천항만 안전을 위한 통항안전관리대책을 모색하고자 한다.

  • PDF

Architecture Study for SDDC BAS (SDDC BAS의 아키텍처에 관한 연구)

  • Kim, Jeong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.646-651
    • /
    • 2015
  • In this paper, we analyze the architecture of a typical building automation systems and control points in the network architecture, interoperability, and performance aspects. We proposed a new virtualization-based point-to-point automatic control system that is connected to a high speed wired system. Cloud computing based automation system enables the user based environment control, and may perform a building energy management performance through the improvement of the building automation system efficiently In addition, the virtualization system makes it possible to perform the management of the group building load management operators efficiently.

A Numerical Study on the Shock Behavior of Multi-layered Panels (다층 패널의 피탄충격거동에 관한 수치해석적 연구)

  • Park, Chan-Young;Yang, Hong-Jun;Lee, Kyoung-Hoon;Woo, Kwan-Je;Koo, Man-Hoi;Joo, Jae-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.986-992
    • /
    • 2011
  • In this paper, the characteristics of shock behavior of multi-layered panels under impact were studied. The panels consist of four different lightweight materials including al, al-foam, rubber and FRP in order to enhance their shock energy absorption. A commercial code, Ls-dyna was used to build the numerical model and study shock behavior based on the analysis of shock response spectrum and peak response acceleration. The reliability of the numerical model was estimated by its comparison with the experimental results acquired under the same impact conditions.

Energy Absorption of Collision Post Based on North American CFR Regulations for Railway Vehicles (철도차량의 북미 CFR 법규에 대한 충돌 기둥에너지 흡수에 관한 연구)

  • Kim, Seung-Tech;Jeong, Ji-Ho;Choi, Jeong-Yong;Woo, Kwan-Je
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.8
    • /
    • pp.935-943
    • /
    • 2012
  • In accidents involving the collision of railway vehicles, there is a risk that structural members might penetrate the cab frame of the railway vehicle in the space in which the driver or passengers are seated. To reduce this risk, worldwide, studies on the collision of railway vehicles are underway. In North America, the Code of Federal Regulations (CFR) was revised in 2010 to include crush criteria for a collision and the corner post in an end frame. In this study, a crush analysis and crush test for a collision post and a crash analysis for a rigid cylinder were performed according to the CFR. The analysis and test results were compared and reviewed. This study aims to determine the usefulness of crush analysis for developing various end frames, and to understand the crush and crash characteristics and review the accuracy of the analysis.

A Pre-Feasibility Test of Introducing Renewable Energy Hybrid Systems -Case Studies for 3 Off-Grid Islands- (도서지역 신·재생복합 전력시스템 보급 타당성 분석 -3개 도서지역 분석결과-)

  • Jang, HaNa;Kim, Suduk
    • Environmental and Resource Economics Review
    • /
    • v.15 no.4
    • /
    • pp.693-712
    • /
    • 2006
  • A pre-feasibility test is done for renewable energy hybrid power systems at off~grid islands in which the current power supply is provided only by diesel generation. We apply Homer (Hybrid Optimization Model for Electric Renewables) which was developed by the National Renewable Energy Laboratory (NREL) for the analysis to identify the cost-minimizing combination of power generating facilities for the given load profiles. Chuja-Do, Geomun-Do and Youngsan-Do have been selected for our analysis considering the wind resources data of the Korea Institute of Energy Research (KIER). Information on wind speed, solar radiation and temperature is also used for the analysis. System component cost information from overseas market has been used due to the lack of domestic information. Site specific Load profile for electricity demand for those islands are reconstructed based on the partial survey results obtained form other sources. The LCOE of the least cost hybrid power systems for Chuja-Do, Geomun-Do and Youngsan-Do are $0.278/kWh, $0.234/kWh and $0.353/kWh, respectively Considering the fact that diesel generation is being subsidized at the price of $0.300/kWh by the government, first 2 cases are economically feasible for the introduction of renewable energy hybrid systems to those islands. But the third case of Youngsan-Do does not meet the criteria. The basic differences of these pre-feasibility test results are from the differences of the site specific renewable energy conditions, especially wind resources. In summary, promoting hybrid systems in the off-grid remote island should be based on the economic feasibility test results. Not all the off-grid islands are feasible for introducing this renewable energy hybrid system.

  • PDF

Development of a System for Field-data Collection Transmission and Monitoring based on Low Power Wide Area Network (저전력 광역통신망 기반 현장데이터 수집 전송 및 모니터링 시스템 개발)

  • Yeong-Tae, Ju;Jong-Sil, Kim;Eung-Kon, Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.6
    • /
    • pp.1105-1112
    • /
    • 2022
  • Field data monitoring systems such as renewable energy generation and smart farm integrated control are developing from PC and server to mobile first, and various wireless communication and application services have emerged with the development of IoT technology. Low-power wide-area networks are services optimized for low-power, low-capacity, and low-speed data transmission, and data collected in the field is transmitted to designated storage servers or cloud-based data platforms, enabling data monitoring. In this paper, we implement an IoT repeater that collects field data with a single device and transmits it to a wireless carrier cloud data flat using a low-power wide-area network, and a monitoring app using it. Using this, the system configuration is simpler, the cost of deployment and operation is lower, and effective data accumulation is possible.

Study on Remote control and monitoring system of the multipurpose guard rail using USN (USN을 이용한 다목적 가드레일의 원격제어 및 모니터링 시스템에 관한 연구)

  • Song, Je-Ho;Lee, In-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7176-7181
    • /
    • 2015
  • This thesis is about the system where the solar module is attached to the high functional guardrail posts with anti-weed, anti-plant, and road-kill applied to produce internal power, enabling the integrated control and real-time monitoring of appearance of wildlife and road conditions using the USN. The whole system consists of a photovoltaic module(PV), a detection sensor(pyroelectric), a controller(operation select and motion sensor), the USN system, the DB(sound and flash), an output unit of sound and flash, and the control system of road-kill prevention and safety induction for vehicles. Thus this study aims to address the remote control and monitoring system of multipurpose guardrails to improve road environment, prevent road-kills, protect wild animals, and guide cars safely by using the USN which is combined with new renewable energy and IT convergence technology. As a result of the study on the remote control and monitoring system using the USN, it was ascertained that the response time of the unmanned sensing system was within 5.1 ms with the current consumption of 0.328 mA, and the data transmission speed of the remote control system was 250 kbps with the current consumption of 0.283 mA.