• 제목/요약/키워드: 업무용 건축물

검색결과 47건 처리시간 0.027초

소규모 업무용 건물의 외피 열성능에 따른 건축물 에너지효율등급 평가 연구 (Evaluation of the Energy Efficiency Rating in small office building according to the Thermal Performance of Building Envelope)

  • 김상아;홍원화;박효순
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.65-70
    • /
    • 2012
  • Each country has implemented various environmental policies to prevent natural disasters and destruction of ecosystem caused by global wanning. The republic of Korea also was performed building energy efficiency rating certification system as part of paradigm of 'Low carbon green growth' since 2010. However, the status on the building energy efficiency rating certification system has not been analyzed. In this study, We analyzed the elements affecting the energy efficiency of small office buildings focusing the status and certification cases of the building energy efficiency rating system. As a result, it is judged that thermal performance contribution of the building envelope is not high in the buildings certificated the first grade of the building energy efficiency rating system.

컴퓨터프로그램을 이용한 엘리베이터 피난 연구 (Elevator evacuation studies using a computer program)

  • 차종호
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5525-5533
    • /
    • 2012
  • 최근의 건축물은 초고층화 또는 지하 공간의 심층화되어감에 따라 과도한 수직 거리 이동으로 인하여 체력이 부족한 사람들이 피난층 비상구에 이르기 전에 지쳐서 쓰러질 가능성이 있다. 화재 발생 인접 구역으로부터의 초기 피난에는 계단을 사용한 후에 나머지 거리는 승강기를 이용하여 안전한 공지나 도로로 탈출하는 방법을 요구하고 있다. 이에 따라 서울특별시 초고층 건축물 가이드 라인에서 피난용승강기에 대해 제정되었다. 최근 층수는 지하 7층 지상53층, 바닥면적 $6,800m^2$ 연면적 $127,050m^2$, 용도는 문화 및 집회시설 판매시설 업무시설 숙박시설(호텔) 공동주택(아파트)의 건축물을 설계하면서 피난용승강기를 별도로 설치하기에는 효율적이지 못하다는 판단하에 승용승강기의 설치기준에 따라 설계된 승강기를 피난용으로 사용하기로 결정하였다. 그러나 이에 대한 세부 설계지침내용이 아직까지 마련되어 있지 않아 국내법과 해외 설치기준을 근거로 승용승강기를 피난용으로 이용하기 위한 설계방법을 정리하였으며, 실제 설계된 도면으로 ELVAC+와 PathFinder의 피난프로그램으로 승강기수와 승강기를 이용한 피난자수의 적정성에 대해 연구하였다.

분양건축물에 대한 감리제도 개선 방안 (Construction Supervision Improvement Methodology of Public Installment Buildings)

  • 부승현;류한국;이현수
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2003년도 학술대회지
    • /
    • pp.365-368
    • /
    • 2003
  • 건축법에 의한 감리제도가 1963년 도입된 이후 건축물은 용도, 성능 및 규모 등의 측면에서 더욱 다양해지고 복잡해졌다. 공공부문에서는 1994년에 건설기술관리법 개정을 통해 책임감리제도를 도입하였고, 민간부문 중 공동주택의 부실 공사를 방지하고자 주택건설촉진법을 개정하여 공사감리제도를 강화하는 등 공사관리의 효율성과 품질의 향상을 가져왔다. 또한 최근에는 주상복합건축물과 다중이용건축물이 도입되면서 여러 형태적${\cdot}$사회적 요구에 따른 제도적 변화가 지속되어 왔다. 정부가 주택시장 안정을 위해 300세대 이상의 주택을 건설하는 경우 해당 주상복합건축물에 대해 주택 건설촉진법에 의해 적용받도록 법령을 개정하였다. 그러나 이러한 개정사항은 감리대상 건축물 중 일부에 한정되어 있어 공사를 효율적으로 감리하기에는 미흡하며, 독립적인 감리업무를 수행하는데 여러가지 어려움이 있다. 이에 본 연구는 분양건축물을 중심으로 감리제도의 현행 문제점을 검토하고 그에 따른 개선방안을 제시하고자 한다.

  • PDF

국내 친환경 업무용 건축물의 디자인에 대한 비교 연구 (A Comparative Analysis of Designs in Low Carbon Environment-Friendly Business Buildings)

  • 강연주;김문덕
    • 한국실내디자인학회논문집
    • /
    • 제23권3호
    • /
    • pp.153-163
    • /
    • 2014
  • The eco-friendly elements are important for new construction and renovation and redevelopment of the buildings. The green buildings are related with minimizing environmental pollution and how to live with nature throughout the entire process of demolishing and building. The purpose of this paper is to study on eco-friendly business buildings in the trend of mandatory green building certification system. The analysis of this paper is comparative studies on practices at eleven domestic eco-friendly business buildings through site survey on design framework of green buildings. The design framework of eleven this buildings is six kinds of skills on technical, renewable, ecological, cultural, healthy, social. The eleven this buildings in the new & renewable energy and IT technology of technical sector are satisfied with the framework. But, domestic most advanced eco-friendly business buildings are placed difference between almost the two times on the lower buildings at comparative evaluation. The three of this buildings are gratified rainwater harvesting and waste recycling systems for renewable and recycle. The buildings have an excellent aspects of technology and ecology. The benefits of this buildings are related with future compulsory zero energy house to take technical advantage of renewable energy. However, the buildings reflecting the regional culture types is insufficient. The buildings should be supplemented as follows. This buildings are need to have the social enhancement programs and design for convenient space of community residents, through health and comfort of on workplace. Moreover, this buildings have features of coexisting with human beings and nature friendly with the aim of realizing the sustainable development. The social enhancement programs through regional cultural aspects with ecology are related with individual and community livings in harmony, non-hierarchical communal lifes. The development of the cultural aspects provide for consensus about the local community and creating sustainable communities. Thus, The buildings are to have energy saving, pleasant and healthy living environment and interactive individual and community livings in harmony.

아파트 단지의 로봇 친화형 환경 인증 모델 개발 (Development of Certification Model of Robot-Friendly Environment for Apartment Complexes)

  • 정민승;장설화;구한민;윤동근;김갑성
    • 지적과 국토정보
    • /
    • 제53권1호
    • /
    • pp.83-105
    • /
    • 2023
  • 최근 서비스 로봇을 일반 건축물에 도입하는 사례가 늘어나고 있다. 이에 2022년 로봇 친화형 건축물 인증제도가 구축되었으나, 업무용 건축물로 대상을 한정하여 적용 가능한 건축물이 많지 않았다. 본 연구에서는 기존 로봇 친화형 건축물 인증제도를 아파트 단지로 확장한 로봇 친화형 환경 인증 모델을 개발하였다. 초점집단면접과 분석적 계층화 과정을 통하여 지표를 구축한 결과, 총점 176점으로 구성된 지표의 분야별 중요도는 건축 및 시설 설계, 네트워크 및 시스템, 건축 운영 관리, 로봇 지원 및 기타 서비스 순으로 나타났다. 개별 항목의 점수들은 분야 간 중요도, 분야 내 중요도를 반영하자 1점에서 18점으로 다양하게 산출되었다. 28개의 개별 항목에 대한 점수를 합한 총점에 따라 아파트 단지에 최우수, 우수, 일반 인증 등급을 부여할 수 있다. 본 연구는 인간-로봇의 상호작용을 고려한 아파트 단지의 로봇 친화형 환경 인증 모델을 세계 최초로 개발하였다는 데 의의가 있다.

업무용 건축물의 기계소방시설 배관 부속자재 요율 제시 (Suggestion of the Attached Piping Material Rate for the Mechanical Fire Protection Facilities in Office Buildings)

  • 박률;박경순;윤항묵
    • 대한건축학회연합논문집
    • /
    • 제20권6호
    • /
    • pp.1-8
    • /
    • 2018
  • In generally, the estimation work regarding building mechanical service system in comparison with other architectural estimations is time-consuming, and the process is continuously getting more difficult because of the increased usage of the attached piping materials such as fittings and supports in addition to their complicated construction processes. In order to improve this problem, the Korean authority provides a simple method to estimate the attached material rate regarding the main piping material, which is the most time-consuming work in the architectural mechanical estimation. However, to be an applicable method on construction site, a proper conversion rate of the attached piping material is still required for the proposed method regarding building usage and working types. Therefore, the purpose of this research is the suggestion of the material and labor cost rate of the attached piping materials such as the fittings and supports by work types and fitting methods of indoor fire, sprinkler, and extinguishing gas piping work of mechanical fire protection facilities in office buildings that have been designed after 2010.

친환경 특성이 오피스 빌딩 가격에 미치는 영향 (The Effect of Eco-friendly Characteristics on the Price of Office Buildings)

  • 소성규;조주현
    • 부동산연구
    • /
    • 제28권2호
    • /
    • pp.49-64
    • /
    • 2018
  • 본 연구는 서울시 오피스 건물을 대상으로 친환경 건축물 인증등급이 오피스의 가격과 비용에 미치는 영향을 분석하였다. 이를 위해 건축물들의 매매가격을 다중회귀 분석을 통해 규명하였다. 또한 친환경 인증등급이 높은 경우에 어느 정도의 환경부하비용이 저감되는지를 분석하기 위해 LCC(Life Cycle Cost) + LCA(Life Cycle Assessment) 분석을 실시하였다. 실증분석 결과, 친환경 인증등급이 높을수록 업무용 오피스 가격에 유의한 양의 영향을 준 것으로 나타났다. 또한 LCC 분석에서는, 친환경 인증등급을 높게 받은 건물이 그렇지 않은 건물보다 적은 생애비용이 드는 것으로 나타났다. 또한 친환경 인증등급을 높게 받은 오피스 건물이 그렇지 않은 건물보다 환경부하비용(LCA)이 적게 든다는 것을 확인하였다. LCC와 LCA를 통합한 TCA 분석에서는 친환경 인증등급을 높게 받은 건물이 그렇지 않은 건물보다 적은 사회적 총비용을 나타냈다.

건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구 (A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings)

  • 정영선;정해권;장희경;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

국내 중규모 업무용 건물의 녹색건축인증 등급별 추가공사 비용 영향에 관한 연구 - G-SEED 2016-2 기준으로(2018년 9월 1일 시행) - (A Study on the Cost Impact of Additional Construction as Rating G-SEED Certification of Medium-Sized Office Buildings in Korea - Based on G-SEED 2016-2(Effective September 1, 2018) -)

  • 이두환;김재문
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.225-234
    • /
    • 2019
  • The purpose of this paper is to analyze the additional construction cost of G-SEED certification for domestic office building reflecting the latest standard(G-SEED 2016-2), and to derive cost impact by category and level. Therefore, it is intended to provide quantitave cost data according to G-SEED certification at the planning phase of the project, estimate the additional construction cost per level according to G-SEED Certification of similar project to be carried out in the future, and encourage G-SEED certification by supporting the decision of the owners. Method: The Process and method of this study are summarized in five steps, 1) Review of previous research, 2) Selection of target project, 3) Scenario setting by level, 4) Additional construction cost for each evaluation category, 5) Extraction of additional construction cost ratio by level. Result: This paper analyzed the cost impact by deriving the additional construction cost of detailed category for level improvement according to the revised G-SEED certification(G-SEED 2016-2). In conclusion, an additional construction cost(ratio) of G-SEED projects to the reference building is drawn as good level; 157,426,241 KWN(+0.43%), very good level; 321,907,802 KWN(+0.88%), excellent level; 999,371,478 KWN(+2.74%), and outstanding level; 1,467,047,718 KWN(+4.02%).

업무용 빌딩의 피난 성능 검토에 관한 연구 (A Study on the Evacuation Performance Review for the Office Buildings)

  • 오혁진;백승태;김우석;이수경
    • 한국화재소방학회논문지
    • /
    • 제17권3호
    • /
    • pp.1-6
    • /
    • 2003
  • 본 연구에서는 특정의 업무용 건축물에 대해서 화재 및 피난 시나리오를 선정하여 FAST 3.1.7(전실화재 예측), SIMULEX 32-bit(피난시간의 예측), JASMINE 3.25d(특정시간까지의 연기 유동성 평가)등의 S/W를 이용하여 이를 평가했으며 그 결과는 다음과 같다. Scenario #1 결과, 화재실에서 전실화재가 발생하지 않았고, 층 피난시간은 25.2 sec로 나타났으며 이때까지의 FAST 3.1.7결과에서 연기층은 2.4m를 기록, 연기유동성 평가에서도 재실자들은 연기의 피해(가시거리, 독성)없이 피난이 완료될 것으로 나타났다. Scenario #2 결과, 화재실에서 6 min 33.2 sec에 전실화재가 발생했으며, 수계산에 의한 피난시간은 5 min 23sec로 나타났다. 본 대상건물에 대해서 선정한 Scenario #1, #2 모두 인명안전설계는 적정하게 설계되었다고 판단된다.