• Title/Summary/Keyword: 양자잡음

Search Result 197, Processing Time 0.024 seconds

Evaluation of the Performance Characteristic for Mammography by Using Edge device (유방영상에서 엣지를 이용한 물리적 영상 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Lee, Eul-Kyu;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.415-420
    • /
    • 2016
  • The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of elenia demensions tomo and lorad selenia mammography were maintained at $10mm^{-1}$ and NPS and DQE including the low nyquist frequency indicated to $6.0mm^{-1}$. Therefore, regulary QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.

Performance Characteristic of a CsI(Tl) Flat Panel Detector Radiography System (CsI(TI) Indirect Flat Panel Detector의 선질에 따른 물리적 영상 평가)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Kim, Jung-Min;Park, Min-Seok;Lee, Gaung-Young
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.109-117
    • /
    • 2012
  • The purpose of this work was to evaluate an amorphous silicon cesium iodide based indirect flat-panel detector (FPD) in terms of their modulation transfer function (MTF), Wiener spectrum (WS, or noise power spectrum, NPS), and detective quantum efficiency (DQE). Measurements were made on flat-panel detector using the International Electrotechnical Commission (IEC) defined RQA3, RQA5, RQA7, and RQA9 radiographic technique. The MTFs of the systems were measured using an edge method. The WS(NPS) of the systems were determined for a range of exposure levels by two-dimensional (2D). Fourier analysis of uniformly exposed radiographs. The DQEs were assessed from the measured MTF, WS(NPS), exposure, and estimated ideal signal-to-noise ratios. Characteristic curve in the RQA3 showed difference in the characteristic curve from RQA5, RQA7, RQA9. MTFs were not differences according to x-ray beam quality. WS(NPS) was reduced with increasing dose, and RQA 3, RQA5, RQA7, RQA9 as the order is reduced. DQE represented the best in the 1mR, RQA 3, RQA5, RQA7, RQA9 decrease in the order. The physical imaging characteristics of FPD may also differ from input beam quality. This study gives an initial motivation that the physical imaging characteristics of FPD is an important issue for the right use of digital radiography system.

A Study on the Establishment of Entropy Source Model Using Quantum Characteristic-Based Chips (양자 특성 기반 칩을 활용한 엔트로피 소스 모델 수립 방법에 관한 연구)

  • Kim, Dae-Hyung;Kim, Jubin;Ji, Dong-Hwa
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.140-142
    • /
    • 2021
  • Mobile communication technology after 5th generation requires high speed, hyper-connection, and low latency communication. In order to meet technical requirements for secure hyper-connectivity, low-spec IoT devices that are considered the end of IoT services must also be able to provide the same level of security as high-spec servers. For the purpose of performing these security functions, it is required for cryptographic keys to have the necessary degree of stability in cryptographic algorithms. Cryptographic keys are usually generated from cryptographic random number generators. At this time, good noise sources are needed to generate random numbers, and hardware random number generators such as TRNG are used because it is difficult for the low-spec device environment to obtain sufficient noise sources. In this paper we used the chip which is based on quantum characteristics where the decay of radioactive isotopes is unpredictable, and we presented a variety of methods (TRNG) obtaining an entropy source in the form of binary-bit series. In addition, we conducted the NIST SP 800-90B test for the entropy of output values generated by each TRNG to compare the amount of entropy with each method.

  • PDF

Acquisition Behavior of a Class of Digital Phase-Locked Loops (Digital Phase-Locked Loops의 위상 포착 관정에 관한 연구)

  • 안종구;은종관
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.5
    • /
    • pp.55-67
    • /
    • 1982
  • In this Paper new results relating to the acquisition behavior of a class of first-and secondorder digital phase-locked loops (DPLL) originally proposed by Reddy and Cupta are presented in the absence of noise. It has been found that the number of quantization levels L and the number of phase error states N play important roles in acquisition. For a given L-level quantizer, as N increases, the acquisition time increases, and the lock range decreases. However, the deviation of the steady state phase error decreases in this case. When L increases, the acquisition time decreases, and the lock range increases. However, variation of L affects little for the steady state phase error. In addition, the effects of a loop filter on acquisition have also been considered. One can get smaller acquisition time and larger lock range as the filter parameter value becomes larger. However, deviation of the steady state phase error increases in that case. Analytical results have been verified by computer simulation.

  • PDF

Digital Image Watermarking using Inner Product and Adaptive Quantization (내적과 적응성 양자화를 이용한 디지털 영상의 워터마킹 방법)

  • 이승욱;김진호;호요성
    • Journal of Broadcast Engineering
    • /
    • v.6 no.1
    • /
    • pp.50-57
    • /
    • 2001
  • A digital watermarking is a newly developed scheme to embed invisible or inaudible information Into the host data in order to insist the copyright of the owner or the creator. This paper describes a robust data embedding scheme that employs inner product and adaptive quantization. Compared to the previous works for digital watermarking, our proposed scheme can embed relatively large amount of Information, since a secrete key Is not directly relaxed to the watermark data. A secret key is used for the design of random direction vectors. which are taken Inner product with the DCT transformed feature set data. In odder to achieve robustness against malicious attacks. we exploit the Properties of human visual system In designing the random direction vectors which behave as embedded noises. Experimental results show that we can recover the embedded information without utilizing the original host data. We also demonstrate that the ownership assertion is possible even though The watermarked data may undergo common signal processing operations, such as JPEG compression. clopping. and filtering.

  • PDF

Enhanced Pre echo Control Algorithm for MPEG Audio Coders (MPEG 오디오 부호화기를 위한 향상된 프리 에코 컨트롤 알고리듬)

  • Lee Chang-Joon;Lee Jae-Seong;Park Young-Cheol
    • Journal of Broadcast Engineering
    • /
    • v.11 no.2 s.31
    • /
    • pp.191-199
    • /
    • 2006
  • This paper presents an efficient pre echo control scheme for MPEG Audio coders based on the psychoacoustic model II (PAM-II). Pre echo control is the final step for the calculation of masking threshold in the PAM II. It is to minimize the spread of quantization error over the processing frame. In the conventional encoders, pre echo is reduced by restricting the estimated masking threshold not to exceed the one obtained in the previous frame. The conventional method performs pre echo control not only for short blocks but also for long blocks, which lowers the masking threshold in long blocks and, in turn, increases the quantization noise level of corresponding blocks. This paper proposes an efficient pre echo control process. The test result shows a mean enhancement of more than 0.4 especially for complex signals on the ITU R 5 point audio impairment scale.

A study on the image transmission through CDMA (CDMA 채널을 통한 영상 전송에 대한 연구)

  • 허도근;김용욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.11
    • /
    • pp.2543-2551
    • /
    • 1997
  • This paper proposes a compression technique of image data, a variable length PN code and channel models which are required in CDMA communication system. It also analyzes their performances. Original images is compressed by 2-D DCT and its coefficients are quantized by optimal quantizer at compression rate 0.84bit/pel. Channel model 1 and 2 which are composed of 5 and 4 channels respectively are employed to be used in CDMA. Such a situation forces us to empoly variable length PN code, such as Chebyshev map for spread spectrum system. When average PN code length of model 1 and 2 is 44.4 and 26.7 chips respectively, the received image through these models under Gaussian noise with variance 1.75 is visually of the same quality as the transmitting image. Thus, the model 2 appears to be better in channel efficiency, comparing with channel model 1 and channel model which uses fixed length PN code.

  • PDF

Low-complexity Timing Synchronization System for IEEE802.11a Wireless LANs (IEEE802.11a 무선 랜 적용을 위한 시간동기 시스템 제안)

  • 하태현;이성주;김재석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.11B
    • /
    • pp.965-971
    • /
    • 2003
  • This paper suggests a low-complexity frame timing synchronization system for IEEE802.11a wireless LAN systems. The proposed timing synchronization scheme has been implemented by correlating the received OFDM preamble with quantized coefficients composed of {0, ${\pm}$2$^{0}$ , ${\pm}$2$^1$‥‥‥ ${\pm}$2$^{i}$ ), where i is an integer number. The 2$^{i}$ -valued coefficients enable the multipliers in the correlation system to be simplified to i-bit shifters. So we can design the correlation system using shifters instead of multipliers. We estimate the performance of the proposed scheme in comparison with conventional systems under the AWGN and Rayleigh fading channels. In this paper we show that the complexity can be reduced by 90% while still maintaining a performance comparable to that of the conventional system.

Performance Analysis of DVC Scheme with Adaptive Gray Code for Frame Difference Signal (화면 간 차이신호에 대한 적응적 그레이코드를 이용한 분산 비디오 부호화 기법의 성능 분석)

  • Kim, Jin-Soo;Kim, Jae-Gon;Choi, Hae-Chul
    • Journal of Broadcast Engineering
    • /
    • v.17 no.5
    • /
    • pp.876-890
    • /
    • 2012
  • In this paper, we investigated the performances of the distributed video codec with adaptive Gray code to apply for frame-difference signal. That is, the best cases and the worst cases were analyzed and compared by considering the statistical characteristics of the frame difference signal in view of the Gray code allocation. Through computer simulations, if 9-bit data for frame difference signal is generated for luminance signal with 8-bit definition and so n-bit is allocated to the quantized coefficient, we were able to find the best method to reduce the virtual channel noise by adding $256+2^{9-n-1}$ to the frame difference signal. Through computer simulation with test video sequences, it was shown that the performance difference between the best cases and the worst cases is larger than about 1.5dB at same rate. It is expected that the results in this paper are applicable for the transform-domain scheme as well as the pixel-domain scheme.

The Noise Evaluation for Ragius 150 CR System (Regius 150 Computed Radiography 시스템의 Noise 평가에 관한 연구)

  • Kim, Jung-Min;Min, Jung-Whan;Jeong, Hea-Won;Im, Eun-Kyung;Yang, Han-Joon
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.237-240
    • /
    • 2006
  • The Noise of CR Systems is made up of X-ray quantum mottle and additional Imaging plate's structure noise, photon noise of lumine cence, noise of electrometer, quantization noise etc. In this Regius 150 system, SNR was increased from 8.2 to 30 with linearily according to radiation dose from 0.1 mR to 100 mR. It means that the Regius 150 system has enough trustability because of SNR is over 5 by Rose Model. NPS was calculated two dementional Fourier Transform with shake of pixel value in the white Image. In the spatial frequence range of $0.5\;lp/mm{\sim}2.5\;lp/mm$, the NPS was distributed $10^{-4}{\sim}10^{-5}$ at 1 mR X-ray dose. That is similar result compare other systems to that of Kodak CR system reported by Carlu, HR-CR system reported by Dobbins.

  • PDF