• Title/Summary/Keyword: 양수시험

Search Result 279, Processing Time 0.027 seconds

The Scale-Dependent Dispersion Through Convergent Flow Tracer Tests in Alluvial Aquifer with High Permeability at the Ttaan isle, Gimhae City (김해 딴섬의 고투수성 충적층에서 수렴흐름 추적자시험에 의한 규모종속 수리분산 연구)

  • Kang, Dong-Hwan;Shim, Byoung-Ohan;Kwon, Byung-Hyuk;Kim, Il-Kyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.17-25
    • /
    • 2007
  • Convergent flow tracer test for 2 m (IW-1 well) and 5 m (IW-2 well) of test scale was conducted at the alluvial aquifer with high permeability and storativity. Pumping rate for convergent flow tracer test were $2,500m^3/day$, and the chloride tracer of 5 kg was instantaneously injected into IW-1 and IW-2 wells. Differences of first arrival time and peak concentration were analyzed by using the concentration breakthrough curves of chloride. Recovered chloride mass were analyzed by recovered cumulative mass curves. And, increment and decrement for chloride concentration were analyzed through chloride concentration versus recovered cumulative mass ratio graphs. Also, increment and decrement ratios of chloride concentration were estimated through linear regression analyses for increment and decrement intervals of chloride concentration. Longitudinal dispersivities were estimated by quot;Converging Radial Flow With Instantaneous Injectionquot; method using CATTI code. Longitudinal dispersivities estimated by CATTI code were 0.4152 m between pumping well and IW-1 well, and 3.2665 m between pumping well and IW-2 well. Longitudinal dispersivity was increased according to far distance from the pumping well. The longitudinal dispersivity according to distance were estimated as 0.21 between pumping well and IW-1 well, and 0.65 between pumping well and IW-2 well.

창녕군 증산리 지역 강변여과수 타당성 조사 및 시험 정호 설치

  • Kim Hyeong-Su;Won Lee-Jeong;Seok Hui-Jun;Park Cheol-Suk
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.76-81
    • /
    • 2006
  • 창녕군 증산리 지역은 신규 취수원 확보 일환으로 강변여과 방식 취수 가능성이 한국수자원공사에 의해서 평가되고 있는 지역이다. 강변여과 방식 취수의 타당성 평가를 위해 현장 지질조사, 시추조사, 전기 비저항 탐사 및 고해상도 탄성파 탐사를 수행하였다. 또한 대상 연구지역에서의 개략적 취수 가능량 산정을 위해 모델링 평가가 수행되었으며, 개별 정호에 대한 양수량 산정을 위해 시험 정호를 설치하였다. 현장 시추 조사와 시료에 대한 입도 분석 결과, 연구 지역의 충적층 두께는 35m 전후이며, 주 대수층 구간은 지표하 $25{\sim}35m$인 것으로 추정되었다. 또한 주 대수층 구간의 수리전도도는 $10^{-2}cm/sec$ 이상으로 주로 모래섞인 자갈층으로 구성되어있는 것으로 평가되었다. 또한 전기비저항 조사 결과는 부분적으로 매우 낮은 비저항 분포 지층을 보여주고 있으며, 이는 주로 실트 및 점토로 된 지층이 부분적으로 퇴적되어 있음을 지시하며, 고해상도 탄성파 탐사 결과는 전반적으로 지하수위는 지표하부 5m 전후에 분포하고, 충적층의 하부 경계는 35 내지 45m인 것으로 해석되었다. 지하수 모델링을 통해, 취수 목표량인 180,000톤/일은 주대수층까지의 지하수위 강하 없이 확보 가능할 것으로 평가되었다. 또한 개별 정호의 산출 특성을 평가하기 위해 시험 정호를 설치하여, 실제 2,700톤/일 예비 양수 시험을 수행하였다. 예비 양수 시험 결과, 양수정에서의 수위 강하는 개략 10m, 양수정관측정에서는 약 0.3m의 수위강하만이 관찰되었으며, 양수 영향권이 수 십 m를 넘지 않을 것으로 판단되었다.서의 S97과 JBR의 세포감염 억제율은 3.85%와 3.63%로 나타났다. $textsc{k}$-casein, CU는 로타바이러스 S97과 JBR에 대해 농도 2000UM에서 97%이상의 억제효과를 나타냈으며, sialic acid는 억제효과가 거의 없었다. K-casein, GMP는 송아지뿐만 아니라 유아의 로타바이러스에 의한 설사를 억제할 수 있을 것으로 기대된다.을 향상하기 위해서는 이러한 부위에 대한 미생물 오염을 낮출 수 있는 세심한 현장 품질관리가 필요하다.en and adolescents, analysed by country, age group and gender. The paper discusses the places young consumers can turn to in trying to fulfil their growing consumer needs. It also examines how much money is at their disposal. It then concludes by considering the influence of "financial socialization" on how young people deal with money.nsumption visions based on the various perspectives, consumers are influenced in the apparel buying decision-making. Many subjects reported experiencing positive affect when imagining positive outcomes of produc

  • PDF

프락탈 모델을 적용한 우리나라 균열 암반 대수층의 수리상수

  • 함세영
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 1995.03a
    • /
    • pp.121-134
    • /
    • 1995
  • 대수층의 수리상수를 산출하기 위한 양수시험 분석에 이용되는 가장 기본적인 이론은 Theis 이론이다. Theis 이론에서는 지하수의 흐름은 2차원의 방사상 흐름이다. 그러나, 1차 공극으로 이루어진 충적층 대수층이나 사암과 같은 다공질 대수층과는 달리 기반암내에 발달되어 있는 균열 대수층은 균열(fractures), 열극(fissures) 또는 단층과 같은 2차 공극으로 이루어져 있다. (중략)

  • PDF

Experimental Study on the Effect of Filter Layers on Pumping Capacity and Well Efficiency in an Unconfined Aquifer (자유면대수층에서 필터층이 취수량 및 우물효율에 미치는 영향에 대한 실험적 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Choi, Yong-Soo;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.405-416
    • /
    • 2017
  • This study evaluated a model unconfined aquifer comprising a sand or gravel layer, a filter layer, a pumping well, and an observation well. The model was employed in step drawdown tests and then used to assess the permeability of each test tank. The optimal yield and well efficiency were then calculated. Evaluation of yield by step in sand layer filters of equal thickness gave optimized watering rates of 22.03 L/min in the double filter and 19.71 L/min in the single filter. The double filter's yield was 115.0% that of the single filter. A comparison of double and single filters, each 10 cm thick, showed the double filter to have a maximum yield of 182.7%. Yields for the gravel layer were 73.56 L/min for a double filter and 65.47 L/min for a single filter of the same thickness; the former value is 112.3% of that of the latter. Comparison of double and single filters with 10-cm-thick gravel layers revealed that the double filter had a maximum yield of 160.9%. Results for sand wells showed the double filter to have a maximum efficiency of 70.4% and the single filter to have a minimum efficiency of 37.1%. Gravel-layer well efficiencies were >66.5% for both double and single filters (each 30 cm thick), but only 22.5% for a 10-cm-thick single filter. This study confirms that permeability improved as the filter material became thicker; it also shows that a double filter has a higher yield and well efficiency than a single filter. These results can be applied to the practical design of wells.

Study on the hydraulic properties of crystalline rock using Multi-Packer system (다중패커시스템을 활용한 결정질 암반의 수리 특성연구)

  • Lee, Jin-Yong;Kim, Kyung-Soo;Park, Kyung-Woo;Ryu, Si-Won;Han, Woon-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1924-1928
    • /
    • 2009
  • 다중패커시스템은 격리된 어느 특정 구간의 지하수를 채수할 수 있으며 그 구간의 온도, 압력 등의 자료를 연속적으로 관측할 수 있어 이를 통해 각 구간별 수리전도도를 구할 수 있다. 심도별 수직적 지하수두는 지상에서 연결 롯드를 통해 압력 측정 센서를 해당 심도까지 내려 롯드에서 설치된 압력 측정용 장비에서 관측할 수 있으며, 다중패커시스템을 이용한 수리시험으로는 양수시험, 순간충격시험, 간섭시험 등이 있는데, 본 논문에서는 순간충격시험을 이용한 결과를 제시하였다. 도출된 구간별 수리전도도를 다중패커시스템을 설치하기 전 나공에서 이중 패커를 이용한 정압주입시험의 결과와 비교하여 보았다. 다중패커시스템을 통해 획득된 심도별 지하수두는 정수두 (hydro-static)상태의 일정한 경향성이 없이, 각 심도에 존재하는 투수성 구조에 영향을 보이고 있음을 알 수 있었으며, 이는 다수의 관측공을 통해 수평 방향의 수리경사를 산출함에 있어 관측공의 심도에 대한 충분한 고려가 있어야 한다고 판단된다. 또한, 다중패커시스템을 이용한 수리시험 결과를 나공 상태에서 이중 패커를 이용한 정압주입시험 결과에 대해 심도별 도출되는 수리전도도가 국지적으로 분포하는 투수성 구조에 영향으로 인해 투수량계수 (transmissivity)로 환산한 유효 투수계수로 비교하여 결정질 암반의 수리 특성으로 제안하는 것이 타당한 것으로 분석되었다.

  • PDF

Relationship between groundwater pumping and streamflow depletion (하천인근 지하수 양수에 따른 하천수 영향 평가 상관식 개발)

  • Kim, Nam-Won;Lee, Jeong-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.422-422
    • /
    • 2012
  • 지하수개발 이용의 허가시 지하수 양수로 인한 주변지역에 미치는 영향을 조사하여 지하수의 고갈과 오염을 예측하고 이를 사전에 방지함으로써 지하수의 보전과 합리적인 이용을 도모하고자 지하수영향조사제도가 시행되어 왔다. 특히 하천구역의 경계로부터 300미터 내의 지역에서 지하수를 개발 이용하는 경우에는 지하수영향조사서를 첨부하여 국토해양부장관과 미리 협의하도록 되어있고, 이 때 지하수개발 이용이 하천의 수량에 영향을 미친다고 인정하는 경우에는 취수량 취수 기간의 제한 및 취수 금지 등을 요청할 수 있다. 그러나, 하천인근의 지하수 양수가 하천수에 미치는 영향을 정량적으로 평가할 수 있는 기법이 마련되어있지 않아 실무적으로 지하수영향조사 및 허가 절차상 어려움을 겪고 있다. 따라서 본 연구에서는 지하수 이용에 따른 하천수량 변화를 예측할 수 있는 간편 상관관계식을 지표수-지하수 통합모의 결과를 이용하여 유도 제시하였다. 지표수-지하수 통합모의를 위해서 SWAT-MODFLOW 결합모형을 적용하였고, 두 개의 시험유역에 대해 가상의 양수정 설치에 따른 하천수량 변화량을 평가하는 시나리오 분석을 수행하였다. 상관관계는 다중회귀분석을 통해서 하천수 감소량을 지하수 양수량, 하천과 양수정 이격거리, 대수층 및 하천바닥의 수리전도특성, 강수량 등의 함수로 나타내었다.

  • PDF

A Study on the Hydraulic Properties of Aquifers in Bucheon Area (부천지역의 지하수 대수층의 수리적 특성에 관한 연구)

  • Kim, So-Hee;Lee, Yoon-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.626-633
    • /
    • 2006
  • Bucheon city has been rapidly urbanized and steadily enlarged. Also, the city depends on groundwater as an alternative water resource. The objective of this study is to characterize the hydrogeology in this city including the recharge of groundwater and hydraulic property of an aquifer in order to investigate the chemical characteristics and contamination of groundwater in the Bucheon area. Eleven groundwater wells in the Bucheon area were selected for applying certain hydraulic tests, such as pumping and recovery tests. Theis method and Theis recovery method were used to obtain hydraulic parameters, such as hydraulic conductivity, transmissivity by applying recovery tests. The playground of school and uncovered areas layed a major function of recharging areas. The groundwater well in these areas showed high recharge, transmissivity, and hydraulic conductivity. In a downtown area, groundwaier wells showed low pumping capacity and hydraulic parameters. Groundwater samples were collected from 48 different locations in the Bucheon area and that showed very various chemical composition in groundwater Their electrical conductivity showed various ranges from 70.4 to $1,287{\mu}S/cm$. The composition more significantly affected the groundwater due to the land use and urbanization than that of the aquifer rock type.

Hydrogeological Characteristics of the Wangjeon-ri PCWC area, Nonsan-city, with an Emphasis on Water Level Variations (논산시 왕전리 수막재배지역의 지하수위 변화)

  • Cho, Byong-Wook;Yun, Uk;Lee, Byeong-Dae;Ko, Kyung-Seok
    • The Journal of Engineering Geology
    • /
    • v.22 no.2
    • /
    • pp.195-205
    • /
    • 2012
  • We evaluated the results of pumping tests, the amount of groundwater used by Protected Cultivation with Water Curtain (PCWC), and monthly depth to water table (DTW) at the Wangjeon-ri area, Nonsan City, to elucidate the cause of a decrease in pumping rate during the winter PCWC season. The transmissivity and storage coefficient at eight sites where the major aquifer is alluvium, vary from 119.9 to $388.1m^2/d$ and $1.5{\times}10^{-4}$ to $5.5{\times}10^{-4}$, respectively. The pumping rate for PCWC during three months (Dec. to Feb.) averaged about $8,100m^3/d$ and the maximum water level in the area varied by about 10 m. Groundwater levels had fully recovered by August-five months after pumping for PCWC had ceased. These observations indicate that the pumping rate during the winter PCWC season was excessive compared with groundwater productivity in the area. Groundwater level in the central PCWC area varied from -3.0 to 4.38 m, exceeding the water level of the Nosung Stream for only three months (Aug. to Oct.). This result indicates that Nosung Stream recharges the area during the period from November to July. To solve the problem of reduced pumping rate during the winter PCWC season, it would be necessary to reduce the amount of groundwater used for PCWC or to develop an artificial recharge system using recycled groundwater.