• Title/Summary/Keyword: 액 순환

Search Result 242, Processing Time 0.03 seconds

Economic Feasibility Assessment for the Interior Materials Selective Dismantling System Promotion in Buildings (건축물 분별해체 제도 활성화를 위한 경제적 효용성 평가)

  • Ji-Sun Park;Kyung-Pil Jang;Tae-Hyeob Song
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.251-259
    • /
    • 2023
  • In this study, as a foundational research aimed at promoting the efficient recycling and environmentally friendly disposal of construction waste through the activation of a selective dismantling system, our primary objective was to analyze the economic feasibility of implementing selective dismantling. To achieve this, we conducted an assessment on a 5-story residential building with a construction area of 2,400 m2 as a case study. When considering the additional cost of dismantling construction ① the reduction in waste disposal costs due to decreased mixed waste, ② and the potential revenue from recycling through the separation and sorting of waste materials, and ③ we were able to comprehensively confirm that there is an expected cost-saving effect totaling 34,727,000 KRW when compared to conventional demolition methods.

Analysis of Social Benefit for the Selective Dismantling System in Buildings (건축물 분별해체 제도 도입으로 인한 사회적 편익 분석)

  • Woo-Jin Park;Kyong-Pil Jang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.2
    • /
    • pp.222-228
    • /
    • 2024
  • This study aims to anal yze the social benefits of introducing a sel ective demol ition system for buil dings. Incremental revenue, incremental cost, and incremental profit for the entire nation were derived based on the calculated costs and revenues of selective demolition for a 2,400 m2 apartment complex. In conducting selective demolition on a 2,400 m2 building, the increase in demolition construction costs, the reduction in waste disposal costs due to the decrease in mixed waste, and the revenue obtained from recycling separated and sorted waste were comprehensively reviewed. It was calculated and analyzed that, compared to general demolition work, a total cost-saving effect of 34,727,000 KRW could be expected. Extrapolating this to the entire nation, based on the year 2020, which had the highest construction waste generation, it is estimated that the social benefits would amount to 746,782,886,000 KRW.

The Effects of Packed Red Blood Cell Washing and Circuit Precirculation-Ultrafiltration on the Production of Cytokines by Open Heart Surgery (충전용 농축적혈구의 세척 및 체외순환로의 전순환-초여과법이 개심수술에 의한 사이토카인 형성에 미치는 영향)

  • 전태국;노준량
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.199-208
    • /
    • 2002
  • Background: The washing of packed red blood cells could remove pro-inflammatory mediators, cell debris, and micro-particles contained in packed red blood cells, and the preci-rculation-ultrafiltration (recirculation and ultrafiltration of circuit itself before cardiopulmonary bypass) could attenuate the initial inflammatory reaction and remove the initial proinflam-matory mediators. This study was performed to evaluate whether the washing of packed red blood cells and precirculation-ultrafiltration can reduce the production of cytokines that have an important role in myocardial reperfusion injury. This study investigated the effects of washing the packed red blood cells and precirculation-ultrafiltration on the production of cytokines during and after cardiopulmonary bypass and open heart surgery. Material and Method: Forty eight infants with VSD undergoing open heart surgery under cardiopulmonary bypass were randomized into control group (group C, n=12), washing group (group W, n= 12), precirculation-ultrafiltration group (group F, n: 12), and combined group(washing and precirculation-ultrafiltration, group WF, n=12). Blood samples were obtained before, during, and after the bypass to assess plasma level of tumor necrosis factor-$\alpha$(TNF-$\alpha$), interleukin-6(IL-6), and interleukin-8 (IL-8). Results: Expressions of TNF-$\alpha$ were significantly reduced in combined group (group WF) compared with group C, group W, and group F (p<0.05). Expression of IL-6 were significantly reduced in group W, group F, and group WF compared with group C (p<0.05), but similar among group W, group F, and group WF (p=0.053). Expression of IL-8 were reduced in group W and group WF compared with group C (p<0.05), but similar among group W, group F, and group WF (p=0.067). Conclusion: In conclusion, the washing of packed red blood cells and precirculation-ultrafiltration blunted the increase of TNF-$\alpha$ , IL-6, and IL-8 during and after open heart surgery with cardiopulmonary bypass. However, the clinical benefits of these treatments remains unproven.

Isobaric Vapor-Liquid Equilibrium of Toluene and Cresol Systems (톨루엔-크레졸의 정압 기-액 평형)

  • Kang, Dong-Yuk;Jang, Hoi-Gu;Han, Chang-Nam;Rho, Seon-Gyun;Cho, Dong Lyun;Kang, Choon-Hyoung
    • Korean Chemical Engineering Research
    • /
    • v.47 no.6
    • /
    • pp.755-761
    • /
    • 2009
  • To a first approximation, phase behavior of a system becomes increasingly skew in proportion to the boiling point difference of system-forming constituents. Therefore, phase behavior data of a system of a large boiling point difference are to be experimentally measured for thorough understanding of the thermodynamic characteristics of such system. In this work, isobaric vapor-liquid equilibrium of a mixture consisting of toluene and cresol, which shows a large boiling point difference of nearly $100^{\circ}C$ and is consequently expected to be considerably nonideal, was measured by using a recirculating equilibrium cell at various subatmospheric pressures ranging from 10 kPa to 60 kPa. The measured VLE data were correlated with NRTL and UNIQUAC models in a satisfactory manner and the accompanying thermodynamic consistency test represented soundness of the measurements. In addition, the excess molar volume of the mixture was also measured with a vibrating densitometer and correlated with a Redlich-Kister polynomial. A negative excess volume prevailed over the whole concentration range, which indicates a favorable attraction between toluene and cresol isomers and results in an extensive miscibility.

Effects of Diluents and Cryoprotectants on Cryopreservation of Black Seabream (Acanthopagrus schligeli) Sperm (감성돔(Acanthopagrus schlegeli) 정자의 냉동보존에 미치는 희석액과 동해방지제의 영향)

  • 임한규;장영진
    • Journal of Aquaculture
    • /
    • v.11 no.1
    • /
    • pp.67-75
    • /
    • 1998
  • Experiments were performed to obtain cryopreservation techniques of black seabream (Acanthopagrus schlegeli) sperm. For sperm collection, brood stock reared in recirculating seawater system and fed with the commercial feed during experimental period. The results indicated that following cryopreservation method in block seabream sperm could be employed. Post-thaw survival rate of sperm revealed the highest value ($80{\pm}1.4$%) in 3% sodium citrate as a diluent for the cryopreservation. Cryopreserved sperm diluted with 5.4% glucose showed the highest fertilization rate to the ovulated eggs. Glycerol was a better cryoprotectant than dimethyl sulfoxide in sperm cryopreservation : survival rate and fertilizing capacity of cryopreserved sperm were decreased according to increase of glycerol concentration and varied in renges of 0.8~59.3% and 32.5~69.4% with 5~30% glycerol, respectively. A few of cryopreserved spermatozoa showed the enlarged head with granulated chromatin and ruptured plasma membrane by freezing and thawing injuries compared with unfrozen normal spermatozoa.

  • PDF

Isobaric Vapor-Liquid Equilibrium of 1-propanol and Bromochloromethane System at Subatmospheric Pressures (감압하에서 1-propanol과 Bromochloromethane의 정압 기-액 평형)

  • Jang, Hoi-Gu;Kang, Choon-Hyoung
    • Applied Chemistry for Engineering
    • /
    • v.21 no.3
    • /
    • pp.295-300
    • /
    • 2010
  • A binary system of 1-propanol and bromochloromethane which exhibits an azeotropic point and a considerable nonideal phase behavior probably due to the large boiling point difference is not amenable in the actual chemical processes such as the distillation tower and absorber. Therefore, experimental data of phase behavior data of this mixture are indispensable in understanding the inherent thermodynamic characteristics for an efficient application of the system in the industrial processes. In this work, the isobaric vapor-liquid equilibrium of a binary mixture consisting of 1-propanol and bromochloromethane was measured by using a recirculating equilibrium cell at various pressures ranging from 30 to 70 kPa. The measured VLE data were correlated in a satisfactory manner by using the UNIQUAC and NRTL models along with the thermodynamic consistency test based on Gibbs/Duhem equation. In addition, the excess molar volume of the mixture was also measured by using a vibrating densitometer and correlated with a Redlich-Kister polynomial.

Synthesis of ultrafine calcium carbonate powders from high concentrated calcium hydroxide solution (고농도 수산화칼슘 수용액으로부터 초미립 경질 탄산칼슘 분말의 합성)

  • Ahn, Ji-Whan;Park, Charn-Hoon;Kim, Jeong-Heo;Lee, Jong-Kook;Kim, Hwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.4
    • /
    • pp.509-520
    • /
    • 1996
  • Ultrafine calcim carbonate powders with the size of $0.05~0.1\;{\mu}m$ and the calcite phase were synthesized by the nozzle spouting method, which could be only obtained when high calcium ion concentration within slurry was maintained at the beginning of the reaction. But, in the regions of low ${Ca(OH)}_2$ concentration (0.5~1.0 wt%) or high ${Ca(OH)}_2$ concentration (<3.0 wt%), synthesized calcium carbonate powder was shown the large particle size with agglomeration. To obtain ultrafine calcium carbonate powder in this region, the methods of slurry circuation and $CO_{2}$ gas supply were changed during reaction. Resultly, it was possible to synthesize ultrafine particles (${\approx}0.05{\mu}\textrm{m}$)in the regions of low ${Ca(OH)}_2$ concentration (${\approx}0.5wt%$) and high ${Ca(OH)}_2$ concentration (${\approx}0.5wt%$), which can not be obtained the fine calcium carbonate powder still now.

  • PDF

Control of Mg and P Ion Concentration as a Precondition to Use N, K and Ca Ion Sensors in Closed Hydroponics (N, K, Ca의 한정된 이온센서 이용을 전제로 한 순환식 수경재배에서 P, Mg의 조절 방법)

  • Choi, Gyeong Lee;Yeo, Kyung Hwan;Rhee, Han Cheol;Lee, Seong Chan;Lee, Jung-Sup;Kang, Nam Jun;Kim, Hak Jin;Jung, Dae Hyun
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.871-877
    • /
    • 2016
  • Recycling nutrient solutions in closed hydroponic production systems is usually accompanied by an imbalance of nutrient solutions when concentration is controlled according to electrical conductivity (EC) levels. This study investigated whether it was possible to automatically control the concentrations of five essential elements nitrogen (N), phosphorus (P), potassium (K), calcium (Ca) and magnesium (Mg) using only N, K and Ca ion sensors. N, P, K, Ca, and Mg uptake was measured in the nutrient solution, and relationships between absorbed ions were analyzed through twice-repeated experiments in lettuce. Results confirmed that the pattern of $PO_4$ ion uptake was similar that of N, and the pattern of Mg ion uptake was similar that of Ca. $PO_4$ ion uptake was most highly correlated with N, and Mg was most highly correlated with Ca. Regression coefficients of N and $PO_4$ were significantly different at 1.04 and 0.55, respectively, but were similar between Ca and Mg at 0.35 and 0.40, respectively. Additional experiments were conducted to measure nutrient uptake in pak choi and rose plants, both to confirm the results from the first experiment in lettuce, and to assess possible application to other crops. Coefficients of determination both for N and $PO_4$, and Ca and Mg were considerably high ($R^2=0.86$) in cultured pak choi, and similar results were observed in cultured rose ($R^2=0.87$ and 0.73, respectively). Regression coefficients for cultured pak choi were 0.56 and 0.24, respectively, and for rose were 0.51 and 0.16, respectively. Although the results obtained for N and $PO_4$ were not consistent between the lettuce experiments, N and $PO_4$ have similar regression coefficients for all crops. No common coefficient was found between Ca and Mg.

The Neutralization Treatment of Waste Mortar and Recycled Aggregate by Using the scCO2-Water-Aggregate Reaction (초임계이산화탄소-물-골재 반응을 이용한 폐모르타르와 순환골재의 중성화 처리)

  • Kim, Taehyoung;Lee, Jinkyun;Chung, Chul-woo;Kim, Jihyun;Lee, Minhee;Kim, Seon-ok
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.359-370
    • /
    • 2018
  • The batch and column experiments were performed to overcome the limitation of the neutralization process using the $scCO_2$-water-recycled aggregate, reducing its treatment time to 3 hour. The waste cement mortar and two kinds of recycled aggregate were used for the experiment. In the extraction batch experiment, three different types of waste mortar were reacted with water and $scCO_2$ for 1 ~ 24 hour and the pH of extracted solution from the treated waste mortar was measured to determine the minimum reaction time maintaining below 9.8 of pH. The continuous column experiment was also performed to identify the pH reduction effect of the neutralization process for the massive recycled aggregate, considering the non-equilibrium reaction in the field. Thirty five gram of waste mortar was mixed with 70 mL of distilled water in a high pressurized stainless steel cell at 100 bar and $50^{\circ}C$ for 1 ~ 24 hour as the neutralization process. The dried waste mortar was mixed with water at 150 rpm for 10 min. and the pH of water was measured for 15 days. The XRD and TG/DTA analyses for the waste mortar before and after the reaction were performed to identify the mineralogical change during the neutralization process. The acryl column (16 cm in diameter, 1 m in length) was packed with 3 hour treated (or untreated) recycled aggregate and 220 liter of distilled water was flushed down into the column. The pH and $Ca^{2+}$ concentration of the effluent from the column were measured at the certain time interval. The pH of extracted water from 3 hour treated waste mortar (10 ~ 13 mm in diameter) maintained below 9.8 (the legal limit). From XRD and TG/DTA analyses, the amount of portlandite in the waste mortar decreased after the neutralization process but the calcite was created as the secondary mineral. From the column experiment, the pH of the effluent from the column packed with 3 hour treated recycled aggregate kept below 9.8 regardless of their sizes, identifying that the recycled aggregate with 3 hour $scCO_2$ treatment can be reused in real construction sites.

Thermal characteristics of energy textile by performing in-situ thermal response test (현장 열응답시험을 통한 에너지 텍스타일의 열적 거동 평가)

  • Lee, Chulho;Yoon, Sangbong;Han, Eunseon;Jeoung, Jae-Hyeung;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.167.2-167.2
    • /
    • 2010
  • 본 연구에서는 지열 에너지원으로써 터널 내부 벽면의 항온성을 이용하여 터널 외벽에 텍스타일 형태의 열교환기를 설치하고 열적 거동을 평가하였다. 터널의 라이닝 부분에서는 여러 가지 요인에 의해 지하수가 터널 내부로 유입하게 되므로 지하수의 유무에 대한 열적 거동 및 유동액의 순환 속도에 따른 영향, 열교환 파이프 배열 형태에 따른 영향을 현장 시험 시공과 현장 열응답시험을 통하여 평가하고자 하였다. 또한 3-D 유한체적해석 프로그램(FLUENT)을 이용하여 숏크리트와 라이닝의 열전도도를 고려한 열교환기의 성능을 분석하였다. 수치해석 결과 열교환 파이프 주변에 지하수의 흐름이 존재할 경우 열전달이 상대적으로 더 원활히 이루어졌으며 순환속도가 빠를 때 보다 느릴수록 효율이 높게 나타났다. 또한, 파이프의 간격이 넓을수록, 파이프의 길이가 길수록 효율이 높게 나타났다. 라이닝 및 숏크리트의 열전도도가 증가함에 따라 에너지 텍스타일의 열전달 효율이 높게 나타났다. 현장 시험을 통해 비슷한 길이의 파이프가 사용된 경우, 파이프 배열 형태에 따라 수평형보다는 수직형 배열의 효율이 높게 측정되었다.

  • PDF