• Title/Summary/Keyword: 액체 질소(liquid nitrogen)

Search Result 245, Processing Time 0.034 seconds

Hydraulic Performance Test of a Turbopump Inducer using Liquid Nitrogen (액체질소를 이용한 터보펌프 인듀서의 수력성능시험)

  • Kim Jin-Sun;Hong Soon-Sam;Kim Jin-Han
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.20-26
    • /
    • 2006
  • A cryogenic test facility has been developed to perform inducer and pump tests using liquid nitrogen. Performance tests of a turbopump in the maximum 50ton-thrust class can be performed with cryogenic fluid in the facility which operates at a temperature around -196oC with the rotational speed up to 30,000rpm To verify the reliability of the cryogenic pump test facility, hydraulic performance tests of an inducer were accomplished, and their results were compared with the result from a water test. The results confirm the reliability of the cryogenic test facility, and it is expected to contribute for on-going development of a turbopump for liquid rocket engines.

The effect of electrode on the dielectric breakdown properties in liquid nitrogen (액체 질소의 절연특성에 미치는 전극효과에 관한 연구)

  • 김상현;김정호;윤문수;권영한
    • Electrical & Electronic Materials
    • /
    • v.4 no.2
    • /
    • pp.114-122
    • /
    • 1991
  • 본 논문에서는 최근의 고온초전도체 재료의 개발에 주목하여 액체 질소의 절연파괴특성에 전극이 미치는 영향에 관하여 연구하였다. 액체 질소의 극성효ㅗ가는 액체 헤리움과는 달리 전극간 거리에 따라 다르며 단 간격에서의 파괴정압은 평등전계가 가장 높고, 정침, 부침의 순서이며 장 간격에서는 역전한다. 그리고 conditioning효과, 불순물효과, 피복효과, 압력의존성 등의 실험으로 부터 액체 질소의 파괴기구는 정침에서는 정 스트리머, 부침에서는 기포파괴의 가능성이 높은 것으로 생각된다. 또한 극저온 절연 설계에서는 전극을 절연물로 피복하고 고순도 액체 질소보다는 불순물이 혼입된 액체 질소, 즉 상용 액체 질소를 냉각 및 절연재료로 사용하면 유리하다.

  • PDF

The Characteristics of Tracking Phenomena and Surface Discharge Using Various Types of Electrode Arrangement in LN2 at the Atmospheric Pressure (대기압하의 액체질소중 전극배치에 따른 고체유전체 표면의 연면방전 및 Tracking현상)

  • 박광서;신호영;최병주;박원주;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.49-55
    • /
    • 2003
  • This paper studied characteristics of surface discharge and tracking phenomena on the surface of solid insulators in Liquid Nitrogen(LN2) noticed as a cooling medium of high temperature superconductor. In order to investigate the bubble effect which have much influence on electric surface discharge in Liquid Nitrogen, knife type electrode and plane electrode were formed oppositely with A-mode, B-mode and C-mode configuration. It is considered that these result are fundamental data for electric insulation design of superconductor and cryogenic application machinery which will be studied and developed in the future.

Structural Change of Supersonic Jet Due to Liquid Injection in Supersonic Backward Facing Step Flow (초음속 후향 계단 유동에서 액체 분사로 인한 초음속 제트의 구조 변화)

  • Ahn, Sang-Hoon;Han, Doo-Hee;Choi, Han-Young;Seo, Seong-Hyeon;Sung, Hong-Gye
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.6
    • /
    • pp.9-16
    • /
    • 2019
  • The experiment on the liquid jet in crossflow in supersonic BFS (backward-facing step) flow was conducted to investigate the mixing characteristics. The working fluids are nitrogen and water. The shadow graph technique was used to visualize the flow field. Images captured by the high-speed camera were applied to analyze the flow phenomena. The liquid jet was injected at the re-circulation zone created by the supersonic jet flow. Experimental conditions are defined based on the pressure of the nitrogen gas chamber and pressurized liquid tank. In respective cases, the penetration depth of liquid jet and location of the Mach disc were observed to be proportional to the momentum ratio of gas and liquid jets.

Experiments of Continuous Release of Liquid Nitrogen (액체질소의 연속 누출 실험)

  • YONG-SHIK HAN;MYUNGBAE KIM;LE-DUY NGUYEN;MINCHANG KIM;CHANGHYUN KIM;TAE-HOON KIM;KYU HYUNG DO;BYUNG-IL CHOI
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.5
    • /
    • pp.526-534
    • /
    • 2023
  • To evaluate the risk of leakage when using liquid hydrogen, a leakage test was conducted using liquid nitrogen in an outdoor environment rather than a laboratory environment. To assume a real-scale continuous leak, liquid nitrogen was allowed to leak for 5 minutes through a pipe with a diameter of 25.4 mm at a design spill rate of 60 L/min. The measurement system consisted of devices for climate conditions, LN2 spread and vapor clouds. The main experimental results are the liquid pool radius and the concentration of vapor cloud, and the radius of the liquid pool was compared with the numerical analysis results.

Fabrication of Level Meter for Liquid Nitrogen (액체 질소 액면계의 제작)

  • 김상보;김근홍;김종윤;이정민;김동락
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.182-184
    • /
    • 1999
  • Very simple continuous level meter with capacitive transducer for cryogenic liquid is fabricated and tested with liquid nitrogen. The principle of the level meter operation is presented.

  • PDF

Cooling of Cryogenic Liquids by Gas Helium Injection (I) (가스분사에 의한 극저온 액체의 냉각에 관한 연구 (I))

  • Song, Yi-Hwa;Choi, Young-Hwan;Kim, Yoo;Chung, Yong-Gahp;Cho, Nam-Kyung;Jeong, Sang-Kwon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.141-144
    • /
    • 2003
  • In this paper, to satisfy the temperature requirement of turbopump-inlet condition, the cooling of cryogenic propellant is performed at the simulated suction-line of the Launch Vehicle. The cooling method is by using Gas helium injection. This study investigates the effect of helium injection on the liquid nitrogen which simulates the liquid oxygen. By using helium injection, the subcooling of liquid nitrogen can be achieved within four minute when the ratio of gas volume flowrate to the volume of L$N_2$ is approximately v/v$_{L}$≒0.8min$^{-1}$ . .

  • PDF

Experimental Study of the Evaporation of Spreading Liquid Nitrogen (확산하는 액체질소의 증발에 관한 실험적 연구)

  • KIM, MYUNGBAE;CHOI, BYUNGIL;KIM, TAE-HOON;DO, KYHYUNG;HAN, YONGSHIK;CHUNG, KYUNGYUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.466-472
    • /
    • 2018
  • The investigation of cryogenic liquid pool spreading is an essential procedure to assess the hazard of cryogenic liquid usage. In this experimental study, to measure the evaporation velocity when the pool is spreading, liquid nitrogen was continuously released onto unconfined concrete ground. Almost all of the reported results are based on a non-spreading pool in which cryogenic liquid is instantaneously poured onto bounded ground for a very short period of time. A simultaneous measurement of the pool location using thermocouples and of the pool mass using a digital balance was carried out to measure the evaporation velocity and the pool radius. A greater release flow rate was found to result in a greater average evaporation velocity, and the evaporation velocity decreased with the spreading time and the pool radius.

Flow Boiling Heat Transfer Characteristics of Liquid Nitrogen in Plain and Wire Coil Inserted Tubes (평활관 및 와이어코일을 삽입한 열전달촉진관에서 액체질소의 흐름비등열전달 특성)

  • Hwang Jee-Sang;Yun Rin;Kim Yongchan;Chung Jin Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.927-933
    • /
    • 2005
  • Boiling heat transfer characteristics of liquid nitrogen in a stainless steel plain tube and wire coil inserted tubes were investigated. The test tubes, which had an inner diameter of 10.6 m and a length of 1.65 m, were horizontally located. Five wire coils having different pitch and thickness were inserted into the plain tube. The pitches of the wire coils were 18.4, 27.6, and 36.8 m, and the thickness was 1.5, 2.0, and 2.5 mm respectively. Tests were conducted at a saturation temperature of $-191^{\circ}$, mass fluxes from 58 to 105 kg/$m^2s$, and heat fluxes from 22.5 to 32.7 kw/$m^2$. A direct heating method was used to apply heat to the test section. The boiling heat transfer coefficients of liquid nitrogen were represented as a function of vapor quality, which showed significant drop at the dryout vapor quality. The maximum heat transfer enhancement using the wire coil inserted tubes over the plain tube was $174\%$ for 'Wire 3' having a thickness of 2.5 mm and a pitch of 18.4 mm.

LN2 storage test and damage analysis for a Type 3 cryogenic propellant tank (타입 3 극저온 추진제 탱크의 액체질소저장 시험 및 파손 분석)

  • Kang, Sang-Guk;Kim, Myung-Gon;Park, Sang-Wuk;Kong, Cheol-Won;Kim, Chun-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.7
    • /
    • pp.592-600
    • /
    • 2007
  • Nowadays, researches for replacing material systems for cryotanks by composites have been being performed for the purpose of lightweight launch vehicle. In this paper, a type 3 propellant tank, which is composed of the composite developed for cryogenic use and an aluminum liner, was fabricated and tested considering actual operating environment, that is, cryogenic temperature and pressure. For this aim, liquid nitrogen (LN2) was injected into the fabricated tank and in turn, gaseous nitrogen (GN2) was used for pressurization. During this test procedure, strains and temperatures on the tank surface were measured. The delamination between hoop layer and helical one, was detected during the experiment. Several attempts were followed to investigate the cause analytically and experimentally. Thermo-elastic analysis in consideration of the progressive failure was done to evaluate the failure index. Experimental approach through a LN2 immersion test of composite/aluminum ring specimens suitable for simulating the Type 3 tank structure.