• Title/Summary/Keyword: 압축일량

Search Result 13, Processing Time 0.021 seconds

Performance Analysis of R744(Carbon Dioxide) for Transcritical Refrigeration System (R744용 초임계 냉동사이클의 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.32-38
    • /
    • 2009
  • In this paper, cycle performance analysis for cooling capacity, compression work and COP of R744($CO_2$) transcritical vapor compression refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : The cooling capacity of R744 increases with superheating degree, but decreases with the increasing evaporating temperature and outlet temperature of gas cooler. The compression work increases with superheating degree and cooling pressure of R744, but decreases with the increasing evaporating temperature. And, The COP increases with outlet temperature and evaporating temperature of R744 gas cooler, but decreases with the increasing superheating degree. Therefore, superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

Characteristics of Cryogenic Cascade Refrigeration Cycle for Liquefaction of Natural Gas with the Pressure Drop of Heat Exchanger (LNG 열교환기의 압력강하에 따른 천연가스 액화용 초저온 캐스케이드 냉동사이클 특성)

  • Yoon, Jung-In;Choi, Kwang-Hwan;Son, Chang-Hyo;Kwag, Jin-Woo;Baek, Seung-Moon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.756-761
    • /
    • 2012
  • Natural gas is converted in to LNG by chilling and liquefying the gas to the temperature of $-162^{\circ}C$, when liquefied, the volume of natural gas is reduced to 1/600 of its standard volume. This gives LNG the advantage in transportation. In this study, the effects of the pressure drop of refrigerant and natural gas in the LNG heat exchanger of cryogenic cascade refrigeration cycle were investigated and then the design criteria for the pressure drop of refrigerant and natural gas of the LNG heat exchanger were proposed. The pressure drop of the cascade liquefaction cycle was investigated and simulated using HYSYS software. The simulation results showed that the pressure drop in the LNG heat exchanger is set to 50 kPa considering the increase in the compressor work and COP of cryogenic cascade liquefaction cycle.

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.

The pressure drop characteristics in LNG heat exchanger of cryogenic cascade refrigeration cycle (초저온 캐스케이드 냉동사이클의 LNG 열교환기 압력강하 특성)

  • Yoon, J.I.;Choi, K.H.;Kwag, J.W.;Son, C.H.;Baek, S.M.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.376-381
    • /
    • 2012
  • Natural gas is converted in to LNG by chilling and liquefying the gas to the temperature of $-162^{\circ}C$, when liquefied, the volume of natural gas is reduced to 1/600th of its standard volume. This gives LNG the advantage in transportation. The pressure dorp of the cascade liquefaction cycle was investigated and simulated using HYSYS software. The simulation results showed that the pressure drop in the LNG heat exchanger is set to 50 kPa considering the increase in the compressor work of cryogenic cascade liquefaction cycle.

  • PDF

System Performance for Length and Diameter of Capillary Tube using R-1270 (모세관 길이와 관경 변화에 따른 R-1270의 성능특성)

  • Lee, Ho-Saeng;Kim, Hyun-Woo;Choi, Won-Jae;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.646-652
    • /
    • 2009
  • Experimental results for performance characteristics of HCs refrigerant R-1270 and HCFC refrigerant R-22 during refrigeration system using capillary tube are presented. The system consists of compressor, condenser, capillary tube, evaporator and peripheral devices. Length and diameter of capillary tube are varied for this investigation. The refrigerant mass flow increased as the diameter of capillary tube increased and the length of capillary tube decreased. A refrigeration capacity and compressor work of R-1270 in same length and diameter of capillary tube showed the higher values than those of R-22. A coefficient of performance showed the highest value when the length and diameter of capillary tube are 105 cm and 1.8 mm in this experimental conditions.

An Experimental Study on Performance Characteristics of Two-Stage Compression Refrigeration Systems (2단압축 냉동장치의 성능특성에 관한 실험적 연구)

  • 김재돌;오후규;김성규;권옥배
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.25-32
    • /
    • 1994
  • The characteristics of the R-22 two-stage compression refrigeration systems were investigated. The apparatus consisted of 0.5HP and 1HP hermetic reciprocating compressors for the high and low stage sides respectively, a condenser, an evaporator, a heat exchanger, four expansion valves, and two intercoolers. The experiments covered a range of refrigerant flow rates from 24 to 84kg/h, and the inlet temperature of cooling water in the condenser and heat source water in the evaporator ranged from 20 to 30$^.\circ}C$The results Showed that the refrigerant flow rate had greater effect on the refrigerating capacities, the compression efficiency and the coefficient of performance of two-stage compression systems than the inlet temperature of heat source water. And all these values were decreased with increasing inlet temperatures of the cooling water. The pressure drops in the evaporator of two-stage compression systems were decreased in proportion to the increase in the inlet temperature of the heat source and cooling water, but it was increased by the refrigerant flow rate.

  • PDF

Efficiency and Exergy Analysis of New Liquefaction Cycles Applied for LNG FPSO (LNG FPSO에 적용가능한 신액화 사이클의 효율 및 엑서지 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kwag, Jin-Woo;Shim, Gyu-Jin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.574-579
    • /
    • 2012
  • This paper presents the new cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2$. The performance and exergy of cascade liquefaction cycles are analyzed using HYSYS software and then confirmed the possibility of these cycles for LNG-FPSO ship. From the comparison of performance and exergy loss of these cycles, the cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ showed higher performance and the cycle using $CO_2-N_2$ presented higher exergy loss. The cascade liquefaction cycle using $CO_2-N_2$ is lower efficiency and higher compressor work compared to the optimized cascade liquefaction cycle using $C_3H_8-C_2H_4-C_1H_4$. But, if the efficiency of $N_2$ cycle in these liquefaction cycles is improved, it is possible to apply the cascade liquefaction cycle using $CO_2-C_2H_6-N_2$ and $CO_2-N_2$ to LNG-FPSO ship due to the simple composition device of these cycles.

Theoretical study on the performance improvement of refrigeration system installed with ejector entraining expansion gases after expansion process (이젝터를 적용한 팽창기체 흡입 냉동시스템의 성능향상 해석 연구)

  • Yun, Sangkook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.828-833
    • /
    • 2014
  • In this paper, the performance characteristics for newly developed ejector refrigeration system, which is that the part of saturated vapor from liquid-vapor separator after ejector expansion process is entrained in ejector, and the saturated liquid flows in the evaporator and compressed with the rest of vapor in separator, is studied. The reasons of the performance improvement of refrigeration system are that the refrigeration capacity is increased due to quality reduction after iso-entropic expansion process by ejector and the compression work is reduced because of the relatively high pressure of vapor refrigerant before compression process. The comparison results of the ejector system entraining expansion gases with the present residential freezer show that the COP increases to 27.8% maximum in case of the pressure drop to 65% of high pressure of freezer, and to 40.1% for 75% pressure drop of refrigerant R401A. The COP improvement rate with 20%~60% pressure lift in diffuser of ejector is only 2.6%~3%.

Experimental study on the performance of heat pump system using $CO_2$ (이산화탄소용 열펌프시스템의 성능특성에 관한 실험적 연구)

  • Jang, Seong-Il;Jeon, Min-Ju;Yu, Tae-Guen;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.55-56
    • /
    • 2006
  • 냉매 충전량과 이차유체의 입구조건은 $CO_2$용 열펌프시스템의 성능실험에서 중요한 제어변수이다. 따라서, 열펌프사이클의 적용과 난방성능 향상을 위해 제어변수의 특성을 조사하는 것이 필요하다. 본 논문에서, $CO_2$용 열펌프 사이클의 성능 실험은 여러 가지 냉매 충전량에서 이차유체 입구조건에 변화를 주어 수행 되었다. 실험결과, 난방COP는 냉매 충전량이 증가함에 따라 1158g의 냉매 충전량에서 최대가 되었다가 감소하는 경향이 나타나며, 이는 COP가 최대가 되는 냉매충전량이 존재함을 나타낸다. 또한, 난방성능은 가스쿨러내 이차유체의 질량유량의 증가에 따라 증가하였다. 가스냉각기내 2차유체의 입구은도가 $10^{\circ}C$에서 $40^{\circ}C$로 증가하면, 난방용량, 압축일량, 토출압력은 각각 -8.57%, -35.89%, 32.78%로 변화했으며, 증발기 2차유체의 입구 온도가 감소하였을 때 난방COP는 감소하는 경향을 보였다.

  • PDF

Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions (운전조건 변화에 따른 hot-gas 바이패스 냉동장치의 성능 특성)

  • Baek, Seung-Moon;Son, Chang-Hyo;Heo, Jeong-Ho;Choi, In-Soo;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1021-1026
    • /
    • 2014
  • In this paper, among various systems applying hot-gas bypass control, outdoor temperature, outlet temperature of water cooler, superheating and subcooling degree, which are the factors affecting the performance of the system bypassing hot-gas to evaporator inlet were analyzed. The main results were summarized as following. Frist of all, performance of refrigeration system bypassing hot-gas to evaporator inlet was affected by outdoor temperature, outlet temperature of water cooler, superheating and sub cooling degree. Thus, providing basic planning date of refrigeration system obtained through optimization of variables is expectable. Thus, providing the basic design data of refrigeration system can be offered by performing the optimization of these variables. Also, the feasibility of this refrigeration system proposed in this paper was obtained by analyzing operating characteristics of the system bypassing hot-gas to evaporator inlet.