• 제목/요약/키워드: 압축냉각공기

Search Result 71, Processing Time 0.031 seconds

냉각.윤활방식 변화에 따른 가공면의 미시적 정밀도 평가 (Microscopic precision evaluation of machined surface according to the variation of cooling and lubrication method)

  • 황인옥;권동희;강명창;김정석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.225-226
    • /
    • 2006
  • As the technique of high-speed end-milling is widely adopted to machining field. The investigation for microscopic precision of workpiece is necessary for machinability evolution. The environmental pollution has become a big problem in industry and many researcher have investigated in order to preserve the environment. The environmentally conscious machining and technology have more important position in machining process. In the milling process, the cutting fluid has greatly bad influence on the environment. The damaged layer affect mold life and machine parts in machining. In this study, the cutting force, the surface roughness, micro hardness and residual stress is evaluated according to machining environment. Finally, it is obtained that the characteristics of damaged layer in environmentally conscious machining is better than that in conventional machining using cutting fluid.

  • PDF

레이저 3D 프린팅 기법으로 제작한 열교환기 성능시험 분석 연구 (Experimental analysis of heat exchanger performance produced by laser 3D printing technique)

  • 김무선
    • 한국산학기술학회논문지
    • /
    • 제21권7호
    • /
    • pp.270-276
    • /
    • 2020
  • 3D 프린팅은 고분자, 세라믹, 금속 등 다양한 소재를 대상으로 복합적인 형상을 한 번의 공정으로 제작할 수 있는 적층 기반 제작 기술이다. 최근의 3D 프린팅 기술은 프린팅 속도의 향상과 적용 가능 소재의 지속적인 개발에 의해 양산형 제품 생산이 가능한 수준으로 발전하였다. 본 연구에서는 레이저를 활용한 3D 프린팅 기술을 적용하여 철도 차량용 공기 압축기에 쓰이는 열교환기 제작을 진행하였다. 먼저 3D 프린팅에 적합한 형상으로 경량화 및 컴팩트화를 주안점으로 열교환기의 최적 설계를 진행하였다. 그로부터 도출된 설계안을 기반으로 SLM 기법을 적용하여 AlSi10Mg 합금 소재로 열교환기 시작품을 제작하였다. 다음으로, 제작된 시작품을 기존 공기 압축기에 부착하여, 압축공기의 열교환 성능을 시험하였다. 3D 프린팅 시작품의 시험 결과는 기존 열교환기 대비하여 저압부와 고압부에서 열교환 성능은 각각 약 80% 및 85% 수준을 보였다, 하지만 외부 냉각공기 조건을 기존 열교환기와 유사한 조건으로 가정하였을 때 𝓔-NTU 법을 활용하여 계산한 열전달량은 기존 열교환기 대비하여 유사한 성능을 보여 주었다. 결과적으로, 3D 프린팅 제작 열교환기의 성능 효과 및 경량화 등의 장점을 확인할 수 있었다.

냉각공기 유속 측정에 기반한 철도차량용 공기압축기 열교환기의 열전달 특성 분석 (Heat Transfer Analysis of a Heat Exchanger for an Air-Compressor of a Railway Vehicle Based on Cooling Air Flow Measurement)

  • 안준;김무선;장성일
    • 설비공학논문집
    • /
    • 제29권9호
    • /
    • pp.447-454
    • /
    • 2017
  • In this study, local velocity distribution of cooling air in a heat exchanger used in an air compressor for a railway car was measured and heat transfer characteristics of the heat exchanger were analyzed. First, heat transfer coefficient and fin performance of the cooling air side were predicted and was checked if the fin of the heat exchanger was effectively used. Distribution of air flow rate at high temperature side was predicted through pipe network analysis and heat resistance at high temperature and low temperature side were predicted and compared. Spatial distribution of temperature in the interior and surface of the square channel constituting high-temperature side was predicted and appropriateness of the size of the heat exchanger was examined. As a result of the analysis, the present size of the heat exchanger could be reduced and it could be effective to promote heat transfer inside the heat exchanger rather than outside to improve performance of the heat exchanger.

볼텍스 튜브용 소음기 성능 개발 (Performance Development of the Silencer for a Vortex Tube)

  • 조영호;김창수;박성영
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2012년도 춘계학술논문집 2부
    • /
    • pp.659-661
    • /
    • 2012
  • 볼텍스 튜브란 압축가스의 흐름을 뜨거운 공기와 차가운 공기로 전환 시켜주는 냉각 장치이다. 본 논문에서는 볼텍스 튜브에서 발생되는 소음의 특성을 파악하고자 하였다. 1/2in 소음기와 3/8in 소음기는 소음기를 장착하지 않은 경우 보다 평균8~10dB 감소되었고, 1/4in 소음기는 약15dB정도 감소하였다. 출구를 가공한 1/2in 소음기의 소음은 소음기를 장착하지 않은 경우와 비슷하고 3/8in 소음기는 소음 감소폭이 적었다. 1/4in 소음기기의 소음은 압력이 커질수록 소음이 급격히 커지는 것을 알 수 있다. 기존의 소음기와 출구를 가공한 소음기를 비교 하였을 경우 1/2in 소음기에서는 평균 9dB정도 기존 소음기의 성능이 좋고, 3/8in 소음기에서는 평균 7.5dB정도 성능이 좋은 것을 알 수 있다. 1/4in 소음기에서는 평균 9.5dB정도 기존 소음기가 소음 감소폭이 크며 압력에 따른 소음의 감소폭이 차이가 큰 것을 알 수 있다.

  • PDF

화재진압용 비활성가스제너레이터 성능해석 및 시험 (Experimental & Performance Analysis of an Inert Gas Generator for Fire Suppressing)

  • 김수용;코발레프스키
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2001년도 제16회 학술발표회 논문초록집
    • /
    • pp.86-89
    • /
    • 2001
  • 본 연구는 화재를 효과적으로 진압하기 위한 비활성가스제너레이터의 성능 해석 및 실험에 관한 연구의 내용을 담고 있다. 비활성가스제너레이터는 가스터빈을 이용하여 화재를 진압하기 위한 비활성가스를 제조한다. 일반적으로 연소화합물 속에 산소함유량이 낮을수록 화재진압이 용이한 것으로 알려져 있다. 비활성가스제너레이터 시스템에 급수 노즐을 설치하여 물을 분사하는 경우 화재진압에 필요한 냉각 및 질식효과를 갖는 다는 점에서 유리하다. 비활성가스제너레이터 성능에 미치는 몇몇 중요한 인자인 압축비, 과급 공기지수, 연소기 입출구 온도, 공기 유량 및 급수량에 관한 영향을 조사하였다.

  • PDF

오일 미스트 분사 방법에 따른 연삭특성 (A Study on the Grinding Characteristics according to Oil Mist Supply Method)

  • 허남환;이석우;최헌종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.254-257
    • /
    • 2002
  • As the large Coolant amount used of a machine holds mass serious trouble recently, an environment pollution is increased, and a machine is conquering large specific gravity in an empty cost plane. It is the stage that must reexamine the parts washing that processing is later with this current way or a problem of a liquid waste treatment back. The environmental problems by using coolant demanded the new cooling methods. As one of them, the studies on the grinding with compressed cold air and oil mist have been done. The cooling method using compressed cold air was effective through going down the temperature of compressed air supplied below -$25^{\circ}C$ and increasing the amount of compressed cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using oil mist newly were suggested. This method can satisfy both cooling effect and lubrication with only small amount of coolant, also have the benefit in the point of decreasing the environmental pollution. This paper focused on analyzing the grinding characteristics of the cooling method using oil mist. The grinding test according to compressed cold air and oil mist supply direction were done.

  • PDF

하수슬러지 건조를 위한 폐루프 공기건조 기술에 관한 연구 (A Study on the Closed-Loop Air Drying Technology for Drying Wastewater Sludge)

  • 이정언;조은만;강동효
    • 대한환경공학회지
    • /
    • 제34권12호
    • /
    • pp.821-827
    • /
    • 2012
  • 슬러지 공기건조장치는 외기로부터 공기를 흡입/송풍하여 이젝터(Ejector) 및 다단 사이클론(Multi-Cyclone)에서 슬러지를 건조하는 시스템이다. 즉 공기건조장치는 외기의 조건에 따라 시스템 성능 변화가 클 뿐 아니라 개루프(Open-Loop) 구조로 되어 있어 에너지 소모량이 큰 단점이 있다. 이를 해결하기 위한 방안으로 공기건조장치의 분리기 후단에 응축기(Condenser), 냉각기(Cooler), 압축기(Compressor)로 구성된 제습기를 장착하여 송풍-건조-제습-송풍으로 순환하는 폐루프(Closed-Loop) 공기건조 기술을 개발하였다. 기존의 공기건조와 비교하여 본 기술의 특성을 비교 분석한 결과, 본 시스템의 공기는 외기에 비하여 약 50% 이상의 에너지를 더 많이 함유하고 있었다. 또한 공기가 시스템 내에서 순환하기 때문에 슬러지 건조에 공급하는 공기의 질을 일정하게 유지할 수 있어 시스템을 안정적으로 운용할 수 있을 것으로 분석되었다. 그리고 경제성을 분석한 결과, 폐루프 공기건조장치를 이용하여 슬러지 1톤을 건조하는데 소요되는 비용은 기존의 건조장치에 비하여 약 35% 절감되는 것으로 파악되었다. 따라서 본 기술은 에너지 소모량이 적고, 일정한 품질의 공기를 송풍할 수 있어 시스템의 안정적으로 운전할 수 있는 기술로 평가된다.

충돌제트에서의 횡방향 유동 감소를 위한 파형 구조의 유동 및 열전달에 관한 연구 (A Study on Fluid Flow and Heat Transfer of a Corrugated Structure for Crossflow Reduction of Impingement Jet)

  • 황병조;김선호;주원구;조형희
    • 대한기계학회논문집B
    • /
    • 제41권5호
    • /
    • pp.329-339
    • /
    • 2017
  • 충돌제트는 제트가 충돌하는 정체 영역에 매우 높은 열전달을 제공하기 때문에 다양한 분야에서 적용되고 있다. 그러나 제트가 벽면에 부딪친 후 벽면 제트에 의해 야기되는 충돌 챔버 내의 횡방향 유동은 여러 개의 제트로 구성된 배열제트인 경우 하류에 있는 제트 유동을 방해하거나 휘게 할 수 있으며, 이로 인해 배열 충돌제트의 냉각 성능은 감소하게 된다. 파형 구조는 하류 제트에서의 횡방향 유동영향을 줄이기 위해 인접한 충돌 제트 사이에 있는 파형 속에 사용된 냉각 공기를 유입시키는 역할을 하며, 이러한 파형 구조에서의 유동 및 열전달 특성에 대해 수치해석을 수행하였다. 3차원, 정상상태, 비압축성 유동으로 고려하고 해석하였으며 ANSYS-CFX 15.0 코드를 사용하였다. 파형 구조의 형상 변수가 배열 충돌제트의 횡방향 유동 억제에 미치는 영향을 제시하고 분석하였다.

공공부문 전력절감과 그린IT구현을 위한 데이터센터 내 열유동해석 (Flow and Thermal Analyses of Internet Data Center for Embodiment in Green IT)

  • 박상린;심장섭;송종철;문병주;박경우
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2010년도 춘계학술발표대회
    • /
    • pp.243-246
    • /
    • 2010
  • 최근 정보량의 급격한 증가로 데이터센터는 점차 대형화되고 있으며, 통합적으로 관리/운영되기 위해서는 전산실내 적절한 온도와 습도의 유지가 필수적이므로, 전산실내 에너지의 사용 효율을 극대화하기 위한 연구가 꾸준히 이루어지고 있다. 이 연구에서는 국내 공공부문의 대형 전산실을 모델로 선정하여 전산실 내 서버의 위치, 용량 그리고 냉각시스템 등을 고려하여 전산실내 열/유동특성을 수치적으로 규명함으로써, 에너지 효율 극대화를 추구하고 전력을 절감하여 저탄소 녹색성장과 그린IT 환경을 구축 하고자 한다. 이를 위하여 실제 측정한 환경 데이터를 바탕으로 전산유체역학(CFD)을 이용하여 3차원 비압축성, 정상상태의 열/유동특성을 예측한다. 또한 기존 및 개선된 전산실에 대한 비교결과를 바탕으로 새로운 열/유동조건을 도출하며, 이를 통하여 전산실 운영에 필요한 에너지 효율향상 방안을 제안하고자 한다. 연구 결과, 전산실 천장의 냉기유입부분과 열기배출부분으로 나뉘어 냉복도와 온복도를 형성하며, 내부 서버와 기타 각종 장비들의 발열 등으로 부분적인 열섬(Thermal island)현상이 나타났다. 이러한 열섬현상을 줄이고, 전산실내 환경을 최적화하기 위하여 찬공기 유입부분의 속도, 배출구의 유량, 그리고 냉/온 복도의 역할 변경 등 여러 가지 가능한 매개변수에 대한 연구가 필수적이다. 또한, 서버에서 발생한 고온의 공기를 배출하는 것이 전산실 내 적절한 온도구현에 효과적이며, 열섬현상을 방지하기 위해서는 이 부분에 차가운 공기의 유입이 필요하다는 것을 알 수 있었다.

배합수 냉각방법 및 지연제 사용에 따른 서중 원전콘크리트의 특성 (Properties of Hot Weather Nuclear Power Plant Concrete with Water Cooling Method and Retarding used)

  • 이승한;정용욱;장석수;여인동;최종오
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4602-4609
    • /
    • 2013
  • 온도차가 극심한 하절기와 동절기 콘크리트 타설의 경우 각종 균열의 발생, 콘크리트 품질불량, 내구성 및 강도저하 등 다양한 문제를 야기 시키고 있다. 특히 원전콘크리트의 경우 대량의 타설로 인한 4계절 연속시공이 이루어져 서중환경에서 콘크리트 품질관리에 많은 문제점이 발생되고 있는 실정이다. 이에 본 연구에서는 서중환경에서 많이 사용되어지는 프리쿨링 공법 중 배합수 냉각방법과 지연제 사용이 원전콘크리트의 특성에 미치는 영향을 검토하였다. 배합수 냉각방법은 냉수 $5^{\circ}C$와 Ice Flake 50% 치환사용 하였으며, 지연제 사용에 따른 원전콘크리트의 굳지 않은 콘크리트 및 경화 후 콘크리트의 특성을 검토하였다. 굳지 않은 콘크리트 특성으로는 슬럼프, 공기량, 응결시간 및 경화 후 압축강도를 측정하였으며, 단열거푸집을 제작하여 손실되는 열을 최소화시켜 각 온도조건하에서 수화열을 측정하였다. 실험결과, 슬럼프 및 공기량 경시변화 종료시간은 $20^{\circ}C$에서 120분, $40^{\circ}C$에서 40분으로 나타났으며, 관입 저항에 의한 응결시간은 배합수 냉각방법 및 지연제 사용 모두 초결과 종결을 지연시키는 것으로 나타났으나, 외기온도가 상승할수록 지연폭은 감소하는 것으로 나타났다. 수화열은 배합수 냉각방법 모두 최고온도의 저감과 도달시간을 지연시키는 것으로 나타났으나, 지연제 사용의 경우 최고온도 저감효과는 없는 것으로 나타났다. 또한 재령별 압축강도의 경우 3일, 7일의 초기재령에서 Plain과 비교하여 낮은 강도 값을 나타내었으나, 재령 28일에서는 설계기준강도를 모두 만족시키는 것으로 나타났다.