• 제목/요약/키워드: 압축기 일

검색결과 84건 처리시간 0.025초

Development of a New Commercial Grain Cooler (곡물냉각기의 개발)

  • 김동철;김의웅;금동혁;한종규
    • Food Science and Preservation
    • /
    • 제11권2호
    • /
    • pp.250-256
    • /
    • 2004
  • The objectives of this study were to develop a new commercial grain cooler suited to domestic weather and post-harvesting conditions for paddy, and to evaluate the performance. A prototype grain cooler capable of cooling paddy of 200 tons within 24 hours was developed. The grain cooler was designed to control the refrigeration capacity from 0 to 100% by controlling the capacity of compressor with unloading solenoid valve and by changing the flow rates of hot refrigerant gas flowing into reheater and evaporator from compressor. And a controller with one chip microprocessor was developed to control temperature and relative humidity of cooling air. The maximum cooling capacity of the grain cooler was 35,284㎉/hr at condensing/evaporating pressure of 16.5/3.6 kgf/$\textrm{cm}^2$. Maximum flow rate of cooling air was 120 ㎥/min at static pressure of 279 mmAq. The total maximum required power was 22.8㎾, and total required energy was saved from 26.7 to 33.3% of maximum power depending on operating conditions. The coefficient of performance of refrigeration devices and total coefficient of performance of the grain cooler were 4.71 and 1.8, respectively.

The Influence of KCl on the Hydration Property of OPC (시멘트의 수화 특성에 미치는 KCl의 영향)

  • Lee, Eui-Hak;Jeong, Chan-Il;Park, Soo-Kyung;Lee, Kyung-Hee
    • Journal of the Korean Ceramic Society
    • /
    • 제39권10호
    • /
    • pp.943-947
    • /
    • 2002
  • In order to examine the possibility of incineration of inderstrial by-product and wastes which contains a large percentage of chlorine by the cement kiln, measured heat of hydration, setting time, flow, change of length, compressive strength of OPC by the amount of KCl. The result was that a shorter setting time, a lower flow, a increasing the degree of initial shrinkage, a increasing of compressive strength before 3 days and decrease after 7 days by the induction period is shorter as promote the hydration with KCl.

Floor Field Behind an Axial Compressor Rotor ( I );Locus of Tip Leakage Vortex (축류압축기 회전익의 후방유동장(I) - 누설와류의 궤적)

  • 조강래;정의준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제15권3호
    • /
    • pp.963-969
    • /
    • 1991
  • 본 연구에서는 누설와류는 유동에 영향을 미치며 에너지 손실로 된다. 누설 와류에 의한 손실은 다른 원인에 의한 손실에 비교하여 그 비중이 크다. 따라서 누 설와류 특성을 이해하기 위해 설계영각(.alpha.=10.7˚)에서 절현비를 t/C=0.90와 2.71로 바꾸고, 또 절현비가 설계절현비 t/C=0.90일 경우에 영각을 설계 영각 .alpha.=10.7˚와 실 속점의 영각 .alpha.=18.9˚사이에서 바꾸어 회전익 후방의 회전유동장을 측정하여 누설와 류의 거동을 연구하였다.

Comparison of Microhardness and Compressive Strength of Alkasite and Conventional Restorative Materials (Alkasite와 기존의 수복 재료의 압축강도 및 미세경도 비교)

  • Lee, Kunho;Kim, Jongsoo;Shin, Jisun;Han, Miran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제47권3호
    • /
    • pp.320-326
    • /
    • 2020
  • The aim of this study was to compare compressive strength and microhardness of recently introduced alkasite restorative materials with glass ionomer cement and flowable composite resin. For each material, 20 samples were prepared respectively for compressive strength and Vickers microhardness test. The compressive strength was measured with universal testing machine at crosshead speed of 1 mm/min. And microhardness was measured using Vickers Micro hardness testing machine under 500 g load and 10 seconds dwelling time at 1 hour, 1 day, 7 days, 14 days, 21 days and 35 days. The compressive strength was highest in composite resin, followed by alkasite, and glass ionomer cement. In microhardness test, composite resin, which had no change throughout experimental periods, showed highest microhardness in 1 hour, 1 day, and 7 days measurement. The glass ionomer cement showed increase in microhardness for 7 days and no difference was found with composite resin after 14 days measurement. For alkasite, maximum microhardness was measured on 14 days, but showed gradual decrease.

Evaluation on In-Site Compressive Strength of High-Strength Concrete Mass Elements under Cold Weather (혹한기 고강도 콘크리트 매스부재의 현장 압축강도 평가)

  • Mun, Jae-Sung;Yang, Keun-Hyeok;Kim, Do-Gyeu
    • Journal of the Korea Institute of Building Construction
    • /
    • 제15권6호
    • /
    • pp.589-595
    • /
    • 2015
  • This study evaluated the in-site compressive strength development of high-strength concrete developed for the mass structures under cold weather condition. Two mock-up wall specimens with $2.0{\times}1.2{\times}1.0m$ in dimension were cured under an average temperature of $5^{\circ}C$. Core strengths measured at different locations of the mock-up walls were compared with the companion standard cylinder strengths. Test results revealed that the core strength of mock-up walls at an age of 3 days is higher by approximately 30% than the companion cylinder strength because of the high curing temperature effect generated from the heat of hydration of cementitious materials. Furthermore, comparisons with the prediction models based on maturity function confirmed that the effect of hydration heat on the curing temperature increase needs to be reflected to reasonably evaluate the on-site compressive strength development of concrete for mass elements.

A study on the development of MVR desalination plant and its performance analysis (MVR해수담수화플랜트의 개발 및 성능에 관한 연구)

  • Kim, Yeongmin;Chun, Wongee;Kim, Dongkook
    • Journal of Energy Engineering
    • /
    • 제25권3호
    • /
    • pp.59-65
    • /
    • 2016
  • MVR evaporation is a method of pressurizing the evaporating steam to raise its temperature with an electric compressor instead of burning fuel and reusing the heat source through the embraced heat exchanger to minimize energy use. MVR desalination system with wind power uses varying wind power instead of stable electricity and can flexibly control the volume of fresh water production. The present study introduces the design, construction and operation of a MVR desalination system of 30ton/day capacity. Experimental results, MVR compression ratio is higher than 1.5, temperature difference of the main heat exchanger is $5{\sim}7^{\circ}C$. This value shows the same performance as the designed value.

Hydration Characteristics of Liquid Red Mud Mixed Cement Paste Neutralized with Sulfuric Acid (황산으로 중화시킨 액상 레드머드를 혼입한 시멘트 페이스트의 수화특성)

  • Kang, Suk-Pyo;Hong, Seong-Uk;Kim, Sang-Jin;In, Byung-Eun
    • Journal of the Korea Institute of Building Construction
    • /
    • 제22권5호
    • /
    • pp.431-439
    • /
    • 2022
  • In this study, Neutralized red mud(LRM+S) at a pH of 6-8 was prepared by adding sulfuric acid to liquefied red mud(LRM) at a pH of 10~12. After adding LRM and LRM+S to the cement paste, the hydration heat, compressive strength, and hydration products were examined. The observed accumulated hydration heat revealed that the calorific value of the cement paste with LRM was low and its and peak was delayed when compared with that of plain cement paste(referred to as Plain), whereas the calorific value of the cement paste with LRM+S was similar to that of Plain. At the age of 28 days, the compressive strength of the cement paste with 20% LRM was 55% of the strength of Plain. Using X-ray diffraction, it was determined that the cement paste with 20% LRM exhibited a Ca(OH)2 peak after 3 days, whereas the cement paste with 20% LRM+S and Plain exhibited a Ca(OH)2 peak after an hour. Thus, the strength degradation of cementitious materials was improved by adding neutralized red mud prepared by adjusting the pH of highly alkaline LRM with sulfuric acid.

Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination (실내기 조합에 따른 3실형 열펌프의 냉방성능 실험연구)

  • Kwon, Young-Chul;Chun, Chong-Keun;Park, Youn-Chang;Ko, Kok-Won;Seo, Dong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제9권6호
    • /
    • pp.1487-1493
    • /
    • 2008
  • In order to investigate the cooling capacity of multi-heat pump applying an inverter compressor, the experiment on the cooling performance characteristics of heat pump with 3 indoor units was performed under the cooling standard and cooling low-temperature conditions. The system data were measured by the psychrometric calorimeter. The operation characteristics and the behavior of the cooling cycle of the heat pump with 3 indoor units were understood from the cooling capacity, COP, and P-h diagram by indoor-unit combination. The operating load and performance of the multi-heat pump depends on the indoor-unit combination. The cooling capacity and COP of the low temperature condition were larger than those of the standard one. Also the cycle was analyzed by using P-h diagram.

Process Simulation of HCNG Refueling System (HCNG 충전 시스템 공정모사)

  • Kim, Sang-Min;Han, Jeong-Ok;Lee, Yeong-Cheol;Lee, Joong-Seong;Kim, Yong-Cheol;Chae, Jeong-Min;Hong, Seong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • 제17권5호
    • /
    • pp.1-7
    • /
    • 2013
  • In this study, simulation work of HCNG refueling system was performed. The hydrogen was produced from steam reforming process by natural gas. The conversion of natural gas is increased as SCR is increased. but it was no significant difference more than 3 of SCR and fuel throughput is increased as GHSV is increased. Both conversion and fuel throughput levels was optimized when the $1700h^{-1}$ of GHSV. CNG was compressed from low pressure natural gas. For the mixing of $H_2$ and CNG is mixed with the high pressure conditions such as 400bar of $H_2$ and 250bar of natural gas. Single-stage compression was required more power than multi stage. So, multi stage compression was suggested for high pressure compression. We calculated the intermediate pressure to minimize total required power of compressors. The intermediate pressure for $H_2$ and natural gas were derived at 61 and 65 bar, respectively.

Design of Low Power H.264 Decoder Using Adaptive Pipeline (적응적 파이프라인을 적용한 저전력 H.264 복호기 설계)

  • Lee, Chan-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • 제47권9호
    • /
    • pp.1-6
    • /
    • 2010
  • H.264 video coding standard is widely used due to the high compression rate and quality. H.264 decoders usually have pipeline architecture by a macroblock or a $4{\times}4$ sub-block. The period of the pipeline is usually fixed to guarantee the operation in the worst case which results in many idle cycles and the requirement of high data bandwidth and high performance processing units. We propose adaptive pipeline architecture for H.264 decoders for efficient decoding and lower the requirement of the bandwidth for the memory bus. Parameters and coefficients are delivered using hand-shaking communication through dedicated interconnections and frame pixel data are transferred using AMBA AHB network. The processing time of each block is variable depending on the characteristics of images, and the processing units start to work whenever they are ready. An H.264 decoder is designed and implemented using the proposed architecture to verify the operation using an FPGA.