• Title/Summary/Keyword: 압전형 수신

Search Result 19, Processing Time 0.031 seconds

Measurement of Absolute Displacement-Amplitude of Ultrasonic Wave Using Piezo-Electric Detection Method (압전형 수신 기법을 이용한 초음파 절대변위진폭 측정)

  • Park, Seong-Hyun;Kim, Jongbeom;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process.

Accuracy of a direct estimation method for equivalent material properties of 1-3 piezocomposites (1-3형 압전복합재료 등가물성 직접 추출 기법의 정확도 분석)

  • Eunghwy Noh;Donghyeon Kim;Hyeongmin Mun;Woosuk Chang;Hongwoo Yoon;Seonghun Pyo;Kyungseop Kim;Yo-Han Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.377-387
    • /
    • 2023
  • This paper presents accuracy of a method that directly estimates equivalent properties of a 1-3 piezocomposite for modeling it into the single phase homogeneous piezomaterial. This direct estimation method finds individual components of a material property matrix based on the piezoelectric constitutive equations, which represent mechanical and electrical behaviors and their couplings. Equivalent properties on a single 1-3 piezocomposite hydrophone are derived, and their accuracy depending on pairing of the constitutive equations is investigated by comparing them with finite element analysis for the whole domain. The accuracy is related to elastic characteristics of a matrix polymer, and the error is analyzed so that some guidelines for correct estimation are suggested. Fidelity of estimated properties and equivalent modeling is shown in a stave scale including hydrophones and surrounding acoustic structures as well, and reduced computational cost is verified.

Design and Fabrication of PVDF Miniature Hydrophone and its Characteristic Evaluation (PVDF 극소형 수중 청음기의 제작 및 특성 평가)

  • Hyun Byung-Gook;Lee Gi-Wook;Ha Kang-Lyeol;Kim Moo-Joon;Bae Jong-Rim
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.381-384
    • /
    • 2000
  • 초음파 음장의 상대적인 변화를 측정하는데 사용하기 위한 극소형 수중 청음기를 제작하고 그 특성을 평가하였다. 압전체로서는 PVDF(Poly Vinylidene Di Fluoride) 고분자막을 사용하였으며, 수신 특성을 향상시키기 위해 임피던스 변환회로를 부가하였다. 본 논문에서는 설계된 수중 청음기의 초음파 수신특성을 Mason 등가회로에 의해 이론적으로 평가한 결과 및 극소형 수중 청음기의 제작 방법, 그리고 제작한 청음기의 초음파 수신 특성에 대하여 보고한다.

  • PDF

Development and Evaluation of the piezoelectric transducer for the transit-time ultrasonic flowmeters (외접형 초음파 유량센서용 압전 트랜스듀서의 개발 및 평가)

  • Lee Young-Jin;Im Jong-In
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.4 s.310
    • /
    • pp.30-34
    • /
    • 2006
  • To enhance the performance of the piezoelectric transducer for the transit-time type ultrasonic sensors, we investigated and verified the effect of it's size and raw materials using FEM(Finite Element Method) technique. Radiation angle of $25^{\circ}$ could be realized through the control of the matching layer's shape and its raw materials. Based on the results, the flowmeter is fabricated and characterized in real application, which thereby proves good sensitivity of 10 times better than current commercial one.

Measurement of Ultrasonic Nonlinearity Parameter of Fused Silica and Al2024-T4 (Fused Silica와 Al2024-T4의 비선형 파라미터 측정)

  • Kang, To;Lee, Taekgyu;Song, Sung-Jin;Kim, Hak-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • Nonlinearity parameter is an inherent property of materials measuring fundamental acoustic amplitude($A_1$) and second harmonic amplitude($A_2$). However, measurement of $A_1$ and $A_2$ has complex calibration procedure, many researchers prefer to measure relative nonlinearity parameter rather than absolute nonlinearity parameter. But, relative nonlinearity parameter is only detect materials degradation with various degradation samples, it is limited application in determining third order elastic constants of materials. Therefore, in this study, the piezoelectric detection method is adopted to measure absolute nonlinearity parameter due to experimental simplicity compare to capacitive detector. Linearity of measurement system is verified by $A_1^2vsA_2$ plot, and we measured ultrasonic nonlinearity parameters of fused silica and Al2024-T4.

Fabrication of a PMN-PZT needle hydrophone for photoacoustic imaging (광음향 영상화를 위한 PMN-PZT 바늘형 수중청음기 제작)

  • Fan, Xiaofeng;Cao, Yonggang;Ha, Kanglyeol;Kim, Moojoon;Kang, Hyun Wook;Oh, Junghwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.175-182
    • /
    • 2016
  • For application to several MHz photoacoustic imaging systems, a needle hydrophone was designed and fabricated by using PMN-PZT piezoelectric single crystal, and its characteristics were evaluated through comparison with a commercial PVDF(Polybinylidene Fluoride) hydrophone of which receiving sensitivity is known. The simulation using the KLM model results show that the peak receiving impulse response for $50{\Omega}$ terminating impedance of the fabricated hydrophone is -261.6 dB re $1V/{\mu}Pa$ and the frequency response is relatively flat over 2 ~ 12 MHz with fluctuation less than 5 dB. The measurement results using tone burst signals also show that it has higher (ave. 10.9 dB) sensitivity than the commercial hydrophone in 2 ~ 8 MHz, and the receiving sensitivity of $-255.8{\pm}2.8$ dB re $1V/{\mu}Pa$ was measured for the fabricated hydrophone. In addition, it is known that the photoacoustic signals and the image of a hair obtained by a mechanical scanned photoacoustic imaging system with the fabricated hydrophone were bigger and better than those obtained with the commercial hydrophone.

Design of a Multimode Piezoelectric Spherical Vector Sensor for a Cardioid Beam Pattern (심장형 빔 패턴을 위한 다중모드 압전 구형 벡터센서 설계)

  • Lim, Youngsub;Lee, Jaeyoung;Joh, Cheeyoung;Seo, Heeseon;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.32-42
    • /
    • 2013
  • Typical underwater piezoelectric spherical sensors are omni-directional, thus can measure the scalar quantity sound-pressure-magnitude only with the limitation not being able to measure the direction of the incoming wave. This paper proposes a method to simultaneously measure both the magnitude and direction of the sound wave with the spherical sensor. The method divides the piezoceramic sphere of the sensor into eight elements, and distinguishes the magnitude and direction of the sound pressure by combining the output voltage of the elements in a particular manner. Further, through the analysis of the sensitivity variation in relation to the structural parameters like radius and thickness of the piezoceramic sphere, we have suggested the way to improve the sensitivity of the vector sensor.

Equivalent Circuit Modeling of Underwater Acoustic Piezoelectric Transducer (수중 음향 압전 트랜스듀서의 등가 회로 모델링)

  • Joh, Chee-Young;Seo, Hee-Seon;Lee, Jung-Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.77-82
    • /
    • 1996
  • In this paper an identification method is presented to obtain the equivalent electric model of a sandwitch type piezoelectric transducer. Unknown parameters related to the equivalent circuit are identified by solving a nonlinear optimization problem which can minimize an error between the experimental and analytical admittances in air. The proposed method is applied to an example transducer. The validity of equivalent circuit model is demonstrated by the comparison between the experimental measurements and analytical calculations of transmitting voltage response(TVR) and receiving voltage response(RVS).

  • PDF

Design and Evaluation of Ultrasonic Flowmeter for High Temperature Using Finite Element Method (유한요소법을 이용한 고온용 초음파 유량센서의 설계 및 평가)

  • Lee, Joo-Hee;Kim, Chang-Il;Kim, Chul-Min;Paik, Jong-Hoo;Cho, Jeong-Ho;Jeon, Myeong-Pyo;Jeong, Young-Hun;Lee, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.19-19
    • /
    • 2010
  • 현재 산업에서 높은 정밀성과 설치의 간편함으로 이용량이 증가하고 있는 초음파 유량계는 압전진동자를 사용하여 측정을 한다. 일반적으로 초음파 유량계에서 초음파를 발생하고 수신하는 압전 세라믹 진동자의 경우 대부분 $200^{\circ}C$ 이상의 고온에서는 사용이 불가능하다. 따라서 고온에서의 이용을 위한 사용가능 온도의 영역을 개선하기 위한 조성이나 구조적인 변화가 필요하였고, 조성변화에 있어서는 한계가 있기 때문에 구조 측면에서 접근하고자 하였다. 초음파 유량계의 구조에 있어 외접형 도파관 방식을 선택하였으며, 도파관의 길이, 방열판의 개수, 재질 등의 변수에 대하여 시뮬레이션을 하였다. 시뮬레이션 결과를 바탕으로 얻어진 결과에 대하여 샘플을 제작하였으며, 압전 진동자에 도달되는 온도를 평가 하였을 시 방열판에 대한 온도감소효과를 얻을 수 있었다.

  • PDF

Thickness Measurements of the Base Concrete by the Impact-Resonance Test (탄성파 충격공지법에 의한 기초 콘크리트의 두께 측정)

  • 김영환;이세경;김호철
    • Magazine of the Korea Concrete Institute
    • /
    • v.3 no.3
    • /
    • pp.121-128
    • /
    • 1991
  • Thicknesses of the hase concrete blocks supportmg large machmes were estimated by analyzing the res- 0 ¬nance modes of mechanical Vibrations The vibration was produced by the mechanical impact with steel ball drop and detected by a wideband comcal piezoelectric transducei. The detected signals were analyzed by FFT and thicknesses of specimen were determined by the resonant frequency of vibratIon. For the layered concrete block, the estimated thickness is dependent on the acoustic reflective index at the boundary between layers. The estimated thickness up to 100em were in goo:l agreement with the real value. In additlOn. this technique could be applicable to the estimation of the bondmg status of the layered structures.