• 제목/요약/키워드: 압전진동모드

Search Result 150, Processing Time 0.022 seconds

Influences of the Defective Piezo-Elements of a Medical Ultrasonic Probe on Transient Acoustic Fields and B-Mode Images (의료용 초음파프로브의 압전소자 결함이 과도음장과 B-모드 영상에 미치는 영향)

  • Choi, Kwang-Yoon;Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Soon;Yang, Jeong-Hwa;Kang, Gwan-Suk;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.476-482
    • /
    • 2010
  • The ultrasonic transient fields and B-mode images of a point target which were simulated for a medical ultrasonic probe with a few defective piezo-elements were compared with those for a normal probe. The present study considered a 3.5 MHz linear array probe whose acoustic beam was formed by the 64 active elements of total 192 elements. The results showed that the maximum amplitude and -3 dB width of the acoustic fields by main-lobes decreased linearly as the defective element number increased from one to four. However, the depths of foci remained almost unchanged, and the pressure differences between main-lobes and side-lobes tended to decrease due to rise in pressures in side-lobes. Such changes in ultrasonic fields affected the B-mode images of point targets. So the artifacts were formed in the right and left side of the target, and the lateral spatial resolutions were decreased while the axial resolution was almost the same.

Active Vibration Control of Multi-Mode Forced Vibration Using PPF Control Technique (PPF 제어기법을 이용한 다중 모드 강제 진동의 능동 진동 제어)

  • 한상보;곽문규;윤신일
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.1007-1013
    • /
    • 1997
  • This paper presents active vibration control scheme of multi-mode forced vibration using piezocetamic sensors and actuators. The control scheme adopted is the Positive Position Feedback (PPF) control. Among various vibration control techniques. PPF control technique makes use of generalized displacement measurements to accomplish the vibration suppression. Two independent controllers are implemented to control the first and the second modes of the beam under external excitation. Experimental results for various damping ratios and feedback gains of the PPF controllers are compared with respect to the contorl efficiency. The results indicate that steady state vibration under wide band excitation can be controlled effectively when multiple sets of PZT sensors and actuators were used with PPF control technique.

  • PDF

Active Vibration Control of Smart Hull Structures (지능형 Hull구조물의 능동 진동제어)

  • Sohn, Jung-Woo;Choi, Seung-Bok;Kim, Heung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.192-195
    • /
    • 2005
  • In this study, dynamic characteristics of an end-capped hull structure with surface bonded piezoelectric actuators are studied. Finite element modeling is used to obtain practical governing equation of motion and boundary conditions of smart hull structure. Modal analysis is conducted to investigate the dynamic characteristics of the hull structure. Piezoelectric actuators are attached where the maximum control performance can be obtained. Active controller based on Linear Quadratic Gaussian (LQG) theory is designed to suppress vibration of smart hull structure. It is observed that closed loop damping can be improved with suitable weighting factors in the developed LQG controller.

  • PDF

Vibration Suppression of Hull Structure Using MFC Actuators (MFC 작동기를 이용한 Hull 구조물의 진동 저감)

  • Sohn, Jung-Woo;Kim, Heung-Soo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.587-595
    • /
    • 2007
  • Performance evaluation of advanced piezoelectric composite actuator is conducted with its application of structural vibration control. Characteristics of MFC(macro fiber composite) actuator are investigated by comparing traditional piezoceramic patch actuator. Finite element modeling is used to obtain equations of motion and boundary effects of smart hull structure with MFC actuator. Dynamic characteristics of the smart hull structure are studied through modal analysis and experimental investigation. LQG control algorithm is employed to investigate active damping of hull structure. It is observed that vibration of hull structure is suppressed effectively by the MFC actuators.

Vibration Suppression of Hull Structure Using MFC Actuators (MFC 작동기를 이용한 Hull 구조물의 진동 저감)

  • Sohn, Jung-Woo;Kim, Heung-Soo;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1119-1124
    • /
    • 2007
  • Performance evaluation of advanced piezoelectric composite actuator is conducted with its application of structural vibration control. Characteristics of MFC (macro fiber composite) actuator are investigated by comparing traditional piezoceramic patch actuator. Finite element modeling is used to obtain equations of motion and boundary effects of smart hull structure with MFC actuator. Dynamic characteristics of the smart hull structure are studied through modal analysis and experimental investigation. LQG control algorithm is employed to investigate active damping of hull structure. It is observed that vibration of hull structure is suppressed effectively by the MFC actuators.

  • PDF

Vibration Control of Stiffened Hull Structure Using MFC Actuator (MFC 작동기를 이용한 보강 Hull 구조물의 능동 진동 제어)

  • Jeon, Jun-Cheol;Sohn, Jung-Woo;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.273-278
    • /
    • 2011
  • This work presents an active vibration control of a stiffened hull structure using a flexible macro fiber composite (MFC) actuator. As first step, the governing equation of the hull structure is derived in a matrix form and its dynamic characteristics such as natural frequency are obtained via a finite element analysis (FEA). The natural frequencies obtained from the FEA are compared with those determined from experimental measurement. After formulating the control model in a state space representation, an optimal controller is designed in order to attenuate the vibration of the stiffened hull structure. The controller is then empirically realized through dSPACE and control responses are evaluated in time domain.

  • PDF

Vibration Control of Stiffened Hull Structure Using MFC Actuator (MFC 작동기를 이용한 보강 Hull 구조물의 능동 진동 제어)

  • Jeon, Jun-Cheol;Sohn, Jung-Woo;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.643-649
    • /
    • 2011
  • This work presents an active vibration control of a stiffened hull structure using a flexible macro fiber composite(MFC) actuator. As first step, the governing equation of the hull structure is derived in a matrix form and its dynamic characteristics such as natural frequency are obtained via a finite element analysis(FEA). The natural frequencies obtained from the FEA are compared with those determined from experimental measurement. After formulating the control model in a state space representation, an optimal controller is designed in order to attenuate the vibration of the stiffened hull structure. The controller is then empirically realized through dSPACE and control responses are evaluated in time domain.

Vibration Control of Engine Mount Utilizing Smart Materials (지능재료를 이용한 엔진 마운트의 진동제어)

  • Song, Hyun-Jeong;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.297-300
    • /
    • 2005
  • This paper presents vibration control of an engine mount for a passenger vehicle utilizing ER fluid and piezoelectric actuator. The proposed engine mount can be isolated the vibration of wide frequency range with many types of amplitude. The main function of ER fluid is to attenuate vibration for low frequency with large amplitude, while the piezoelectric actuator is activated in hish frequency range with small amplitude. A mathematical model of the engine mount is derived using Hydraulic model and mechanical model. After formulating the governing equation of motion, then field-dependent dynamic stiffness of the engine mount is evaluated for various engine speed and excitation amplitude conditions. Then robust controller is designed to attenuate vibration of wide range frequency component. Computer simulation is undertaken in order to evaluate the vibration control performance such as transmissibility magnitude in frequency domains.

  • PDF

A study on High Frequency DC-DC Converter Drive using a Piezoelectric Transformer (압전 변압기를 이용한 고주파 DC-DC 컨버터 구동에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Choi, Gi-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.476-484
    • /
    • 2010
  • Recently, as the piezoelectric transformer technology develops, piezoelectric transformer may become a variable alternative to magnetic transformers in various applications. Because it was have to favorable characteristics such as electromagnetic-noise free, compact size, higher efficiency, and superior power density, linkage flux, noiseless, etc. its resonance frequency was used to output waveform of a sine wave. In this paper, the switching mode power supply of about 87.2[KHz] is driven by the multilayer thickness vibration mode piezoelectric transformer and the DC to DC converter drive circuit using an electrical equivalent circuit is proposed. Also, it was possible to drive power source device of the high-luminance LED by propose circuits.

PZT 위상변조기를 이용한 광섬유 음향센서의 신호안정화

  • 서상준;이두희;조문재;은희준
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1988.06a
    • /
    • pp.112-116
    • /
    • 1988
  • Homodyne 방식으로 동작하는 광섬유 간섭계 센서는 주위 온도의 변화나 진동등에 의하여 시노의 크기가 불규칙하게 변화된다. 따라서 광섬유 간섭계가 직작조건에서 동작하도록 하여 감도를 최대로 유지시켜야 한다. 본연구에서는 원통형 압전자소자에 단일모드 광섬유룰 감아서 변환율 K=1.07$\pi$/V의 위상변조기를 만들고, 이를 이용하여 능동위상추적(active phase tracking)방식의 신호안정화 장치를 제작하고 광섬유 간섭계 센서의 공기중 읍압반응을 조사하였다.

  • PDF