A study on designing a level gauge for cryogenic liquefied storage vessel by using a differential pressure sensor (차압센서를 이용한 극저온 액화가스 저장용기의 액면측정장치 설계에 관한 연구)

  • Choi, Dong-Joon;Lim, Hyung-Il;Doh, Deog-Hee;Cho, Jong-Rae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.384-390
    • /
    • 2013
  • The sizes of cryogenic vessels and storage tanks are becoming bigger due to strong demands from semiconductor and LCD industry as well as high-tech electronic industry. Conventional level and pressure gauges used for cryogenic vessels were analog types which made exact measurement difficult for the remained quantity at lower levels due to their poor accuracy. In this study, a design for a digital type gas level gauge which can measure the pressure and level inside of the cryogenic liquefied gas storage tanks has been proposed by using a differential pressure sensor, in which the measured data are monitored by a host PC and are transferred to a mobile printer for data confirmation at local station.

A Development of A Gas Mechanical Pulsator (압력 섭동 장치 설계/제작 및 검증시험)

  • Kim, Tae-Woan;Hwang, Oh-Sik;Ko, Young-Sung;Jung, Se-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.3
    • /
    • pp.50-57
    • /
    • 2009
  • A gas mechanical pulsator is developed for the study of combustion instabilities in various combustors such as LRE combustor. First, it shows that the mass flow rates and the perturbation frequencies can be successively controlled by the inlet pressure and the rotating speed of a rotating disk with many holes. Second, the device is used as an acoustic amplification source as a substitute for the speaker in the previous acoustic tests and its results show almost the same resonant frequency and damping characteristics compared with the previous results. In conclusion, the result shows that it can be used as a substitute for a speaker in the studies of LRE combustion instabilities, which has a flow and no limitation of amplification, and a device for making a perturbation source in gas flow.

Development of Pressure Monitoring System and Pressure Changes during Kimchi Fermentation (김치발효 중 가스압력 변화와 압력측정시스템의 개발)

  • Lee, Young-Jin;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.686-689
    • /
    • 1990
  • For the monitoring of kimchi fermentation states, pressure detecting sensor and monitoring device were designed and fabricated. The system was consisted of an air tight fermenting tube(31.5 ml), strain gauge type pressure sensor and signal processing device built with operational amplifier and A/D converter, and interfaced to personal computer. Chiness cabbage kimchi was fermented in the plastic container($150{\times}220{\times}160mm$) at $25^{\circ}C\;and\;30^{\circ}C$. The fermentation was monitored with fermenting tubes containing kimchi. The pressure based kimchi fermentation curve was constructed and showed a typical kimchi curing curve having 2 stepwise pressure increasing pattern.

  • PDF

Experimental Study on Peak-Pressure Variation Due to Compression by Using RCM (급속 압축장치(RCM)의 압축 조건에 따른 최대 압력 변화에 관한 실험적 연구)

  • Kim, Hye-Min;Kim, Hak-Young;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.197-204
    • /
    • 2011
  • RCM is used to clarify the complex phenomena of engine combustion. In order to describe engine combustion, several significant experimental studies are considered. Prediction of the peak pressure is very important since it has a significant influence on engine combustion. In addition, peak-temperature variation can be calculated from the measured peak pressure by using the fundamental thermodynamic relation. When the RCM is in operation, heat transfer occurs through the cylinder wall. Because of this phenomenon, it is difficult to determine the peak pressure without employing the case by case experimental method. The goal of this study is to evaluate the peak pressure analytically. We conduct an experiment to confirm the relationship between the peak pressure and some parameters. Using the results of the peak pressure variation experiment, we develop a general equation that be used to calculate the peak pressure as a function of operation time and compression ratio.

Flow Characteristics in the Downstream Region of a Butterfly Valve with Various Disk Opening Angle (디스크 회전각에 따른 버터플라이 밸브 하류에서의 유동특성)

  • Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.267-272
    • /
    • 2006
  • Butterfly valves have been used for shut-off and throttling-control application in many industrial fields. Recently, they are frequently used for cooling water, oil system and ballast piping system of many larger vessels. They are especially suited for flow throttling control of heat exchangers in engine room. Measurement by the PIV(Particle Image Velocimetry) was conducted to investigate the flow characteristics of butterfly valve inserted within circular pipe. Flow behaviors such as instantaneous and time-mean velocity vectors are investigated. Furthermore, to reveal systematic performance of the butterfly valve, wall pressure was measured at 6 points along the pipe by digital manometer. As the valve position moves to the closed side, flow separation increases and persists its tendency downstream until smoothly uniform flow developed. The pressure loss is found to be about zero for the disk open angles less than 45 degrees, but is substantially increased for those larger than 60 degrees.

  • PDF

Effectiveness Evaluation of Displacement Accommodatable Pressure Measuring Jig for Quality Assessment of Pressure Application Device (압력 인가 장치의 품질관리를 위한 변위 수용이 가능한 압력 측정용 지그의 유효성 평가)

  • Mun, Chang-Su;Jun, Sung-Chul;Noh, Si-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • Recently, a variety of electric anesthetics devices have been developed and used in clinical practice to reduce the fatigue of the operator during local anesthesia for dental procedures and to compensate for the disadvantages of manual anesthesia device. In this electric anesthesia injection device, the accurate and constant delivery of pressure for drug infusion is a very important performance factor. In order to evaluate the accuracy of the transfer pressure, a small pressure gauge using a load cell is often used, but since the elastic body inside the load cell may not be able to accommodate a sufficient displacement, an error may occur when evaluating pressure performance. For these reasons, in this study, we proposed and evaluated a silicon-chrome steel (Si-Cr steel) spring jig that can accommodate relatively large displacements that can be used when evaluating the performance of a pressure-controlled pressure application device using a load cell type pressure gauge. As a result of the pressure transmissibility test and repeated measurement results using a commercial dental anesthesia injection device, a more stable result was obtained when using a spring jig, and it was confirmed that the frequency of abnormally high measurement was reduced.

A Study on the Effect of Atomization of Pressure Nozzle with Blower - Air (압력식 노즐에서 송풍공기가 미립화에 미치는 영향에 관한 연구)

  • Koh, Kyoung-Han;Lim, Sang-Ho
    • Journal of Digital Convergence
    • /
    • v.10 no.5
    • /
    • pp.283-288
    • /
    • 2012
  • This study was undertaken to investigation the spray characteristics of the twin fluid atomization nozzle system. The light oil was injected at the normal temperature and injection pressure was 5 bar - 10 bar by 1 bar and volume flow was 0.5, 1.0 and 2,0 mmH2O(X10-2). We measured the SMD of sprayed droplet to study spray characteristics. The following conclusions were reached from the results of these study. 1. The more injection pressure increased, the more SMD decreased. 2. The more measuring distance between pressure nozzle tip and analyser beam increased, the more SMD increased. 3. SMD of the blower-air-added injection system were shown, increasing volume flow decreased respectively. The result of this study indicated the blower-air-added injection system induced beneficial changes in SMD. And it will be considered important indicator for spray characteristics design and performance evaluation of twin fluid atomization nozzle system.

Waterhammering on Pump Pipeline Systems (펌프 관로계의 수격현상)

  • 김경엽;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.331-355
    • /
    • 1997
  • 본 연구에서는 에어챔버가 설치된 펌프관로계에서 수격현상에 대한 현장실험을 실시하고, 에어챔버의 입력변수 및 설계인자가 수격현상에 어떠한 영향을 미치는지 수치계산과 실험을 통하여 조사한 후 다음과 같은 결론을 얻었다. (1) 수치계산에 사용된 입력변수중 폴리트로프지수, 오리피스 유량계수, 압력파 전파속도순으로 수격현상에 대한 영향이 크게 나타났으며, 수치계산은 이 변수값이 각각 1.3, 0.7, 1,050m/s일 때 측정된 압력변동 및 공기체적변화를 가장 잘 모사하였다. (2) 에어챔버내 초기공기체적이 증가하면 압축공기의 압력변화율이 작아지기 때문에 수격현상의 주기는 길어지고, 관로내 압력변화는 감소하였다. 측관에 설치한 오리피스 내경을 줄임으로써 상승압은 상당히 완화되었으며, 시간이 지남에 따라 수격작용도 보다 빨리 감쇄되었다. 수치계산결과는 수격현상의 1-2주기까지 측정값과 비교적 잘 일치하였으며, 펌프관로계에 작용하는 최대.최소압력 및 그 발생시간도 합리적으로 예측되었다. (3) 수치계산은 측정된 과도특성 값들을 약 5%이내의 오차로 예측하였으며, 개발된 전산프로그램은 실제 펌프관로계에 대한 수격완화장치를 설계하는데 매우 유용하게 사용될 것으로 판단된다.

  • PDF

Study on the Modeling Technique for Prediction about Pressure Drop of an Intravenous Lung Assist Device (혈관 내 폐 보조장치의 압력손실 예측을 위한 모델링기법에 관한 연구)

  • 김기범;권대규;정경락
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.293-299
    • /
    • 2003
  • In this paper, the correlation of Pressure drop about the Newtonian and non-Newtonian fluid was investigated experimentally for vibrating intravascular lung assist device (VIVLAD) and we determined correlation equation to make a prediction about Pressure drop for designing VIVLAD. Design conditions to predict the pressure drop of the modules were studied through an experimental modeling before inserting the artificial lung assist device into as venous. Experiments were performed by distilled water, glycerol/water mixed solution(40% glycerol) of Newtonian fluids. and the bovine blood of non-Newtonian fluids. These fluids were flowed outside and parallel of hollow fiber membranes. Also we measured pressure drop according to the number of the fiber membranes which ware inserted into the inside diameter of shell of 3 cm, and developed the prediction equations by curve fitting method based on correlation between the experimental pressure drop and the frontal area or the packing density of device. The result showed that the Pressure drop and the friction factor of the water/glycerol mixed solution were similar to that of bovine blood. It was showed that the water/glycerol mixed solution (40% glycerol) could be used for measuring the pressure drop and the friction factor instead of the bovine blood. Also, we could estimate the prediction equation of pressure drop and friction factor as the function of Packing density at the number of hollow fibers. We obtained the reliance of the prediction equations because the pressure drop and the friction factor measured from the experiments were similar to that from the prediction equation. These results may be used to further usefulness for the design of VIVLAD.

Estimation of Stroke Volume Based on Air Pressure in Air Tube with Pneumatic Pulsatile Ventricular Assist Device (공압식 박동형 심실보조장치에서 공압관 내 공기압에 따른 박출량 추정)

  • Kang, Yu Min;Lee, Jin Hong;Her, Keun;Choi, Seong Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.971-974
    • /
    • 2014
  • A ventricular assist device (VAD) is used for bridge to heart transplantation and heart diseases. Knowing the status of a pneumatic pulsatile VAD when implanting it into the body is important: when the velocity of blood flow through the VAD is slow, a thrombus may occur, and thrombosis can be fatal to a patient. In order to determine the state of a VAD, various sensors need to be implanted. Because this introduces the risk of infection and difficulties with sensor management, we developed a method for estimating the state of a VAD indirectly via the pressure in an air tube that can be measured in vitro. We compared the measured values to in vitro experimental results. The estimated and measured values showed some errors, but the accuracy can be improved by refining the estimation process to minimize the risk of infection.