• Title/Summary/Keyword: 압력제어 솔레노이드 밸브

Search Result 37, Processing Time 0.027 seconds

A Development of Proportional Pressure Control Valve (비례압력제어밸브 개발)

  • Yun, S.N.;Ahn, B.K.;Ryu, J.S.;Ham, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1041-1046
    • /
    • 2004
  • A proportional pressure control valve has a nonmagnetic ring which is inserted in between a coil and plunger and it can get attraction force in proportion to input current by an influence of control cone. Therefore, a proportional pressure control valve is applied to a servo system as substitution of servo valve and an on-off solenoid valve widely because control of a high level is possible and pollution level is low. The purpose of this study is to develop domestic model of a proportional pressure control valve, and a test model was designed and manufactured through valve system analysis and finite element analysis. And comparison between results of theoretical analysis and static / dynamic characteristics test were carried out on a manufactured test model, and it was confirmed that it has excellent performance in comparison with other foreign products.

  • PDF

FEA(Finite Element Analysis) Study for Electronic Hydrogen Regulator of Confidentiality Improvement (전자식 수소레귤레이터 기밀성 향상을 위한 FEA 연구)

  • Son, Won-Sik;Song, Jae-Wook;Jeon, Wan-Jae;Kim, Seung-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.175-181
    • /
    • 2019
  • In the case of a conventional single stage decompression regulator used for large depressurization in the hydrogen fuel cell system of a fuel cell electric vehicle (FCEV), problems can arise, such as pulsation, slow response, hydrogen brittleness, leakage, high weight, and high cost due to high decompression. Most of these problems can be overcome easily using two decompression mechanisms (two-stage structures). In addition, a wide outlet-pressure control range can be secured if an electronic solenoid is applied to the second decompression. Accordingly, it is necessary to improve the precision of the outlet pressure of a two-stage pressure-reducing regulator and develop techniques, such as leakage prevention, durability, light weight, and price reduction. Therefore, to improve the outlet pressure accuracy and prevent leakage, the structural part before and after decompression to improve the air tightness were divided and the analysis was carried out assuming that the valve part was closed (open ratio: 0%) after each initial internal pressure application.

A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip (랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법)

  • Han, Su-Dong;Kim, Guk-Bae;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

A Study on Falling Pressure Surge of ABS Using High Frequency PWM Control (고주파수 PWM제어를 이용한 ABS의 맥동 저감에 관한 연구)

  • Lee, Yong-Joo;Kim, Byeong-Woo;Park, Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.3
    • /
    • pp.38-44
    • /
    • 2003
  • The solenoid valve in ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz high speed pulse width modulation. When the valve is switched from open state to closed state, noise and vibration due to pressure surge phenomena in the hydraulic line and wheel cylinder are made. In this study, we identify Pressure surge phenomenon in the braking process of a ABS, and investigate the way to reduce the phenomenon. For the purpose of theoretical analysis on the pressure surge in the closed state hydraulic line, characteristic curve method based on wave equation was utilized. To reduce the surge, high frequency control of 20kHz was attempted. The result showed that the surge pressure of 50% was reduced compared to one observed in the low frequency control. Duty variation of high frequency can control current of solenoid valve and prevent sudden change of displacement.

Study of Failure Examples for Emission Gas Control System in Gasoline Engine (가솔린 엔진 배출가스 제어장치에 대한 고장사례 고찰)

  • Lee, Il Kwon;Lee, Jong Ho;Lee, Young Suk;Youm, Kwang Wook;han, Jae Oh;Lim, Ha young
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The purpose of this paper is to study for the emission gas control of passenger car. The first example, the PCSV never open when operating condition, but it opened by causing malfunction because of trouble. As a result, the purge gas entered into surge tank, a mount of fuel was displayed with excessive supply on tester. Therefore, it certified the bad-condition of the engine when idling by decreasing of fuel injection quantity from engine ECU. The second example, the hose activating a EGR valve didn't supply the vacuum pressure because of assembling the other part. Thus, it knew the bad-condition of engine that the EGR valve would not work normally by leaking with the other port. The third example, as the rear oxygen sensor of two sensor were fault-installing by changing the sensor of other a car it could not detect of oxygen quantity. Finally, it found the phenomenon of abruptly decreasing vehicle speed when braking a car. Therefore, the system including with emission control has to drastically manage by maximizing condition to role decreasing the emission gas.

Pressure Regulator for Piezoelectric Valve (압전 밸브용 압력 레귤레이터)

  • Yun, S.N.;Kim, C.Y.;Seo, S.W.;Park, J.H.;Ham, Y.B.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.2
    • /
    • pp.1-6
    • /
    • 2006
  • The pressure regulator which is used for controlling the reducing pressure in the piezoelectrically driven pneumatic valve has been studied. The pneumatic valve of this study object is 2-stage type and consists of a piezoelectric actuator, a controller, a poppet valve and a pressure regulator. Nominal flow of 50 lpm, maximum operating pressure of 0.9MPa and frequency characteristic of 10Hz and over are required in this pneumatic valve, but the pressure regulator is needed because piezoelectric actuator has no ability to control the pressure of 0.9MPa directly. In this study, bimorph type PZT actuator of $25.2mm(L){\times}7.2mm(W){\times}0.5mm(H)$ with constant of $-220{\times}10-12$ CN-1 was proposed and investigated. Maximum operating force of 0.052 N and maximum displacement of $63{\mu}m$ were gotten from the fabricated PZT actuator. From the analysis results, the orifice diameter of 0.6mm for a piezoelectric actuator was derived and then the pressure regulator which can be operated under 0.15 MPa easily was designed and manufactured. Performance and effects of design parameters were simulated by the Simulink of Matlab software, and it was confirmed that the performance characteristics of manufactured pressure regulator are superior in the common use pressure range of 0.5 MPa to 0.7 MPa. The results show that the proposed pressure regulator is suitable for the pneumatic valve with a PZT actuator.

  • PDF

A Study on Implemetation of Non-invasive Blood Pressure (비침습적 혈압 측정 시스템 구현에 관한 연구)

  • 노영아;이종수;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.451-454
    • /
    • 2000
  • Invasive methode and Non-invasive methode are used in blood pressure measurement. The Invasive methode can Set the correct measured blood pressure but, it has patient feels uncomfortable. So most of cases use Non-invasive methode. The Oscillometric method is commonly apply to modem electric sphygmomanometer and using various algorithm. In this paper describe about a algorithm it control and to determinate the cuff pressure, and filtering that data for measure the blood pressure. The communicating with personal computer can pressure deflation is by Solenoid valve and it uses RS-232 system in packet communication. The main using algorithm for blood pressure measurements are maximum amplitude algorithm and oscillometric algorithm. MAA(maximum amplitude algorithm) has various measured oscillation it depend on patient's age, height, weight and arm circumference size. In this paper, 1 studied the various measured oscillation apply to characteristic ratio and can get the result of systolic blood pressure, diastolic blood pressure, mean blood pressure. It was not used same ratio to measuring oscillation. In the MAA(maximum amplitude algorithm), we hope for reduce the difference with the real blood pressure and the measured blood pressure, when it applied with various specific ratio.

  • PDF