• Title/Summary/Keyword: 압력(pressure)

Search Result 10,447, Processing Time 0.037 seconds

Preparation of Pure CO2 Standard Gas from Calcium Carbonate for Stable Isotope Analysis (탄산칼슘을 이용한 이산화탄소 안정동위원소 표준시료 제작에 대한 연구)

  • Park, Mi-Kyung;Park, Sunyoung;Kang, Dong-Jin;Li, Shanlan;Kim, Jae-Yeon;Jo, Chun Ok;Kim, Jooil;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • The isotope ratios of $^{13}C/^{12}C$ and $^{18}O/^{16}O$ for a sample in a mass spectrometer are measured relative to those of a pure $CO_2$ reference gas (i.e., laboratory working standard). Thus, the calibration of a laboratory working standard gas to the international isotope scales (Pee Dee Belemnite (PDB) for ${\delta}^{13}C$ and Vienna Standard Mean Ocean Water (V-SMOW) for ${\delta}^{18}O$) is essential for comparisons between data sets obtained by other groups on other mass spectrometers. However, one often finds difficulties in getting well-calibrated standard gases, because of their production time and high price. Additional difficulty is that fractionation processes can occur inside the gas cylinder most likely due to pressure drop in long-term use. Therefore, studies on laboratory production of pure $CO_2$ isotope standard gas from stable solid calcium carbonate standard materials, have been performed. For this study, we propose a method to extract pure $CO_2$ gas without isotope fractionation from a solid calcium carbonate material. The method is similar to that suggested by Coplen et al., (1983), but is better optimized particularly to make a large amount of pure $CO_2$ gas from calcium carbonate material. The $CaCO_3$ releases $CO_2$ in reaction with 100% pure phosphoric acid at $25^{\circ}C$ in a custom designed, evacuated reaction vessel. Here we introduce optimal procedure, reaction conditions, and samples/reactants size for calcium carbonate-phosphoric acid reaction and also provide the details for extracting, purifying and collecting $CO_2$ gas out of the reaction vessel. The measurements for ${\delta}^{18}O$ and ${\delta}^{13}C$ of $CO_2$ were performed at Seoul National University using a stable isotope ratio mass spectrometer (VG Isotech, SIRA Series II) operated in dual-inlet mode. The entire analysis precisions for ${\delta}^{18}O$ and ${\delta}^{13}C$ were evaluated based on the standard deviations of multiple measurements on 15 separate samples of purified $CO_2$. The pure $CO_2$ samples were taken from 100-mg aliquots of a solid calcium carbonate (Solenhofen-ori $CaCO_3$) during 8-day experimental period. The multiple measurements yielded the $1{\sigma}$ precisions of ${\pm}0.01$‰ for ${\delta}^{13}C$ and ${\pm}0.05$‰ for ${\delta}^{18}O$, comparable to the internal instrumental precisions of SIRA. Therefore, we conclude the method proposed in this study can serve as a way to produce an accurate secondary and/or laboratory $CO_2$ standard gas. We hope this study helps resolve difficulties in placing a laboratory working standard onto the international isotope scales and does make accurate comparisons with other data sets from other groups.

Early Clinical Experience in Aortic Valve Replacement Using On-X$^{circledR}$Prosthetic Heart Valve (On-X$^{circledR}$ 기계판막을 이용한 대동맥판 치환술의 조기 임상 경험)

  • 안병희;전준경;류상완;최용선;김병표;홍성범;박종춘;김상형
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.651-658
    • /
    • 2003
  • Since the first implanted in September 1997, the use of On-X prosthetic heart valve has been increasing around in the world. This study was designed to assess the feasibility, safety, and the postoperative hemodynamics with this new valve in clinical setting. Material and Method: The current study was carried out on 52 patients undergoing aortic valve replacement with this prosthesis between April 1999 to August 2002 at Chonnam National University Hospital to evaluate the surgical results. 52% of the patients were male and the average age at implant was 50$\pm$13 years. The study followed the guidelines of the AATS/STS. Preoperatively, 32(61.5%) patients were in NYHA functional class III or IV and 2 patients had previous aortic valve surgery. Concomitant cardiac surgery was performed in 71.1%. The implanted valve sizes were 19 mm in 13 patients, 21 mm in 26, 23 mm in 10 and 25 mm in 3, respectively. Mean follow-up was 16.6$\pm$10.5 months (1∼39 months). Echocardiographic assessment was performed pre- and immediate postoperatively, as well as 3, 6, 12 months after surgery, evaluating pressure loss and regression of left ventricular hypertrophy. Result: Mean cardiopulmonary bypass time was 191$\pm$94.7 minutes with an aortic cross-clamp time of 142$\pm$51.7 minutes. There was no early and late mortality, Freedom from adverse events at 1 year in the study were as follows: thromboembolism, 95.6$\pm$6%; bleeding events, 90.2$\pm$4%; paravalvular leakage 92.3$\pm$4%; and overall valve-related morbidity at 1 year was 76.6$\pm$3%. There were no cases of valve thrombosis, prosthetic valve endocarditis and structural or non-structural failure. Left ventricular function at 12 months after surgery (EF=62.7$\pm$9.8%) revealed a statistically significant improvement compared to preoperative investigation (EF=55.8$\pm$15.9%, p=0.006). Left ventricular mass index was 247.3$\pm$122.3 g/$m^2$ on preoperative echocardiographic study, but regressed to 155.5$\pm$58.2 g/$m^2$ at postoperative 1 year (p=0.002). Over the follow-up period a further decrease of peak transvalvular gradients was observed in all patients: 62.5$\pm$38.0 mmHg on preoperative assessment, 18.2$\pm$6.8 mmHg at immediate postoperative period (p < 0.0001), 7.6$\pm$5.09 mmHg (p<0.0001) at 6 month, 18.0$\pm$10.8 mmHg (p<0.0001) at 1 year. Conclusion: The On-X prosthetic heart valve performs satisfactorily in the first 1 year period. Clinical outcome by examining NYHA functional classification revealed especially good results. Effective regression of left ventricular hypertrophy and statistically significant decrease of transvalvular gradient were observed over the first year, but longer-term follow-up of this patient group is needed to establish the expected rates for late valve-related events as well as the long-term clinical efficacy of this valve.

20 Years Surgical Experiences for Ebstein's Anomaly (엡스타인 기형의 20년 수술 치험)

  • Lee, Sak;Park, Han-Ki;Lee, Chang-Young;Chang, Byung-Chul;Park, Young-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.280-287
    • /
    • 2007
  • Background: We retrospectively evaluated the clinical results of surgically managing patients with Ebstein's anomaly. Material and Method: Between Feb. f 984 and June 2006, 50 patients who underwent surgical treatment for Ebstein's anomaly at Yonsei Cardiovascular Center were retrospectively reviewed. The mean age of the patients was 26.9 years and 19 patients were male, Associated anomalies included atrial septal defect (33), patent ductus arteriosus (2), ventricular septal defect (1), and pulmonary stenosis (4), and 90%, (45/50) of the patients had more than a moderate degree of tricuspid regurgitation. Carpentier type A was present in 6 patients, type B in 26, type C in 14 and type D in 4. Ten patients were associated with WPW syndrome. Conservative surgery was possible in 31 patients (tricuspid annuloplasty, plication of the atrialized RV), Fontan's operation was peformed in 4 patients, tricuspid valve replacement was done in 12 and palliative surgery was done in 2 patients. Thirteen patients were associated with hi-directional cavopulmonary shunt (BCPS: one and a half ventricular repairs): 10 patients with WPW syndrome and 4 patients with atrial fibrillation underwent concomitant ablation. Result: The postoperative median NYHA functional class $(3{\rightarrow}1)$ and the mean cardio-thoracic ratio $(0.65{\rightarrow}0.59)$ were decreased significantly (p<0.001, p=0.014). The mean oxygen saturation $(86.6{\rightarrow}94.1%)$, and median TR grade $(4{\rightarrow}1)$ were also significantly improved (p=0.004, p<0.001). For comparison of BCPS and conservative surgery, the preoperative right ventricular pressure (33.0 vs. 41.3 mmHg), the ICU stay (2.80 vs. 1.89 days), the hospital say (10.6 vs. 16.8 days), and the left ventricular ejection fraction (64.3 vs. 72.8%) were statistically different. Postoperative mortality occurred in 3 patients (6%) due to biventricular failure in 2 patients and sepsis in the other patient. The mean follow up duration was 101.5 months, and one patient died of Fontan failure and 6 patients required reoperation (bioprosthetic degenerative change (2) and Fontan conversion (4)). The overall survival rate at 10 years was 90.2%, the freedom from reoperation rate and rate of cardiac related events were 78.9% and 49.2%, respectively. Conclusion: Surgical management of Ebstein's anomaly can be performed safely, and the associated BCPS may be helpful for high-risk patients. Adequate application of surgical management may increase the long-term survival with a reduced rate of reoperation.

Clinical Characteristics and Adherence of Patients Who Were Prescribed Home Oxygen Therapy Due to Chronic Respiratory Failure in One University Hospital: Survey after National Health Insurance Coverage (한 대학병원에서 조사된 재택산소요법을 받고 있는 환자의 특성과 재택산소요법 처방에 대한 순응도: 건강보험급여전환 후 조사)

  • Koo, Ho-Seok;Song, Young Jin;Lee, Seung Heon;Lee, Young Min;Kim, Hyun Gook;Park, I-Nae;Jung, Hoon;Choi, Sang Bong;Lee, Sung-Soon;Hur, Jin-Won;Lee, Hyuk Pyo;Yum, Ho-Kee;Choi, Soo Jeon;Lee, Hyun-Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.3
    • /
    • pp.192-197
    • /
    • 2009
  • Background: Despite the benefits of home oxygen therapy in patients suffering chronic respiratory failure, previous reports in Korea revealed lower compliance to oxygen therapy and a shorter time for oxygen use than expected. However, these papers were published before oxygen therapy was covered by the national insurance system. Therefore, this study examined whether there were some changes in compliance, using time and other clinical features of home oxygen therapy after insurance coverage. Methods: This study reviewed the medical records of patients prescribed home oxygen therapy in our hospital from November 1, 2006 to September 31, 2008. The patients were interviewed either in person or by telephone to obtain information related to oxygen therapy. Results: During study period, a total 105 patients started home oxygen therapy. The mean age was 69 and 60 (57%) were male. The mean oxygen partial pressure in the arterial blood was 54.5 mmHg and oxygen saturation was 86.3%. Primary diseases that caused hypoxemia were COPD (n=64), lung cancer (n=14), Tb destroyed lung (n=12) and others. After oxygen therapy, more than 50% of patients experienced relief of their subjective dyspnea. The mean daily use of oxygen was 9.8${\pm}$7.3 hours and oxygen was not used during activity outside of their home (mean time, 5.4${\pm}$3.7 hours). Twenty four patients (36%) stopped using oxygen voluntarily 7${\pm}$4.7 months after being prescribed oxygen and showed a less severe pulmonary and right heart function. The causes of stopping were subjective symptom relief (n=11), inconvenience (n=6) and others (7). Conclusion: The prescription of home oxygen has increased since national insurance started to cover home oxygen therapy. However, the mean time for using oxygen is still shorter than expected. During activity of outside their home, patients could not use oxygen due to the absence of portable oxygen. Overall, continuous education to change the misunderstandings about oxygen therapy, more economic support from national insurance and coverage for portable oxygen are needed to extend the oxygen use time and maintain oxygen usage.

The Clinical Application and Results of Palliative Damus-Kaye-Stansel Procedure (고식적 Damus-Kaye-Stansel 술식의 임상적 적용 및 결과)

  • Lim, Hong-Gook;Kim, Soo-Jin;Kim, Woong-Han;Hwang, Seong-Wook;Lee, Cheul;Shinn, Sung-Ho;Yie, Kil-Soo;Lee, Jae-Woong;Lee, Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • Background: The Damus-Kaye-Stansel (DKS) procedure is a proximal MPA-ascending aorta anastomosis used to relieve systemic ventricular outflow tract obstructions (SVOTO) and pulmonary hypertension. The purpose of this study was to review the indications and outcomes of the DKS procedure, including the DKS pathway and semilunar valve function. Material and Method: A retrospective review of 28 patients who underwent a DKS procedure between May 1994 and April 2006 was performed. The median age at operation was 5.3 months ($13\;days{\sim}38.1\;months$) and body weight was 5.0 kg ($2.9{\sim}13.5\;kg$). Preoperative pressure gradients were $25.3{\pm}15.7\;mmHg$ ($10{\sim}60\;mmHg$). Eighteen patients underwent a preliminary pulmonary artery banding as an initial palliation. Preoperative main diagnoses were double outlet right ventricle in 9 patients, double inlet left ventricle with ventriculoarterial discordance in 6,. another functional univentricular heart in 5, Criss-cross heart in 4, complete atrioventricular septal defect in 3, and hypoplastic left heart variant in 1. DKS techniques included end-to-side anastomosis with patch augmentation in 14 patients, classical end-to-side anastomosis in 6, Lamberti method (double-barrel) in 3, and others in 5. The bidirectional cavopulmonary shunt and Fontan procedure were concomitantly performed in 6 and 2 patients, respectively. Result: There were 4 hospital deaths (14.3%), and 3 late deaths (12.5%) with a follow-up duration of $62.7{\pm}38.9$ months ($3.3{\sim}128.1$ months). Kaplan-Meier estimated actuarial survival was $71.9%{\pm}9.3%$ at 10 years. Multivariate analysis showed right ventricle type single ventricle (hazard ratio=13.960, p=0.004) and the DKS procedure as initial operation (hazard ratio=6.767, p=0.042) as significant mortality risk factors. Four patients underwent staged biventricular repair and 13 received Fontan completion. No SVOTO was detected after the procedure by either cardiac catheterization or echocardiography except in one patient. There was no semiulnar valve regurgitation (>Gr II) or semilunar valve-related reoperation, but one patient (3.6%) who underwent classical end-to-side anastomosis needed reoperation for pulmonary artery stenosis caused by compression of the enlarged DKS pathway. The freedom from reoperation for the DKS pathway and semilunar valve was 87.5% at 10 years after operation. Conclusion: The DKS procedure can improve the management of SVOTO, and facilitate the selected patients who are high risk for biventricular repair just after birth to undergo successful staged biventricular repair. Preliminary pulmonary artery banding is a safe and effective procedure that improves the likelihood of successful DKS by decreasing pulmonary vascular resistance. The long-term outcome of the DKS procedure for semilunar valve function, DKS pathway, and relief of SVOTO is satisfactory.

Low Temperature Growth of MCN(M=Ti, Hf) Coating Layers by Plasma Enhanced MOCVD and Study on Their Characteristics (플라즈마 보조 유기금속 화학기상 증착법에 의한 MCN(M=Ti, Hf) 코팅막의 저온성장과 그들의 특성연구)

  • Boo, Jin-Hyo;Heo, Cheol-Ho;Cho, Yong-Ki;Yoon, Joo-Sun;Han, Jeon-G.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.563-575
    • /
    • 2006
  • Ti(C,N) films are synthesized by pulsed DC plasma enhanced chemical vapor deposition (PEMOCVD) using metal-organic compounds of tetrakis diethylamide titanium at $200-300^{\circ}C$. To compare plasma parameter, in this study, $H_2$ and $He/H_2$ gases are used as carrier gas. The effect of $N_2\;and\;NH_3$ gases as reactive gas is also evaluated in reduction of C content of the films. Radical formation and ionization behaviors in plasma are analyzed in-situ by optical emission spectroscopy (OES) at various pulsed bias voltages and gas species. He and $H_2$ mixture is very effective in enhancing ionization of radicals, especially for the $N_2$. Ammonia $(NH_3)$ gas also highly reduces the formation of CN radical, thereby decreasing C content of Ti(C, N) films in a great deal. The microhardness of film is obtained to be $1,250\;Hk_{0.01}\;to\;1,760\;Hk_{0.01}$ depending on gas species and bias voltage. Higher hardness can be obtained under the conditions of $H_2\;and\;N_2$ gases as well as bias voltage of 600 V. Hf(C, N) films were also obtained by pulsed DC PEMOCYB from tetrakis diethyl-amide hafnium and $N_2/He-H_2$ mixture. The depositions were carried out at temperature of below $300^{\circ}C$, total chamber pressure of 1 Torr and varying the deposition parameters. Influences of the nitrogen contents in the plasma decreased the growth rate and attributed to amorphous components, to the high carbon content of the film. In XRD analysis the domain lattice plain was (111) direction and the maximum microhardness was observed to be $2,460\;Hk_{0.025}$ for a Hf(C,N) film grown under -600 V and 0.1 flow rate of nitrogen. The optical emission spectra measured during PEMOCVD processes of Hf(C, N) film growth were also discussed. $N_2,\;N_2^+$, H, He, CH, CN radicals and metal species(Hf) were detected and CH, CN radicals that make an important role of total PEMOCVD process increased carbon content.

Occurrence and Chemical Composition of Dolomite from Komdok Pb-Zn Deposit (검덕 연-아연 광상의 돌로마이트 산상과 화학조성)

  • Yoo, Bong Chul
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.2
    • /
    • pp.107-120
    • /
    • 2021
  • The Komdok Pb-Zn deposit, which is the largest Pb-Zn deposit in Korea, is located at the Hyesan-Riwon metallogenic zone in Jiao Liao Ji belt included Paleoproterozoic Macheolryeong group. The geology of this deposit consists of Paleoproterozoic metasedimentary rocks, Jurassic Mantapsan intrusive rocks and Cenozoic basalt. The Komdok deposit which is a SEDEX type deposit occurs as layer ore and vein ore in the Paleoproterozoic metasedimentary rocks. Based on mineral petrography and paragenesis, dolomites from this deposit are classified four types (1. dolomite (D0) as hostrock, 2. early dolomite (D1) associated with tremolite, actinolite, diopside, sphalerite and galena from amphibolite facies, 3. late dolomite (D2) associated with talc, calcite, quartz, sphalerite and galena from amphibolite facies, 4. dolomite (D3) associated with white mica, chlorite, sphalerite and galena from quartz vein). The structural formulars of dolomites are determined to be Ca1.00-1.20Mg0.80-0.99Fe0.00-0.01Zn0.00-0.02(CO3)2(D0), Ca1.00-1.02M0.97-0.99Fe0.00-0.01Zn0.00-0.02(CO3)2(D1), Ca0.99-1.03Mg0.93-0.98Fe0.01-0.05Mn0.00-0.01As0.00-0.01(CO3)2(D2) and Ca0.95-1.04Mg0.59-0.68Fe0.30-0.36Mn0.00-0.01 (CO3)2(D3), respectively. It means that dolomites from Komdok deposit have higher content of trace elements (FeO, MnO, HfO2, ZnO, PbO, Sb2O5 and As2O5) compared to the theoretical composition of dolomite. These trace elements (FeO, MnO, ZnO, Sb2O5 and As2O5) show increase and decrease trend according to paragenetic sequence, but HfO2 and PbO elements no show increase and decrease trend according to paragenetic sequence. Dolomites correspond to Ferroan dolomite (D0, D1 and D2), and Ferroan dolomite and ankerite (D3), respectively. Therefore, 1) dolomite (D0) as hostrock was formed by subsequent diagenesis after sedimentation of Paleoproterozoic (2012~1700 Ma) silica-bearing dolomite in the marine evaporative environment. 2) Early dolomite (D1) was formed by hydrothermal metasomatism origined metamorphism (amphibolite facies) associated with intrusion (1890~1680 Ma) of Paleoproterozoic Riwon complex. 3) Late dolomte (D2) was formed from residual fluid by a decrease of temperature and pressure. and dolomite (D3) in quartz vein was formed by intrusion (213~181 Ma) of Jurassic Mantapsan intrusive rocks.