• Title/Summary/Keyword: 안전관리법령집

Search Result 14, Processing Time 0.025 seconds

진흥회소식

  • Korea Electronics Association
    • Journal of Korean Electronics
    • /
    • v.5 no.6
    • /
    • pp.101-102
    • /
    • 1985
  • PDF

Systematic Improvement of Safety Management-Related Laws in Domestic Demolition Works (국내 해체공사 안전관리 관련 법령의 체계적인 개선방안)

  • Ha, Gee-Joo;Ha, Jae-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.169-178
    • /
    • 2010
  • Generally speaking, the demolition works is the subsequent construction activity which has been done after building life-span of twenty two years or so. However, it was not prepared suitable systems and laws and regulations as long-term solutions. In this study, it was suggested the improvement guideline of safety management-related laws in domestic demolition works. The three improvement of laws was suggested as follows. ${\bullet}$ First, it was suggested proposals for demolition works standards in safety management plan of management law for construction activity. ${\bullet}$ Secondly, it was provided improvements for standard safety work guide of demolition works of industrial safety and health law. ${\bullet}$ Third, it was proposed integration method of redundancy in safety management plan and risk assessment regulations.

A study on the improvement plans of precision safety inspection and precision safety diagnosis in tunnel structure (터널구조물 정밀안전점검 및 정밀안전진단 개선방안 고찰)

  • Lee, Gyu-Phil;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.2
    • /
    • pp.183-192
    • /
    • 2022
  • Function and performance degradation in tunnel structure can cause road's function loss, proactive maintenance is needed to prevent the initial damage from progressing to intensified damage. Inspection and diagnosis are implemented in accordance with regulations, but it does not fully reflect maintenance processes such as inspection and diagnosis, planning rehabilitation and carrying out. It was carried out for 5,540 cases inspection and diagnosis result in 1,728 tunnels was analyzed to suggest rational maintenance plan in this study.

Pool proof safety through the old apartments redesigned to ensure safety study (노후아파트 안전관리를 통한 풀 푸르프 재설계로 안전성 확보에 관한 연구)

  • Baek, Dong Seung;Lee, Jong Hyun;Park, Sung Bong
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.280-287
    • /
    • 2018
  • Purpose: The study is based on comparative review of the actual inspection of apartments and aims at proposing easy accessible and useful safety control which is enhanced from pre-existing safety apparatus. Method: On the basis of preceding research data of apartment buildings, the study presents reported problems and real condition of apartment buildings based on Housing Related Legislation and Housing Act. Results: Safety management plans and safety inspection for buildings are needed. When conducting a safety check, traceability management system for internal/exterior facilities should be available. Most important of all, 24 hour a day of self-management system for elevators, fire protection, and security cameras is necessary. Conclusion: Through the study, there should be a process of confirming problems of building security management; such as checking the management condition through apartments' resident representatives, and seeking improvement measures.

Current Status Analyses and Efficient Strategies Subjected to Safety Management of Small-Scaled Old Buildings (소규모 노후 건축물 안전관리 실태분석 및 효율화 방안)

  • Ji-Eon Lee;Jong-Chan Kim;Sung-Ho Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.58-70
    • /
    • 2023
  • Based on the current state of safety management for small-scaled old buildings, this study identified problems and proposed improvement plans. The study investigated the current status of safety management based on relevant laws and government and financial portal data, as well as budget documents related to the targets of safety management, the organization responsible for safety management, and the budget required for organizational operation. As a result, the study revealed the problem of safety management blind spots for buildings that are not included in the legal safety inspection targets. It also identified difficulties in securing specialized personnel for the operation of local building safety centers and financial constraints for the operation of building safety special accounting. To address these issues, the study proposed measures such as expanding the scope of safety inspection targets for small-scaled old buildings to reduce safety management blind spots, improving compensation regulations for specialized personnel, setting a minimum ratio for enforcement fines to secure financial resources, and gradually adjusting building permit fees. The study aimed to contribute to improving the efficiency of safety management for small-scaled old buildings based on these proposed measures.

A Study on the Legal Application of Big Data and AI for Strengthening the Safety of Local Festivals (지역축제 안전성 강화를 위한 빅데이터와 AI의 법적 적용 방안에 관한 연구)

  • Jung Sub Park
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.3
    • /
    • pp.635-643
    • /
    • 2024
  • Purpose: This study is to seek the introduction of big data and AI technologies to strengthen the safety of local festivals, and to present legal application measures to effectively realize them. Method: diagnose the current status of the legal system related to the safety of local festivals through literature review, case analysis, and examination of legal systems, and to propose safety management measures based on big data and AI, as well as related legal improvement measures that can effectively support these initiatives. Result: Local festival safety-related laws have different purposes and regulations, and it has been confirmed that there are many difficulties for organizers to comply and apply them in an integrated manner. In particular, a clear legal basis is required for the introduction of big data and AI technologies, and it is important to establish a consistent safety management operating system through an integrated legal system. Conclusion: In order to introduce big data and AI technologies to local festivals and enhance safety, the following legal improvements are necessary: first, the establishment of an integrated legal system; second, the mandatory allocation of safety management costs; and third, the establishment and operation of an integrated control center.

Improved System for Establishing a Culture to Wear Personal Protective Gear (개인보호구 착용문화 정착을 위한 제도개선)

  • Jeung, Sueng Hyo;Lee, Yong-Soo;Kim, ChangEun
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.2 no.1
    • /
    • pp.16-20
    • /
    • 2019
  • About 50% of disasters occurring at domestic construction sites are caused by the accidents not wearing personal protective equipment. Under the current statutes, employers are required to provide personal protective equipment and workers are required to wear personal protective equipment. However, there is insufficient compliance with wearing personal protective equipment on site. This study is about the measure of improving the system to the way of purchasing, wearing and managing personal protective equipment by individual workers, and refunding the cost of personal protective equipment to workers. It is expected that this thesis will improve the system of personal protective equipment effectively, and contribute to the prevention of disasters by settling the culture of wearing personal protective equipment.

A Study on the Safety Design Rule Checking System for Automatic Verification of Design Errors (설계오류 자동 검증을 위한 안전 설계 Rule Checking 체계에 관한 연구)

  • Dukhan Kim;Yuho Yang;Youngwoo Chon
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.60-68
    • /
    • 2024
  • Purpose: When designing plants and workplaces such as handling and using chemicals, a system that can automatically determine whether the design has been made in compliance with domestic safety management laws is established to shorten the review time and increase accuracy. Method: Safety design standards for chemical handling and use workplaces were investigated, and types and systems were derived that could automatically judge design errors by dividing the articles into semantic units. Result: An automatic design review method performed when designing a building was proposed, and a system that can review the safety design requirements required when designing a chemical handling business site through the development of a rule checker was proposed. After confirming whether the law is subject to application, the safety design rules are classified into semantic units through preprocessing. The classified results can be classified into four types, and the specifications, space, conditions, situations, and specific devices and facilities to reinforce safety were analyzed as representative types. It proposes a system that prepares a diagram for the safety design rule and allows it to be reviewed through the rule checker program.

A study on establishment of measurement and analysis frequency of maintenance monitoring in tunnel (터널 유지관리계측의 측정 및 분석주기 설정 연구)

  • Woo, Jong-Tae;Lee, Kang-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.2
    • /
    • pp.117-129
    • /
    • 2012
  • In this study, research was performed to establish the measurement and frequency of analysis for maintenance monitoring by investigation of tunnel maintenance monitoring system in the tunnel which was installed in the Seoul metro line 5, 7 and 8, using that the domestic and foreign application case, results of analyzed maintenance monitoring in the domestic tunnel and legal safety management standard of the facility. The results of the monitoring management about analysis frequency to the present are considered that the problem about measuring frequency does not occur. According to the analysis results of the maintenance monitoring which are located on the 5, 6th subway line, they are analyzed that the stress of concrete lining and reinforced bar are converged gradually after 45 months. Therefore Monitoring of measurement and analysis frequency is conduct more often within about 4 years after the measuring instrument installation. Four years later, slowing the frequency of measurement is considered reasonable.

Disaster Management and Disaster Medical Improvement in Underground Space (서울시 지하공간 재난관리 및 재난의료 개선방안)

  • Bae, Yoonshin;Park, Jihye
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.2
    • /
    • pp.110-122
    • /
    • 2011
  • In this study, the disaster management and disaster medical improvement was described in underground space(specifically underground shopping center) in case of fire disaster occurred. Firstly, statue and system was discussed concerning building law, safety, fire services, refuge. The underground in Seoul management is classified as to space and form and management agent is different according to the type form. Because the difficulty of emergency rescue arises due to individual management system unified system needs to be established and improvement of facility management agent is necessary. For the patient to be transfer on the ground, corporation between command head quarter and emergency rescue team are essential. And disaster information and emergency medical information are also need to be considered. Therefore, effective countermeasures for emergency saving is urgent considering distribution of medical institution and medical treatment.