• Title/Summary/Keyword: 안면 스캔

Search Result 43, Processing Time 0.022 seconds

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

A Case of Metastatic Oral Carcinoma from Rectal Cancer (직장암 유래 전이성 구강 암종의 진단예)

  • Shin, Keum-back;Kang, Kee-hyun;Chae, Gyu-sam
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.2
    • /
    • pp.171-179
    • /
    • 1999
  • The authors experienced a oral carcinoma involving the medial cortex of the right ramus of mandible and the left side of the maxilla which was metastasized from primary rectal adenocarcinoma based on the comprehensive evaluation of data obtained from (1) the past medical history of primary rectal adenocarcinoma, (2) the computerized tomographic views of the homogeneous mass on the anteromedial region of the right ramus of mandible destructing the medial cortex of the right ramus of mandible, and the irregular mass around the clivus spreading into the sphenoid sinus and destructing the left side of the maxilla ; the bone scanning of hot spots on the nasal region and the left side of maxilla ; the posteroanterior chest radiographic view of multiple nodular radiopacities on the lung, (3) the retrospective review of the sonographic view of a hypoechoic, well-demarcated, target-like mass with central hyperechoic focus on right lobe of liver in a Korean female of 49-year-old who complained the ptosis of left eyelid, the swelling on left zygomatic area, the left facial paralysis, the facial asymmetry and a round-shaped, elevated lesion with a hematoma on the mucosa covering the right ramus of mandible.

  • PDF

CLINICAL EFFECTIVENESS OF BONE SCAN FOR DIFFERENTIAL DIAGNOSIS OF JAW LESION (악골 병소의 감별 진단시 골스캔의 임상적 유용성)

  • Kim, Jeong-Mo;Kim, Chul-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.1
    • /
    • pp.33-41
    • /
    • 2007
  • Bone scan using radioactive isotope can be more effective than conventional X-ray radiograph for finding jaw lesion because it takes an image of the physiologic change of bone. This study is designed to show how available bone scan is able to diagnose jaw lesion better than simple X-ray and CT, as well as to determine a basis of diagnosis for jaw lesion using bone scan. The 77 patients, visiting the Oral & Maxillofacial Surgery, Department of Dankook University Hospital from January 2002. to August 2005. who were diagnosed histopathologically with postoperative malignant tumor, osteomyelitis, and bone infiltrative benign disease. Preoperative X-ray, CT, bone scan were taken and were compared with histopathologic finding. Also to compare specificty of each lesion in bone scan, bone density was measured to compare. The results were as follows. 1. Among the 25 cases of oral malignant tumor of bony invasion, a positive diagnosis associated with histopathologic evaluation, 22 cases(88%) in bone scan, 14 cases(56%) in CT image, and 10 cases40%) in simple X-ray. 2. Among the 31 cases of osteomyelitis, a positive diagnosis associated with histopathologic evaluation, 30 cases(97%) in bone scan, 23 cases(74%) in CT image, and 19 cases(61%) in simple X-ray. 3. Among the 11cases of bone infiltrative benign disease, a positive diagnosis associated with histopathologic evaluation, 11 cases(100%) in bone scan, 10 cases(91%) in CT image, and 6 cases(55%) in simple X-ray. 4. Measurement of bone density in each group showed no statistical significant difference between malignant tumor and osteomyelitis as well as benign bone disease. But, a statistical significance was seen between osteomyelitis and benign bone disease. From this results, bone scan are more sensitive than simple X-ray and CT image in jaw lesion diagnosis, but specificity shows no significant difference. Therefore, it should be suggested that evaluation of bone scan must be carrying out in reference to final histopathologic diagnosis.

The Study on the Diagnostic Value of Salivary Gland Scintigraphy in Patients with Xerostomia (구강건조증 환자의 타액선 스캔의 진단학적 가치에 관한 연구)

  • Chung, Sung-Chang;Lee, Sung-Woo;Kim, Young-Ku;Kho, Hong-Seop;Yum, Kwang-Won
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.145-151
    • /
    • 2000
  • The present study was performed to investigate the relationship between the salivary flow rate and the interpretation results of salivary scan in the patients with dry mouth. Twenty-five patients with dry mouth who visited the Dept. of Oral Medicine & Oral Diagnosis, Seoul National University Dental Hospital, were included. The unstimulated whole salivary flow rate was determined by the spitting method and the stimulated whole salivary flow rate was measured with gum-base chewing. Salivary scan was performed after the infusion of $^{99m}technetium$ pertechnetate(Tc) and interpreted. The obtained results were as follows: 1. The unstimulated and stimulated whole salivary flow rate were significantly decreased compared to normal value, which reflected the extensive destruction of salivary gland function in the patients with dry mouth. 2. The unstimulated and stimulated whole salivary flow rate were decreased in the group with decreased function in salivary scan compared with the group with normal function in salivary scan. However, there was no statistical significance between groups. 3. The difference between the stimulated and unstimulated whole salivary flow rates was greater in the group with normal function in salivary scan compared with the group with decreased function in salivary scan. 4. There was significant positive correlation between the stimulated and unstimulated whole salivary flow rates. The level of correlation was higher in the group with decreased function in salivary scan than the group with normal function in salivary scan. Collectively, these data suggested that salivary scan had the limited value. The comprehensive evaluation including history taking, clinical examination, clinical laboratory as well as the measurement of salivary flow rate are need for patients with dry mouth.

  • PDF

Fabrication of complete dentures made with monolithic discs through CAD/CAM using facial scan data and individual tray duplicating temporary denture: a case report (안면스캔 데이터와 임시의치를 복제한 개인 트레이를 활용하여 CAD/CAM을 통한 monolithic disc로 제작한 총의치 수복: 증례 보고)

  • Ju Hyun Kim;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.158-167
    • /
    • 2023
  • As digital technology has advanced in the field of dentistry, the use of computer-aided design/computer-aided manufacturing (CAD/CAM) has brought changes to the stages of dental treatment. The use of CAD/CAM technology in dental restoration offers clinical efficiency and convenience by reducing production time and appointment intervals, while also simplifying the fabrication process to reduce errors. In this case, digital replication and printing of temporary teeth were used to aid a patient with complex medical histories and physical disabilities. The final impression obtained with silicone impression material included information on the vertical dimension, centric relation, and the angle and length of the anterior teeth, which shortened the production time and appointment intervals and increased patient satisfaction. The final restoration was fabricated using milling and monolithic disc techniques, demonstrating appropriate stability, retention, and support, resulting in functional and aesthetic satisfaction.

Clinical Effect of Avocado/Soybean Unsaponifiables on Osteoarthritis of the Temporomandibular Joint (측두하악관절의 골관절염 치료에서 Avocado/Soybean Unsaponifiables의 효용성)

  • Kim, Hee-Jin;Park, June-Sang;Ko, Myung-Yun;Ahn, Yong-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.2
    • /
    • pp.185-197
    • /
    • 2006
  • The aim of this study was to investigate the beneficial effect of a daily dose of 300 mg of ASU taken for more than 3 months on the subjects diagnosed as osteoarthritis of temporomandibular joint by RDC/TMD. Total 68 outpatients(15-54y) of female except menopause in Orofacial Pain Clinics of the Pusan National University Hospital were randomly assigned to either an ASU group(n=36) or a placebo group(n=32). The pain, noise and limited mouth opening(LOM) were evaluated by numerical analogue scale(NAS, range 0-10) and maximum comfortable opening(MCO) were measured by milimeter scale. The difference of simple uptake rate(SUR) on bone scan, hot spot(HS) on coronal SPECT, condylar bony changes on CT between the ASU and placebo groups were compared to investigate the objective effect. The obtained results were as follows. 1. Comparison of the NAS of pain, noise, LOM and MCO before treatment and 3, 6 and 9 months after treatment showed no significant difference between the ASU and placebo groups. 2. Comparison of the NAS of pain, noise, LOM and MCO before treatment and 3, 6 and 9 months after treatment showed no significant difference between the ASU and placebo groups without splint treatment, but showed more increased MCO in the ASU group than the placebo group with splint treatment at 6, 9 months after treatment. 3. Comparison of the NAS of pain before treatment and 3, 6 and 9 months after treatment that the NAS of pain at first visit divided into two groups(above or below 6) showed more decreased the NAS of pain in the ASU group than the placebo group that the NAS of pain at first visit was above 6. 4. Comparison of the NAS of pain, noise, LOM and MCO during 6 months period showed improvement of clinical symptoms within group, but no significant difference between subjects. 5. The simple uptake ratio(SUR) on bone scan and hot spot(HS) on coronal SPECT showed more increased SUR and HS in affected side than non-affected side of the ASU and placebo groups. 6. Comparing of condylar bony changes, osseous remodeling were observed highest, osteophyte lowest in the affected and non-affected side of the two groups. After treatment, comparison of condylar bony changes were observed more decreased erosive features in the ASU group than the placebo group.

Gene Expression Profiling of Human Salivary Gland Carcinogenesis with cDNA Microarray (인간 타액선 암발생에서 cDNA Microarray를 이용한 유전자발현 Profile연구)

  • Kim, Eun-Cheol;Shin, Min;Lee, Dong-Geun;Lee, Ju-Seok;Park, Myung-Hee
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.4
    • /
    • pp.306-323
    • /
    • 2001
  • 종양발생에서 유전자 발현을 확인하고 profile 변화를 monitor하는 것은 병리학적 변화의 원인뿐 아니라 질병탐지와 진료의 새로운 목표를 확인하기 위한 새로운 기회를 제공해준다. cDNA microarray는 수천개의 유전자 발현을 동시에 연구할 수 있는 최신의 방법으로 피부, 유방, 간을 비롯한 다른 인체장기에서는 일부 이루어졌으나 array를 이용해 타액선 종양 연구에서는 전혀 이루어지지 않았다. 인간의 타액선 세포의 악성형질전환을 조절하는 분자적 상태를 연구하기 위해 본 연구는 약 2,000개의 유전자가 print된 cDNA microarray를 이용하여 인간 타액선 도관상피세포주(HSG)와 악하선에서 기원한 미분화 선암종(SGT)간에 비교연구를 하였다. Cy3와 Cy5 dye로 각각의 세포주에서 얻은 RNA와 reciprocal hybridize시키고 GenePix 4000 scanner로 스캔하고 GenePix Pro로 분석한 후 log2로 평균발현비율을 전환시켜 최소 2배이상의 발현을 보이는 유전자를 분석대상으로 하였다. 90%이상의 유전자가 비슷한 발현을 보였으며 2배이상의 발현을 보이는 경우 HSG가 SGT에 비해 72개 유전자가, SGT가 HSG에 비해 111개의 유전자 발현이 up-regulation되어 총 10%미만의 발현차이를 보였고 반복된 hybridization 으로부터 얻은 선택된 spot의 Pearson 상관계수는 -0.85이였다. HSG에서는 6번 p 염색체에서 과발현되는 유전자가 가장 많았고, SGT에서는 11번 q 염색체에서 가장 많았는데 HSG에서는 SGT에 비해 9, 13, 17, 18, 20, 21, 22염색체에서 과발현 되는 유전자 수가 많았고, SGT에서는 HSG에 비해 2, 7, 10, 15 염색체에서 유전자 발현 증가가 관찰되었다. HSG와 SGT간의 유전 발현을 기능별로 분석한 결과 몇 가지 주요 경로가 세포악성에 관련됨을 발견하였고, 타액선 도관상피세포에서 선암종을 구별하는데 기여하는 관련된 몇종의 과다 발현된 유전자를 찾았는데 전사인자, 성장인자 및 수용기, 세포골격 및 세포외기질 단백, 세포내 신호전달조절자 및 인자, 세포표면 항원등의 그룹으로 분류할 수 있었다. 따라서 이러한 microarray를 이용한 분자학적 표지자 연구가 악성 타액선 종양 발생과정에서 큰 도움을 줄 수 있을 뿐 아니라 유전자 조절에 의한 진단, 예후, 치료에서의 정확성을 개선시킬 수 있으리라 여겨진다.

  • PDF

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

All-on-6 implant fixed prosthesis restoration with full-digital system on edentulous patient: A case report (무치악 환자에서 완전 디지털 시스템을 활용한 All-on-6 임플란트 고정성 보철물 수복 증례)

  • Lee, SeungJin;Jeong, Seung-Mi;Chung, Chae-Heon;Fang, YiQin;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.497-507
    • /
    • 2021
  • All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient's inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient's requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.