• Title/Summary/Keyword: 안면 스캔

Search Result 42, Processing Time 0.024 seconds

Digital approach integrating 3D facial scan and a virtual mockup for esthetic restorative treatment: A case report (심미보철 수복을 위한 3차원 안면스캔과 가상 보철물 시각화를 이용한 디지털 치료 증례)

  • Mai, Hai Yen;Choi, Yong-Do;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.425-431
    • /
    • 2019
  • This clinical case report describes the digital workflow that combines a face scan, cone beam computed tomography and an intraoral scan to visualize the outcome of prosthodontic treatment in the anterior region. This approach improves communication between clinic, laboratory and patients. A patient with healthy general condition came for a restorative treatment to treat post-traumatic central incisors of maxilla. A virtual patient replica was made by incorporating a face scan, cone beam computed tomography and an intraoral scan. Design mockup of definitive restorations was shown to the patient and modified according to the patient's desire. This digital workflow facilitates the fabrication of optimal esthetic restorations, and enhances the predictability of outcome of restorations.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

Influence of the angles and number of scans on the accuracy of 3D laser scanning (3 차원 레이저 스캔영상 채득 시 스캔각도와 횟수에 따른 정확도)

  • Lee, Kyung-Min;Song, Hyo-Young;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.76-86
    • /
    • 2011
  • Objective: To investigate whether the accuracy of 3D laser scanning is influenced by the angles and number of scans. Methods: Using a 3D laser scanner, 10 manikins with facial markers were scanned at 7 horizontal angles (front view and at $20^{\circ}$, $45^{\circ}$, and $60^{\circ}$ angles on the right and left sides). Three-dimensional facial images were reconstructed by 6 methods differing in the number and angles of scans, and measurements of these images were compared to the physical measurements from the manikins. Results: The laser scan images were magnified by 0.14 - 0.26%. For images reconstructed by merging 2 scans, excluding the front view; and by merging 3 scans, including the front view and scans obtained at $20^{\circ}$ on both sides; several measurements were significantly different than the physical measurements. However, for images reconstructed by merging 3 scans, including the front view; and 5 scans, including the front view and scans obtained at $20^{\circ}$ and $60^{\circ}$ on both sides; only 1 measurement was significantly different. Conclusions: These results suggest that the number and angle of scans influence the accuracy of 3D laser scanning. A minimum of 3 scans, including the front view and scans obtained at more than $45^{\circ}$ on both sides, should be integrated to obtain accurate 3D facial images.

Using dental virtual patients with dynamic occlusion in esthetic restoration of anterior teeth: case reports (동적 교합을 나타내는 가상 환자의 형성을 통한 심미적인 전치부 보철 수복 증례)

  • Phil-Joon Koo;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.328-343
    • /
    • 2023
  • Recently, a method of fabricating an esthetic anterior fixed prosthesis by integrating data such as three-dimensional facial scan and jaw motion to form a virtual patient with dynamic occlusion has been introduced. This enables smooth communication with patients during the diagnosis process, improves the predictability of esthetic prosthetic treatment, and lowers the possibility of occlusal adjustment. In this case report, a virtual patient with dynamic occlusion was created in which the results of the treatment were simulated, and esthetic maxillary anterior fixed prosthesis was fabricated. With the aid of the virtual patient, the final restorations were satisfactory both in terms of esthetic and function.

3-step digital complete denture restoration using facialscan: a case report (안면 스캔을 이용한 3회 내원 디지털 총의치 수복: 증례보고)

  • Yeongseok Kwon;Seoung-Jin Hong;Janghyun Paek;Ahran Pae;Hyeong-Seob Kim;Kung-Rock Kwon;Kwantae Noh
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.356-366
    • /
    • 2023
  • Support, retention, and stability of dentures are key factors in the use of complete dentures in edentulous patients. With the development of digital dentistry, attempts are being made to replace traditional treatment methods. Also, struggle to reduce the number of patient visits and to manufacture high-quality digitally fabricated dentures are ongoing. In this case, a digital denture was restored using a tray capable of obtaining centric relation through gothic arch tracing and a facial scan. By replacing the traditional complete denture restoration method, the number of patient visits was reduced and esthetic results with satisfactory denture support, retention, and stability were obtained.

Aesthetic restoration n patients with unaesthetic maxillary anterior teeth using double scan : A case report (비심미적인 상악 전치부 환자에서 이중 스캔을 이용한 심미보철 수복 증례)

  • Ko, Chang Woo;Kim, Min-Ji;Yang, Hong-So;Park, Sang-Won;Park, Chan;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.166-172
    • /
    • 2018
  • In case of the treatment of maxillary anterior teeth, it should be taken into account the proper morphology, arrangement and color satisfying patient's esthetic demands. For this purpose, facial composition, dentofacial composition, dental composition and dentogingival composition should be considered making diagnosis and treatment plan in an esthetic point of view. In adjustable temporary crown state, careful evaluation and correction of the esthetic and functional aspect were performed, and the definite restoration was reproduced using double scan.

Quantification of Salivary Gland Scan Image and its Correlation with Salivary Flow Rate (타액선 스캔의 정량적 분석과 타액분비율과의 상관관계에 관한 연구)

  • Kim, Sung-Hun;Kim, Youn-Joong;Chung, Sung-Chang
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.3
    • /
    • pp.215-224
    • /
    • 2001
  • 서울대학교 치과병원 구강진단과에 구강건조증을 주소로 내원한 환자중 비자극 전타액 분비율이 0.2ml/min이하인 환자 40명과 구강건조증의 증상 및 징후가 없고 정상 타액분비율을 보이는 10명을 대상으로 비자극 전타액 분비율을 측정하고 타액선 스캔 검사를 실시하여 주타액선의 스캔 영상을 정량화한 후 이의 상관관계를 조사한 결과 다음과 같은 결론을 얻었다. 1. 구강건조증 환자군 및 정상 대조군에서 타액선 스캔 영상의 정량적 분석시 이하선 및 악하선 모두에서 좌우측 사이의 유의성 있는 차이가 없었다. 2. 타액선 스캔 영상의 정량적 분석시 구강건조증 환자군은 대조군에 비하여 악하선, 이하선 및 악하선의 합, 양측 악하선 합에서 유의한 차이를 보였다. 3. 대조군에서 타액선 스캔 영상의 정량적 수치와 비자극 전타액 분비율과는 유의성 있는 상관관계가 관찰되지 않았으나, 구강건조증 환자군에서는 유의성 있는 상관관계가 관찰되었다. 4. 구강건조증 환자군을 비자극성 전타액 분비율에 따라 세분하였을 때, 비자극 전타액 분비의 감소가 극심하여 그 측정이 불가능하였던 군은 대조군 및 나머지 구강건조증 환자군에 비하여 타액선 스캔 영상의 정량적 수치에서 유의한 차이를 보였다.

  • PDF

A Clinical Report on the Effect of CRS Usage in Degenerative Temporomanibular Joint Disease with Anterior Open Bite Applying Bone Scan (전치부 개교합을 보이는 퇴행성 관절질환에서 골스캔을 이용한 중심위교합장치의 효과 평가에 대한 임상례)

  • 박상배;김병국
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.3
    • /
    • pp.289-294
    • /
    • 1998
  • 본 증례는 측두하악관절의 퇘행성 변화를 보이는 환자에서 악교정 수술의 시행 전에 중심위교합장치를 통해 측두하악관절의 안정화를 유도하고, 또한 골스캔을 이용하여 장치의 치료효과를 평가한 임상증례이다. 환자는 24세의 여성으로 5년 전부터 전치부 개교합이 발생되기 시작하였고, 고형식 저작시 좌측 전이부에 간헐적인 통증이 발생한다는 주소로 본원에 내원하였다. 임상검사상 촉진시 양측 관절낭 후방부에 압통을 호소하였으며, 각각 50, 45mm의 최대개구량 및 최대무통성 개구량을 보였다. 좌측 악관절부에서 단순 관절 잡음, 우측 악관절부에서 염발음이 청취되었으며, 저항검사 및 부하 검사에서는 특기할 반응을 보이지 않았다. 약 7mm의 전치부 개교합의 소견을 보였으며, 파노라마 사진과 횡두개 방사선 사진 소견상 양측 과두의 크기 및 하악지의 높이가 다소 작은 소견이 관찰되었고 자기공명영상 소견상 양측성 비정복성 관절원판의 전방전위가 관찰되었다. 1997년 10월 27일 첫 번째 골스캔 소견상 양측성 비정복성 관절원판의 전방위가 관찰되엇다. 골스캔의 전방 사진에서 Densitometer를 이용하여 좌, 우측 과두부위와 상악 골부위의 가장 어두운 부분의 흑화도를 측정하였다. 각각 3회씩 구하여 평균을 구하고 좌, 우측 과두 대 상악골의 흑화도의 비율을 계산하였다. 첫번째 골스캔의 평균 흑화도는 우측 과두, 좌측과두, 상악골이 각각 0.88, 0.81, 1.32 였다. 1997년 11월 4일 중심위교합장치를 장착하였고 지속적인 물리치료를 시행하였다. 1997년 12월 10일 두 번째 골 스캔을 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.33, 0.37, 088 이었다. 1998년 1월 30일 세 번째 골스캔 소견상 두 번째 골스캔과 비교하여 활성도가 감소된 소견을 보였다. 임상검사시 무통이었다. 1998년 2월 25일 술 전 교정 위해 중심위교합장치의 장작을 중지시켰다. 1998년 6월 5일 네 번째 골스캔 소견상 이전 검사들과 비교시 흡수가 감소된 소견을 보였다. 네 번째 골스캔의 평균 흑화도는 우측 과두, 좌측 과두, 상악골이 각각 0.24, 0.19, 0.85 였다. 현재 지속적인 관찰 중이며 본원 교정과에서 악교정수술 위한 술 전 교장을 시행중이다. 결국 첫 번째 골스캔의 과두 대 상악골의 평균 흑화도의 비율은 우측과 좌측이 각각 0.66, 0.61이었고 두 번째 골스캔에서는 우측과 좌측이 각각 0.37, 0.42였고, 네번째 골스캔에서는 우측과 좌측이 각각 0.28, 0.23 이었다. 각 골스캔의 과두 대 상악골의 평균 흑화도의 비율 사이에 유의한 차이가 있는지 검증하기 위해 Standard t-test 와 ANOVA를 시행하였다. 이상의 결과에서 첫 번째, 두 번째, 네 번째 골스캔으로 갈수록 좌, 우측 과두 대 상악골의 흑화도의 비율이 유의하게 감소했음을 알 수 있었다. 결론적으로 본 증례에서는 전치부 개교합이 발생되어 악교정수술이 필요한 환자에게 측두하악관절의 안정화를 위해 중심위교합장치를 사용함으로써 퇴행성 관절질환의 진행을 억제시킬 수 있고, 퇴행성 관절질환의 활성도에 대한 평가시 골스캔이 유용할 수 있음을 보여주었다고 사료된다.

  • PDF

The assessment of dentoalveolar compensation in facial asymmetry individuals: integration of cone beam CT and laser scanned dental cast images (Cone beam CT 영상과 석고모형 레이저 스캔 영상의 결합을 이용한 안면비대칭자의 치성보상 평가)

  • Song, Hyo-Kyung;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.373-382
    • /
    • 2010
  • Objective: The purpose of this study was to assess the dentoalveolar compensation in facial asymmetry individuals using an integration of a CBCT image and a laser scanned dental cast image. Methods: The subjects consisted of 30 adults with asymmetric mandibles and 20 adults with symmetric mandibles. The CBCT and laser scanned dental cast images were integrated with a registration technique. Canine and first molar position and angulation were assessed from reference coordinates. The differences between deviated and non-deviated sides were analyzed with the paired t-test. The differences shown according to menton deviation were also statistically analyzed using Pearson correlation analysis. Results: The experimental group showed deviated and non-deviated side differences (dev.-ndev.) in the position and angle of the canine and first molars. Menton deviation showed positive correlation with the deviation side (dev.-ndev.) for the maxillary and mandibular 1st molar angles, negative correlation with the deviation side for the vertical position of the maxillary 1st molars, transverse position of the mandibular canine, transverse position and vertical position of the mesio-lingual cusp of the mandibular 1st molars. Conclusions: The upper and lower canine and first molars of facial asymmetry individuals were compensated, so the transverse position, vertical position, and angle showed differences between the deviated/non-deviated sides.

Creation of the dental virtual patients with dynamic occlusion and its application in esthetic dentistry (심미치의학 영역에서 동적 교합을 나타내는 가상 환자의 형성을 통한 전치부 보철 수복 증례)

  • An, Se-Jun;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.222-230
    • /
    • 2022
  • Digital technology is gradually expanding its field and has a great influence on various fields of dentistry. Recently in digital dentistry, the importance of superimposing various 3-dimensional (3D) image data is emerging, in order to utilize gathered data effectively for diagnosis and prosthesis fabrication. Integrating data from facial scans, intraoral scans, and mandibular movement recordings can create a virtual patient. A virtual patient is formed by integrating digital 3D diagnostic data such as intraoral and extraoral soft tissues, residual dentition, and dynamic occlusion, and the results of prosthetic treatment can be evaluated virtually. The patients in this case report were a 37-year-old female whose chief complaint is that the appearance of the existing prosthesis was distorted and a 55-year-old female patient whose anterior prosthesis needed to be refabricated after the endodontic treatment. 3D facial scans were obtained from each patient, and the patient's mandibular movements were recorded using ARCUS Digma 2 (KaVo Dental GmbH, Biberach an der Riss, Germany). The collected data were integrated on computer-aided design (CAD) software (Exocad dental CAD; exocad GmbH, Darmstadt, Germany) and transferred to a virtual articulator to create a digital virtual patient. The temporary fixed prostheses were designed, restored, and evaluated, and it was reflected into the final restorations. With the aid of the virtual dental patient, accuracy and predictability could be increased throughout treatment, simplifying the occlusal adjustment and clinical evaluation with improved esthetic outcomes.