• Title/Summary/Keyword: 안내덕트

Search Result 12, Processing Time 0.027 seconds

Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct (안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석)

  • Yoo, Geun-Jong;Choi, Hoon-Ki;Choi, Kee-Lim
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.923-932
    • /
    • 2011
  • Because of the instability of a flow pattern in the inlet transition square duct (hereinafter referred to as "transition duct") of a heat recovery steam generator (hereinafter referred to as "HRSG") in a combined cycle power plant, the Reynolds number in the first row of a tube bank is differs sharply from that in the sectional area of the transition duct. This causes differences in the heat flux in each tube in the tube bank. The computational fluid dynamics (CFD) predictions provide three-dimensional results for velocity, temperature, and other flow parameters over the entire domain of the duct and HRSG. A renormalization group theory (RNG) based k-${\epsilon}$�� turbulent model is used for obtaining the results cited in this study. A porous media option is used for modeling the tube banks and the number of transfer units method is used for determining the heat transfer characteristics. This study describes a comparison between the numerical simulation results and actual design output.

Numerical Simulation of Turbulent Flows in Inlet Duct of Heat Recovery Steam Generator (배열회수 안내덕트 내부의 난류유동 수치시뮬레이션)

  • Kwag, Seung-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.809-813
    • /
    • 2011
  • Turbulent flows are numerically simulated in the three dimensional inlet duct for heat recovery steam generator. The present study is aimed to analyze the effect of a variation in turbulent flow pattern by the change of roof angle in the transition duct. The finite volume based Navier-Stokes equations with unstructured grids are solved to make clear the flow dynamic phenomena. Reviews are made on with the data of path lines, velocity vectors, dynamic pressure, residuals for numerical convergence and so on. The k-epsilon, k-omega, Reynolds stress and RNG k-epsilon are used for generation of turbulence. Two types of roof angle are applied with and without the swirl in the duct. Turbulent flow patterns could be investigated for the optimum duct design based on the computational results.

A Numerical Study of the Turbulent Flow Characteristics in the Inlet Transition Square Duct Based on Roof Configuration (4각 안내덕트 루프형상에 의한 난류특성변화 수치해석)

  • Yoo, Geun-Jong;Choi, Hoon-Ki;Choi, Kee-Lim;Shin, Byeong-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.541-551
    • /
    • 2009
  • Configuration of the inlet transition square duct (hereinafter referred to as "transition duct") for heat recovery steam generator (hereinafter referred to as "HRSG") in combined cycle power plant is limited by the construction type of HRSG and plant site condition. The main purpose of the present study is to analyze the effect of a variation in turbulent flow pattern by roof slop angle change of transition duct for horizontal HRSG, which is influencing heat flux in heat transfer structure to the finned tube bank. In this study, a computational fluid dynamics(CFD) is applied to predict turbulent flow pattern and comparisons are made to 1/12th scale cold model test data for verification. Re-normalization group theory (RNG) based k-$\epsilon$ turbulent model, which improves the accuracy for rapidly strained flow and swirling flow in comparison with standard k-$\epsilon$ model, is used for the results cited in this study. To reduce the amount of computer resources required for modeling the finned tube bank, a porous media model is used.

Effects of an Inlet Guide Vane on the Flowrate Distribution Characteristics of the Nozzle Exit in a Defrost Duct System (성에제거 덕트 입구 가이드베인 형상이 노즐출구 유량분포특성에 미치는 영향)

  • Kim, Duck-Jin;Lee, Jee-Keun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.88-96
    • /
    • 2008
  • Effects of the duct inlet guide vane on the flowrate distribution characteristics of the defroster nozzle exit in a defrost duct system were investigated experimentally to design the optimum heating, ventilation and air conditioning (HVAC) system applied in an automotive compartment. A 3-dimensional hot-wire anemometer system was used to measure the velocity field in the vicinity of the defroster nozzle jet flow and the velocity distributions near the windshield interior surface. At first, two cases of with- and without-duct inlet guide vanes were considered as the test condition, and then three cases of the duct inlet guide vane were tested to determine the optimum guide vane shape and their positions. The arrangement of the duct inlet guide vanes has an effect on the improved flowrate distribution at the defroster nozzle exit and near the windshield interior surface. However, the application of the lots of guide vane to control the flow direction leads to increase the flow resistance, resulting in the decreased flowrate issuing from the defroster nozzle. The shape of the duct inlet guide vane affects not only the flowrate distribution between the driver side and the assistant driver side but also the reduction of the flow resistance in the defrost duct system.

NUMERICAL STUDY ON FLOW CHARACTERISTIC IN THE HEAT RECOVERY STEAM GENERATOR (배열회수장치의 유동특성에 관한 수치적 연구)

  • Choi, H.K.;Yoo, G.J.;Shin, B.J.;Kim, C.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2010
  • Performance improvements of the heat recovery steam generator(HRSG) can be achieved by improving the flow distribution of exhaust gases for a various type of different equipments. A number of design parameters are systematically investigated and their effects on an index of velocity deviation established. The parameters include the three shape of the transition duct and the wide range of the guide vane angles. The numerical results clearly reveal feature of the flow pattern in the transition duct, velocity deviation and pressure drop at tube bank part.

Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas (습식 배연탈황 시스템의 효율 향상을 위한 전산해석)

  • Hwang, Woo-Hyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.161-171
    • /
    • 2014
  • In this paper the flow dynamics of the flue gas equipment in the desulfurization system was numerically analyzed by simulating the problems for the turbulent and combustion flow from Induced Draft Fan(I.D.Fan) outlet to Booster Up Fan(B.U.Fan) inlet using the commercial CFD software of CFD-ACE+ in CFDRC company for Computational Fluid Dynamic Analysis. The guide vane of this section was examined for the minimum pressure loss and the uniform flow dynamic to B.U.Fan with the proper velocity from I.D,Fan exit to B,U,Fan inlet section at the boiler both the maximum continuous rating and the design base. The guide vanes at I,D.Fan outlet and B.U.Fan inlet were removed and modified by numerical simulation of the CFD analysis. The flue gas at the system had the less pressure loss and the uniform flow dynamics of the flow velocity and flow line by comparing with the old design equipment.

노임단가 - 2011년 하반기 적용 건설업 노임단가

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.255
    • /
    • pp.59-61
    • /
    • 2011
  • 2011년 하반기 건설업 노임단가 발표됐다. 대한건설협회가 지난 8월30일 공표한 '2011년 하반기 적용 건설업 임금실태 조사 보고서'에 따르면 하반기 적용 건설업 전체 직종 평균임금이 하루 12만9,029원으로 상반기(12만4,746원) 대비 3.43% 상승한 것으로 나타났다. 기계설비분야의 노임은 배관공과 덕트공이 9만4,293원과 9만70원으로 지난해 상반기 대비 1.4% 및 3.2%로 각각 상승했고 플랜트배관공과 플랜트용접공이 15만5,151원과 16만4,848원으로 4.6% 및 3.1%로 각각 올랐다. 이번 건설임금은 전국 2,000여개 건설현장을 대상으로 전체 117개 건설직종 종사자들에게 실제 지급된 임금을 조사해 통계분석한 것으로, 지난 9월 1일부터 건설공사 원가계산에 반영되기 시작했다. 직종별 건설업 임금은 대한설비건설협회 홈페이지(www.kmcca.or.kr)${\rightarrow}$공개자료실${\rightarrow}$(2011년 하반기 적용 건설업임금실태조사 공표)안내에서 다운로드 받을 수 있다.

  • PDF

노임단가 - 2012년 하반기 적용 건설업 노임단가

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.267
    • /
    • pp.61-64
    • /
    • 2012
  • 2012년 하반기 건설업 노임단가가 발표됐다. 대한건설협회가 지난 9월 1일 공표한 '2012년 하반기 적용 건설업 임금실태 조사 보고서'에 따르면 하반기 적용 건설업 전체 직종 평균임금이 하루 13만 8,571원으로 지난 상반기(13만2,576원) 대비 4.52% 상승한 것으로 나타났다. 기계설비분야의 노임은 배관공과 덕트공이 10만3,242원과 9만6,913원으로 지난해 상반기 대비 8.46% 및 9.38%로 각각 상승했고 플랜트특수용접공과 플랜트기계설치공이 18만2,554원과 16만2,361원으로 3.68% 및 6.45%로 각각 올랐다. 이번 건설임금은 전국 2,000여개 건설현장을 대상으로 전체 117개 건설직종 종사자들에게 실제 지급된임금을 조사해 통계 분석 한 것으로, 지난 9월 1일부터 건설공사 원가계산에 반영되기 시작했다. 직종별 건설업 임금은 대한설비건설협회 홈페이지(www.kmcca.or.kr) ${\rightarrow}$ 공개자료실 ${\rightarrow}$ 〈2012년 하반기 적용 건설업임금실태조사 공표〉 안내에서 다운로드 받을 수 있다.

  • PDF

노임단가 - 2014년 하반기 적용 건설업 노임단가

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.290
    • /
    • pp.60-63
    • /
    • 2014
  • 2014년 하반기 건설업 노임단가가 발표됐다. 대한건설협회가 지난 9월 1일 공표한 '2014년 하반기 적용 건설업 임금실태 조사 보고서'에 따르면 하반기 적용 건설업 전체 직종 평균임금이 하루 155,796원으로 지난 상반기(150,664원) 대비 0.03% 상승한 것으로 나타났다. 건축설비 공사부문 노임은 기계설비공과 덕트공이 각각 112,867원과 105,056원으로 지난 상반기 대비 5.7%와 4.4% 상승했으며, 플랜트 공사부문 노임은 플랜트보온공과 플랜트특수용접공이 각각 188,572원과 216,240원으로 지난 상반기 대비 9.9%와 7.8% 상승했다. 전반적으로 상반기 대비 건축설비 공사부문은 평균 3.4% 상승했으며, 플랜트 공사부문은 평균 5.6% 상승했다. 건설임금은 전국 2,000여개 건설현장을 대상으로 전체 117개 건설직종 종사자들에게 실제 지급된 임금을 조사해 통계분석 한 것으로, 올해 9월1일부터 건설공사 원가계산에 반영되기 시작했다. 직종별 건설업 임금은 대한설비건설협회 홈페이지(www.kmcca.or.kr) ${\rightarrow}$ 공개자료실 ${\rightarrow}$ <2014년 하반기 적용 건설업임금실태조사 공표>안내에서 다운로드 받을 수 있다.

  • PDF

Numerical Study for the Optimal Operation of Semi Dry Reactor(SDR) (SDR 반응의 운전 최적화를 위한 전산 해석)

  • Park, Ki-Woo;Jung, Yu-Jin;Jeong, Moon-Heon;Hong, Sung-Gil;Jung, Jong-Hyeon;Lim, Ki-Hyuk;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.426-430
    • /
    • 2012
  • 본 연구에서는 3차원 수치 해석 기법으로 SDR 반응기 내 유동 특성을 모사하여 유동 분포 및 체류 시간등을 확인하고 혼합 특성 개선을 위한 방법에 대해 연구하였다. 본 연구 대상 SDR 반응기는 입구 덕트와 반응기 본체의 접속 구간에 가이드 베인(Guide vane)이 설치되어 있고 그 바로 하부 지점에 흡수제를 분무하는 노즐이 설치되어 있다. 이는 처리가스가 반응기로 유입될 때 가이드 베인에 의해 선회류를 형성하여 분무된 흡수제와의 혼합을 촉진시키기 위한 목적으로 설치하였다. 시간당 1,971$m^3/min$ at $260^{\circ}C$의 처리가스가 반응기 상부로 유입되어 가이드 베인을 거쳐 선회류를 형성한 후흡수제와 혼합되어 하부로 배출되는 구조이다. 유동 특성을 분석한 결과, 처리가스가 반응기 중앙으로 강하게 편중되고 있었으며 반응기 양 측면으로 부상 기류가 형성되고 있음을 확인할 수 있다. 또한 강한 편류에 의해 체류시간도 매우 짧은 것으로 판단되는 바, 가이드 베인의 기류 안내 각도가 적합하지 못함을 확인할 수 있었다. 이는 곧 혼합 특성 저하에 따른 미반응 액적의 다량 발생과 함께 고착에 의한 스케일 형성 가능성이 매우 클 것으로 예상되므로 혼합 특성을 개선할 수 있는 설계 변경이 필요할 것으로 판단되었다. 따라서 편류를 해소하고 노즐 근처에서의 체공시간을 확보할 수 있도록 가이드 베인의 안내 각도를 더 크게 변경한 결과, 기존 설계상에서 본체 중앙에 형성되는 편류가 해소되고 선회류의 전개 각도가 커지면서 체류시간 역시 약 5초 이상으로 유지되고 있음을 확인할 수 있었다. 따라서 가이드 베인의 각도만 변경하더라도 본체 형상의 추가적인 변경없이 유동의 혼합 특성을 개선시킬 수 있을 것으로 판단되었다.

  • PDF