• Title/Summary/Keyword: 안경 렌즈

Search Result 229, Processing Time 0.019 seconds

Analysis of Replacement Cycle by Eyeglasses Scratches in Daily Life (일상생활 속 안경렌즈 흠집에 의한 교체주기 분석)

  • Jung, Mi-A;Lee, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.447-451
    • /
    • 2019
  • This study were to investigate the scratches and replacement cycles of eyeglasses according to personal characteristics in daily life. The subjects were 58 people who voluntarily participated in this study. The replacement cycle of eyeglasses according to the contact of eyelashes with eyeglasses, type and the number of eyeglasses wiped on a day were analyzed. The statistical analysis were performed by X2 test and Fisher's exact test. The average replacement cycle of the eyeglasses were longer females than males. The eyeglasses replacement cycle were significantly shorter when the eyelashes contacted the eyeglasses and when the eyeglasses were wiped using a tissue or clothes other than the eyeglasses towel. The coating film of the eyeglasses may be damaged by the convergence effect such as eyelashes or minor carelessness in daily life, and this study will continue to follow up on this result.

Development of Spectacles with Injection Molding (사출성형에 의한 안경 개발)

  • 한두희;김복현
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.298-299
    • /
    • 2001
  • 안경렌즈는 유리를 연마하여 제작하거나 단량체를 세라믹 금형에 넣어 캐스팅공법으로 플라스틱 렌즈를 만드는 것이 일반적인 방법이었다. 한편 사출성형에 의한 렌즈 및 안경의 제작은 광학적으로 우수한 재료 및 금형을 개발하지 못하여 국내에서는 시도조차 못하는 형편이다. 구미나 유럽의 일부 국가는 PMMA 및 PC를 이용하여 안경 및 안경렌즈를 개발하고 있으며, 이는 공정을 대폭 줄이기 때문에 대량 생산 및 원가 절감을 이룩할 수 있다. 본 연구에서는 PMMA 및 PC를 이용하여 그동안 성형할 때에 가장 문제가 되었던 오목 렌즈를 제작하기 위한 근본적인 금형 설계의 문제점 해결과 이를 이용한 일체형 안경과 고강도 렌즈의 제작을 고찰하였다.

A Study on the Colors of tenses I (안경렌즈 착색에 관한 연구 I)

  • 한두희
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.11a
    • /
    • pp.159-160
    • /
    • 2001
  • 안경은 현대인이 가장 많이 사용하는 편의 기구이며 건강기구이다. 한편 소비자의 개성이 다양화되면서 안경의 전체적 형태와 함께 안경테 및 안경 렌즈의 색상이 안경의 새로운 품질로 떠오르게 되었다. 본 논문에서는 잠김 및 캐스팅법에 의한 렌즈 색상내기에 대하여 자료를 제시한다.

Development of the optical cases which have many functions by injection molding. (사출성형에 의한 다기능 안경집 개발)

  • 한두희
    • Proceedings of the KAIS Fall Conference
    • /
    • 2000.10a
    • /
    • pp.226-229
    • /
    • 2000
  • 일반적으로 안경집은 일회적으로 사용하고 버리는 것이라 생각하는 사람이 많다. 안경집을 주로 생산하고 있는 대동사출금형과의 공동 노력으로 다기능성 안경집을 개발한 것을 소개한다. 일상적인 고정관념을 버리면 편리하고 기능성이 높은 제품을 만들 수 있다는 신념으로 개발한 결과 어린이나 젊은이들이 졸아할 문방구 겸용 안경집을 개발할 수 있었다. 완구는 소비자가 일상적으로 많이 접촉하기 때문에 곰팡이나 세균이 서식하지 않도록 항균 세라믹을 이용하여 항균처리하였다. 또한 상온에서 인체에 이로운 원적외선이 방출될 수 있도록 고안하였다. 단순한 색상의 무료함을 줄이기 위하여 어린이나 젊은이들이 좋아하는 상용화된 캐릭터를 사용하여 제품의 다양화를 꾀하였고, 4개의 조각으로 만들어 어린이들이나 젊은이들이 조립할 수 있도록 하여 흥미를 더할 수 있도록 하였다. 또한 소비자들이 선호하는 색을 알아보기 위하여 기존의 안경집을 활용하여 색상성호도 조사를 실시하였다. 젊은층은 자극적이고 화려한 색깔을 선호하는 한편 기성세대는 무난한 색깔을 선호하였다. 또한 콘택트 렌즈를 착용하는 경우에도 안경을 사용하는 경우가 많다. 이 경우 콘택트 렌즈와 안경을 따로 가지고 다녀야 하는 불편이 있다. 이에 착안하여 안경과 콘택트 렌즈를 겸용으로 사용하는 소비자를 위하여 안경과 콘택트 렌즈를 동시에 담을 수 있는 안경집을 개발(실용신안 출원번호:8928)하였다. 이 고안은 콘택트 렌즈를 안경집에 보관하기 위한 것으로 콘택트렌즈가 식염수에 잠겨 보관된 렌즈캡을 안경집내에 별도로 삽입되는 케이스에 수납하도록 구성하여 안경과 함께 콘택트 렌즈를 보관해 휴대하는 안경집 보관용 콘택트 렌즈 케이스에 관한 것으로 이것의 특징은 뚜껑이 열리고 닫히도록 구성된 안경집에 있어서 뚜껑 안쪽에 거울이 마련되고 뚜껑이 연결되는 선단부 안쪽에 끼움홈과 체결홈이 형성된 체결부를 갖는 안경집과 이것에 결합되는 체결구가 마련되어 개폐되는 커버가 형성된 케이스로 구성된다.로 금형설계 및 제작기간을 단축하고자 한다.ere demonstrated in rats after i.c.v., intraperitoneally and orally administration, respectively. The antiepileptical effects by the combination of compounds from ginseng; were compared with the iuluence of Rg1, Rb1, Rc and with the well known antiepileptical drugs such as carbamazepine, valproic acid. The base for the research is obtained by using the WAG/Rij strain (Luijtelaar, Coenen, Kuznetcova), an excellent genetic model for human generalized absence epilepsy. The improving action of gensinosides was effectively demonstrated on the model of electrical kindling of amygdala of WAG/Rij rats with genetically determined absences, and the influences of ginsenosides on the slow wave discharges have also been being investigated. The different characteristics of a kindling process exerted in the sex-different region of the amygdala and demonstrated that the level of sex steroids and content of neurosteroids in amygdaloid tissue ca

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

A Comparative Study on Test Methods for Ophthalmic Lens Coatings (안경렌즈 코팅의 평가 방법에 관한 비교 연구)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Ha, Jin-Wook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • We have surveyed test methods for ophthalmic lens coatings and compared the coating quality of lenses supplied by manufactures. Plastic ophthalmic lenses are produced in increasingly larger volumes. However, their softness have need resistant coatings absolutely essential in most cases. Coating lenses are typically evaluated in physical and chemical properties through random selection from produced lenses. No international standard test methods for ophthalmic lenses exist for issues such as adhesion, abrasion resistance, hardness, chemical and hot water resistance with exception of transmittance. We have learned that there is a great deal of confusion regarding the methods employed in the various tests for ophthalmic coating lenses. For this reason, test methods for ophthalmic lens coatings are needed making all of international or domestic standards available.

  • PDF

Synthesis of Ultra High Refractive Index Monomer for Plastic Optical Lens and Its Ophthalmic Lens Preparation (플라스틱 안경렌즈용 초고굴절 모노머 합성 및 이를 이용한 안경렌즈 제조)

  • Jang, Dong Gyu;Kim, Jong Hyo;Lee, Soo Min;Roh, Soo Gyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.1-6
    • /
    • 2008
  • Purpose: Plastic optical monomer materials having ultra high refractive index have an income of the whole quantity from advanced nations to domestic companies which are related to plastic optical lens. It is necessary to develop novel plastic optical lens materials in order to overcome a FTA provision and revitalize a stagnating optical lens industry in the interior optical lens industries. The new plastic optical lens materials against the substitution effect of income should be gradually demanded. This work will be synthesized novel super high refractive monomer resin materials of urethane lens series and studied the properties of optical lens using it. Methods: ETS-4 (2-(2-mercaptoethylthio)-3-{2-[3-mercapto-2-(2-mercaptoethylthio)propyl thio]ethylthio}propane -1-thiol), which is optical lens monomer resin having super high refractive index, was synthesized and identified its structure and property by elemental analysis, EI-MS, TGA, FT-IR spectroscopy, $^1H$ and $^{13}C$ NMR spectroscopies. After mixing evenly from mixed monomer resin and diisocyanate series, it was casting in glass mold. After thermal curing, the obtained optical lenses were measured and compared with the refractive index and Abbe number for studies of their optical properties. Results: We have synthesized the novel ultra high refractive index monomer resin, ETS-4, and have identified its structure and property by elemental analysis, EI-MS, TGA, FT-IR spectroscopy, $^1H$ and $^{13}C$ NMR spectroscopies. The existence of three isomers for EST-4 was identified by $^{13}C$ NMR spectroscopy. The refractive index ($N_d$ at $25^{\circ}C$) of monomer resin in liquid state obtained from the Abbe refractometer was 1.647. The refractive indexes of raw plastic optical lenses prepared from the mixed ETS-4 monomer and diisocyanate series were in the range of 1.656~1.680. Conclusions: Novel super high refractive index plastic optical lens monomer was synthesized and analysed, the optical lenses prepared using it were colorless transparency and excellent properties. It is of utility for the industrialization.

  • PDF

The Effect of Physical and Chemical Stimuli on Ophthalmic Lens Coatings (물리적, 화학적 자극이 안경 렌즈의 코팅에 미치는 영향)

  • Kim, So Ra;Kim, Ji Yoon;Kim, Ka Young;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.237-245
    • /
    • 2011
  • Purpose: The present study was conducted to investigate whether certain repeated physical and/or chemical stimuli added on ophthalmic lenses might induce any changes of the functions of lens coatings. Methods: The changes in lens surface, light transmittance, foggy duration, durability of ophthalmic lenses were determined after the application of tearing-off with tape, rubbing with acetone, soaking in acetone or distilled water of ophthalmic lens (CR-39 material) as physical and/or chemical stimuli. Results: The change of ophthalmic lens surface was detected after soaking in acetone for longer than 30 minutes by observing the lens surface to figure out the functional change of hard coating. The ophthalmic lens soaked in distilled water for 180 minutes showed little functional change of anti-reflection coating as 1% by measuring light transmittance of lens. However, the function of anti-reflection coating was almost disappeared after the ophthalmic lens was soaked in acetone for 60 minutes. The foggy duration of ophthalmic lens soaked in acetone was increased by estimating foggy duration of lens. The lens coating was shown to be defected when the pre-damaged ophthalmic lenses were torn off with tape, rubbed with acetone and soaked in distilled water or acetone by observing pre-damaged lens surface to evaluate its durability. Conclusions: The careful management during ophthalmic lens dispensing or usual eyeglass wearing is needed since the change in ophthalmic lens coatings was shown by repeated physical and/or chemical stimuli.

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Impact Resistance Testing of NK55 Ophthalmic Lenses in Domestic Market (국내 유통 NK55 재질 안경렌즈의 내충격 시험 평가)

  • Park, Mijung;Jeon, Inchul;Hwang, Kwang Hoon;Byun, Woongjin;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • Purpose: The present study was performed to evaluate the safety of ophthalmic lenses in domestic market since eyeglasses wearers could be exposed to the negligent accident by damaged ophthalmic lenses. Method: Totally, 160 ophthalmic lenses (NK55, ${n_{d}}$ = 1.56) with the refractive powers of -3D, -6D, +3D, +6D manufactured by 4 companies in domestic market were evaluated using drop ball test. In accordance with FDA standard, steel ball (~16 g) was freely dropped on these ophthalmic lenses from 127 cm high and the surfaces of lenses were observed. Results: From the study, center thicknesses of NK55 ophthalmic lenses manufactured by 4 different companies showed somewhat different numbers even though the lenses had the same refractive index and powers. All convex lenses of +3D, +6D were evaluated as the safe lenses since there was no damage such as crack and broken found on the lens surfaces after drop ball testing. However, some noticeable broken was shown on the surfaces of concave lenses with relatively thinner center thickness. Especially, 59(73.8%) of total 80 concave lenses with the refractive power of -3D and -6D classified as unacceptable lenses to FDA standard. Conclusions: From the results, the negligent accident by damaged ophthalmic lenses should be considered as well as the correction of visual acuity, design and price when customers purchase eyeglasses. Thus, the enforcement regulation like drop ball testing of uncut ophthalmic lens could be suggested to guarantee the safety of ophthalmic lenses in domestic market.