• Title/Summary/Keyword: 안경착용

Search Result 189, Processing Time 0.024 seconds

Induced Prisms of Wearing Glasses Measured by Photographing (사진촬영으로 측정한 착용안경의 유발프리즘)

  • Shin, Hyung-Sup;Jang, Jun-Kyu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.527-532
    • /
    • 2014
  • Purpose: The matching of the optical center and the pupil center was measured by photographs in wearing glasses. In this study, the influences of the induced prism by the mismatching are studied. Methods: 74 subjects (148 eyes) who were spectacles wearer were participated in this study. The mean age was $29.19{\pm}12.22$ years (range 19-55 years). The facial photographs of subjects were taken while wearing spectacles. The matching of the corneal reflected image and optical center of the spectacle lens in the horizontal deviations, and the vertical deviations were measured by the observation of the photo image. The prisms induced in accordance with various frame type were calculated from the mismatching deviations. Results: The binocular horizontal deviations were $1.55{\pm}1.70mm$ for the metal frame, $1.71{\pm}2.21mm$ for the clings type plastic frame, and $1.15{\pm}1.38mm$ for the plastic frame. In the horizontal direction induced prism, the ratio over the tolerance was 23%. The ratio were the 17.6% at the BI prism, and 5.4% at the BO prism. The binocular vertical deviation comparisons were $3.93{\pm}1.91mm$ for the metal frame, $5.79{\pm}1.93mm$ for the clings type plastic frame, and 1$6.01{\pm}2.94mm$ for the plastic frame. In the vertical direction induced prism, the ratio over the tolerance was 44.6%. Based on the refraction power, the ratio were 12.2% at -0.25${\leq}-3.00$, and 32.4% at -3.00${\leq}-12.00D$. Conclusions: The induced prisms in the horizontal direction were much in the BI prism. The binocular vertical deviations of the glasses.

다시점 3D 영상 기술

  • Eom, Gi-Mun;Kim, Tae-Won;Jang, Eun-Yeong;Sin, Hong-Chang;Jeong, Won-Sik;Heo, Nam-Ho
    • Information and Communications Magazine
    • /
    • v.28 no.6
    • /
    • pp.21-30
    • /
    • 2011
  • 본고에서는 안경식 3DTV가 가지고 있는 안경착용의 불편함을 해결할 수 있는 무안경 3DTV 개발을 위한 다시점 3D 영상 기술에 대해 기술한다. 다시점 3DTV 서비스를 위해서는 다시점 3D 영상 획득, 부호화 기술, 재현 및 디스플레이 기술 등의 개발이 필요하며, 본 고에서는 이들 기술에 대해 간략하게 소개하기로 한다.

Subjective Symptoms according to Fitting Test in Soft Contact Lens Wearers (소프트콘택트렌즈 착용자의 피팅 상태 확인 유무에 따른 자각적 증상)

  • Kim, Jung-Hee;An, Youngju
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.431-442
    • /
    • 2018
  • Purpose : The purpose of this study was to investigate subjective symptoms according to the wearing, purchase and fitting status of soft contact lens wearers, and consumer perception of base curve. Methods : A survey was conducted for those who visited optical shops and lens shops in Seoul from June to August 2018. A total of 98 answer sheets they submitted were used for the analysis. The chi-square test and Fisher's exact test were used to compare subjective symptoms (dryness, glare, uncomfortable fitting, and decreased vision) according to whether fitting condition is screened (case history and push-up test, ect relevant to wearing sensation), and the odds ratio (OR) was obtained by the logistic regression analysis. Results : When the contact lenses were purchased, the rate of which the visual acuity test was performed was 86.6% at optical shop and 64.7% at lens shop. When purchasing contact lens and the contact lens was not tested for fitting, they more experienced dryness (OR 4.41, 95% CI 1.25-15.62) and uncomfortable fitting (OR 2.68, 95% CI 1.08-6.64) than testing for fitting. In addition, it was investigated that 87.8% of contact lens wearers did not know about the term base curve, 92.9% did not listen to an explanation related to the base curve when purchasing contact lenses, and 96.9% did not experience with base curve test. Conclusion : It would be thought that satisfaction of the contact lens fitting of existing consumers should be improved by changing a proper base curve by confirming the fitting condition when prescribing soft contact lens.

Function of Medical device on spectacle frame (안경테의 의료용구적기능)

  • Kang, H.S.;Seo, Y.W.;Kang, I.S.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.41-51
    • /
    • 1996
  • According to Korean pharmaceutic law, spectacles is a kind of medical device or instrument that is composed of a front and two temples with a pair of lenses. If the spectacle is not worn, it is a kind of optical device, but if it were worn, it will makes a new optical system to correct ametropia. Therefore, spectacles must be carried on by dispensing opticians.

  • PDF

Comparative Effect of Spectacles and Orthokeratology Lenses on Axial Elongation in Children with Mild-to-Moderate Myopia (중등도 이하 소아 근시에서 안경과 각막굴절교정렌즈 착용이 안축장 성장에 미치는 영향 비교)

  • Kim, Tae Hee;Kim, Myung Hun;Kwag, Joo Young;Choi, Jin Seok;Pak, Kyu Hong;Lee, Kyeongwook;Park, Taeseong;Chung, Sung Kun;Hyun, Joo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1009-1016
    • /
    • 2018
  • Purpose: To assess the effect on axial elongation and associated factors between spectacles and of orthokeratology lens (OK) wearing in children with mild to moderate myopia. Methods: A total of one hundred subjects, ranging in age from 6 to 13 years, and with mild to moderate myopia no more than -4.50 diopters in spherical equivalent, visited our clinic from 2013 to 2015. The OK group (75 eyes) and the spectacles group (64 eyes) were compared and analyzed on the axial elongation and associated factors. Results: In the OK group, axial length was elongated in 1 year period with a mean increase of $0.24{\pm}0.29mm$. In spectacles group, axial length was elongated in 1 year period with a mean increase of $0.42{\pm}0.20mm$. The statistically significant suppression of axial elongation was observed in OK group compared to the spectacles group (Mann-Whitney U test, p < 0.05). For OK group, the age of starting OK (Pearson's correlation, r = -0.481, p < 0.05) was the only influencing factor on axial elongation, which had negative correlation with axial elongation. In spectacles group, the age of starting spectacles had negative correlation with axial elongation (Pearson's correlation, r = -0.462, p < 0.05) and baseline spherical equivalent, spherical diopter, cylindrical diopter from manifest refraction had positive correlation with axial elongation. Comparison of axial elongation in orthokeratology lens group and spectacles group by age groups (6 to 9 years [28 eyes], 9 to 13 years [47 eyes]), 9 to 13 years of orthokeratology lens group had the stronger suppression of axial elongation (Mann-Whitney U test, p < 0.05). Conclusions: The OK effectively suppresses axial elongation compared to the spectacles. Although the patients are in age from 9 to 13 years, the axial elongation was effectively suppressed.

The Research of Fitting Status of R.G.P Lenses Inspected by Optometrists in In-Cheon and Kyung-Gi Region (인천·경기지역 안경사들을 대상으로 한 R.G.P 렌즈 착용 실태 조사)

  • Kim, In-Suk;Kim, Young-Pil;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.27-33
    • /
    • 2007
  • This research investigated the effects of spherical and aspherical R.G.P lenses which was performed by optometrists in In-Cheon and Kyung-Gi region. This research survey included various questions such as the fitting status, after-care method, preliminary test. Results of the survey revealed that the optometriests sold the asperical and spherical lenses with a ratio of 7:3, respectively, and most of them did not cheked Topography, Fluorescein test by slit lamp biomicroscope, Tear Break up time test, Schirmer test and so on. And, with fitted R.G.P lenses symptoms like light odd-feeling, congestion, eye-stimulus, dimness and dryness were frequently reported. The purposes of this study are to search for the ideal fitting check of R.G.P lens and remind the most important preliminary test for contact lens fitting.

  • PDF

Contrast Sensitivity and Glare with Spherical and Toric Soft Contact Lenses in Low-astigmatic Eyes (구면과 토릭 소프트 렌즈로 교정한 약도 난시안의 대비감도와 눈부심)

  • Lee, Min-Ah;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • Purpose: The purpose of this study is to compare the visual performance by contrast sensitivity (CS) and disability glare (DG) in low astigmatic eyes corrected with toric soft lenses and other optical corrections. Methods: Twenty university students with myopia (-1.00 to -6.50D Sph. with astigmatism up to 1.50 cyl) were enrolled and corrected by five different methods: 1) soft toric lenses; 2) spherical soft contact lenses; 3) RGP lenses; 4) best spectacle corrected visual acuity; 5) spherical equivalent spectacles. All subjects had corrected vision acuity of 20/20 or better. Contrast sensitivity and disability glare were measured using the OPTEC 6500 contrast sensitivity view-in tester included the EyeView Functional Vision Analysis software at photopic or mesopic conditions with glare. Results: At photopic condition, best corrected spectacle wearers had the highest monocular contrast sensitivity at all spatial frequency followed by soft toric lenses, RGP lenses, spherical equivalent spectacles, and spherical soft contact lenses. However, all of them were in normal contrast sensitivity value at photopic condition. At mesopic condition with glare, toric soft lenses were the highest and followed by RGP lenses, spherical equivalent spectacles, best spectacle corrected visual acuity and spherical soft contact lenses. It was observed that spherical soft contact lens wearers demonstrated lower range than normal contrast sensitivity value at mesopic condition with glare. Conclusion: Toric soft lenses gave better visual performance than spherical soft lenses in low astigmatic eyes. Subjects requiring the use of contact lenses under mesophic conditions could benefit from toric soft lenses.

  • PDF

Related Factors with Decreased Visual Acuity of Elementary School Students (초등학생의 시력저하 관련요인)

  • Mun, Kyeoung-Ae;Lee, Moo-Sik;Na, Baeg-Ju;Lee, Jin-Yong;Hong, Jee-Young;Bae, Seok-Hwan;Yoo, Se-Jong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.677-680
    • /
    • 2010
  • 본 연구는 경기도 구리시의 2개 초등학교 5, 6학년 학생을 대상으로 시력 저하 실태 및 그와 관련된 요인들을 알아보고 시력 저하 예방교육의 기초자료로 활용하고자 시도 된 연구이다. 자료의 수집은 2009년 11월 1일부터 12월 10일까지 초등학교 5학년, 6학년 학생 793명(남 417명, 여 376명)이었고 2009학년도의 시력검사자료 분석과 문헌 및 기존의 조사도구를 토대로 개발한 자가 보고식 설문지를 이용하여 조사하였다. 자료 분석은 SPSS WIN 12.0(한글판)프로그램을 이용하여 빈도, 백분율, $x^2$-test 및 로지스틱 회귀분석의 통계적 방법으로 분석하였다. 시력저하에 유의한 영향요인으로 좌측시력을 종속변수로 한 경우 중 일반특성에 따른 변수인 부모 및 형제와 자매가 안경 및 렌즈 착용하는 경우, 경제적으로 어려울수록 시력 저하 자가 많았고, 환경특성에 따른 변수인 거실 및 방안밝기가 어두울수록, 컴퓨터 사용 시 실내밝기가 어두울수록, TV의 눈높이 및 컴퓨터 모니터의 눈높이가 높을수록 시력 저하 자가 많았다. 우측시력을 종속변수로 한 경우 중 일반특성에 따른 변수인 부모가 안경 및 렌즈를 착용할수록, 형제 와 자매가 안경 및 렌즈를 착용할수록, 경제적으로 어려울수록 시력 저하 자가 많았고, 환경특성에 따른 변수인 거실 및 방안밝기가 어두울수록, 컴퓨터 사용 시 실내밝기가 어두울수록, TV의 눈높이 및 컴퓨터 모니터의 눈높이가 높을수록 시력 저하 자가 많았다. 안경 및 렌즈를 종속변수로 한 경우 중 일반특성에 따른 변수인 부모 및 형제와 자매가 안경 및 렌즈를 착용할수록, 경제적으로 어려울수록 시력 저하 자가 많았으며, 환경특성에 따른 변수인 거실 및 방안밝기의 실내밝기가 어두울수록, TV의 눈높이 및 컴퓨터 모니터의 눈높이가 높을수록 시력 저하 자가 많았다. 눈 건강상태를 종속변수로 한 경우 중 일반특성에 따른 변수인 경제적으로 어려울수록 시력 저하 자가 많았고, 건강행동특성에 따른 변수인 주관적인 건강상태가 나쁠수록, 눈 피로감이 있을수록 시력 저하 자가 많았으며 환경특성에 따른 변수인 거실 및 방안밝기의 실내 밝기가 어두울수록 시력 저하 자가 많았다. 시력저하관련 요인을 연구한 결과 학생들의 시력 저하 자가 매년 증가하고 있다는 것을 알 수 있었고, 유전적 요인에 의한 시력저하는 개인의 노력에 의하여 사전예방이 어렵지만 환경적 요인에 의한 시력저하는 노력과 관심으로 사전예방이 가능하므로 학생들의 시력건강증진을 위하여 학부모와 학교 및 전문 의료기관이 서로 연계적인 협조 하에 학생들 개개인에 맞는 효율적인 시력증진관리프로그램 개발하는 것이 필요하고, 현행학교시력검사의 정확성을 기하기 위하여 표준화된 시력검사 지침을 개발하여 사용할 필요가 있으며, 지역 및 환경적 배경이 다르다 보니 연구결과가 다르게 나타나는 경우가 있는데 객관적인 결과를 도출하기 위하여 여러 지역의 학생을 대상으로 다양하고 체계적인 연구를 해야 할 필요성이 있다고 생각한다.

  • PDF

Exploratory studies of the music analgesic effect in people with glasses through cold-pressor task (안경 착용 여부에 따른 음악 통증완화효과의 탐색적 연구)

  • Choi, Suvin;Park, Sang-Gue
    • The Korean Journal of Applied Statistics
    • /
    • v.33 no.6
    • /
    • pp.823-832
    • /
    • 2020
  • The analgesic effects of music in people with glasses on perceived pain through cold-pressor task (CPT) is assessed based on three-sequence, three-period, crossover trial with three treatment conditions(music-listening, news-listening, and no-sound) to each subject. Fifty subjects are divided into three sequence groups by randomization, and CPTs under the pre-assigned treatment conditions at each period are performed. Pain responses after each CPT, subjects' pain tolerance (PT) in time scale and pain intensity (PI) and pain unpleasantness (PU) in visual analog scale (VAS) are measured. After classifying the group by whether or not to wear glasses, which is the phenotype of the myopia gene, pain responses are compared by F-tests and Tukey's multiple comparisons. CPT pain responses in group with glasses during the music intervention are significantly different from responses during the news intervention and the control conditions, respectively. This study investigates the pain responses of music intervention in the group wearing glasses, which can be seen as a phenotype of the nearsighted gene, and this result would play a role in explaining the biopsychosocial model of the pain mechanism.

Analysis on Key-factors in Worsening of Eyesight for Schoolchildren as a Consequence of Computer Usage Time (컴퓨터 사용 시간에 따른 초등학생의 시력저하 요인 분석)

  • Joo, Heon-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.477-486
    • /
    • 2011
  • In this paper, I had tried to analyze the relationship between the time assigned for computer usage and weakening eyesight. First of all, students classified by gender, school year, eyesight, and wearing glasses along demographic characters took part in a poll, and The questionnaire included questions about computer time, factors of weakening eyesight, and purpose of computer use. The finding in this analysis composed of a cross-tabulations between annual eyesight change and the factors to change their eyesight is that 63.6 % of 165 students participated in this survey weakened their eyesight within a year. To show a correlation between computer usage duration and worsening eyesight in this paper, regression analysis indicated weakened vision by computer usage duration per day and week instead of a year. In addition, according to the analysis between computer usage duration and weakened vision for the people who wear glasses or not trough Independent-Samples T test, weakened vision was shown in computer usage duration per day and week, but not shown in the duration by the year. Therefore, weakening vision was also worse for the people who didn't wear glasses than the others. This study indicated 24..5% of teenagers had poor eyesight by using their computer. According to the frequency analysis on purposes of computer usage, the biggest purpose accounting for 36.4% of the total was the computer usage as a game consol, and the computer as a learning tool was the next biggest purpose at 32.1%. This paper showed the correlation between computer usage time and a factor of weakened eyesight through an analysis of the factor. Therefore, schoolchildren's parents should be more interested in their computer usage.