• Title/Summary/Keyword: 안경종류

Search Result 80, Processing Time 0.022 seconds

A Comparative Study on Test Methods for Ophthalmic Lens Coatings (안경렌즈 코팅의 평가 방법에 관한 비교 연구)

  • Yu, Dong-Sik;Moon, Byeong-Yeon;Ha, Jin-Wook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.7-15
    • /
    • 2006
  • We have surveyed test methods for ophthalmic lens coatings and compared the coating quality of lenses supplied by manufactures. Plastic ophthalmic lenses are produced in increasingly larger volumes. However, their softness have need resistant coatings absolutely essential in most cases. Coating lenses are typically evaluated in physical and chemical properties through random selection from produced lenses. No international standard test methods for ophthalmic lenses exist for issues such as adhesion, abrasion resistance, hardness, chemical and hot water resistance with exception of transmittance. We have learned that there is a great deal of confusion regarding the methods employed in the various tests for ophthalmic coating lenses. For this reason, test methods for ophthalmic lens coatings are needed making all of international or domestic standards available.

  • PDF

Analysis on Specification of Wearable Devices (웨어러블 장치의 스펙 비교 분석)

  • Park, Jin-Won;Kim, Kyoo-Mok;Lee, Jon-Ha;Park, Ji-Yeol;Jung, Seung-Won
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.776-777
    • /
    • 2016
  • 현재 스마트폰을 뒤이을 차세대 스마트 장치들로 구글글래스(Google Glass) 등과 같이 사람이 몸에 착용하는 웨어러블 장치들이 주목 받고 있다. 현재까지 스마트 안경, 스마트 팔찌, 스마트 시계, 스마트 반지 등 수많은 종류의 웨어러블 장치들이 출시되었고 각기 다른 사양을 갖는다. 본 논문에서는 이러한 웨어러블 장치들 중에서도 안경형 장치인 스마트 안경들의 스펙에 대해 분석한다.

A Study on the Effective Display Method of Optician's Shop (안경원의 효율적인 디스플레이 방법에 관한 연구)

  • Han, Sun-Hee;Kim, Bong-Hwan;Han, Myung-Hee;Kim, Chung-Mi;Lee, Seung-Hyun;Jin, Kang-Hun;Lee, Hae-Jin;Jeong, Hyo-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • Purpose: The purpose of this study was to research the display of optician's shop through questionnaire to suggest the direction for more effective display method. Methods: The study visited 50 optician's shops located in main area of Ulsan (university street, downtown and residential street), performed questionnaire and researched optician's display preference. Results: The displays preferred by opticians were as follows. They displayed contact lens in entrance of shop, displayed sunglasses in the wall rather than displayed them in the center of shop and displayed medium or low price products in the center so that consumers could access them conveniently. In addition, they prepared resting place for customer's convenience by locating it in entrance or inside of shop. Conclusions: It seems that effective display of optician's shop can attract consumer's mind and improve purchase, resulting in significant change of optician's shop sales. Therefore, it is necessary to perform the study to use systematic, discriminated display strategy so that shop image can be controlled consistently and continuously.

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.

Analysis of Vertex Refractive Power Accuracy of Soft Contact Lens with Holder Type (홀더종류에 따른 소프트 콘택트렌즈의 정점굴절력 측정의 정확도 분석)

  • Lee, Min-Jae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.105-115
    • /
    • 2015
  • Purpose: The accuracy for measuring the refractive power of hydrogel contact lenses by spectacle lens holder and contact lens holder was evaluated. The accuracy for each sample was also analyzed with water content and diopter categories. Methods: The hydrogel contact lenses used for measurement were classified into three categories in water content (38%, 43%, 58%). Also, three diopter categories of refractive power were used such as -3.000 D, -7.000 D, -10.000 D. And also, the reliability of measurement results were evaluated by measuring refractive power with spectacle lens holder and contact lens holder using an Manual lensmeter. Results: In case of spectacle lens holder method, the average value of refractive power was -3.3273D for -3.0000 D, -7.1306 D for -7.0000 D and -10.2944 D for -10.0000 D, respectively. In case of contact lens holder method, the average value of refractive power was -3.1060 D for -3.0000 D, -7.0028 D for -7.0000 D and -10.2611 D for -10.0000 D, respectively. In measurement of all diopters, the accuracy of contact lens holder method was better than spectacle lens holder method. Conclusions: From these results, it is judged that the refractive power of soft contact lens by manual lensmeter with contact lens holder have a higher accuracy than spectacle lens holder.

A study on the fitting method for children's spectacles (소아(小兒) 안경(眼鏡)의 fitting에 관(關)한 고찰(考察))

  • Kim, Dae Nyoun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.73-84
    • /
    • 1996
  • Satisfactory for children's spectacles fitting can only be achieved with the resonable selection and assortment of frames of different pad shapes, size, materials, the general property of sample frame are flexibility for the temple. Loughness for bridge and variety for the length of temple, a selection of the lens is chosen usually by the characteristic of the power, safty, size and so on, it will be comport fit of frame controlled the hight and width of pad and angle of pad between the nose side, frontal angle of pad will be determinded that whether a frame may be capable of providing a comport fit. An important part of the fitting of spectacles is the final adjustment before the wearer takes them away, and also their continued adjustment to maintain the optimum comport and lens efficiency. It is suggested that spectacle adjustment is essentially a practical art that can only be acquired by continual practice.

  • PDF

Analysis of Adaptation for The first-time Progressive Lenses Glasses Wearers (누진렌즈 안경 처음 착용자의 적응도 분석)

  • Shim, Jun-Beom;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.117-122
    • /
    • 2011
  • Purpose: This study analyzed the factors related to adaptation of people who wears progressive lenses glasses for the first time. Methods: 463 presbyopia (Aged 41~78) without any ocular diseases with the progressive lens glasses were prescribed from 2010 to 2011 at B clinic in the Gwangju city. Progressive lenses adaptation were analyzed according to gender, age, distance refractive state, presbyopic addition, progressive lens design, the old glasses, astigmatism type, and anisometropia etc. High, mid and low-adapted groups were categorized as the status of wearing progressive lenses glasses, re-wearing, occasionally wearing and failed to weraing, respectively. Results: Men showed significantly higher adaptation (p=0.02) than women. Presbyopic addition (p=0.05) and progressive lens design (p=0.02) were statistically significant. However, it was found that there was so statistical significance for the factors of age, distance refractive state, the old glasses, astigmatism type, and anisometropia. Conclusions: According to the results of this study, when progressive lenses were prescribed, we should consider for adaptation gender, presbyopic addition, and progressive lens design etc.

Survey on Contact Lens Wear Status in Gyeonggido (경기도 지역 콘택트렌즈 착용실태 조사)

  • Song, Yun-Young;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.373-378
    • /
    • 2014
  • To investigate the wear status of contact lenses by analyzing care of contact lenses container and actual condition of people wearing contact lenses and in Gyeonggido. The results were based on a questionnaire survey of 200 people who are the students of the middle school, the high school and the college among the clients of opticians to purchase contact lenses for six months from January 2013 to July 2013. According to the poll, the highest number of those polled, 139 (55.16%) people, said they were wearing cosmetic color contact lenses. Female respondents and male respondents were in the proportion of 177 (88.5%) to 23 (11.5%), respectively. 37 people (18.5%) who responded said "yes" to the question of them sharing contact lenses and glasses. 103 people (51.5%) answered "no" to the question of regularly replacing their lens containers. 148 people (74%) answered "yes" to the question of having glasses in order to investigate contact lens wearers user rate of glasses. The highest number of respondents, 127 people (63.5%), said "middle school" was the first time that they wore contacts. Meanwhile, 65 people (43.92%) said they initiated wearing glasses at 4th-6th grades. It is considered that it is necessary using proper contact lenses suitable for the clients' eye health in order of vision correction, rather than for cosmetic purposes. The role of the optician is considered to be very important for the proper management of the appropriate contact lens hygiene and regular optical check-ups of the contact lens wearers.

Effect of CaO on Mechanical Properties of SiC materials for spectacle lens cutting (CaO첨가가 렌즈 절삭용 실리콘카바이드재료의 기계적 특성에 미치는 영향)

  • Lee, Young-Il;Shin, Dong-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.19-23
    • /
    • 2007
  • An investigation of the effects of CaO on microstructure and properties of SiC materials for spectacle lens cutting was described. Four materials with different composition have been fabricated by hot-pressing at $1,880^{\circ}C$ for 4h using CaO. SEM analysis and XRD of the surface of samples were carried out. Typical fracture toughness of materials for spectacle lens cutting was $5.4MPa{\cdot}m^{1/2}$. Also, The hardness of materials for spectacle lens cutting was relatively dependent on the density.

  • PDF

A Study on the Spectacles Wearing State of High School Students (고등학생들의 안경착용에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • This study is of investigation of refraction error, spectacles and contact lenses wearing state, visual acuity test, ophthalmologic common sense and vision care, using questionnaire study for 850 male and female high school students in Kunsan and Chongup City, Cheolla North Province. The results are as follows: 1. Among the 823 answerers, emmetropia is 18%, myopia is 55.1%, and hyperopia is 7%, respectively. 2. Among the 837 answerers, 381 students(45.5%) wear spectacles or contact lenses. Among the 381 students who wear spectacles or contact lenses, 78% wear only spectacles, 4% wear only contact lenses and 18% wears spectacles sometimes or contact lenses sometimes. 3. The places where the answerers had visual acuity test to wear spectacles or contact lenses are optical shop(64.7%), hospital(28.3%), unchecked(4.2%) and the others(2.7%). The places where the answerers had visual acuity test to change their spectacles or contact lenses are optical shop(82%), hospital(28.3%), unchecked(6.6%) and the others(1.9%). 4. As for the period of visual acuity test, from 6 months to one year is 54.1%, within 6 months is 9.2%, from one year to two years is 29.5%, and more than two years is 7.2%. 5. The contact lens wearers purchased their contact lenses at optical shops(94%) and at hospital(6%). 6. The reasons why they like wearing contact lenses are their appearance(51.2%), convenience in physical excercise(23.l%), lighter weight than spectacles(9.8%) and the others(15.7%). 7. As for the spectacles frame they like, plastic frame is 24.4%, gold or silver plated frame is 43.4%, coloured frame is 32.1%. 8. As for the considerations in choosing spectacles frame, their design is 37%, their quality is 36%, their price is 14.7% and their brand is 12.5%. 9. As for the period for changing spectacles, 10.5% is within 6 months, 57.3% is 6months to 1 year, 22.4% is 1 year to 2 months and 9.6% is more than 2 years. 10. There is a false fact, in Korea, that even though one has his poor eyesight, not wearing custom is helpful for the eyesight recovery. As for their conviction of the false fact, 10.5% of the answerers have 100% conviction, 22.5% of them have 22.5% conviction, 49.5% of them have 50% conviction and 17.5% of them don't have any conviction. 11. 48.5% of the answerers are interested in their vision care while 51.5% of them are not interested at all. As for the way of vision care, the vision-care way to keep enough distant when they are watching TV, when they are using computers and when they are reading, is 49% while the vision-care way such as hypogastric breathing or eye massage is 11%. And alimentotherapy is 4% and the rest who are not interested in vision care is 36%. 12. When they come to an age, the students who want vision correction operation are 45.9% while the students who do not want it are 27%. The students who do not have any idea about the operation are 27.1%

  • PDF