• Title/Summary/Keyword: 아크채널

Search Result 10, Processing Time 0.031 seconds

Analytical Analysis of Segmented Arc Plasma Torch for Plasma Wind Tunnel Facility (플라즈마 풍동 시설용 분절형 아크 플라즈마 토치의 이론적 설계변수 해석)

  • Seo, Jun-Ho;Choi, Soo-Seok;Choi, Seong-Man;Hong, Bong-Guen
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.4
    • /
    • pp.85-93
    • /
    • 2011
  • A parametric study is conducted for the design of segmented arc plasma torch with the input power and current of 0.4 MW and 300 A, respectively. For this purpose, we use the analytical relationship between input power, current condition, plasma temperature, inner diameter (R) and length (L) of the torch constrictor based on arc channel model. The results reveal that arc plasma temperatures increase monotonically as ��L increases or R decreases for the ranges of R ${\leq}$ 7.5 mm and L ${\leq}$ 1.25 m. For larger valuse of ��R and L than 7.5 mm and 1.25 m, respectively, however, they show non-linear behavior corresponding to the variations of ��L, which stands for the generation of unstable arc plasma. From this parametric study, optimum ranges of R and L are suggested as 5.5 mm ${\leq}$ R ${\leq}$ 7.5 mm and 0.25 m ${\leq}$ L ${\leq}$ 0.5 m for 0.4 MW class segmented arc plasma torch, under which stable arc plasma can be achieved at the input currents of ~300 A.

Analytical Analysis of Segmented Arc Plasma Torch for Plasma Wind Tunnel Facility (플라즈마 풍동 시설용 분절형 아크 플라즈마 토치의 해석적 설계변수 해석)

  • Seo, Jun-Ho;Choi, Soo-Seok;Choi, Seong-Man;Hong, Bong-Gun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.768-774
    • /
    • 2010
  • A parametric study is conducted for the segmented arc plasma torch with the input power and current of 0.4 MW and 300 A, respectively. For this purpose, we use the analytical relationship equations between plasma temperature, inner diameter (R) and length (L) of the torch constrictor at the given input power and current conditions based on the arc channel model. The results reveal that arc plasma temperatures show non-linear behavior or absence corresponding to the variations of L and R when their values become larger than 1.25 m and 7.5 mm, respectively. For L < 1.25 m and R < 7.5 mm, however, they can increase monotonically as L increase or R decrease when one of both parameters is fixed. From these parametric study results, optimum ranges of R and L are suggested as $5.5mm{\leq}R{\leq}7.0mm$ and $0.5m{\leq}L{\leq}1.0m$ for 0.4 MW class segmented arc plasma torch, under which stable arc plasma with the temperatures of ~15,000 K can be achived at the input currents of ~300 A.

  • PDF

Fluid Flow Resistance in a Channel with Wire-screen Baffles (와이어 스크린 배플이 설치된 채널에서의 유체유동 저항)

  • Oh, S.K.;Ary, B.K.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.36-41
    • /
    • 2009
  • An experimental investigation was conducted to examine the fluid flow resistance in the rectangular channel with two inclined wire screen baffles. Two different types of wire screens; dutch weave and plain weave, were used as baffle devices in this experiment. Three kinds of baffles with different mesh specifications were made up of dutch type and four different kinds of baffles were made up of plain weave type. The stainless steel wire screen baffles were mounted on the bottom wall with varied angle inclination. Reynolds numbers were varied from 23,000 to 57,000. Results show that the mesh number of baffles plays an important role on friction factor behaviour. It is found that the baffle with the most number of meshes (type SA) has the highest fluid flow resistance.

  • PDF

Heat Transfer and Friction Factors in the Channel with an Inclined Square Diamond Type Perforated Baffle (정 다이아몬드 형 구멍이 있는 배플을 가진 채널에서의 열전달과 마찰계수)

  • Oh, S.K.;Putra, A.B.K.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.26-31
    • /
    • 2008
  • This experimental study investigates the local heat transfer enhancement characteristics and the associated frictional head loss in the rectangular channel with a single inclined baffle. Four different types of the baffle are used. The inclined baffles have the width of 19.8 cm, the square diamond of $2.55cm{\times}2.55cm$, and the inclination angle of 5o, and number of holes of up to 9. Reynolds number is varied between 23,000 and 57,000. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle. It is found that the heat transfer performance of baffle type II(3 hole baffle) has the best values.

  • PDF

Effects of Swirl Flow Generated by Twisted Tape on Beat Transfer and Friction Factor in a Square Channel (사각 채널에서 테이프에 의한 스월유동이 열전달과 마찰계수에 미치는 효과)

  • Ahn, Soo-Whan;Kang, Ho-Keun;Putra, Ary Bachtiar Krishna
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.11
    • /
    • pp.912-917
    • /
    • 2007
  • Regionally averaged heat transfer distributions and friction factors in square channels with twisted tape inserts and with twisted tape inserts plus interrupted ribs are experimentally investigated. The effects of surface heating condition on heat transfer enhancement are also investigated. Each wall of the square channel is composed of isolated aluminum plates. The interrupted square ribs are arranged along the axial flow direction on the bottom wall only. Experimental tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The results are compared with those of previous investigations for circular tube with axial interrupted ribs and twisted tape inserts.

Analysis Of Dielectric Recovery Characteristics for $SF_6$ Gas-Blast AFC ($SF_6$아크의 절연회복특성 해석)

  • Song, Gi-Dong;Lee, Byeong-Yun;Park, Gyeong-Yeop;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.273-284
    • /
    • 2002
  • In this paper, computer simulations of the physical Phenomena occurring in the arc region before and after current zero were carried out to evaluate the dielectric recovery characteristics of two types of double-flow nozzles. A commercial CFD Program "PHOENICS" is used for the simulation and the user-coded subroutines to consider the arcing phenomena were added to this program by the authors. The computed results were verified by the comparison with the test results presented by the research group of BBC. In order to investigate the state of the arc region after current zero, the simulation was carried out with four steps. They are cold gas flow analysis, steady state arc simulation, transient arc simulation before current zero, transient hot gas flow simulation after current zero. The semi-experimental arc radiation model is adapted to consider the radiation energy transport and Prandtl′s mixing length model is employed as the turbulence model. The electric field and the magnetic field were calculated with the same grid structure used for the simulation of the flow field. The streamer criterion was introduced to evaluate the dielectric recovery characteristics after current zero. Compared with the results obtained by assuming the current zero state in the former studies, it has been found that the results obtained by considering the state before current zerowere more accurate.

The Characteristics of Heat Transfer in a Channel with Wire-screen Baffles (와이어 스크린 배플이 설치된 채널에서의 열전달 특성)

  • Kim, W.C.;Ary, B.K.;Ahn, S.W.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.11-17
    • /
    • 2009
  • The heat transfer characteristics of flow through two inclined wire-mesh baffles in a rectangular channel were investigated experimentally with varying the mesh number of wire screens and inclination angle of the baffles. Two different types of wire meshes such as dutch and plain weaves, were used in this experiment. Three kinds of baffle plates with different mesh specifications in the dutch weave and four different kinds in the plain weave were manufactured. Baffles were mounted on bottom wall with varied angles of inclination. Reynolds number was varied from 23,000 to 57,000. It is found that the placement of inclined wire-mesh baffles in the channel affects the heat transfer characteristics by combining both jet impingement and flow disturbance. The wire screen modified the flow structure leading to a change in the heat transfer characteristics. The results show that the baffle plate with the most number of mesh (type SA) has the highest heat transfer rate.

  • PDF

Effects of Tape on Heat Transfer and Friction Factor in a Square Channel (사각 채널에 설치된 테이프가 열전달과 마찰계수에 미치는 효과)

  • Ahn, Soo-Whan;Kang, Ho-Keun;Bae, Sung-Taek;Putra, Ary Bachtiar Krishna
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2402-2407
    • /
    • 2007
  • Heat transfer distributions and friction factors in square channels (3.5 ${\times}$ 3.5 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are respectively investigated. Tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The rib height-to-channel hydraulic diameter, e/Dh, is kept at 0.057 and test section length-to-hydraulic diameter, L/Dh is 30. The twisted tape is 0.1 mm thick carbon steel sheet with diameter of 3.3cm, length of 90cm, and 2.5 turns. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. Each wall of the square channel is composed of isolated aluminum sections. The following conclusions from the experimental study were drawn as: 1) In the 4 heating wall channel with twisted tape inserts, Nusselt number based on bottom wall temperature is enhanced by 1.2 - 1.6 times if adding the axial interrupted ribs on the bottom wall only. 2) The twisted tape with interrupted ribs under the two-sided heating condition produces the highest heat transfer performance. 3) Friction factor data obtained for the square channel with twisted tape inserts plus axial interrupted ribs are less than those in the past publications for circular tubes with axial interrupted ribs and twisted tape inserts.

  • PDF

Effects of Swirl Flow Generated by Twisted Tape on Heat Transfer and Friction Factor in a Square Duct (꼬임식 테이프가 설치된 사각 덕트에서 스월유동이 미치는 열전달과 마찰계수)

  • Kang, Ho-Keun;Ary, Bachtiar-Krishna-Putra;Ahn, Soo-Whan
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.117-120
    • /
    • 2008
  • Numerical simulations and experiment of a hydrodynamic and thermally developed turbulent flow through square ducts (3.0 ${\times}$ 3.0 cm) with twisted tape inserts and with twisted tape inserts plus interrupted ribs are conducted to investigate regionally averaged heat transfer and friction factors. Turbulent swirl flows having Reynolds numbers ranging from 8,900 to 29,000, a rib height-to-channel hydraulic diameter(e/D$_h$) of 0.067, and a length-to-hydraulic diameter(L/D$_h$) of 30, are considered. The square ribs are arranged to follow the trace of the twisted tape and along the flow direction defined as axial interrupted ribs. The twisted tape has 0.1 mm thick carbon steel sheet with diameter of 2.8 cm, length of 90 cm, and 2.5 turns. Each wall is composed of isolated aluminum sections, and two cases of surface heating are set. The results show that uneven surface heating enhances the heat transfer coefficient over uniform heating conditions, and square ducts with twisted tape inserts plus interrupted ribs produces the best overall transfer performance.

  • PDF

Outage Probability and Throughput Management Using CoMP under the Coexistence of PS-LTE and LTE-R Networks (안전망과 철도망 공존환경에서 협력통신을 이용한 아웃티지 및 수율 관리)

  • Lim, WonHo;Jeong, HyoungChan;Ahmad, Ishtiaq;Chang, KyungHi
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.6
    • /
    • pp.595-603
    • /
    • 2016
  • In the Republic of Korea, the LTE-based public safety (PS-LTE) network is being built for the 700 MHz frequency band. However, the same bands are also assigned to the LTE-based high-speed railway (LTE-R) network. Therefore, it is essential to utilize the co-channel interference management schemes for the coexistence of two LTE networks in order to increase the system throughput and to reduce the user outage probability. In this paper, we focus on the downlink (DL) system for the coexistence of PS-LTE and LTE-R networks by considering non radio access network (RAN) sharing and LTE-R RAN sharing by PS-LTE users (UEs) to analyze the UE throughput. Moreover, we also utilize the cooperative communications schemes, such as coordinated multipoint (CoMP) for the coexistence of PS-LTE and LTE-R networks in order to reduce the UE outage probability. We categorize the coexistence of PS-LTE and LTE-R networks into four different scenarios, and evaluate the performance of each scenario by the important performance indexes, such as UE average throughput and UE outage probability.