• Title/Summary/Keyword: 아크릴판

Search Result 66, Processing Time 0.022 seconds

Study on Shielding using CT Contrast Medium (CT 조영제를 이용한 차폐체에 대한 연구)

  • Gang, Heon-Hyo;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.693-698
    • /
    • 2018
  • Currently, shields for shielding medical radiation during medical examinations in the medical environment are lead robe and lead glass. Lead, the main component of this shielding, has limitations in lead poisoning and light weight, and high price. Iodine, which is used as contrast medium instead of lead shield, is expected to be effective as a shield because it has radiation absorbing properties. The purpose of this study was to evaluate the effectiveness of shielding by using acrylic plate filled with CT contrast agent for clinical use instead of conventional lead glass. As a result, it was found that the acrylic plate filled with the CT contrast agent showed a shielding effect of 7 times or more when the scattering ray dose was not shielded. Therefore, CT contrast agent composed of iodine is expected to be used as a shield instead of conventional lead glass.

Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect) (자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과))

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.335-341
    • /
    • 2018
  • With the improvement of medical state, patients' expectations for the most advanced medical equipment are increasing. Particularly, Magnetic Resonance Image (MRI) is used as one of the core image diagnosis methods in all clinical area. However, it has been reported that many of patients who go through the examination suffer from anxiety to the severe noise level during the examination. In this study, both the noise reduction evaluation of headsets with sound-blocking materials added to existing sound-absorbing materials and the existence of sound blocking materials as artifacts on the examination image are tested. An MRI test noise is recorded as a speaker by cross-ordination the sound material (sponge) and the sound material (acrylic plate, copper plate, and 3D copper plate) inside the headset made from 3D pring. A quantitative assessment of headsets showed that the average headset value was 81.8 dB. The average dB value of the most soundproof material combination(Copper, acrylic plate, sponge, sponge) headsets on headsets with added charactering material was measured at 70.4 dB, and MRI showed that the copper was diamagnetic substance and excluded. The second most soundproof headset(Sponge, acrylic plate, 3D copper plate, sponge) was measured at 70.6 dB and MRI showed no artifacts. The same simulation of the material printed with a 3D copper PLA containing approximately 40 % copper powder resulted in no artifacts, therefore, the material output as a 3D printing was better suited for use. For MRI related research, the mutual development of 3D printing is highly anticipated.

Carbon Fiber as Material for Radiation Fixation on Device : A comparative study with acrylic (고정기구 재질로써 탄소 섬유와 아크릴의 방사선량 감쇄 영향 비교)

  • Chie, Eui-Kyu;Park, Jang-Pil;Huh, Soon-Nyung;Hong, Se-Mie;Park, Suk-Won;Kim, In-Ah;Wu, Hong-Gyun;Kim, Jae-Sung;Kang, Wee-Saing;Kim, Il-Han;Ha, Sung-Whan;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Radiation absorption parameters of carbon fiber panel were measured in comparison to acrylic panel. $30{\times}30cm$ sized 2mm thick carbon fiber panel and identical sized 6mm thick acrylic panel were placed in tray holder position and 0cm, 5cm, 10cm from surface of phantom. Radiation field size was $10{\times}10cm$. 50MU of 4MV photon was irradiated to the phantom with dose rate of 300MU/min. Source-to-phantom distance was 120cm. Radiation dose was measured with 0.6cc Farmer-type ionization chamber with 1cm build-up. Measurement was repeated thrice and normalization was done to the dose of the open field. Radiation transmission rate of carbon fiber panel is approximately 1% lower than acrylic panel of equivalent thickness. However, considering the strength of the material, transmission rate is higher for carbon fiber panel. Although carbon fiber panel increases the radiation dose when attached to the surface for about 2%, it normalizes the radiation dose to 97-99% of irradiated dose which could have been lowered to as much as 5-7.5% with acrylic panel. As carbon fiber panel is stronger than acrylic panel, radiation fixation device could be made thinner and thus lighter and furthermore, with increased radiation transmission. This in turn makes carbon fiber more ideal material for radiation fixation device over conventionally used acrylic.

Influence of Cortical Endplates on Ultrasonic Properties of Trabecular Bone (피질골판이 해면질골의 초음파 특성에 미치는 영향)

  • Kim, Yoon Mi;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • The present study investigated the influence of thick cortical endplates on the ultrasonic properties of trabecular bone in a femur with a high fracture risk. Twelve trabecular bone samples were prepared from bovine femurs, and acrylic plates with thicknesses of 1.25, 1.80, and 2.75 mm were manufactured to simulate the cortical endplates using acrylic with a density and a sound speed similar to cortical bone. Although the thickness of the acrylic plates attached to the two sides of the trabecular bone increased, high correlations were observed between the speed of sound and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.80-0.86. High correlations were also observed between the attenuation coefficient at 0.5 MHz and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.84-0.91. These results suggest that the speed of sound and attenuation coefficient at a specific frequency measured in a femur with relatively thick cortical endplates compared to the calcaneus could be used as indices for predicting the bone mineral density of the femur.

Dependencies of phase velocities of ultrasonic guided waves on cortical thickness in soft tissue-bone mimicking phantoms (연조직-골 모사 팬텀에서 피질골 두께에 대한 유도초음파 위상속도의 의존성)

  • Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.587-592
    • /
    • 2021
  • Change in the cortical thickness of long bones occurring with aging and osteoporosis is known to be a risk factor for fracture. The present study aims to investigate the dependencies of phase velocities of ultrasonic guided waves on the cortical thickness in 7 soft tissue-bone mimicking phantoms consisting of acrylic plates covered by a 2 mm-thick silicone rubber layer by using the axial transmission technique with a pair of transducers with a center frequency of 200 kHz and a diameter of 12.7 mm. Two distinct propagating waves with different velocities, the First Arriving Signal (FAS) and the Slow Guided Waved (SGW), were consistently observed for all the soft tissue-bone mimicking phantoms. The FAS velocity decreased slightly with increasing thickness, whereas the SGW velocity increased strongly with increasing thickness. The FAS and the SGW velocities were found to be closely consistent with the S0 and the A0 Lamb mode velocities for a free acrylic plate, respectively, suggesting that the presence of the soft tissue mimicking material (2 mm-thick silicone rubber layer) covering the acrylic plates does not influence significantly the velocity measurements.

Development of Vision system for Back Light Unit of Defect (백라이트 유닛의 결함 검사를 위한 비전 시스템 개발)

  • Cho, Sang-Hee;Han, Chang-Ho;Oh, Choon-Suk;Ryu, Young-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.127-129
    • /
    • 2005
  • 본 연구에서는 백라이트 유닛의 검사를 위한 머신비전 시스템을 구축한다. 시스템은 크게 하드웨어와 소프트웨어로 나눌 수 있고 하드웨어는 조명부, 영상획득부, 로봇 암 제어부로 분류된다. 조명부는 36W FPL램프로 구성되었고 조명부의 상판에 아크릴판을 거치대로 이용하여 백라이트 유닛을 거치한다. 로봇 암 제어부는 2축 로봇 암을 제어하여 로봇 암의 센서부착 지지대에 부착된 CCD 센서를 이동시킨다. 이와 동시에 영상획득부에서는 이미지를 획득하여 PC로 전송한다. 소프트웨어의 화상처리 검사 알고리즘은 일정 패턴이 있는 도광판에 대한 검사 알고리즘과 일정패턴이 없근 백라이트 유닛에 대한 검사 알고리즘으로 분리된다. 일정 패턴이 인쇄되어 있는 패널에 대한 검사 알고리즘은 모폴로지 연산을 이용하는 템플릿 체크방법과 블록 매칭 방법이 사용되었고 일정패턴이 없는 유닛에 대한 검사는 개선된 Otsu 방법을 이용하여 얼룩이나 흐릿한 결함에 대한 결함을 검출하였다. 실험결과 불균일한 결함과 밝기가 일정하지 않은 결함일지라고 90% 이상의 검출율로 뛰어난 성능을 입증하였다.

  • PDF

Fabrication and Evaluation of Piezoelectric Energy Harvesting Plate (자가발전 압전발판의 개발 및 평가)

  • Kim, Chang-Il;Kim, Chul-Min;Kim, Kyoung-Bum;Han, Woo-Seock;Jung, Young-Hun;Paik, Jong-Hoo;Lee, Young-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.156-156
    • /
    • 2009
  • 우리 주변에서 쉽게 얻을 수 있는 에너지를 수확하여 전기에너지로 변환해서 전자기기의 전원으로 사용하고자 하는 에너지 하비스팅의 연구가 활발히 진행중이다. 본 연구에서는 일정장소에 설치된 압전발판을 사람이 보행시 밟았을 때 압전체가 변형되어 전기에너지를 발생시키는 자가발전 압전발판을 제작하였다. 발생된 전기에너지를 육안으로 확인하기 위해 발판 주변에 LED를 설치하여 점등되도록 하였다. 최대의 전기에너지가 발생되도록 압전발판을 제작하고자 디스크형태의 압전체를 아크릴판에 휨이 발하는 지점에서 일정거리를 두어 부착하고 인위적으로 일정 변위가 발생하도록 가진을 하였을 때 발생하는 전압을 비교하였다. 또한 압전체에 동판이 부착된 형태로 동판 두께에 따른 발전특성도 비교하였다. 이를 바탕으로 최대의 발전특성을 나타내는 형태로 제작하여 다수의 압전소자를 밀집시키고 그 위에 판을 대어서 보행시 밟은 부분 외의 압전체에도 하중이 인가되도록 제작하였다. 인도, 도로, 교량 등에 압전발판을 다수 설치하여 전기에너지를 축적하여 센서등의 전원으로 응용성을 검증하였다.

  • PDF

Studies on the Focusing Solar Agricultural Crop Dryer - Part1. Heat Efficiency of Aluminum-laminated Aeryl Film Solar Heater - (농산물(農産物) 건조용(乾燥用) 곡면집광식(曲面集光式) 태양열(太陽熱) 이용(利用) 장치(裝置)에 관한 연구(硏究) - 제1보(第1報). 알루미늄-아크릴 필림을 이용(利用)한 태양열(太陽熱) 집열장치(集熱裝置)의 열이용(熱利用) 효율(?率) -)

  • Chun, Jae-Kun;Mok, Chul-Kyoon;Kim, Hyun-Uk
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.8-12
    • /
    • 1979
  • A cylindrical solar energy focusing collector constructed using aluminum-laminated film plastered on the acrylic plate and examined its performances under the Korean local weather conditions. The reflector surface of this collector· evidenced the reflectivity of 66.1%,which was satisfactory value that could be applicable to the solar collector for its low price and at·availability. Collector efficiency measured at the heat exchanger fluid in absorber-copper pipe black colored was 73% and the resulting natural convection of the heat transfer media (water) was recorded up to 2.82 cm/sec. The overall efficiency of the solar heater in operation was 28.6% and it was correlated with the solar energy input and the temperature elevation difference gained.

  • PDF

A Study on the Motion and Voice Recognition Smart Mirror Using Grove Gesture Sensor (그로브 제스처 센서를 활용한 모션 및 음성 인식 스마트 미러에 관한 연구)

  • Hui-Tae Choi;Chang-Hoon Go;Ji-Min Jeong;Ye-Seul Shin;Hyoung-Keun Park
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1313-1320
    • /
    • 2023
  • This paper presents the development of a smart mirror that allows control of its display through glove gestures and integrates voice recognition functionality. The hardware configuration of the smart mirror consists of an LCD monitor combined with an acrylic panel, onto which a semi-mirror film with a reflectance of 37% and transmittance of 36% is attached, enabling it to function as both a mirror and a display. The proposed smart mirror eliminates the need for users to physically touch the mirror or operate a keyboard, as it implements gesture control through glove gesture sensors. Additionally, it incorporates voice recognition capabilities and integrates Google Assistant to display results on the screen corresponding to voice commands issued by the user.

A Study on Incompletion of TIR within Acrylate of FTIR Touch Screen (FTIR 터치스크린 아크릴 계면의 전반사 현상 연구)

  • Han, Ji Heum;Han, Won Heum;Yoon, So Young
    • Journal of Adhesion and Interface
    • /
    • v.14 no.2
    • /
    • pp.57-67
    • /
    • 2013
  • The incompletion of TIR (Total Internal Reflection) in FTIR (Frustrated Total Internal Reflection) touch screen has been investigated as follows. Assuming a 3 layer thin film of medium1 ($n_1$)-medium2 ($n_2$)-medium3 ($n_3$) with refraction indices of $n_1=n_3{\neq}n_2$, it was theoretically proven that FTIR or OT (ordinary transmission) phenomena might happen through medium2 from medium1 to medium3 relying on relative difference in $n_1(=n_3)$ and $n_2$, and that the formulae for FTIR and OT could be transformed into each other depending on the number state (imaginary or real) of the light wave phase. In parallel to the theoretical analysis, the incompletion of TIR in acrylate due to external contacts was also elucidated from the experimental and phenomenological viewpoints. On the basis of this considerate work, we explained how to improve the touching performance for better FTIR touch screen.