• Title/Summary/Keyword: 아이스 슬러리

Search Result 62, Processing Time 0.033 seconds

Adhesion of Ice Slurry in a Multi-component Aqueous Solution with Stirring and Cooling (다성분계 수용액의 교반/냉각에 의한 빙부착)

  • 강채동;강용태;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1063-1070
    • /
    • 2002
  • To resist ice adhesion on cooling wall is concerned to continuous ice formation in thermal storage system. In this study, ice slurries were formed with two ecological aqueous solution, one is ethanol+silanol and the other is propylene glycol+silanol. By freezing under stirring the solution of $300m\ell$ in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, the shape of ice slurry and the strength of ice adhesion on wall was observed with measuring the temperature and stirring load variation. As the concentration is smaller and the supercooling degree is larger, the ice adhesion is easy to occur. When the stirring load is larger than$ 2.1\times10^{-5}W$, the ice adhesion occurred.

Flow pattern analysis and a study on formation of slurry ice in the reversing flow (역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구)

  • Oh, Cheol;Choi, Young-Gyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.202-202
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This study is experimented to observe flow pattern and formation of slurry ice in reversing flow to improve efficiency of heat transfer between fluid and freezing tube.

  • PDF

An experimental study on ice slurry fluid and pressure drop characteristics in along a horizontal circular tube around the valve (배관 내 밸브 주위의 아이스슬러리의 유동현상 및 압력강하특성에 관한 연구)

  • Oh, C.;Mun, S.B.;Son, Y.G.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.382-388
    • /
    • 2006
  • This study experimented to understand the effect of transporting ice slurry through in pipe with valve. And at this experiment it used ethylene glycol-water solution and a concentration is 30wt%. The experimental apparatus was constructed of ice slurry generation tank, turbo flow meter, manometers for differential pressure measuring, PIV system for flow pattern measuring. illumination and along a horizontal circular tube with valve as test section. The experiments were carried out under various conditions, with velocity of fluid at the entry ranging from 0.5 to 1.5 m/s and concentration of IPF is 30%. Also valve open rate is 50%, 75%, 100%.

Experimental Study on Flow Patterns and Pressure Drop Characteristics of Ice Slurry In Small Size Pipe (1) (소구경 배관내 아이스슬러리의 유동형상 및 압력강하 특성에 관한 실험적 연구(1))

  • 이동원;윤찬일;윤응상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.385-390
    • /
    • 2002
  • To clarify the hydraulic characteristics of ice slurry which made from 6.5% ethylene glycol-water solution flowing through circular pipes of small diameter, experimental studies were performed. The flow pattern was observed and the pressure drop was measured in acrylic pipes with inner diameter of 24 mm. The results of flow visualization revealed that ice particles flowed along the top of pipes in the ranges of small ice fraction and low flow rate, while Ice particles diffused into the whole region of pipes flowed like a homogeneous flow for high flow rate and high ice fraction. An increase in frictional pressure drop was measured as the ice fraction increased in all pipes and unstable flow was observed for up-ward vertical pipe.

Experimental Study on Flow Patterns and Pressure Drop Characteristics of Ice Slurry in Small Size Pipe (2) (소구경 배관내 아이스슬러리의 유동형상 및 압력강하 특성에 관한 실험적 연구(2))

  • 이동원;윤찬일;주문창
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.391-397
    • /
    • 2002
  • Pressure drop were experimentally investigated for ice slurry flowing in the acrylic pipes with inner diameter of 24 mm. Ice slurry was made from 6.5% ethylene glycol-water solution, and the pipes is consisted of horizontal, vertical (upward and downward) and $90^{\circ}$ elbow pipe. The ice Packing factor (IPF) and the flow rate of the experiments were varied from 0 to 30% and from 5 to 70kg/min respectively The measured pressure drop in various pipe positions were compared with those for the solution flow (IPF=0). The pressure drop was larder than that for solution flows as the IPF increased when the flow rate was low or very high. Sharp increases in pressure drop were observed for the cases when IPF is more than 70% in horizontal and vertical pipes, whereas the pressure drop increased with the IPF simultaneously in an elbow pipe.

Effect on the Adhesion of Ice Slurry by the Characteristic of Cooling Surface (냉각면 성상이 빙부착에 미치는 영향)

  • Seung Hyun;Hong Hi Ki;Kang Chae Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.183-190
    • /
    • 2005
  • In the process of ice-slurry making, ice adhesion on cooling wall or in narrow flow Path disturbs continuous ice formation. In this study, the effect on the ice adhesion to cooling surface by some freezing experiments was investigated, quantitatively. Three types of solutions were frozen in various coating vessels with stirring. In the experiment, the ice adhesion between cooling wall and Ice-slurry was evaluated by measuring stirring power. From the result, the stirring power of slurry mixture in PTFE-coating vessel was smaller than those in PE-coating, PFA-coating and bare SUS vessel. Especially, in EG H PG 1.S/ HD 1.5 mass$\%$ solution, the stirring power in the PE-coating vessel was smaller than that in the PFA-coating or SUS vessel.

Evaluation of Ice Adhesion in an Aqueous Solution with Functional Materials by Stirring Power (교반동력에 의한 기능성 물질 함유 수용액의 빙부착 평가)

  • Seung, Hyun;Baek, Jong-Hyun;Hong, Hee-Ki;Kang, Chae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.720-727
    • /
    • 2004
  • In the process of ice-slurry making, the phenomenon of ice adhesion influences extremely to ice making system. In this study, the effect on the ice adhesion by thermal storage material with additives is investigated quantitatively. Various solutions of 300 g in a stainless vessel were frozen under stirring. Through the experiment the ice adhesion between cooling wall and ice-slurry was compared with each other by measuring the stirring power. From the experiment, the stirring power in EG, SCA solution was smaller than those in the solution containing functional materials, such as poly-vinyl-alcohol or kitchen detergent.

A Study on the Heat Transfer Characteristics of Slurry Ice Generator using Scraper (스크레퍼형 슬러리아이스 제빙기의 열전달 특성 연구)

  • Kim, Joung-Ha;Yun, Jae-Ho;Kim, Min-Jun;Kim, Kyu-Jin;Cho, Hyoug-Seok;An, Seong-Kuk
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.144-149
    • /
    • 2006
  • In this study ice making characteristics are experimentally investigated for the ice slurry generating system which is pneumatically operated. The experimentations are conducted under the various test conditions such as chilled water inlet temperature, aqueous solution concentration, flow rate of cooling water, scraper pitch and frequency of cylinder stroke. For the above experimental conditions, ice making characteristics of the slurry ice generating system are evaluated in terms of the overall heat transfer coefficient, heat transfer rate and the amount of slurry ice generation. And the experimental results show that the heat transfer rate of the system increases as the flow rate of cooling water solution increases and the concentration of ethylene glycol and inlet temperature of chilled water decreases.

  • PDF

Measurement of the Ice Packing Factor of an Aqueous Solution Using the Index of Refraction (굴절률을 이용한 수용액의 빙충전율 측정)

  • Peck Jong-Hyeon;Chung Dong-Yeol;Kang Chaedong;Hong Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1088-1094
    • /
    • 2005
  • In the present paper, a new method is proposed for the measurement of the ice packing factor (IPF) of an ice slurry using the index of refraction. The purpose of the new method is to improve the resolution of the measurement and to increase its resistance to electric noise as compared to the standard IPF measurement technique that relies on measurement of the freezing temperature. These two methods are similar in that they both obtain a concentration of aqueous solution from measured physical quantities and calculate the IPF using a relation between concentration and IPF. We experimented and compared the two methods, whose results were also compared with results from the calorimeter method obtaining the IPF directly They are in good agreement (within $5\%$), which demonstrates the validity of the newly proposed method.

Effects of spray nozzles on the structure of twin spray (이중 분무의 중첩 구조에 미치는 분무 노즐의 영향)

  • Jurng, J.S.;Park, C.B.;Im, K.S.
    • Journal of ILASS-Korea
    • /
    • v.1 no.3
    • /
    • pp.51-59
    • /
    • 1996
  • An experiment was carried out on the structure of twin spray from pressurize-swirl nozzles, in order to investigate the effect of different size of spray nozzles on the characteristics of the overlap of two single sprays, for example, mean diameter, number density, and spatial distribution of flow rate. Using image processing method, the distributions of size and velocity of droplets of a single spray and twin spray were measured and compared to investigate the overlapping effect of two identical sprays. Comparing experimental results from a twin-spray with those from two-single sprays shows that the flow rate distribution of the twin-spray was concentrated around the midst of the overlapping region of two sprays. In this region, Sauter mean diameter (SMD) did not change much in the twin spray from 6032 nozzles, but it was smaller by 10 micrometers in the twin-spray than two-single sprays from 60063 nozzles. In spite of large difference in Weber numbers of the colliding sprays between the 60063 and 6032 nozzles, the phenomena did not have a big change in the overlapping region of twin spray. This shows that in the collision between droplets from two single spray in the overlapping region to cause the disruption of droplets, the size distribution of spray droplets was also important as well as Weber number.

  • PDF