• Title/Summary/Keyword: 쌍극자-쌍극자 탐사

Search Result 102, Processing Time 0.025 seconds

Electrical and VLF EM Responses for Conductive Dipping Dyke (맥상 황화광체에 대한 전기 및 전자탐사 반응)

  • Yoo In-Kol
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.110-115
    • /
    • 1998
  • Self-potential, VLF-EM and dipole-dipole resistivity methods have been widely used for exploration of conductive sulfide ore deposit, because of the convenience and low cost of field work and the reliability of their results. The geophysical responses for vein-type sulfide outcrop of Changkoom mine located in Bukwi-Myon, Jinan-Gun, Chollabuk-Do were investigated and compared with its drilling results. The geology around the survey area is composed of acidic volcanics and sediments of Yuchon Group. And sulfides bearing pyrite, pyrrotite, galena etc. are deposited in disseminated or vein type within acidic volcanics. Typical geophysical responses were detected from the above vein type ore body, respectively. From the shape and extent of S.P. anomaly, ore body is dipping westward and extending about 50 m. It is detected that the VLF EM response matching the outline of ore zone is considered as indication of dyke dipping westward. And also resistivity response indicating conductive dipping dyke is detected. From drilling results for outcrop and geophysical anomalies, the shape of ore body is vein type dipping about $70^{\circ}W$ and extending about 50 m.

  • PDF

통가 열수광상 지역의 해상 및 심해 지자기 조사 연구

  • Kim, Chang-Hwan
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.124-127
    • /
    • 2010
  • 본 연구에서는 통가 해역 라우분지의 열수 광상 가능성이 있는 해산들에 대하여 자력탐사가 수행되었다. 그 중 TA 09 해산에 대하여 심해견인 자력탐사가 실시되었으며 심해견인 자력탐사는 정밀한 탐사를 위하여 해저면에서 약 50 ~ 60 m 고도를 유지하며 자력계를 견인하였다. 탐사지역의 총 자력 성분은 Overhauser Proton Magnetomer (모델 SeaSPY 300(해상자력계)m, SeaSPY 6000(심해견인자력계))를 이용하여 측정되었다. 탐사 해산들 중 해상자력탐사와 심해자력탐사가 같이 수행된 TA 09 해산과 주요 열수 광상 유망 지역으로 분류되는 TA 12, 26 해산에 대해서만 측정된 지자기값을 이용하여 자기이상도를 구하였으며 자화역산법을 이용하여 자화이상도를 제작하고 분석하였다. TA 09 해산과 TA 26 해산에서의 해상 자기이상도는 쌍극자 이상형태의 단순이상을 보이며 TA 12 해산에서는 정상부에 고이상이 나타나고 그 주변으로는 저이상대가 분포하고 있다. TA 09 해산에서의 해상자력계에 의한 자기이상치와 심해견인자력계에 의한 자기이상치를 비교하여 보면 거의 10배 이상의 해상도 차이를 보여준다. 연구지역 탐사해산들의 해저지형과 비교하여 보면 열수분출대의 가능성이 높은 저자화이상대들은 주로 해산의 정상부 및 정상부 칼데라와 그 칼데라 주변부에 주로 위치하고 있는 모습을 나타내고 있다. 향후 타 탐사 해산들에 대한 자기이상에 대한 정밀처리/분석 후 탄성파 탐사결과, 암석샘플의 결과 및 지화학결과 등과 비교하여 열수광상의 존재 여부 및 위치 추정 분석이 필요할 것으로 판단된다.

  • PDF

Dipole-Dipole Array Geoelectric Survey for Gracture Zone Detection (전기비저항 탐사법을 이용한 지하 천부 파쇄대 조사)

  • Kim, Geon Yeong;Lee, Jeong Mo;Jang, Tae U
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.217-224
    • /
    • 1999
  • Although faults can be found by geological surveys, the surface traces of faults are not easily discovered by traditional geological surveys due to alluvia. In and around faults and fracture zones, the electrical resistivity appears to be lower than that of the surroundings due to the content of groundwater and clay minerals. Therefore, electrical resistivity surveys are effective to search buried faults and fracture zones. The dipole-dipole array electrical resistivity surveys, which could show the two dimensional subsurface electrical resistivity structure, were carried out in two areas, Yongdang-ri, Woongsang-eup, Yangsan-si, Kyungsangnam-do and Malbang-ri, Woedong-eup, Kyungju-si, Kyungsangpook-do. The one was next to the Dongrae Fault and the other near the Ulsan Fault was close to the region in which debatable quaternary fault traces had been found recently. From each measured data set, the electrical resistivity cross-section was obtained using the inversion program the reliability of which was analyzed using analytic solutions. A low resistivity zone was found in the inverted cross-section from the Yongdang-ri area survey data, and two low resistivity zones were found in that from the Malbang-ri area survey data. They were almost vertical and were 15∼20 m wide. Accounting the shape and the very low resistivity values of those zones (<100 Ωm)in the inverted section, they were interpreted as fracture zones although they should be proven by trenching. The reliability of the interpretation might be improved by adding some more parallel resistivity survey lines and interpreting the results in 3 and/or adding other geophysical survey.

  • PDF

Electric and Electromagnetic Surveys of the Hongseong Fault Zone (홍성 단층대에서의 전기, 전자 탐사 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Park, Gye-Soon;Oh, Seok-Hoon;Lee, Choon-Ki
    • Journal of the Korean earth science society
    • /
    • v.24 no.4
    • /
    • pp.361-368
    • /
    • 2003
  • We have investigated the electric resistivity structure of the fault zone located in the Hongseong area where a big earthquake with M 5.0 occurred in 1978. Usually, Electric and Electromagnetic methods are broadly operated in the field of engineering works since these methods are effective to understand the distribution of geological weak zones - fault or fracture zones. We have conducted the dipole-dipole array resistivity method and MT(magnetotelluric) method and interpreted the resistivity distribution of the fault zone with the aid of various inversion methods. An MT survey was performed at 18 points along a 2.9 km survey line perpendicular to the fault line and a magnetic dipole source was used to enhance the S/N ratio in the high frequency. A Electric dipole-dipole array resistivity survey with the dipole length of 50 meters was carried out perpendicular to the fault. In view of two survey results, the fault marks the boundary between two opposite resistivity structures, especially the low resistivity zone is exhibited deeply through the prospective fault line. The result that the low resistivity zone is located at the center of the fault zone corresponds with the fact that the fault zone of the Hongseong area is active. We expect these results to provide basic information about the physical properties of fault zones in Korea.

Subsurface Imaging by a Small-loop EM Survey (소형루프 전자탐사법에 의한 지하 영상화)

  • Lim Jin-Taik;Cho In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.4
    • /
    • pp.187-194
    • /
    • 2003
  • A small-loop electromagnetic (EM) system using multiple frequencies has advantages in survey speed and cost despite of limitation on its depth of investigation. Therefore, small-loop EM surveys have been frequently used on various site investigations involving engineering and environmental problems. We have developed a subsurface imaging technique using small loop EM data. We used a one-dimensional (ID) inversion method to reconstruct a subsurface image from frequency EM sounding data. Tests using simulated data show that the method can reasonably recover the subsurface resistivity structure. Also, the method was tested on field data obtained with multiple frequency small loop EM system at a farm in Chunchon, Korea. The resistivity image obtained form field data compares favorably with the image from the dipole-dipole resistivity survey.

Application of geophysical exploration for gold in the YongJang mine, Masan (마산 용장광산에서 금광에 대한 물리탐사의 적용)

  • Park, Jong-Oh;Song, Moo-Young;Park, Chung-Hwa;You, Young-June
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.213-219
    • /
    • 2006
  • The Yongjang mine is located in Masan City, Gyeongsangnamdo, which consists of a black shale possessing quartzite veins with othercompositions such as gold, silver, and sublimated sulfur. The average width of the veins is $9{\sim}17cm$ and the average degrees of the gold and silver are 3.6 g/t and 113.6 g/t respectively. A regional and a detailed scale electrical resistivity surveys are conducted to determine the existence of the mineralization zones and the linear structures in the study area. In addition, surveys of a several different array methods are conducted such as dipole-dipole array in the surface and borehole-to-surface array, surface-to-borehole array, and dipole-dipole array in the borehole. The method of element division can be applied to the region in which the borehole is curved, inclined or the distance between the electrodes is shorter than that of nodal points, because the coordinate of each electrode cannot be assigned directly to the nodal point if several electrodes are in an element. Yongjang vein is extended longer under the subsurface than on the surface in the images reconstructed from the 3D inversion. Therefore, it is recognized that the 3-D interpretation of the electrical resistivity survey is a very useful method to figure out the existence of strike and extension direction because the mineralization zones and the linear structures are shown in each depth.

  • PDF

Dipole-Dipole Resistivity Survey on the Side of Han River near Nanjido Landfill (난지도에 인접한 한강변에서의 쌍극자-쌍극자 전기탐사)

  • Lee, Kiehwa;Kwon, Byung-Doo;Oh, Seok-Hoon;Kim, Cha-Seop
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.335-343
    • /
    • 1996
  • The dipole-dipol electrical resistivity survey was conducted to investigate the probable contamination of the Han river by leachate from the near-by Nanjido Landfill. The survey line of 3 km was set along the unpaved road toward the Han river. For the convenience of the field work, the survey line was divided into four segments. The complete two-dimensional resistivity section was constructed by connecting the inversion result of each segment. Gravity survey was also carried out along the profile parallel to the resistivity line. Near surface resistivity generally appeared to be of very low value in most part of the survey area and the boundary between the alluvium layer and underlying basement rocks is well discriminated on the resistivity section. These results agree well with those of the preceding Schlumberger depth sounding made at adjacent area by Lee and fun (1995). The variation of thickness of the alluvium layer delineated by gravity anomaly profile also correlates well with the result of the resistivity survey on the qualitative basis. The problem of contamination by leachate from the Nanjido Landfill, where various waste materials have been dumped without any proper treatment facilities, has been remains unsolved yet. Therefore, we present the most probable passages of leachate flow based on the survey results and have briefly discussed about measure for contamination control. Considering the thickness of alluvium and the possible existence of fractured zone, the middle point between 1st and 2nd landfill and the midst of 1st landfill are the most hazardous regions to make leachates flow into the Han river. Since large amounts of leachates are observed from the test wells located on the lines extending from the border between the 1st and 2nd landfill and the middle of the lst landfill, contamination protection barriers are strongly recommended near these regions.

  • PDF

Electrical Resistivity-Measurements for the Detection of Fracture Zones in the Woraksan Granitic-Bodies (월악산화강암체의 파쇄대규명을 위한 전기비저항탐사)

  • 김지수;권일룡
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.113-126
    • /
    • 1997
  • Electrical resistivity methods of dipole - dipole array profiling and Schiumberger array sounding were tested on a segment of the Woraksan granitic batholith for the research into the imaging of irregular attitudes of fracture zones in the crystaaline rock in terms of processing and interpretation schemes. By the dipole - dipole array method, inhomogeneities such as small scale of fracture zones were properly delineated down at some depth even within hard rock environment. Fracture zones were interpreted to be at the boundaries between the high amplitude zone and very low amplitude zone in the resistivity plot and they were also successfully outlined in two - dimensional layer and pseudo - three - dimensional volume constructed by the incorporation of vertical sounding data. The surface location of the fracture zones was correlated by the zero - crossing point in the VLF(very low frequency) electromagnetic data. Pseudo - three - dimensional attitudes of fracture zones were efficiently illuminated by optimum projection angle. The mean of bulk resistivity for the Woraksan granite and the near fracture zones is estimated to be approximately of 4,000 ohm - m which is much higher than the value of 700 ohm - m for the Rwachunri limesilicate environment. This difference is due to both the rock type, i.e., biotite granite vs limesilicate, and the occurrence of secondary openings of fold and fault associated with the intrusion of granite. In this study statistical analyses on the resistivity color plot were performed in terms of three representative statistical moments, i.e., standard deviation, skewness, and kurtosis. The fracture zones in the standard deviation plot were characterized by the higher value, compared to the value of homogeneous portion. The upper boundary of the high resistivity zone was also successfully delineated in the skewness and kurtosis plots.

  • PDF

Surface geophysical surveys the northern part of the Yongdong basin (Cretaceous), Korea (영동분지(백악기) 북부 지역에 대한 지표물리탐사)

  • Kim, Ji-Su;Han, Soo-Hyung;Rhee, Cheol-U;Kim, Bok-Cheol;Ryang, U-Heon
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.4
    • /
    • pp.329-336
    • /
    • 2002
  • Electrical resistivity dipole-dipole, seismic refraction, and seismic reflection methods were performed to delineate the boundaries the Yongdong basin(Cretaceous) in terms of physical properties and to ultimately identify the margin architectures of the faults or unconformities. Higer resistivities (approximately >2000 ohm-m) most likely originate from the basement of the basin, contrasting with the lower resistivities from infilled sedimentary rocks. Faults at the eastern margin and unconformities at the western boundary are characterized as high-slope($70^{\circ}$) and gentle-slope($30^{\circ}$) gradients in the resistivity sections, respectively Such features for the boundaries are also suggested by the lower values of seismic velocity and resistivity for the western margin.

  • PDF

Electrical Surveys at the Seokdae Waste Landfill of Pusan (부산 석대 폐기물 매립지에서의 전기탐사)

  • Kiehwa Lee;Jong-Ryeol Yoon
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.4
    • /
    • pp.185-190
    • /
    • 1997
  • Electrical surveys were conducted at the Seokdae waste landfill in July,1996. Within the landfill, 4 lines of dipole-dipole surveys and 7 Schlumberger soundings were carried out and 2 soundings in front of the landfill. In the landfill, interpretations of the survey data show low resistivity zones below 10 Ωm to a depth of 50 m from the surface and such low resistivity zones of the D block are thicker than those of the other blocks by about 2~10 m. Considering the depth of the bedrock and the height of waste reclamation, no evidence of bedrock contamination by leachate is indicated. But it is inferred that the weathered zones are contaminated in the landfill. In the block A and B, minor fault having the strike of N$70^{\circ}$W have been confirmed by dipole-dipole surveys, so future contamination of the bedrock by leachate is possible The degree of ground contamination is the highest in the D block due to the leachate plume mainly heading for this block. On the other hand, electrical soundings do not indicate ground contamination by leachate in the front area of the landfill.

  • PDF