• Title/Summary/Keyword: 쌍계사

Search Result 16, Processing Time 0.019 seconds

Quantitative Analysis on Intensity of 1936 Jirisan Earthquake by Estimating Seismic Response Characteristics at the Site of Five-story Stone Pagoda in Ssang-gye-sa (쌍계사 오층 석탑 부지의 지진 응답 특성 평가를 통한 1936년 지리산 지진 세기의 정량적 분석)

  • Sun, Chang-Guk;Chung, Choong-Ki;Kim, Jae-Kwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3C
    • /
    • pp.187-196
    • /
    • 2008
  • An earthquake of magnitude 5.0 occurred at Ssang-gye-sa, a Buddhist temple in Jirisan, located near the southern border of the Korean peninsula on 4 July 1936. It resulted in severe damage of several buildings and structures in Ssang-gye-sa. Particularly, the top component of a five-story stone pagoda in the temple was tipped over and fell down during the earthquake. This earthquake damage case would be usefully applied to estimating the intensity of ground motion in the Korean peninsula, a moderate seismicity region, where strong motion has never been recorded with the exception of historic seismic events. In order to estimate the local site effects and the corresponding ground motion at Ssang-gye-sa site, intensive site investigations including borehole drilling and in-situ seismic tests such as crosshole and SASW tests were performed in the temple area. Based on the site characteristics, site-specific seismic response analyses using various input motions were conducted for a representative Ssang-gye-sa site by means of both one-dimensional equivalent-linear and nonlinear methods with six input rock outcrop acceleration levels ranging from 0.044g to 0.220g. The resultant site-specific seismic responses indicated the amplified ground motions in the short-period range near the site period of Ssang-gye-sa. Furthermore, the intensity on rock outcrop of the 1936 Jirisan earthquake was estimated by making a comparison between the site responses analysis results in this study and the full-scaled seismic test of pagoda model in the prior study.

Pigment Analysis for Wall Paintings According to Verification of Penetration Depth for X-ray: Ssanggyesa Daeungjeon (Main Hall of Ssanggyesa Temple) in Nonsan (X-선 투과깊이 검증에 따른 벽화 안료의 정밀분석: 논산 쌍계사 대웅전)

  • Chun, Yu-Gun;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.269-276
    • /
    • 2011
  • We have suggested effective P-XRF analysis method for pigment painting layer by calculating penetration depth of X-ray. This experiment calculated that X-ray generated from P-XRF was possible penetration until 1.17mm deep in the pigment painting. Based on the experimental results, analysis for eight color pigments on wall paintings in Ssanggyesa Main Hall, most pigments were painted traditional pigments. However pigments on recently restorated wall painting were used synthetic modern pigments.

A Study on the engraving place of wood printing plates in the Haeinse (해인사 소장책판의 판각처에 관한 연구)

  • ;Kim, Young-Son
    • Journal of Korean Library and Information Science Society
    • /
    • v.28
    • /
    • pp.415-445
    • /
    • 1998
  • This study attempts at the engraving place of wood-printing plates held in the Haein Temple(해인사), which were famous for playing the significant role in the understanding of publishing activities of both the Koryo and Choson Dynasty. Following the common way the bibliographic elements of the books were analyzed namely according to the publication place and the publisher. The findings derived from the analysis are summarized as follows; In the Haeinsa the wood-printing plates books are preserved moved from 17 temples such as Bongso-Sa(봉서사), Hago-Sa(하고사), Soksuam(석수암), Inhung-Sa(인흥사), Wonkwang-Sa(월광사), Sinha-Sa(신하사), Gunsyaeng-Sa(군생사), Jangsu-Sa(장수사), Yongtong-Sa(영통사), Wonjok-Sa(원적사), Unjin(은진) SSanggye-Sa(쌍계사), Songsan(성산) SSanggye-Sa(쌍계사), Hungyul-Sa(흥률사), Jongwon-Sa(정원사), Yon-Sa(연사), Gamro-Sa(감로사), Yongguam(영귀암) besides the publications of temples, there are publications of local branches of gangyengdogam(간경도감) such as Jinju(진주), Sangju(진주), Sangju(상주), Andong(안동), of local public agencies such as Gaelimbu(계림부), Dalsunggwan(달성관), and of private families of which 8 titles in the Koryo Dynasty and 13 titles of the Choson Dynasty. Among the "SSanggyae-Sa(쌍계사) publication" held in the Haeinsa, 9 titles including Chimungyonghun(치문경훈) are recklesaly preserved with dividing both in Gap temple(갑사) and in Haeinsa as the same publication. It is possible that other scattered present publications or remaining publications might have been remaining publication from those partly burnt ones of the complete publications. By means of the investigation on the catalogs of publications, 5 titles such as <> <> <> <> <> which are now kept in the Haeinsa moved from the Taegubu(대구부) or Yongyon-Sa(용연사) were newly identified.

  • PDF

Dynamic Test of a Full Scale Model of Five-Story Stone Pagoda of Sang-Gye-Sa (쌍계사 오층석탑 실물 크기 모델의 동적 거동 시험)

  • Kim, Jae-Kwan;Ryu, Hyeuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.51-66
    • /
    • 2001
  • There occurred a moderate size earthquake of Magnitude 5 in Whagae-Myun, Hadong-GUn, Kyongsangnam-Do on July 4, 1936. It caused severe damage to the buildings and other structures in Sang-Gye-Sa, a Buddhist Temple. The top component of a five-story stone pagoda was tipped over and fell down to the ground during the earthquake. In order to have accurate and quantitative estimate of the peak acceleration level of that earthquake, a full-scale model was constructed through rigorous verification process. The complete model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low acceleration level. In the fragility test, the behavior of the model was carefully monitored while increasing the acceleration level. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

시원한 국물, 여행의 피로 말끔히 씻어줘 하동 재첩국

  • KOREA ASSOCIATION OF HEALTH PROMOTION
    • 건강소식
    • /
    • v.29 no.2 s.315
    • /
    • pp.36-37
    • /
    • 2005
  • 섬진강을 사이에 두고 전남 구례와 마주보고 있는 하동은 에로부터 수려한 자연경관이 빼어난 곳으로 잘 알려져 있다. 맑고 깨끗한 물에서 서식하는 재첩을 비롯해 차밭, 화개장터, 쌍계사에 이르기까지 다양한 볼거리가 많은 곳으로도 유명하다.

  • PDF

Study on the Characteristics of Materials and Manufacturing Techniques for the Mural Paintings in Daeunjeon at Ssanggyesa Temple, Jindo (진도 쌍계사 대웅전 벽화의 재질특성 및 제작기법 연구)

  • Lee, Na Ra;Yu, Yeong Gyeong;Lee, Hwa Soo
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.701-711
    • /
    • 2021
  • This study identifies the structure and material characteristics of the mural paintings in Daeungjeon at Ssanggyesa temple in Jindo by conducting scientific research and analysis including microscope examination, SEM-EDS, XRD, particle size analysis, and others. According to the analyses, the murals were considered to be of a typical soil mural style for Korean Buddhist murals, given that the walls were made of sand and soil and the murals had layers consisting of wall layers and a finishing layer. However, some finishing layer used calcite, while some ground layer used zinc white beneath the thick paint. In addition, there were similar features to those found on the surfaces of oil paintings such as cracks along with the paint layer, high gloss on surfaces, and thick brush strokes in many areas. It was found that the walls on which the murals were painted were made of soil but that the paint layer was created based on the oil painting technique using drying oil. It determined that the murals were painted in a unique painting style that is rarely found in other typical Buddhist murals in Korea.

Shaking Table Test of the Model of Five-story Stone Pagoda of Sang-Gye-Sa Mounted on Base Isolation Systems (쌍계사 오층석탑모델에 대한 지진격리효과 진동대실험)

  • 김재관;이원주;김영중;김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.331-338
    • /
    • 2001
  • Seismic performances of the base isolated model of Five Story Stone Pagoda were studied through shaking table tests. Friction pendulum system (FPS), Pure-friction system with laminated rubber bearing (LRB) and Ball with rubber bearing were selected fur the comparison of performances. Performances of specially designed isolation systems were tested dynamically using shaking table. The test results of isolated model are compared with those of fixed base model. Compared with fixed base model, the isolated model showed that it could withstand much higer intensity of earthquake motion. The Effective Peak Ground Acceleration (EPGA) value of isolated model when the top component tipped over was above twice of that value in case of fixed base model. According to the additional test results, the lower value of coefficient of friction than that of common frictional base isolation systems is more effective to protect the piled multi-block system of Pagoda against moderate intesity of ground motion.

  • PDF

Seismic Test of a Full Scale Model of Five-Story Stone Pagoda of Sang-Gye-Sa (쌍계사 오층석탐 실물 크기 모델의 지진시험)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.388-395
    • /
    • 1999
  • There occurred a moderate size earthquake of M=5 at Whagae-Myun Hadong-Gun Kyongsangnam-Do of Korea, It caused severe damage to the buildings and other structures is Sang-Gye-Sa a famous and beautiful Buddhist Temple, The 5-story stone pagoda was standing in front of Keumdang. The top component tipped over and fell to the ground during the earthquake. In order to have accurate and quantitative estimate of the intensity of earthquake a full-scale replica is made through rigorous verification process, The completed model was mounted on the shaking table and subjected to th seismic tests. It was observed that the top component overturned at 0.16 G of EPGA when the NS component of the 1940 el Centro earthquake records was used as the input motion. A brief history of this project is presented and important test results are report6ed and their implication is discussed.

  • PDF