Journal of the Institute of Electronics Engineers of Korea CI
/
v.49
no.1
/
pp.1-7
/
2012
In general, currently developed ECG(electrocardiogram) based biometrics approaches are not suitable for real market applications since they require high cost ECG monitoring device and their measurement methods showed poor usability. In this paper, we developed lead I signal based biometrics system using special purpose ECG measurement hardware. To guarantee signal quality for biometrics from various signal measurement environment in our ordinary life, several filters are applied. In addition, to enhance usability, only two skin on electrodes without reference point are used for measurement. Lead I signals of seventeen candidates are measured from developed hardware and features are extracted. Extracted features are applied to support vector machine (SVM) pattern classifier for biometrics, and the experimental results showed 98.59% of sensitivity (SN) and 97.21% of accuracy (ACC). Compare to conventional ECG biometrics approaches, proposed system showed enhanced usability with low-cost measurement hardware.
Proceedings of the Korean Society for Emotion and Sensibility Conference
/
2009.11a
/
pp.202-205
/
2009
체력이나 건강을 위한 트레이닝이나 심장 질환자의 생체신호 모니터링을 위해 다양하게 사용되는 심전도는 현재 여러가지 장비형태로 사용되고 있다. 최근에는 착용자가 인식하지 않고 손쉽고 편안한 방법으로 측정하거나 모니터링 할 수 있는 형태의 생체신호 모니터링 의복에 관한 연구가 많이 진행되고 있다. 본 연구에서는 20대 남성의 체표면 분석을 통해 심전도 검출이 가능한 일체형 의복을 설계하고 제작된 시제품의 착의평가를 진행하였다. 심전도 측정이 가장 효과적인 흉부 부분을 중심으로 심전도 데이터 추출 정확성을 위해 다층구조로 센서를 설계하고, 흉부의 움직임을 최소화하여 노이즈를 감소할 수 있는 디자인을 제안한 결과, 심전도 데이터 추출 정확성 및 편의성은 향상되고 노이즈는 감소하는 결과를 도출하였다.
In this paper, an ECG-NIBP patient monitor is designed. This is an essential equipment to measure and monitor patient's physical condition - electrocardiogram(ECG) wave, heart rate(HR), and noninvasive blood pressure(NIBP) - in ICU, CCU, and operating room. The ECG is an electrical waveform produced by relaxation and contraction of the cardiac muscle. Most physicians diagnose patient's cardiac states from ECG pattern. A blood pressure is one of the clinical indexes measured in a emergency room or operating room. In this paper, the blood pressure is measured in artery by using the nonivasive oscillometric method. The developed patient monitor was inspected and compared with other instruments in operating rooms. The results were 1bpm of maximum difference in the heart rate, 15mmHg in the systolic pressure, 16mmHg in the diastolic pressure, and 25mmHg in the mean blood pressure. But the total results were 0.15bpm of the mean difference in the heart rate, 5mmHg in the systolic pressure, 10mmHg in the diastolic pressure, and 9mmHg in the mean blood pressure. The designed ECG-NIBP patient monitor can measure the ECG wave, HR, and BP. And the multi-tasking module of pulse oximetry . respiration . temperature monitor will be added in the near future.
초고속 인터넷과 무선 전송 등 통신기술이 급속히 발전되면서 보다 간편하게 건강 상태를 검진할 수 있는 방법에 대한 연구가 많이 진행되고 있다. 건강상태를 지속적으로 확인하기 위해서는 생체 신호 측정 장비의 높은 휴대성과 편리성, 정확한 측정이 가능해야 한다. 본 연구에서는 정확한 측정과 높은 휴대성을 위하여, 생체 신호 측정 장비를 소형화 및 저전력화를 실현하였고, 활동성을 위해 근거리 무선 통신 방식인 Bluetooth를 사용하였다. 개발된 유비쿼터스 무선 ECG 시스템은 일상적인 심전도 측정이 가능하여 협심증, 심근경색, 부정맥 등 심장질환의 조기 진단에 유용하게 사용 될 것이 기대된다.
Kim Jin-Sang;Choi Sang-Yeol;Bae In-Ho;Kim Yun-Nyeon
Proceedings of the Korean Institute of Intelligent Systems Conference
/
2006.05a
/
pp.269-272
/
2006
병원의 각종 측정 장비에서 출력되는 결과지나 의사들이 작성한 기록지를 스캔하여 이미지형태로 저장하는 이미징 시스템 개발이 크게 요구되고 있다. 본 논문에서는 신경망과 그래픽 기법을 사용하여 대학병원 심전도실에서 사용되는 여섯 종류의 심전도 출력지를 이미지 형태로 저장하고 검색하는 이미징 시스템의 설계와 구현에 대해 논하였다. 구현된 시스템은 여섯 종류의 심전도 출력지를 분류하고, 분류된 각 출력지에 인쇄된 중요한 측정 데이터를 인식하여 데이터베이스에 저장한다. 심전도 출력지의 분류는 각 샘플 서식들의 평균 히스토그램을 구한 다음 새로운 출력지가 들어올 때 평균 히스토그램과의 거리가 가장 가까운 출력지로 분류하는 nearest-neighbor 방법을 사용하였다. 출력지에 인쇄된 데이터의 인식을 위해 먼저 XML로 작성한 출력지별 추출 정보를 기반으로 스캔한 이미지의 영역 분할 작업을 수행한다. 분할된 영역들은 신경망을 이용해 문자 인식을 하고, 인식된 문자들이 데이터베이스의 해당 속성값으로 저장된다. 스캔한 출력지는 의사들이 주석을 붙이거나 조건 검색을 위해 이미지 형태로 저장된다.
Journal of the Korea Academia-Industrial cooperation Society
/
v.14
no.4
/
pp.1903-1907
/
2013
Heart condition should be observed for long periods of time because it does not appear abnormal all the time. However, there are many difficulties checking our health for a long time due to its size, operation of equipment, and cost. To solve these problems, an electrocardiograms(ECG), specially interfacing three gel-less metal electrodes for low cost portable applications, is designed and implemented. Gel-less metal electrodes are used for ECG monitoring system instead of gel-type electrodes that can cause skin rashes and itching problem. The whole ECG system consists of two parts-analog and digital circuits. The analog measurement circuit that has a 18*25mm size is made up of op-amps maintaining a sufficiently high common-mode noise rejection and passive elements of SMD type. Analog heart signal is converted to digital stream suitable for display on a TFT-LCD by an 8-bit microcontroller. The size of the completed ECG system is 25*80*50mm and its weighing is about 150g, which is small enough to be easily used. Therefore, the implemented ECG system can be used as a portable one.
Proceedings of the Safety Management and Science Conference
/
2013.11a
/
pp.561-567
/
2013
본 연구는 졸음운전의 지표로 예상되는 심전도의 LF/HF 비율이 효과적으로 졸음운전을 예측하는지를 검증하는 것이었다. 본 연구는 총 31명이 참가하였으며, 가상 운전 시뮬레이션 과제를 활용하여 진행하였다. 수면박탈이 운전 중 LF/HF 비율에 영향을 미치는지를 검증하기 위해 충분한 수면을 취한 조건과 수면이 박탈된 조건으로 실험을 실시하였다. 충분한 수면을 취한 조건에서 참가자는 전날 6시간 이상의 수면을 취한 후 30분동안 진행되는 가상 운전과제를 수행하였다. 수면이 박탈된 조건에서는 실험에 참여하기 전날에 참가자가 5시간 이하의 수면을 취하도록 유도한 후 60분 동안 진행되는 가상 운전 과제에 참여하도록 하였다. 참가자는 두 조건 모두에서 심전도를 측정할 수 있는 장비를 착용한 상태로 가상 운전 과제를 수행하였다. LF/HF 비율과 지각된 졸음운전과의 관계성을 확인하기 위해서 참가자가 가상 운전 과제를 수행하는 동안 10분간격으로 주관적 졸림정도를 측정하였다. 실험 결과 충분한 수면을 취한 조건보다 수면박탈 조건에서 참가자의 LF/HF 비율이 감소하였으며, 동일하게 주관적 졸림정도는 증가하였다. 또한 주관적 졸림정도가 LF/HF비율을 예측하는 것으로 나타났다. 따라서 LF/HF 비율을 통한 졸음 운전 예측은 타당한 것으로 나타났다.
Transactions of the Korean Society of Mechanical Engineers B
/
v.35
no.7
/
pp.685-691
/
2011
The aim of this study is to point out the uniqueness of Doppler optical coherence tomography (DOCT) for use in a probe station for (in vivo) visualization of microscale flow and structure and to maximize the effectiveness of DOCT by overcoming its limitations. Conventional DOCT produces images of only one of the velocity components that is parallel to the incident light. In this study, a multi-angle DOCT to quantify a velocity vector field is proposed; this is an extension from a velocity scalar field to a vector field. Quantifying an instantaneous three-dimensional velocity field in a pulsating flow is another challenge because of its limited frame rate. The in-vivo pulsating blood flow is measured by using an electrocardiogram-gated multi-angle DOCT in a hamster cheek pouch model. It is shown that the aliasing problem caused by a relatively low frame rate is resolved by using this method of measurement.
The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).
The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.