• Title/Summary/Keyword: 심장CT

Search Result 415, Processing Time 0.036 seconds

Rapid Development of Diffuse Myocardial Calcification in a Patient after Recovery from Sepsis and Renal Failure: A Case Report (패혈증과 신부전에서 회복된 환자에서 급속하게 발생한 미만성 심근 석회화: 증례 보고)

  • Mi Hyun Kang;Song Soo Kim;Byung Joo Sun;Jae-Hyeong Park
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1104-1108
    • /
    • 2022
  • Myocardial calcification can develop owing to several conditions. It is a rare complication following sepsis and renal failure. We report a case of rapid development of left ventricular mid-wall calcification observed using CT and cardiac MRI in a patient after recovery from sepsis and acute renal failure.

A Rare Case of Cardiac Neurofibroma in a Patient with Neurofibromatosis Type 1: Radiologic Findings (신경섬유종증 1형 환자에서 드물게 발생하는 심장 신경섬유종: 영상의학적 소견)

  • Sanghyun Seo;Ji Young Rho
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1321-1327
    • /
    • 2021
  • Neurofibromatosis type 1 (NF1) is a relatively common inherited disorder characterized by the formation of neurofibromas, pigmentary abnormalities of the skin, Lisch nodules of the iris, and skeletal abnormalities. Multiple cutaneous neurofibromas are benign nerve sheath tumors and the main manifestation of NF1. Cardiac neurofibroma associated with NF1 is very rare, and few cases have been reported in the literature. Herein, we present the CT and MRI findings of a surgically confirmed left ventricular neurofibroma in a 32-year-old female with NF1.

Dose Comparison Using Deformed Image Registration Method on Breast Cancer Radiotherapy (유방암 방사선치료에서 변형영상정합기법을 이용한 선량비교)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • The purpose of this study is to reconstruct the treatment plan by applying CBCT and DIR to dose changes according to the change of the patient's motion and breast shape in the large breast cancer patients and to compare the doses using TWF, FIF and IMRT. CT and CBCT were performed with MIM6 to create DIRCT and each treatment plan was made. The patient underwent computed tomography simulation in both prone and supine position. The homogeneity index (HI), conformity index (CI), coverage index (CVI) to the left breast as planning target volume (PTV) were determined and the doses to the lung, heart, and right breast as organ at risk (OAR) were compared by using dose-volume histogram and the unique property of each organ. The value of HI of the PTV breast increased in all treatment planning methods using DIRCT, and CVI and CI were decreased in the treatment planning methods using DIRCT.

Animal Diagnosis System Using Wireless Digital Stethoscope (무선 디지털청진기를 이용한 동물 진단시스템)

  • Park, Kee-Young;Hong, Soo-Mi;Lee, Jong-Ha;Park, Jin-Ho;Jung, Eui-Bung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.722-727
    • /
    • 2013
  • Medical treatment for animals is very difficult as the opinions of pets' masters take priority over treatment regardless of the seriousness of pets' disease or the needs of medical treatment. In case that a pet has heart disease, especially, it is difficult to get the direct answer from the pet's master on the decision or confirmation of treatment. For those reasons, it is almost impossible to predict and treat the pet before an emergency like the heart failure or an unexpected death happens. Using stethoscope can be the first diagnosis method to check the heart or any kinds of disease inside the body. High-tech equipments like CT, X-ray or Ultrasound can be used, but they can only be used as a second choice of diagnosis method since it requires professional skills and its high price. That's why stethoscope is still the best diagnostic tool when one makes the first diagnosis. In this study, we give a detailed account of digital diagnosis system in which veterinarians can analyze the sound from stethoscope without bringing it to their ears and make a diagnosis wherever they are. And we suggest a new concept of diagnosis system surrounding, which shows the relativeness of disease through Level Crossing Rate(LCR) and energy level from the stethoscope sound made in this system.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Optimization of the Empirical Method to the Enhancement Image of the Four Chambers at the Same Time in the Pediatric Cardiac Computed Tomography (소아 심장 전산화단층촬영 검사에서 4 chamber의 동시 조영증강 영상에 대한 최적화 방안)

  • Park, Chanhyuk;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.279-285
    • /
    • 2014
  • This study is to have dose reduction and minimization of excessive use of contrast medium in the pediatric cardiac computed tomography and to suggest the optimization plan to acquire the enhancement image of the 4 chambers at the same time by formulating scan delay time in empirical method with considering variables such as contrast medium injection velocity and cardiac approaching time. Quantitative, qualitative and dose assessment were carried out for 30 pediatric patients who had taken the cardiac examination. In conclusion, image enhancement in 4 chambers of the cardiac shows over 300 HU which is proper to pediatric cardiac reading by applying the empirical method with calculating scan delay time according to weight and contrast medium volume and injection velocity. Qualitative image assessments in confidence sharpness and noise have excellence qualitatively. Exposure dose to pediatrics also decreases precisely. Therefore this study is judged to take a important role of making optimization images with advantages of dose reduction and less side effects caused by it's excessive use in clinic.

Early Detection of the Acute Exacerbation of Interstitial Pneumonia after the Surgical Resection of Lung Cancer by Planned Chest Computed Tomography

  • Oyama, Kunihiro;Kanzaki, Masato;Kondo, Mitsuko;Maeda, Hideyuki;Sakamoto, Kei;Isaka, Tamami;Tamaoki, Jun;Onuki, Takamasa
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.177-183
    • /
    • 2017
  • Background: To improve postoperative outcomes associated with interstitial pneumonia (IP) in patients with lung cancer, the management of the postoperative acute exacerbation of IP (PAEIP) was investigated. Methods: Patients with primary lung cancer were considered to be at risk for PAEIP (possible PAEIP) based on a preoperative evaluation. The early phase of this study was from January 2001 to December 2008, and the late phase was from January 2009 to December 2014. In the early phase, chest computed tomography (CT) was performed for patients for whom PAEIP was suspected based on their symptoms, whereas in the late phase, chest CT was routinely performed within a few days postoperatively. The numbers of possible PAEIP cases, actual PAEIP cases, and deaths within 90 days due to PAEIP were compared between both phases. Results: In the early and late phases, surgery was performed in 712 and 617 patients, 31 and 72 possible PAEIP cases were observed, nine and 12 actual PAEIP cases occurred, and the mean interval from the detection of PAEIP to starting treatment was $7.3{\pm}2.3$ and $5.0{\pm}1.8$ days, respectively. Five patients died in the early phase, and one patient died in the late phase. Significantly fewer PAEIP-related deaths were observed in the late phase (p<0.05). Conclusion: Identifying patients at risk for PAEIP by routine postoperative CT examinations led to the early diagnosis and treatment of PAEIP, resulting in the reduction of PAEIP-related mortality.

Change of Proximal Descending Aortic False Lumen after Conventional Repair of Acute Type I Dissection: Is It Always Unfavorable?

  • Kim, Sue Hyun;Kim, Jun Sung;Shin, Yoon Cheol;Kim, Dong Jung;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.48 no.4
    • /
    • pp.238-245
    • /
    • 2015
  • Background: Some patients show favorable changes in the descending aortic false lumen after conventional repair of acute type A dissection, although the incidence of favorable changes has been reported to be low. We aimed to investigate the incidence of positive postoperative changes in the false lumen and the factors associated with positive outcomes. Methods: In 63 patients who underwent surgery for type A acute dissection as well as serial computed tomography (CT) scanning, morphological parameters were compared between the preoperative, early postoperative (mean interval, 5.4 days), and late CT scans (mean interval, 31.0 months) at three levels of the descending thoracic aorta. Results: In the early postoperative CT images, complete false lumen thrombosis and/or true lumen expansion at the proximal descending aorta was observed in 46% of the patients. In the late images, complete thrombosis or resolution of the proximal descending false lumen occurred in 42.9% of the patients. Multivariate analysis found that juxta-anastomotic false lumen thrombosis was predictive of favorable early changes, which were in turn predictive of continuing later improvement. Conclusion: Even after conventional repair without inserting a frozen elephant trunk, the proximal descending aortic false lumen showed positive remodeling in a substantial number of patients. We believe that the long-term prognosis of type A dissection can be improved by refining surgical technique, and particularly by avoiding large intimal tears at the anastomosis site during the initial repair.

Long-Term Changes in the Distal Aorta after Aortic Arch Replacement in Acute DeBakey Type I Aortic Dissection

  • Cho, Kwangjo;Jeong, Jeahwa;Park, Jongyoon;Yun, Sungsil;Woo, Jongsu
    • Journal of Chest Surgery
    • /
    • v.49 no.4
    • /
    • pp.264-272
    • /
    • 2016
  • Background: We analyzed the long-term results of ascending aortic replacement and arch aortic replacement in acute DeBakey type I aortic dissections to measure the differences in the distal aortic changes with extension of the aortic replacement. Methods: We reviewed 142 cases of acute DeBakey type I aortic dissections (1996-2015). Seventy percent of the cases were ascending aortic replacements, and 3 0% of the cases underwent total arch aortic replacement, which includes the aorta from the root to the beginning of the descending aorta with the 3 arch branches. Fourteen percent (20 cases) resulted in surgical mortality and 86% of cases that survived had a mean follow-up period of $6.6{\pm}4.6years$. Among these cases, 64% of the patients were followed up with computed tomography (CT) angiograms with the duration of the final CT check period of $4.9{\pm}2.9years$. Results: There were 15 cases of reoperation in 13 patients. Of these 15 cases, 13 cases were in the ascending aortic replacement group and 2 cases were in the total arch aortic replacement group. Late mortality occurred in 13 cases; 10 cases were in the ascending aortic replacement group and 3 cases were in the total arch aortic replacement group. Eight patients died of a distal aortic problem in the ascending aortic replacement group, and 1 patient died of distal aortic rupture in the total arch aortic replacement group. The follow-up CT angiogram showed that 69.8% of the ascending aortic replacement group and 35.7% of the total arch aortic replacement group developed distal aortic dilatation (p=0.0022). Conclusion: The total arch aortic replacement procedure developed fewer distal remnant aortic problems from dilatation than the ascending aortic replacement procedure in acute type I aortic dissections.