• Title/Summary/Keyword: 심장조영술

Search Result 141, Processing Time 0.029 seconds

Angiographic Results of Radial Artery Grafts that are Used for Myocardial Revascularization (관상동맥 우회술 후 혈관조영술을 이용한 요골동맥의 개통률 분석)

  • Yie, Kil-Soo;Oh, Sam-Sae;Kim, Jae-Hyun;Shinn, Sung-Ho;Kim, Soo-Cheol;Seo, Hong-Joo;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.8
    • /
    • pp.546-551
    • /
    • 2007
  • Background: The radial artery is gaining widespread acceptance as complementary arterial conduits for surgical myocardial revascularization, but there have been limited reports about its angiographic patency compared with that of internal thoracic artery or saphenous vein. We tried to evaluate angiographic patency of radial artery graft and to compare that of radial artery and other gratis with retrospective manner. Material and Method: From January 2001 to Jure 2006, totally 132 patients (male 92, female 40) who underwent coronary artery bypass graft using radial artery were re-admitted to our hospital for follow up angiographic examination. Mean age was 58.2+8.87 and mean follow up duration was 32 month ($2{\sim}110$ month). Off pump and on pump bypass surgery were performed 74 and 58 patients respectively. Along with radial artery, left internal thoracic arteries were used in 57 cases, concomitant left internal thoracic artery and saphenous veins were used in 47 cases and bilateral internal thoracic arteries were used in 20 cases. Result: Totally 412 distal anastomosis were performed and 376 anastomosis remained patent (91.2%). Left internal thoracic artery showed the most excellent patency in all of the conduits (98.5%). Radial artery graft patency was 90.8% (169/186). There was no statistical difference of the patency by conduit between on-pump and off-pump group. But radial artery showed more higher patency rate (98/110, 89%) in the severe stenotic lesion that preoperatively revealed more than 90% stenosis than in the lesser severe (<90%) stenotic lesion (60/76, 78%)(p < 0.005). Radial artery conduit represented the worst result when it was grafted in the right coronary system. But when it was positioned in the left heart especially diagonal or obtuse marginal area, patency was comparable with left internal thoracic artery. Conclusion: Radial artery graft showed good midterm patency when it was used in the severe stenotic lesion more than 90% and left coronary system. But great notice should be taken when it is grafted in the right coronary system or less severe stenotic lesion.

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

Protocol Optimization of Coronary CT Angiography (심혈관 CT 조영술의 프로토콜 최적화)

  • Lee, Hae-Kag;Yoo, Heung-Joon;Lee, Sun-Yeob;Goo, Eun-Hoe;Seok, Jong-Min;Han, Man-Seok;Lee, Kwang-Sung;Cho, Jae-Hwan;Kim, Bo-Hui;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.51-58
    • /
    • 2011
  • This research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time ${\times}$ 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA. And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.

Diagnosis and Endovascular Treatment of May-Thurner Syndrome (May-Thurner 증후군의 진단과 혈관내 치료)

  • 허균;이재욱;신화균;원용순
    • Journal of Chest Surgery
    • /
    • v.37 no.11
    • /
    • pp.911-917
    • /
    • 2004
  • Background: There are limited number of reports on May-Thurner syndrome (Iliac vein compression syndrome) in Korea, We analysed the clinical features, diagnostic modalities and endovascular treatment of May-Thurner syndrome. Material and Method: We reviewed 12 cases of May-Thurner syndrome between March 2001 and June 2003. Mean age was $57.6\pm2$ years. We were used in venography, color doppler and computed tomographic angiography as diagnostic modalities and in thrombolysis, thrombectomy, angioplasty and stent insertion as endovascular treatment. Result: Clinical features showed edema of lower extremities in 4 patients, pain of lower extremities in 1 patient, edema with pain in 5 patients, and all in 1 patient. In one patient, he did not have any pain and any edema of lower extremities but was diagnosed as May-Thurner syndrome using venography due to varicose veins on lower extremities. Diagnostic modalities included venography, computed tomographic angiography in all patients with clinical presentation except in one patient and color doppler was only performed only in 4 patients. Four kinds of endovascular treatment were performed for May-Thurner syndrome, angioplasty in 11 patients, stent insertion in 10 patients, thrombectomy in 9 patients and thrombolysis for 7 patients. Nine patients were followed up and we can show good blood flow in Left iliac vein for 7 of 9 patients. Conclusion: it is necessary to recognize the possibility of May-Thurner syndrome in Deep vein thrombosis patients and we should use a variety of modalities to diagnose May-Thurner syndrome. Finally, endovascular treatment is a safe and effective therapy for May-Thurner syndrome.

Hindlimb Lameness Secondary to Bilateral Femoral Artery Occlusion in a Dog with Systemic Arterial Dirofilariasis (전신성 동맥 사상충증에 이환된 개의 양측성 대퇴동맥의 폐쇄)

  • Choi, Woo-Shin;Song, Jin-Young;Lee, Young-Jae;Lee, Dong-Hoon;Kim, Ju-Hyung;Chang, Jin-Hwa;Kang, Ji-Houn;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.334-338
    • /
    • 2012
  • A 3-year-old, intact male Pungsan dog was presented for a 2-week history of a non-weight-bearing lameness of left hindlimb with anorexia. The dog had no history of trauma, and never been routinely vaccinated or treated with heartworm preventatives. The complete blood count showed severe leukocytosis and neutrophilia with left shift. Serum biochemistry showed hypoalbuminemia, azotemia, and increased hepatobilliary enzyme activity. A canine heartworm antigen test was positive. Thoracic radiographs were consistent with heartworm disease as evidences by main pulmonary artery enlargement, right-sided cardiomegaly, and interstitial lung pattern. Echocardiography revealed pulmonary valvular regurgitation and pulmonary hypertension. Selective femoral arterial angiogram was performed, and bilateral femoral arterial occlusion was identified. The dog died after angiogram, and necropsy was performed. At necropsy, adult heartworm and a large blood clot were found within the lumen of left and right femoral artery. This case report describes an unusual migration of heartworm to femoral artery that caused hindlimb lameness.

Coronary Angiography after Coronary artery Bypass Grafting (관상동맥 우회술후 관상동맥 조영검사 소견)

  • Choi, Jin-Ho;Park, Kay-Hyun;Jun, Tae-Gook;Lee, Young-Tak;Park, Pyo-Won;Chae, Hurn;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.182-187
    • /
    • 2002
  • Background: There have been many reports of coronary angiographic findings after coronary bypass grafting, most of which are focused on the graft patency rate of the bypass conduits. However, postoperative angiography can provide numerous informations other than patency rates that are useful for establishing operative strategy. Material and Method: We studied 73 patients in whom coronary angiography was done after more than 1 month of CABG. Mean interval from the operation to coronary angiography was 10.6 months and the reasons for coronary angiography follow up were residual or recurrent angina in 54 patients, abnormalities on myocardial perfusion scan or echocardiography in 13 patients, and for simple follow up in 6 patients. Result: Overall graft patency rate was 80.9% (internal thoracic artery 100%, saphenous vein 75.0%) in patients of simple follow up and 61.6%(internal thoracic artery 81.1%, saphenous vein 55.3%) in patients with ischemia. Progression of native coronary arterial disease proximal to the grafting site was found in 50 patients(68.5%). Among 201 coronary arterial branches that had not been completely occluded preoperatively, ninty five branches(47.3%) revealed progression of diameter stenosis by more than 20% on the follow up study. Among them, 64 branches(31.8%) progressed to total occlusion. The incidence of disease progression was highter in the coronary arteries with patent grafts(57.5%) than in those with occluded grafts(36.3%)(p<0.05), Comparing internal thoracic artery graft with saphenous vein graft, internal thoracic artery was superior to saphenous vein, not only in terms of patency(83.3% vs 56.6%), but also in terms of result of later percutaneous intervention success rate(100% vs 62%, p<0.05). Conclusion: Due to the considerable incidence of progression of native coronary artery stenosis in the early postoperative periods, bypass grafting of a vessel with borderline stenosis, especially with vein graft, must be done prudently. And it was confirmed again that revascularization of left anterior descending artery is most important and that internal thoracic artery was superior to saphenous vein.

Evaluation of Radiation Dose to Patients according to the Examination Conditions in Coronary Angiography (심장동맥 조영 검사 시 검사 조건에 따른 환자 선량 평가)

  • Yong-In Cho
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.509-517
    • /
    • 2023
  • This study analyzed imaging conditions and exposure index through clinical information collection and dose calculation programs in coronary angiography examinations. Through this, we aim to analyze the effective dose according to examination conditions and provide basic data for dose optimization. In this study, ALARA(As Low As Reasonably Achievable)-F(Fluoroscopy), a program for evaluating the radiation dose of patients and the collected clinical data, was used. First, analysis of imaging conditions and exposure index was performed based on the data of the dose report generated after coronary angiography. Second, after evaluating organ dose according to 9 imaging directions during coronary angiography, with the LAO fixed at 30°, dose evaluation was performed according to tube voltage, tube current, number of frames, focus-skin distance, and field size. Third, the effective dose for each organ was calculated according to the tissue weighting factors presented in ICRP(International Commission on Radiological Protection) recommendations. As a result, the average sum of air kerma during coronary angiography was evaluated as 234.0±112.1 mGy, the dose-area product was 25.9±13.0 Gy·cm2, and the total fluoroscopy time was 2.5±2.0 min. Also, the organ dose tended to increase as the tube voltage, milliampere-second, number of frames, and irradiation range increased, whereas the organ dose decreased as the FSD increased. Therefore, medical radiation exposure to patients can be reduced by selecting the optimal tube voltage and field size during coronary angiography, maximizing the focal-skin distance, using the lowest tube current possible, and reducing the number of frames.

Laparoscopic Heller Myotomy with Dor Fundoplication in Achalasia -One case report - (식도이완불능증에시 복강경을 이용한 식도근절개술 및 전방위저주름술 - 1예 보고 -)

  • Kim Yeon Soo;Ryoo Ji Yoon
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.258-262
    • /
    • 2005
  • An 18-year old woman had dysphagia and frequent vomiting after meals for 6 years. She lost 15 kg in 6 months recently. After esophageal manometry, she was diagnosed with achalasia. We decided to use laparoscopic surgery because there was no symptomatic improvement after medication. We made small 5 incisions on her abdomen. We performed Heller myotomy and Dor fundoplication. We performed esophagogram one day after the operation. There was no leakage of the contrast media, and it passed well. She started to eat at the 2nd day after the operation and was discharged on the 9th day without other specific problem.

A Case of Alagille Syndrome with Atresia of the Hepatic Duct (간관 폐쇄증이 동반된 알라질 증후군 (Alagille Syndrome) 1예)

  • Kim, Hyo-Sun;Koh, Hong;Chung, Ki-Sup;Oh, Jung-Tak;Park, Young-Nyun;Kim, Myeung-Jun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.65-69
    • /
    • 2008
  • A two-month-old baby had acholic stool, neonatal hyperbilirubinemia and congenital heart disease. Atresia of the hepatic duct was confirmed by open cholangiography, which showed a non-opacified intrahepatic bile duct. Liver biopsy and the Kasai operation were performed. Because the liver biopsy pathology revealed a paucity of intrahepatic bile ducts, the patient was diagnosed with the Alagille syndrome. We report the case of an infant diagnosed with the Alagille syndrome with atresia of the hepatic duct.

  • PDF

Innominate Artery Ruplure Caused by Blunt Chest Trauma -A Case Report (흉부둔상에 의한 무명동맥 파열 -치험 1례-)

  • Lee, Gun;Kim, Yong-In
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.1028-1031
    • /
    • 1997
  • Rupture of an innominate artery caused by blunt chest trauma is extremel rare because this artery is short and relatively well protected by the bony cage. This report describes a 37-year-old male who sustained a blunt chest injury that resulted in an innominate artery rupture, detected by chest CT and thoracic aortography. The patient underwent an urgent operation through median sternotomy. A 3 by 3 m sized pseudoaneurysm of proximal innominate artery was found with a complete intimal tear. After the origin of the innominate artery was closed, the injured segment of artery was excised and an aorto-innominate artery bypass with a 10 mm Gore-tex graft was performed without use of a shunt. The patient was discharged 20 days later without neurologic complications and had equal blood pressure in both arms.

  • PDF