• Title/Summary/Keyword: 심장분할

Search Result 50, Processing Time 0.034 seconds

Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study (호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 2003
  • Purpose : The efficacy of magnetic resonance imaging for evaluating coronary artery disease has been reported. In this study, we evaluated the usefulness of breath-hold segmented K-space cine MR imaging for evaluating the patency of coronary artery bypass grafts (CABG). Materials and Method s : Thirty eight patients with a total of 92 CABGs (36 internal thoracic arteries and 56 saphenous vein grafts) were evaluated using segmented K-space cardiac-gated fast gradient echo sequence (2D-FASTCARD) MR imaging. MR magnitude images were evaluated from the hard copies by two independent observers. A graft was defined as patent if it was seen as a bright small round area on at least two consecutive images throughout the cardiac cycle at a position consistent with the expected location for that graft. Results : MR images were obtained successfully for 23 patients (61%). The sagittal planes were most helpful in visualizing the cross-section of sapheneous vein bypass graft to left circumflex artery branch, whereas the transverse planes were used for identification of internal mammary artery grafts to left anterior descending coronary artery or its branch and identification of saphenous vein grafts to right coronary artery. Forty five grafts were visible using this MR technique, while the grafts were not visible on seven saphenous vein grafts and two internal mammary artery grafts. In two patients showing symptoms of myocardial ischemia, one or two bypass grafts were not visible. Imaging, perpendicular plane to a CABG was important to visualize the flow inside the CABG with maximum sensitivity. Conclusion : Evaluation of patency of the bypass graft was clinically feasible by 2D-FASTCARD MR imaging, whereas any invisible bypass grafts should be further studied by contrast-enhanced MR angiography or by conventional angiography for confirmation of abnormalities.

  • PDF

Results of Concurrent Chemoradiotherapy and Intraluminal Brachytherapy in Esophageal Carcinoma - Retrospective Analysis with Respect to Survival - (식도암에서 동시 항암화학방사선요법과 관내근접치료의 결과 -생존율을 중심으로 한 후향적 분석-)

  • Nam Taek-Keun;Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Song Ju-Young
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • Purpose : Evaluate the efficacies and toxicities of concurrent chemoradiotherapy (CCRT), with or without intraluminal brachytherapy (ILB), using a retrospective analysis in esophageal carcinomas with respect to survival. Materials and Methods : From April 1995 to July 2001, a total of 65 patients, diagnosed with an esophageal carcinoma, were treated by CCRT, with 21 also treated by ILB after CCRT. External radiotherapy was peformed using 6 or 10 MV X-rays, with a dose range of $46.8~\69.6$ Gy (median; 59.4). The ILB was peformed using high-dose-rate brachytherapy with Ir-192. The fractionation of ILB was 3 Gy by 4, or 5 Gy by 2 fractions. Cisplatin $(75\;mg/m^2)$ was given on each first day of weeks 1, 5, 9 and 13, and 5-FU $(1,000\;mg/m^2)$ as a continuous infusion for the first 4 days of each course. Results : The median survival time of all patients was 15 months, and the 1, 2 and 3-year survival rates were 55.4, 29.2 and $20.7\%$, respectively. The 2-year survival rates of the patients with and without ILB were 33.3 and $27.3\%$, respectively (p=0.80). The 2-year survival rates of the patients with a complete, partial and no response were 44.1, 13.8 and $0\%$, respectively (p=0.02). The response to treatment was the only significant factor affecting the overall survival from a multivariate analysis. Conclusion : This study has shown that the survival outcomes of CCRT were much better than previous results with radiotherapy alone. However, the addition of ILB after CCRT showed no advantage over that of CCRT alone.

Development of Velocity Imaging Method for Motility of Left Ventricle in Gated SPECT (게이트 심근 SPECT에서 좌심실의 운동성 분석을 위한 속도영상화 기법 개발)

  • Jo, Mi-Jung;Lee, Byeong-Il;Choi, Hyun-Ju;Hwang, Hae-Gil;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.7
    • /
    • pp.808-817
    • /
    • 2006
  • Although the generally used the velocity index of doppler effect is a very significant factor in the functional evaluation of the left ventricle, it depends on the subjective evaluation of an inspector. The objective data of the motility can be obtained from the gated myocardial SPECT images by quantitative analysis. However, it is difficult to image visual of the velocity of the motion. The aim of our study is to develop a new method for the imaging velocity using the gated myocardial SPECT images and use it as an evaluation index for analyzing motility. First we visualized left ventricle into 3 dimensions using the coordinates of the points which were obtained through a segmentation of myocardium. Each point was represented by the different colors, according to the velocity of each point. We performed a validation study using 7 normal subjects and 15 myocardial infarction patients. To analyze motility, we used the average of the moved distance and the velocity. In normal cases, the average of the moved distance was 4.3mm and the average of the velocity was 11.9mm. In patient cases, the average of the moved distance was 3.9mm and the average of the velocity was 10.5mm. These results show that the motility of normal subjects is higher than the abnormal subjects. We expect that our proposed method could become a way to improve the accuracy and reproducibility for the functional evaluation of myocardial wall.

  • PDF

Objective and Quantitative Evaluation of Image Quality Using Fuzzy Integral: Phantom Study (퍼지적분을 이용한 영상품질의 객관적이고 정량적 평가: 팬톰 연구)

  • Kim, Sung-Hyun;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.201-208
    • /
    • 2008
  • Physical evaluations provide the basis for an objective and quantitative analysis of the image quality. Nonetheless, there are limitations in using physical evaluations to judge the utility of the image quality if the observer's subjectivity plays a key role despite its imprecise and variable nature. This study proposes a new method for objective and quantitative evaluation of image quality to compensate for the demerits of both physical and subjective image quality and combine the merits of them. The images of chest phantom were acquired from four digital radiography systems on clinic sites. The physical image quality was derived from an image analysis algorithm in terms of the contrast-to-noise ratio (CNR) of the low-contrast objects in three regions (lung, heart, and diaphragm) of a digital chest phantom radiograph. For image analysis, various image processing techniques were used such as segmentation, and registration, etc. The subjective image quality was assessed by the ability of the human observer to detect low-contrast objects. Fuzzy integral was used to integrate them. The findings of this study showed that the physical evaluation did not agree with the subjective evaluation. The system with the better performance in physical measurement showed the worse result in subjective evaluation compared to the other system. The proposed protocol is an integral evaluation method of image quality, which includes the properties of both physical and subjective measurement. It may be used as a useful tool in image evaluation of various modalities.

  • PDF

Mitral Valve Reconstruction in Mitral Insufficiency : Intermediate-Term Results (승모판 폐쇄부전증에서 승모판 재건술의 중기평가)

  • 김석기;김경화;김공수;조중구;신동근
    • Journal of Chest Surgery
    • /
    • v.35 no.10
    • /
    • pp.705-711
    • /
    • 2002
  • The advantages of mitral valve reconstruction have been well established and so mitral valve reconstruction is now considered as the procedure of choice to correct mitral valve disease. This is the report of intermediate-term results of 38 cases that performed mitral valve reconstruction for valve insufficiency(the total number of mitral valve reconstruction were 49 cases, but 11 cases that performed mitral valve replacement due to incomplete reconstruction were excluded). Material and Method : From March 1991 to March 2001, 38 patients underwent mitral valve repair due to mitral valve regurgitation with or without stenosis. Mean age was 47.6$\pm$14.7 years(range 15 to 70 years) : 11 were men and 27 were women. The causes of mitral valve regurgitation were degenerative in 14, rheumatic in 21, infective in 2 and the other was congenital. Result : According to the Carpentier's pathologic classification of mitral valve regurgitation, 3 were type 1 , 16 were type II and 19 were type III. Surgical procedures were annuloplasty 15, commissurotomy 19, leaflet resection and annular plication 9, chordae shortening 11, chordae transfer 5, new chordae formation 2, papillary muscle splitting 2 and vegetectomy 2. These procedures were combined in most patients. There were 2 early death and the causes of death were respiratory failure, renal failure and sepsis. There was no late death. Valve replacement was done in 6 patients after repair due to valve insufficiency or stenosis 3 weeks, 1, 3, 51, 69, 84months later respectively. These patients have been followed up from 1 to 116 months(mean 43.0 months). The mean functional class(NYHA) was 2.36 pre-operatively and improved to 1.70. Conclusion : In most cases of mitral valve regurgitation, mitral valve reconstruction when technically feasible is effective operation that can achieve stable functional results and low surgical and late mortality.

An Epidemiologic Study of Kawasaki Disease(1987-2000) : Incidence of Coronary Artery Complication in the Acute Stage (가와사끼병의 역학적 연구(1987-2000년) : 관상 동맥 이상을 중심으로)

  • Lee, Kyung-Yil;Park, Min-Young;Han, Ji-Whan;Lee, Hyung-Shin;Choi, Jin;Whang, Kyung-Tai
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.6
    • /
    • pp.783-789
    • /
    • 2002
  • Purpose : We evaluated the epidemiologic characteristics and incidence of coronary artery sequele of children with KD according to treatment. Methods : We retrospectively analyzed 506 medical records of children with KD, who were admitted at Daejeon St. Mary's Hospital from Jan. 1987 to Dec. 2000. Results : The mean annual incidence was $36.1{\pm}11.1$ cases per year. There was a slightly higher occurrence in summer with no significant difference in monthly incidence. The mean age was $2.4{\pm}1.7$ years and 450 children(88.9%) were below four years of age. The male to female ratio was 1.7 : 1. When the 345 cases between 1987 and 1994 were divided into three groups according to treatment, incidences of the coronary abnormality(above grade II) of aspirin-treated(54 cases; 15.6%), divided-intravenous immunoglobulin(IVIG) treated($400-500mg/day{\times}4-5days$, 224 cases; 64.9%), and one-dose IVIG treated(2.0 g/day, 67 cases; 19.5%) groups were 8.3%, 6.0%, and 7.5%, respectively. Between 1995 and 2000, 143 cases were treated with only one-dose IVIG and 21 cases(14.7%) showed coronary artery abnormalities(grade I, 15 cases; grade II, two cases; and grade III, four cases). Among the 143 cases, 22 cases(15.1%) were retreated with IVIG and/or steroid pulse therapy. The incidence of coronary artery abnormality in this group was 50.0%. Incidences of cases in recurrence and among siblings were 0.6% and 0.4% respectively. There was no fatal case. Conclusion : In Daejeon, Korea, the epidemiologic feature of KD showed slight annual variations without monthly differences. The incidence of coronary abnormality with one-dose IVIG therapy was 14.7%. The nonresponse of this therapy was 15.1% with a coronary abnormality of 50.0%.

Treatment Outcome of Thymic Epithelial Tumor: Prognostic Factors and Optimal Postoperative Radiation Therapy (흉선상피종의 치료 성적: 예후 인자 및 방사선치료 방법에 대한 연구)

  • Oh Dong Ryul;Ahn Yong Chan;Kim Kwan Min;Kim Jhingook;Shim Young Mog;Han Jung Ho
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.85-91
    • /
    • 2005
  • Purpose : This study was conducted to analyze treatment outcome and prognostic significance of World Health Organization (WHO)-defined thymic epithelial tumor (TET) subtype and to assess optimal radiation target volume in patients receiving surgery and adjuvant radiation therapy with TET. Materials and Methods: The record of 160 patients with TET, who received surgical resection at the Samsung medical Center, from December 1994 to June 2004, were reviewed. 99 patients were treated with postoperative radiation therapy (PORT). PORT was recommended when patients had more than one findings among suspicious Incomplete resection or positive resection margin or Wasaoka stage $II\~IV$ or WHO type $B2\~C$. PORT peformed to primary tumor bed only with a mean dose of 54 Gy. The prognostic factor and pattern of failure were analyzed retrospectively. Results : The overall survival rate at 5 years was $87.3\%$. Age (more than 60 years $77.8\%$, less than 60 years $91.1\%$; p=0.03), Wasaoka stage (I $92.2\%$, II $95.4\%$, III $82.1\%$, IV $57.5\%$; p=0.001), WHO tumor type (A-Bl $96.0\%$, B2-C $82.3\%$; p=0.001), Extent of resection (R0 resection $92.3\%$, R1 or 2 resection $72.6\%$, p=0.001) were the prognostic factors according to univariate analysis. But WHO tumor type was the only significant prognostic factor according to multivariate analysis. Recurrence was observed in 5 patients of 71 Masoka stage I-III patients who received grossly complete tumor removal (R0, R1 resection) and PORT to primary tumor bed. Mediastinal recurrence was observed In only one patients. There were no recurrence within irradiation field. Conclusion : WHO tumor type was the important prognostic factor to predict survival of patients with TET. This study suggest that PORT to only primary tumor bed was optimal. To avoid pleura- or pericardium-based recurrence, further study of effective chemotherapy should be investigated.

The Evaluation of Hybrid-Volumetric Modulated Arc Therapy for Lung Cancer Radiation Therapy (폐암 방사선 치료 시 Hybrid-Volumetric Modulated Arc Therapy의 유용성 평가)

  • Lee, Geon Ho;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Du Sang;Ahn, Min Woo;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: In the Lung, the VMAT rotates continuously and examines radiation. That increases the low doses to normal lung. Due to that, the incidence of radiation pneumonia among radiation side effects may increase. The cause of radiation pneumonia is the lower dose area of the lungs. The H-VMAT was applied to patients who applied to reduce radiation in the lower doses of the lungs. We wanted to assess the usefulness of the H-VMAT by comparing the radiation doses to the low dose areas of the lungs and the normal organs. Materials and Methods: A total of 26 patients who applied for a H-VMAT procedure were applied to the patient. The prescription dose applied to total dose 44 Gy from 22 divisions. For each patient, a plan was implemented with Conventional RT, VMAT and H-VMAT. Conventional RT was carried out in four to five fields each, considering the size, location, shape, and location of the PTV. In the case of a VMAT plan, the two Half ARC, three Half ARC method and the two Full ARC were planned. The H-VMAT was planned by adding two Static fields in the VMAT, taking into account the dose of the lung and the tolerance dose of the organs. Results: In the NSCLC, the lung doses $V_5$ and $V_{10}$ of the lungs except for the treatment plan volume were the lowest with $55.40{\pm}13.39%$ and $32.05{\pm}11.37%$ of H-VMAT. And, in the SCLC, the lung doses of V5 and V10 were the lowest at $64.32{\pm}16.15%$ and $35.50{\pm}9.91%$, respectively. The spinal dose of VMAT in NSCLC was $21.15{\pm}4.02Gy$, which was 7.94 Gy lower than other treatment methods. The lowest spinal dose was delivered at $19.72{\pm}1.82Gy$ for SCLC. The mean dose delivered to the esophagus was also $17.44{\pm}2.04Gy$ and $17.84{\pm}9.20Gy$ in SCLC and NSCLC, respectively. Conclusion: When comparing the value of the surrounding normal organ dose, the VMAT showed that less doses were transmitted from the heart, esophagus and spinal cord than the rest of the treatment plan. However, it was similar to VMAT in normal organs except for the spinal cord. VMAT has increased doses of some normal organs but did not exceed the tolerance dose. It showed a low value in $V_5$, $V_{10}$. When comparing Conventional RT, VMAT, and H-VMAT, If the dose to the heart, esophagus and spinal cord is lower than the tolerance dose, it is thought to reduce the incidence of radiation pneumonia by applying H-VMAT that show the benefits of low doses of the lungs.

  • PDF

Preservation of Subvalvular Apparatus During Mitral Valve Replacement (판막하부 구조물을 보존하는 인공 승모판막 치환술)

  • 임창영;임정철
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1329-1336
    • /
    • 1996
  • From January, 1994 to January. 1996, mitral valve replacement was performed in 27 patients. Among these, 17 patients underwent mitral valve replacement(MVR) with preservation of the annulo-papillary continuity(PAPCMVR) (-Group I), and 10 patients underwent conventional methods of excision of all the chordae(Group II). The operative technique for PAPCM VR consists of the division of the anterior leaflet into anterior and posterior segments, shifting and reattachment of the divided segments to the mitral ring of the respective commissural areas. This retrospective study has been designed to evalute the postoperative left ventricular function in the two groups. In the group 1, LVEF(Left Vnetricular Ejection Fraction : %) was 52 $\pm$ 3 preoperatively And 50$\pm$3 postoperatively, LVESI Vent icular End Systolic Volume Index/mL/m2) wIns 59 :6 and 51 $\pm$ 7, LVEDI Ventricular End Diastolic Volume Index/mL/m2) was 124$\pm$ 11 and 91 :8. In the group II, LVEF was 56$\pm$1 and 47:), LVESVI 62$\pm$12 and 61$\pm$15, LVEDVI 133$\pm$27 and 104$\pm$17. : the variation of the LVEF in these two group was statistically different(p(0.05). A comparison of left ventricular function data between Group I(n: 17) and Group II(n: 10) revealed better results in echocardiographic LVEF(p<0.05), LVEDVI(p<0.01) in the former group. The mean functional class(UYHA) was 2.6 preoperative and improved to 1.0 postoperatively In group 1, and 2.8 and to 1.0 in group II. We conclude that maintenance of continuity between the mitral annulus and papillary muscles is expected to have a beneficial effect on postoperative left ventricular performance.

  • PDF

The dosimetric guide of treatment modalities for Left side breast irradiation after conservative surgery (좌측 유방암 방사선 치료 시 치료 기법에 따른 선량적 고찰)

  • Kim, Tae Min;Moon, Sung Kong;Kim, Li Zzy;Kim, Se Young;Park, Ryeung Hwang;Kim, Joo Ho;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose : We retrospectively analyzed doses of each radiation therapy technique used in the treatment for left breast cancer patients after partial mastectomy through dose results for normalorgans and tumor volume to use this as a clinical reference for radiation therapy of domestic left breast cancer patients. Materials and Methods : 40 patients who underwent partial mastectomy on left breast cancer were classified in 3 treatment methods. The treatment plan was evaluated by HI(homogeneity index), $D_{95%}$, and CI(conformity index), and the $V_{hot}$ for gross tumor volume and clinical target volume of each treatment method. In Cyberknife treatment, tumor volume was the same as high dose volume in the other techniques, so no consideration was given to clinical target volume. Treatment plan evaluation for normal organs were evaluated by mean dose on ipsilateral lung, heart, left anterior descending artery, opposite breast and lung, and non-target tissue. Result : Treatment with volumetric arc radiotherapy(VMAT) showed $95.84{\pm}0.75%$ of $D_{95%}$ on the clinical target volume, significantly higher than that of 3D-CRT. The $D_{95%}$ value of the total tumor volume was slightly higher than the other treatments. In Cyberknife treatment, the dose to the normal organs was significantly lower than other treatments. Overall, the maximum dose and mean dose to the heart were $26.2{\pm}6.12Gy$ and $1.88{\pm}0.2Gy$ in VMAT treatment and $20.25{\pm}9.35Gy$ and $1.04{\pm}0.19Gy$ in 3D-CRT therapy, respectively. Conclusion : In comparison on 3D-CRT and VMAT, most of the dosimetric parameters for the evaluation of the treatment plan showed similar values, so that there is no significant difference in treatment plan evaluation. It is possible to select the treatment method according to the patient's anatomical structure or possibility of breath control. Cyberknife treatment is very useful treatment for normal organs because of its accurate dose exposure to the tumor volume However, it has restrictions to treat the local area, to have relatively long treatment time and to involve invasive procedure.

  • PDF