• Title/Summary/Keyword: 심미치과

Search Result 1,131, Processing Time 0.037 seconds

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel. undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesio-distally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference on fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even of that portion consists of mainly enamel and a little dentin structure.

  • PDF

CHEMICAL DEGRADATION OF VARIOUS COMPOMERS IN NaOH (콤포머의 NaOH 용액 내에서의 화학적 분해)

  • Park, Mi-Ran;Choi, Nam-Ki;Lee, Young-Jun;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.144-152
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation of three commercial compomers in an alkaline solution. Dyract(Dentsply), Elan(Kerr) and F-2000(3M) polyacid modified resin composites(compomers) were used in this study. The resistance to degradation was evaluated on the basis of mass loss(%), degradation $depth({\mu}m)$ and Si, Al, Ba loss(ppm). The results were as follows : 1. The mass loss of each brand was $1.42%{\sim}2.14%$ and there was no statistically significant difference of mass loss among Dyract, F2000 and Elan. 2. The degradation layer depth of each brand was $182.92{\sim}227.7{\mu}m$ and there was no statistically significant difference of degradation layer depth among Dyract, F2000 and Elan. 3. There was statistically significant differences in Si-loss and Al-loss among three compomers (p<0.05). Si loss was the highest value in Dyract and Al loss was the highest value in F2000. 4. There was statistically significant correlation between mass loss and degradation layer depth (r=0.60, p<0.05). 5. In SEM finding, there was some destruction of compomer matrix-filler interface in post-exposure specimen to NaOH solution. As the matrix decreased, the filler particles distinguished and the periphery of the filler particles appeared whitish color due to degradation.

  • PDF

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.

Considerations in implant crestal module to preserve peri-implant tissue (임플란트 주위 조직 보존을 위한 임플란트 경부의 디자인에 관한 고찰)

  • Kim, Hong-Jun;Kim, Jee-Hwan;Kim, Sung-Tae;Lee, Jae-Hoon;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.346-353
    • /
    • 2011
  • Purpose: The peri-implant soft tissue is remodeled by the initial marginal bone resorption affecting the prognosis and esthetic result of treatment. Thus various designs on implant neck design are studied to preserve peri-implant bone. The purpose of this study is to review on the causes of initial marginal bone resorption, the configuration of peri-implant soft tissue, and the implant crestal module favorable in preserving peri-implant tissue. Materials and methods: The studies on the causes of initial marginal bone resorption and the implant crestal modules are researched and reviewed using Pubmed database. The implant crestal modules including one piece and two-piece implant, internal and external hex abutment, taper and butt joint connection, scalloped design abutment, and platform switching concept are reviewed. Results: A number of clinical and experimental studies preferred one piece implant to two-piece in preserving initial peri-implant tissue. For two piece implants, internal hex abutment and taper joint connection appear more favorable than external hex abutment and butt joint connection relatively. Controversial issues still exist on scalloped design requiring more studies on it. Although the rationale is not certain, the concept of platform switching seems favorable in preserving initial peri-implant tissue based on clinical and experimental studies. Conclusion: Each implant crestal module contains its own advantages and disadvantages with various controversial issues. In the aspect of preservation of initial peri-implant tissue, however, one-piece implant seems beneficial. In cases when two-piece implant is more appropriate due to prosthodontic concerns or any other problems, the application of platform switching concept, internal connection abutment, and taper joint connection may be favorable for the preservation of peri-implant tissues.

HYDROLYTIC DEGRADATION OF POSTERIOR RESIN RESTORATIVE MATERIALS (구치부 레진 수복 재료의 가수분해)

  • Yang, Kuy-Ho;Park, Mi-Ran;Choi, Nam-Ki;Park, Eun-Hae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.673-682
    • /
    • 2001
  • The use of resin composites has continued to increase over the last several years. In spite of their growing popularity, composites continue to exhibit a number of undesirable characteristics. One of the major deficiencies of composite restorative resins is their inadequate resistance to wear. Of the multitude of factors that have been associated with wear, subsurface degradation within the restoration is considered to be one. The aim of this study was to evaluate the resistance to degradation of four commercial composite resins in an alkaline solution. This solution with a high concentration of hydroxyl ions is a convenient medium for accelerated degradation of silane coupling and filler particles. The brands studies were Definite($Degussa-H\ddot{u}ls$ AG, Germany), Prodigy(Kerr, USA), Pyramid(Bisco, USA) and Synergy(Coltene, Swiss). Preweighed discs of each brand were exposed to 0.1N NaOH solution at $60^{\circ}C$. After 14 days they were removed, neutralized with HCl, washed with water and dried. Resistance to degradation was evaluated on the basis of following parameters : (a) mass loss(%)-determined from pre-and post-exposed specimen weights : (b) Si loss(ppm)-obtained from ICP-AE analysis of solution exposed to specimens; and (c) degradation $depth({\mu}m)$-measured microscopically (SEM) from polished circular sections of exposed specimens. The results were follows: 1. Mass loss of Synergy was $1.24{\pm}0.002%$, it was the highest, there was no significant difference among the materials. 2. The degree of degradation layer depth of Synergy was $107.83{\pm}2.52{\mu}m$, it was the highest, there was no significant difference among any other materials than Synergy. 3. There was no difference among the four materials in Si loss. 4. The correlation coefficient between mass loss and degradation depth was relatively high(r=0.06, p<0.05). 5. There was no coefficient correlation between Si loss and mass loss, the degree of degradation layer depth and Si loss. 6. When observed with SEM, destruction of bonding is observed between resin matrix and filler.

  • PDF

Study on the Relationships Among Perceived Shopping Values, Brand Equity, and Store Loyalty of Korean and Chinese Consumers: A Case of Large Discount Store (한국과 중국 소비자의 쇼핑 경험가치 지각과 브랜드자산 및 점포충성도의 관계에 관한 비교 연구: 대형 할인점을 중심으로)

  • Hwang, Soonho;Oh, Jongchul;Yoon, Sungjoon
    • Asia Marketing Journal
    • /
    • v.14 no.2
    • /
    • pp.209-237
    • /
    • 2012
  • 1. Research Purpose Consumers rely on various clues to evaluate their decision to patronize a retail store, and store brand is one of them (Dodds 1991; Grewal et al. 1998). As consumers find ever increasing variety of contact points connecting them to specific store, the value of experiential shopping as a means of increasing store's brand equity warrants greater attention from scholars of retail management. Retail shopping values are credited for creating not only cognitive experiences like brand knowledge but also emotional experiences such as shopping pleasure and pride (Schmitt 1999). This may be because today's consumers place emphasis on emotional values associated with shopping pleasure, lifestyle brought to life, brand relationship, and store atmosphere more than utilitarian values such as product quality and price. Many previous literature found this to be true (Ahn and Lee 2011; Mathwick et al. 2001). This brings forth important research issues and questions regarding the roles of shopping experiential values and brand equity with regard to consumer's retail patronage choice. However, despite this importance, research on this area remains quite inadequate (Hwang 2010). For this reason, this study aims to verify the relationships among experiential shopping values, retail store brand equity and tries to link that with customer loyalty by surveying large-scale discount store shoppers in Korea and China. 2. Research Contents In order to carry out the research objective, this study conducted comprehensive literature survey on previous literature by discussing major findings and implications with regard to shopping values and retail brand equity and store loyalty. For data collection, researcher employed survey-based research method where data were collected in two major cities of Korea (Seoul) and China (Bejing) and sampling frame was based on patrons of large discount stores in both countries. Specific research questions raised in this study are as follows; RQ1: How do Korean and Chinese consumers differently perceive of shopping values regarding shopping at large-sclae discount stores? RQ2: Are there differences in consumers' emotional consumption propensities? RQ3: Do Korean and Chinese consumers display different perceptions of brand equity towards large-scale discount stores? RQ4: Are there differences in relationships between shopping values and brand equity for Korean and Chinese consumers? For statistical analysis, SPSS17.0, AMOS17.0 and SmartPLS were employed. 3. Research Results The data collected through face-to-face survey conducted in Seoul and Bejing revealed appropriate data validity and reliability as a result of exploratory/confirmatory factor analysis and reliability tests, andh SEM model yielding satisfactory model fitness. The result of the study may be summarized by three main points. First, as a result of testing differences in consumption dispositions, Chinese consumers showed higher scores in aesthetic and symbolic dispositions, whereas Korean consumers scored higher in hedonic disposition. Second, testing on perceptions toward brand equity of large discount stores showed that Korean consumers exhibited more positive perceptions of brand awareness and brand image than Chinese counterparts. Third, the result of exploratory factor analysis on the experiential shopping values revealed different factors for each country. On Korean side, consumer interest value, aesthetic value, and hedonic value were prominent, whereas on Chinese side, hedonic value, aesthetic value, consumer interest value, and service excellence value were found salient. 4. Research Implications While many previous studies on inter-country differences in retailing area mainly focused on cultural dispositions or orientations to explain the differences, this study sets itself apart by specifically targeting individual consumer's shopping values from an experiential viewpoint. The study result provides important theoretical as well as practical implications for large-scale discount store, especially the impotance of fully exploring the linkage between shopping values and brand equity, which has significant influence on loyalty. Therefore, the specific implications deriving from the result shed some important insights upon the consumption values based on shopping experiences and brand equity. The differences found in store shoppers between the two countries may also provide useful insights for Korean and Chinese retailers who plan to expand their operations globally. Related strategic implications derived from this study is the importance of localizing retail strategy which is based on the differences found in experiential shopping values between the two country groups. Especially the finding that Chinese consumers value consumer interest and service excellence, whereas Koreans place importance on hedonic or aesthetic values indicates the need to differentiate the consumer's psychographical profiles when it comes to expanding retail operations globally. Particularly important will be to pursue price-orienated strategy in China in consideration of the high emphasis on consumer interests and service excellence, but to emphasize the symbolic aspects of brand equity in Korea by maximizing the brand equity associated with aesthetic values and hedonic orientations. 5. Recommendations This study focused on generic retail branded discount stores in both countries, thus making it difficult to tease out store-specific strategies based on specific retail brands. Future studies may benefit fro employing actual brand names in survey questionnaire to verify relationship between shopping values and brand-based store strategy. As with other studies of this nature, this study needs to strengthen the result's generalizability by selecting respondents from a wider spectrum of respondents.

  • PDF

COMPARISON OF POLYMERIZATION SHRINKAGE AND STRAIN STRESS OF SEVERAL COMPOSITE RESINS USING STRAIN GUAGE (스트레인 게이지를 이용한 수종의 복합레진의 중합수축 및 수축응력의 비교)

  • Kim, Young-Kwang;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.516-526
    • /
    • 2004
  • Polymerization shrinkage of photoinitiation type composite resin cause several clinical problems. The purpose of this study was to evaluate the shrinkage strain stress, linear polymerization shrinkage, compressive strength and microhardness of recently developed composite resins. The composite resins were divided into four groups according to the contents of matrix and filler type. Group I : $Denfil^{TM}$(Vericom, Korea) with conventional matrix, Group II : $Charmfil^{(R)}$(Dentkist, Korea) with microfiller and nanofller mixture, Group III : $Filtek^{TM}$ Z250(3M-ESPE, USA) TEGDMA replaced by UDMA and Bis-EMA(6) in the matrix, and Group IV : $Filtek^{TM}$ Supreme(3M-ESPE, USA) using pure nanofiller. Preparation of acrylic molds were followed by filling and curing with light gun. Strain gauges were attached to each sample and the leads were connected to a strainmeter. With strainmeter shrinkage strain stress and linear polymerization shrinkage was measured for 10 minutes. The data detected at 1 minute and 10 minutes were analysed statistically with ONE-way ANOVA test. To evaluate the mechanical properties of tested materials, compressive hardness test and microhardness test were also rendered. The results can be summarized as follows : 1. Filling materials in acrylic molds showed initial temporary expansion in the early phase of polymerization. This was followed by contraction with the rapid increase in strain stress during the first 1 minute and gradually decreased during post-gel shrinkage phase. After 1 minute, there's no statistical differences of strain stress between groups. The highest strain stress was found in group IV and followed by group III, I, II at 10 minutes-measurement(p>.05). In regression analysis of strain stress, group III showed minimal inclination and followed by group II, I, IV during 1 minute. 2. In linear polymerization shrinkage test, the composite resins in every group showed initial increase of shrinkage velocity during the first 1 minute, followed by gradually decrease of shrinkage velocity. After 1 minute, group IV and group III showed statistical difference(p<.05). After 10 minutes, there were statistical differences between group IV and group I, III(p<.05) and between group II and group III(p<.05). In regression analysis of linear polymerization shrinkage, group II showed minimal inclination and followed by group IV, III, I during 1 minute. 3. In compressive strength test, group III showed the highest strength and followed by group II, IV, I. There were statistical differences between group III and group IV, I(p<.05). 4. In microhardness test, upper surfaces showed higher value than lower surfaces in every group(p<.05).

  • PDF

Fracture load and marginal fitness of zirconia ceramic coping by design and coloration (유색 및 백색 지르코니아 세라믹 코핑의 코핑 디자인에 따른 파절 하중과 변연 적합성)

  • Shin, Mee-Ran;Kim, Min-Jeong;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.406-415
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the marginal fitness and fracture load of the zirconia copings according to the design with different thickness and coloration. Material and methods: The evaluation was based on 80 zirconia copings. Zirconia copings were fabricated in design with different thicknesses using CAD/CAM system (Everset, KAVO dental GmbH, Biberach, Germany). The designs of copings were divided into four groups. The first group consisted of copings with uniform thickness of 0.3 mm. The thickness in the second group was 0.3 mm on the buccal surface and 0.6 mm on the lingual surface. The third group consisted of coping with uniform thickness of 0.6 mm. The thickness in the fourth group was 0.6 mm on the buccal surface and 1mm on the lingual surface. Each group consisted of 10 colored and 10 uncolored copings. Half of the copings (40) processed with a milling system according to the specific design were sent to be given a color (A3) through saturation in special dye by a manufacturing company. Just after sintering, the marginal discrepancies of copings were measured on the buccal, lingual, mesial and distal surfaces of metal die, under a Video Microscope System (sv-35, Sometech, Seoul, Korea) at a magnification of $\times$ 100. It was remeasured after the adjusting of the inner surface. Next, all copings were luted to the metal dies using reinforced cement {GC FujiCEM (GC Corp. Tokyo, Japan)} and mounted on the testing jig in a Universal Testing Machine (Instron 4467, Norwood, MA, USA). The results were analyzed statistically using the one-way ANOVA test. Results: The obtained results were as follow: 1. The measured value of marginal discrepancy right after sintering was the greatest in the contraction of the buccal area in all groups, except for group I2. 2. There was no significant difference of marginal fitness among the groups in the colored zirconia group (P<.05). 3. When the marginal fitness among the groups in the uncolored zirconia group was considered, group II2 had the smallest marginal discrepancy. 4. When the colored and uncolored groups with the same design were compared, there was a significant difference between I1 and II1 groups. In group 2, 3, and 4, the uncolored zirconia had the greatest marginal fitness (P<.05). 5. After adjustment of inner surface, there was no significant difference in the marginal fitness in all groups when color and design of the zirconia coping were compared. 6. The fracture load of CAD/CAM zirconia copings showed significant difference in group 1, 2, 3, and 4. I4 and II4 had the strongest fracture load. 7. When groups with different color and same design were compared, all colored groups showed greater fracture load (P>.05), with no significance. Conclusion: There was difference in the marginal fitness according to the design and coloration of zirconia copings right after sintering, but it was decided that the copings may well be used clinically if the inner surface are adjusted. The copings should be thick enough for the reinforcement of fracture strength. But considering the esthetics of the visible surfaces (labial and buccal surface), the thickness of copings may be a little thin, without giving any significant effect on the fracture strength. This type of design may be considered when giving priority to preservation of tooth or esthetics.

Oral Health and Eating Habit Attributes Relating to the Maxillary Anterior Teeth Color by Using the ShadeEye NCC (ShadeEye NCC를 이용한 상악전치부 색조와 구강보건 및 식습관 관련 특성 비교)

  • Yoon, Young-Suk
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.348-358
    • /
    • 2012
  • This study aims to prepare the basic data of the teeth color by measuring analyze mode using the color of the maxillary anterior teeth (maxillary central incisor, lateral incisor, canine) of the college students in their twenties as the dental colorimeter. The maxillary anterior teeth of the subjects of study as 467 students (male 89, female 378) were measured from 14 November to 2 December, 2011, so the color of total 1,401 teeth was examined, and oral health and eating habit attributes were researched. The survey results were as follows. 1. The color of maxillary anterior teeth was changed from maxillary central incisor to maxillary canine, brightness ($L^*$) was decreased $76.79{\pm}4.86$ to $69.72{\pm}4.62$, red chroma ($a^*$) was increased $2.02{\pm}2.00$ to $4.10{\pm}2.60$, yellow chroma ($b^*$) was increased $15.51{\pm}3.42$ to $20.10{\pm}3.46$. 2. Brightness ($L^*$) was different according to sex (p< 0.001), major (p<0.001), grade (p<0.001), smoking (p<0.001), oral health education (p<0.01), daily brushing frequency (p<0.001), brushing method (p<0.05), oral hygiene devices (p<0.001), and red chroma ($a^*$) to major (p<0.001), daily brushing frequency (p<0.05), brushing time after meals (p<0.01), oral hygiene devices (p<0.01), and yellow chroma ($b^*$) to brushing time after meals (p<0.01), subjective tooth color (p<0.001). 3. Brightness ($L^*$) of eating habit attributes was different according to coke, candy ($R^2=0.053$, p<0.05). In conclusion, this study demonstrates that the color of maxillary anterior teeth has differences in brightness ($L^*$), red chroma ($a^*$), yellow chroma ($b^*$) from each tooth, also these showed various tendency according to the oral health and eating habit attributes.

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel, undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesiodistally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference in fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even if that portion consists of mainly enamel and a little dentin structure.