• Title/Summary/Keyword: 심미적

Search Result 1,816, Processing Time 0.033 seconds

A STUDY ON THE EFFECTS OF FINISHING/POLISHING TIMING ON SURFACE FEATURES OF COMPOSITE RESTORATION (연마시기에 따른 복합레진의 표면 특성에 관한 연구)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Park, Eun-Hae;Lee, Young-Jun;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2004
  • Proper finishing/polishing of dental restorations are critical clinical procedures that enhance both esthetics and longevity of restored teeth. This study was to compare the effects of immediate and delayed finishing/polishing procedures on the surface roughness and surface hardness of tooth-colored restoratives including two microfilled composite resins, such as Filtek A110 and Silux Plus, two hybrid composite resins, such as Revolution formular2 and Palfique Estelite. A total of 48 specimens were made for each material. The first 16 specimens served as the control group and the remaining 32 specimens were randomly divided into two equal groups. The control group was stored in distilled water at $37^{\circ}C$ for 1 week after light polymerization against the Mylar sheet. The first experimental group was finished/polished immediately after light polymerization and stored for 1 week in distilled water at $37^{\circ}C$, whereas the while the second group was finished/polished 1 week after light polymerization and stored in distilled water at $37^{\circ}C$. The results were as follows: 1. The smoothest surface was produced by Mylar sheet and finishing/polishing procedure increased the surface roughness. However, the surface roughness of composite resins were not influenced by the finishing/polishing timing. 2. There were significant differences about surface roughness between Revolution formular 2 and Silux Plus, regarding immediate finishing/polishing, and between Palfique Estelite and Silux Plus regarding delayed finishing/polishing(p<0.05). 3. The sequence of the surface hardness was ascending order by Revolution formular 2, Silux Plus, Filtek A110 and Palfique Estelite. However there were no significant differences about hardness among the control group and two finishing/polishing timing groups. 4. The effects of finishing/polishing time on surface roughness and hardness appeared to be material-dependent.

  • PDF

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.

CHEMICAL DEGRADATION OF VARIOUS COMPOMERS IN NaOH (콤포머의 NaOH 용액 내에서의 화학적 분해)

  • Park, Mi-Ran;Choi, Nam-Ki;Lee, Young-Jun;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.144-152
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation of three commercial compomers in an alkaline solution. Dyract(Dentsply), Elan(Kerr) and F-2000(3M) polyacid modified resin composites(compomers) were used in this study. The resistance to degradation was evaluated on the basis of mass loss(%), degradation $depth({\mu}m)$ and Si, Al, Ba loss(ppm). The results were as follows : 1. The mass loss of each brand was $1.42%{\sim}2.14%$ and there was no statistically significant difference of mass loss among Dyract, F2000 and Elan. 2. The degradation layer depth of each brand was $182.92{\sim}227.7{\mu}m$ and there was no statistically significant difference of degradation layer depth among Dyract, F2000 and Elan. 3. There was statistically significant differences in Si-loss and Al-loss among three compomers (p<0.05). Si loss was the highest value in Dyract and Al loss was the highest value in F2000. 4. There was statistically significant correlation between mass loss and degradation layer depth (r=0.60, p<0.05). 5. In SEM finding, there was some destruction of compomer matrix-filler interface in post-exposure specimen to NaOH solution. As the matrix decreased, the filler particles distinguished and the periphery of the filler particles appeared whitish color due to degradation.

  • PDF

Anti-obesity Effects of Peucedanum japonicum Thunberg L. on 3T3-L1 Cells and High-fat Diet-induced Obese Mice (식방풍잎(Peucedanum japonicum Thunberg L.)의 물추출물이 3T3-L1 세포와 고지방식이로 유도된 마우스에서 항비만 효과)

  • Jung, Ho-Kyung;Sim, Mi-Ok;Jang, Ji-Hun;Kim, Tae-Muk;An, Byeong-Kwan;Kim, Min-Suk;Jung, Won Seok
    • Korean Journal of Plant Resources
    • /
    • v.29 no.1
    • /
    • pp.1-10
    • /
    • 2016
  • Obesity is a pro-inflammatory state that contributes to the development of metabolic disorders such as hyperlipidemia, insulin resistance, type 2 diabetes, non-alcoholic fatty liver, and cardiovascular disease. In this study, we evaluated the inhibition of adipogenesis in 3T3-L1 cells and in high-fat diet (HFD)-induced obese mice by Peucedanum japonicum Thunberg L. water extract (PJT). Lipid accumulation measurement indicates that PJT markedly inhibited adipogenesis in a dose-dependent manner. RT-PCR results demonstrated that the mRNA expression of adipogenic transcription factors such as peroxisome proliferator-activated receptor-γ (PPARγ) and CCAAT/enhancer binding protein-α (C/EBPα) in 3T3-L1 cells were significantly down-regulated by PJT treatment. Oral administration of PJT (100, 300, and 500 ㎎/㎏, b.w/daily for 4 weeks) was conducted in high-fat diet induced obese mice and C57BL/6 mice. The PJT-administered group of HFD-induced mice had a lower body weight gain, along with decreased serum levels of glucose, triglycerides, and total cholesterol compared with the control mice, however, the HDL-cholesterol/total cholesterol ratio was increased. Furthermore, the elevated mRNA expression levels of adipogenesis related genes in the white adipose tissue of obese mice were significantly suppressed by PJT. These results indicate that PJT exhibits anti-obesity effects in obese mice by decreasing in serum lipid levels and lipogenesis related gene.

A Study on the Quality of Life for the Elderly Participating Social welfare Using Facilities: Focused on the Program's Participation, Self-esteem and Depression (이용시설 참여노인의 삶의 질에 영향을 미치는 요인: 프로그램 참여도, 자아존중감 및 우울을 중심으로)

  • Jeong, Mi-Young;Sim, Mi-Young
    • 한국노년학
    • /
    • v.29 no.4
    • /
    • pp.1539-1557
    • /
    • 2009
  • The purpose of this study was to analyze the effects of program's participation, self-esteem and depression on quality of life for the elderly participating social welfare using facilities. Therefore, this paper will help improve a life's quality of all the olds by fixing the problems we got in this society and suggesting the better program for the elderly participating social welfare using facilities. The results of the study were as follows. There was no specific difference in statistic that shows the quality of the old's life who have their economic life. In quality of life in neighbors, the male were more friendly to their neighbors and the lower level of education, the higher quality of life. Healthy old people had greater quality of life than unhealthy old people did. If the old were excellent in scholarship, if unmarried couple shared the same house, if both of husband and wife live together when they are married, and if their allowance are full in pocket, the quality of their life was enhanced. Self-esteem influenced the quality of life in economic, but depression influenced negatively. In quality of life in neighbors, feeling depression and joining in program of a work for prosperity in future didn't effect doing well with the neighbors. On the other hand, participating in the social community program effected positively. In quality of life in neighbors, feeling depression and program of rehabilitation effected on the quality of life negatively. Educating refinement program effected positively being a good match, but promoting health program effected negatively.

Changes of root lengths and crestal bone height In nail biting patients (손톱 깨물기 습관을 가진 아동의 전치부 치근길이와 치조골 높이 변화에 관한 연구)

  • Hwang, Chung-Ju;Kim, Jung-Suk
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.689-698
    • /
    • 1999
  • Although the purpose of orthodontic treatment is to increase the function and aesthetics of the jaws as well as to increase stability, there are side effects from the treatment itself such as root resorption and alveolar bone resorption. Such resoiption of the apical root is unpredictable and may even proceed into the dentin layer. Once the process has begun, it is irreversible. By evaluating the effects of different oral habits, especially that ef nail biting, and their correlation with the root and the periodontal tissues, the appropriate biomechanics for orthodontic treatment can be taken into consideration. The possibility of root resorption and alveolar bone loss during orthodontic treatment can also be considered. Also, any legal problems that might occur may be pondered as well. Among the male md female patients of the ages 10~15, 63 were chosen as the test group with known nail biting habits at time of examination and within the same age range those without nail biting habits as the control group. The test group was composed of 30 males and 33 females. The control group had 31 males and 32 females. The result from this study were as follows : 1. Of the 63 patients of both the test and control groups, the male-to-female-ratio was 1:1, and had no statistically significant difference in male and female root resorption. 2. In comparing crown length of the test and control groups, no significant difference existed, but in root length, maxillary and mandibular right and left central incisors and mandibular right lateral incisors had a smaller value. (p<0.001) 3. Average crown-to-root ratio of the test group on the periapical view show a noticeably high value for the maxillary and mandibular right and left central incisors and mandibular right and left lateral incisors. (p<0.01) 4. In comparing and evaluating the alveolar bone loss measured from the cemento-enamel junction to the alveolar bone crest, mesial surfaces of the maxillary and mandibular right and left central incisors and distal surface of maxillary right central incisor of the test group showed greater loss of crestal bone than the control. (p<0.05)

  • PDF

Comparison of Olfactory Sensibility With/Without Consideration of Individual Olfactory Threshold (피험자의 후각 역치 고려 유무에 따른 후각 감성 비교)

  • Seo, Han-Seok;Jeon, Kwang-Jin;Kwon, Jin-Hwan;Hwang, In-Kyeong;Kang, Jin-Kyu;Min, Byung-Chan
    • Science of Emotion and Sensibility
    • /
    • v.10 no.2
    • /
    • pp.199-208
    • /
    • 2007
  • The olfactory function of subjects could be different due to various factors such as aging, and such discrepancies influence on the olfactory sensibility. Therefore, the objectives of this study was to investigate changes of olfactory sensibility characteristics and structure in relation to the consideration of olfactory threshold of subject. Stimulants of this study were five standard odor samples of T&T olfactometer, and thirty undergraduates over than 19 years old were tested twice during this study In experiment 1, subjects were given to odor samples which were controlled on the basis of individual olfactory threshold. Whereas, subjects were provided with uncontrolled odor samples which had the same concentration(+1) in experiment 2. Olfactory sensibility characteristics were significantly different with presentation types of odor samples, and these gaps were more higher on condition that the preference of odor sample was not distinct. Moreover, such differences affected the olfactory sensibility structure, and 'esthetic sense', 'intensity', and 'activity' were common factors, but 'friendship' of experiment 1 and 'weight' of experiment 2 were unique factors. In conclusion, the olfactory sensibility characteristics and structure could be different with consideration of olfactory threshold of subject. Overall, this study suggest that the olfactory function and the presentation method of odor sample be regarded as principal consideration factors in the olfactory sensibility evaluation.

  • PDF

A COMPARATIVE STUDY OF WATER ABSORPTION AND RELATED CHANGES OF COMPRESSIVE STRENGTH IN THREE RESTORATIVE MATERIALS (치과용 수복재의 수분흡수도와 압축강도의 변화에 관한 연구)

  • Chang, Woo-Hyuck;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.161-170
    • /
    • 2003
  • The aesthetic restorative materials are widely used in recent dentistry, showed not only the different quality between each component but also showed that the environment of the material has important effect on the physical properties of the material. Especially, when the restoratives are restored in the mouth, and since saliva is existing, the restoratives are always exposed to water and affected by the saliva. The purpose of this study was to research and compare the change of the degree of water sorption after water immersion of three types of the resin-based materials and the compressive strength, and observe the relation between the change of the water absorbing degree and the compressive strength. Z-100(3M, U.S.A) as a composite resin, F-2000(3M, U.S.A) as a compomer and Vitremer Restoratives(3M, U.S.A) as a resin-modified GIC were used, and each specimen was made to measure the water sorption and to evaluate the compressive strength. The specimens for measurement of the water sorption and the compressive strength were divided into 4 groups(1 day, 2 weeks, 4 weeks, and 8weeks). Each specimen was filled in the 30cc vial with 20cc of distilled water during the fixed amount of period in $37^{\circ}C$. The water sorption is decided by dividing the difference of weight before and after the immersion by the volume, and the compressive strength was measured by using the instron after the immersion. The following results were obtained ; 1. The more the water sorption increased, the more the immersion period of three restorative materials was long. And the most of water sorption was obtained during the first 2 weeks(P<0.001). 2. The water sorption of resin-modified GIC was higher than composite resin and compomer. 3. The more the compressive strength decreased, the more the immersion period of three restorative materials increased(composite resin and compomer: P<0.001, resin-modified GIC: P<0.05). Especially, the amount of the reduction in compressive strength of the composite resin was the highest. 4. The more the water sorption of all materials increased, the more the compressive strength decreased(P<0.05).

  • PDF

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.