• Title/Summary/Keyword: 실효값

Search Result 147, Processing Time 0.026 seconds

The study was to investigate the Spontaneous therapy, TENS and Ice therapy of Biceps brachii after induction of DOMS (자연치유와 경피신경전기자극치료, 그리고 냉치료가 지연성근육통이 유발된 위팔두갈래근의 통증과 근력 및 근활성도에 미치는 영향)

  • Kim, Keun-Jo;Lee, Cu-Rie;Jung, Byeong-Ok;Bang, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3902-3909
    • /
    • 2009
  • The purpose of this study was to investigate the spontaneous therapy, TENS(transcutaneous electrical nerve stimulation) and ice therapy after induction of DOMS(delayed onset muscle soreness) through application of eccentrically exercise in ralation to biceps brachii muscle of opposite-dominance. And to explain this, we analyzed VAS(visual analogue scales), peak torque, RMS(roots mean square) when exercising elbow joint. The subjects were 30 adults without any physical defect. Subjects were divided into three groups that spontaneous therapy, TENS therapy and ice therapy after DOMS induction, choosen movement could get the maximal peak torque in angular velocity of $60^{\circ}$/sec, and mearsured peak torque, RMS and VAS. 1. The VAS was significantly decreased after 3 days application of TENS than other groups(p<.05). 2. The peak torque was significantly increased after 3 days application of TENS than other groups(p<.05). 3. The RMS was significantly increased after 3 days application of TENS than other groups(p<.05). This study showed that TENS therapy application were effective treatment strategy on DOMS than spontaneous therapy and ice therapy. Therefore, it could be considered as a treatment method in the patients with DOMS.

An acoustic sensor fault detection method based on root-mean-square crossing-rate analysis for passive sonar systems (수동 소나 시스템을 위한 실효치교차율 분석 기반 음향센서 결함 탐지 기법)

  • Kim, Yong Guk;Park, Jeong Won;Kim, Young Shin;Lee, Sang Hyuck;Kim, Hong Kook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.1
    • /
    • pp.30-38
    • /
    • 2017
  • In this paper, we propose an underwater acoustic sensor fault detection method for passive sonar systems. In general, a passive sonar system displays processed results of array signals obtained from tens of the acoustic sensors as a two-dimensional image such as displays for broadband or narrowband analysis. Since detection result display in the operation software is to display the accumulated result through the array signal processing, it is difficult to determine the possibility where signal may be contaminated by the fault or failure of a single channel sensor. In this paper, accordingly, we propose a detection method based on the analysis of RMSCR (Root Mean Square Crossing-Rate), and the processing techniques for the faulty sensors are analyzed. In order to evaluate the performance of the proposed method, the precision of detecting fault sensors is measured by using signals acquired from real array being operated in several coastal areas. Besides, we compare performance of fault processing techniques. From the experiments, it is shown that the proposed method works well in underwater environments with high average RMS, and mute (set to zero) shows the best performance with regard to fault processing techniques.

A Study on Inset Fed Microstrip Antenna Loaded with Complementary Single Loop Resonator (CSLR을 갖는 인셋 급전 마이크로스트립 안테나에 관한 연구)

  • Hong, Jae-Pyo;Kim, Byung-Mun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.8
    • /
    • pp.921-926
    • /
    • 2014
  • In this paper, the characteristics of inset fed microstrip antenna loaded with CSLR(complementary single loop resonator) are studied. Effective permeability parameters of the SLR unit cell is retrieved from simulated scattering parameters, and structure parameters of the SLR unit cell are selected so that effective permeability is negative value at the operating frequency. The optimized inset fed microstrip antenna loaded with SLR for a $3{\times}3$ array in the ground plane of a conventional patch antenna is designed and simulation results of return loss and radiation pattern are shown. At resonant frequency 2.82 GHz, the overall dimension of the proposed antenna is reduced by approximately 56.8% compared to the conventional inset fed antenna. Simulation results are obtained by 3D FEM solver(Ansoft's HFSS).

The cutting resistance and Ae signal characteristics on cutting condition in dilling for ADI materials (ADI 재의 드릴 가공 시 가공조건에 따른 절삭저항 및 AE신호 특성)

  • 유경곤
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.6
    • /
    • pp.90-96
    • /
    • 1998
  • The ductile cast iron is austempered at 300, 350 and 40$0^{\circ}C$ temperature in order to investigate the basic factors for monitoring drill wear in automatic production process, and cutting force and AE RMS signals are measured with changing cutting condition for ADI(Austempered Ductile Cast Iron) with different mechanical properties. The signals of cutting force were influenced by cutting speed and feedrate greatly. On the other hand AE RMS signals are influenced by cutting speed where as it is not related with feedrate. As the depth of drilling increases, cutting force shows a slow increase and the value of AE RMS increases until the range of h/d=4. But over the range it increases greatly due to an amount of chip discharge and friction with inner wall of drilling hole, etc. As the drill diameter increases at a constant depth of drilling. Cutting force increases linearly, but the level of AE RMS does not increases linearly due to circumferential velocity and great influence of h/d.

  • PDF

A Study on the Establishment of Management Criteria for Underwater Noise (수중소음 관리 기준 설정을 위한 소고)

  • Lim, Dae-Kyu;Shin, Young-Cheol;Jun, Yang-Bae
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.119-132
    • /
    • 2010
  • There are many dispute with a construction due to such environment problem as vibration and noise. Generally, we have a standard for acceptance level in land. But we have not a sufficient standard for acceptance level or guide line in underwater sound. In other countries, a acceptance level or guide line in underwater sound has been suggested. Especially the management criterion of underwater noise for fish has bee suggested using the measurement data (peak pressure, rms, energy and SEL) by a hydrophone. In Korea, there is no management criterion of underwater noise for fish. This study suggested the management criteria of underwater noise for fish based on the measured data by a hydrophone.

Transformation of Measured Blasting Vibration Data to Vibration Level by Digital Filter (디지털 필터를 이용한 진동의 변환 연구)

  • Kim, Yong-Kuk;Kim, Sik;Lee, Sang-Eun;Yang, Hyung-Sik
    • Tunnel and Underground Space
    • /
    • v.10 no.3
    • /
    • pp.486-491
    • /
    • 2000
  • Blasting vibrations velocity had been used to design blasting pattern and predict damage-possibility of structures. As vibration levels are currently required to estimate the damage concerning human-body and livestock, so measured vibration velocities must be transformed into vibration levels. In this study, the digital filter program was developed to transform measured data into vibration levels. Simple harmonic vibrations and measured data obtain by Blastmate series (Instantel Inc.) were applied to the digital filter program. As a result, simple harmonic vibrations and measured data were successfully transformed into vibration levels using the developed program. Measured data from any instrument with ASCII output-function will similarly be transformed into level units.

  • PDF

Transformation of Measured Blasting Vibration Data to Vibration Level by Digital Filter (디지털 필터를 이용한 진동의 변환 연구)

  • Kim, Yong-Kuk;Kim, Sik;Lee, Sang-Eun;Yang, Hyung-Sik
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2000.09a
    • /
    • pp.241-246
    • /
    • 2000
  • Blasting vibrations velocity had been used to design blasting pattern and predict damage-possibility of structures. As vibration levels are currently required to estimate the damage concerning human-body and livestock, so measured vibration velocities must be transformed into vibration levels. In this study, the digital filter program was developed to transform measured data into vibration levels. Simple harmonic vibrations and measured data obtained by Blastmate series (Instantel Inc.) were applied to the digital filter program. As a result, simple harmonic vibrations and measured data were successfully transformed into vibration levels using the developed program. Measured data from any instrument with ASCII output-function will similarly be transformed into level units.

  • PDF

A Detection Method of Grid Voltage for Grid Support Operation of an Inverter-based Renewable Energy Generation System (인버터 기반 신재생 에너지 발전 시스템의 계통 지원 운전을 위한 계통 전압 검출 방법)

  • Ahn, Hyun-Chul;Song, Seung-Ho
    • New & Renewable Energy
    • /
    • v.9 no.2
    • /
    • pp.51-57
    • /
    • 2013
  • The Grid code is being strengthen as increase of renewable energy ratio. Especially, the grid connection regulations are continuously being updated for stable operation of power grids. Static grid support and Dynamic grid support must make an accurate measure at Grid connected point because they needs control algorithm individually. It has to exactly measure voltage including switching ripple at the output of the inverter generating system. In addition, it is necessary to have an accurate voltage measurement when the situation rapidly changing the grid impedance is caused by the input of serial impedance of transformer and line impedance as well as Grid Fault Device. In this paper, We propose a new detection method of grid voltage to calculate accurately the r.m.s voltage of the grid connection point along the standard required by the low voltage regulation. We verified performance through simulation grid fault device.

A Calculation of Effective Dose Equivalent from Data of Environmental Monitoring around the Karlsruhe Nuclear Research Center (Karlsruhe 원자력연구소 주변의 환경방사능 측정자료로부터 실효선량당량계산)

  • Lee, Chang-Woo;Lee, Jeong-Ho;Wicke, A.
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.75-85
    • /
    • 1990
  • The dose calculations were carried out using environmental montoring data around Karlsruhe Nuclear Research Center(KfK). Ingestion of plant foods was the most important pathway, and the K-40 and Pb-210 natural radioisotopes in food were the most effective radiation source to man. The dose received from artificial nuclides were mostly emitted by gamma irradiation of Cs-134 and Cs-137 deposited on the ground. The effective dose equivalent in the KfK environment was far less than the dose equivalent limit recommended by ICRP.

  • PDF

Characteristics on Arc Waveform and RMS of Current by Conductive Powder (도전성 분말에 의한 아크전류의 파형 및 실효값 특성)

  • Kim, Doo Hyun;Kang, Yang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.63-68
    • /
    • 2013
  • This paper is aimed to make an analysis on characteristics of the parallel arc waveform and RMS of current at the electrical tracking state by conductive powder. In order to achieve the goal in this paper, field state investigation at metal processing companies in Chung-Nam province area was conducted. With the field state investigation, conductive powder were collected from metal processing companies. By experiment on electrical connector(breaker, connector) over which the conductive powder were scattered, arc waveform and RMS of current were measured. The measured waveform and RMS(root-mean-square) of current were analyzed to describe characteristics and patterns of electrical arc by the conductive powder. It was proved that conductive powder on electrical connector can flow electrical current enough to make electrical fire with high thermal energy. Also the change of sine waveform and RMS of current can be used to find out relationship between electrical fire and fault signal by conductive powder. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the metal processing companies.