• Title/Summary/Keyword: 실험 영상

Search Result 10,233, Processing Time 0.044 seconds

BOLD Responses to Acupuncture on Each Side of ST36 (족삼리 좌우측 자침에 대한 BOLD 반응)

  • Yeo, Sujung;Bae, Seong-In;Choe, Ilwhan;Jahng, Geon-Ho;Lim, Sabina
    • Korean Journal of Acupuncture
    • /
    • v.31 no.1
    • /
    • pp.20-32
    • /
    • 2014
  • Objectives : There has been some controversy about the modulatory effects on brain function during acupuncture on each side of the same acupoint. This study was designed to investigate and compare the blood oxygen level-dependent(BOLD) responses of acupuncture on each side of ST36. Methods : Fourteen healthy subjects were recruited for imaging and received acupuncture or placebo stimulations either on the left or on the right acupoint of ST36 in each scan. For the voxel-wise statistical analysis, one sample T-test and the within-subject analysis of variance(ANOVA) test were performed using SPM8 software. Results : This study showed that acupuncture on each side of ST36 showed different BOLD signal patterns. Higher BOLD responses after acupuncture stimulations at the left ST36 compared to the right were observed mainly in the parahippocampal gyrus(BA 28), dorsolateral prefrontal cortex(DLPFC, BA 44), thalamus, culmen and claustrum. We investigated the different neural responses between rest and activation periods of placebo and acupuncture stimulations on each side of ST36. Acupuncture at the right ST36 elicited activation mainly in the insula, supplementary motor area(SMA) and anterior cingulate cortex(ACC), while acupuncture at the left ST36 elicited activation mainly in the insula, primary somatosensory cortex(SI, BA 2) and DLPFC(BA 44). Conclusions : To our knowledge, this is the first reported functional MRI study directly comparing when needling at the right and at the left side of ST36. This study's preliminary results proved to be evidence of acupuncture's different effects when performed on opposite sides of an acupoint.

Dynamic Traffic Assignment Using Genetic Algorithm (유전자 알고리즘을 이용한 동적통행배정에 관한 연구)

  • Park, Kyung-Chul;Park, Chang-Ho;Chon, Kyung-Soo;Rhee, Sung-Mo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.8 no.1 s.15
    • /
    • pp.51-63
    • /
    • 2000
  • Dynamic traffic assignment(DTA) has been a topic of substantial research during the past decade. While DTA is gradually maturing, many aspects of DTA still need improvement, especially regarding its formulation and solution algerian Recently, with its promise for In(Intelligent Transportation System) and GIS(Geographic Information System) applications, DTA have received increasing attention. This potential also implies higher requirement for DTA modeling, especially regarding its solution efficiency for real-time implementation. But DTA have many mathematical difficulties in searching process due to the complexity of spatial and temporal variables. Although many solution algorithms have been studied, conventional methods cannot iud the solution in case that objective function or constraints is not convex. In this paper, the genetic algorithm to find the solution of DTA is applied and the Merchant-Nemhauser model is used as DTA model because it has a nonconvex constraint set. To handle the nonconvex constraint set the GENOCOP III system which is a kind of the genetic algorithm is used in this study. Results for the sample network have been compared with the results of conventional method.

  • PDF

THE EFFECT OF LOW DIETARY CALCIUM AND IRRADIATION ON MANDIBLE IN RATS (저칼슘식이와 방사선조사가 백서 악골에 미치는 영향의 실험적 연구)

  • Lee Sun-Ki;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.229-250
    • /
    • 1993
  • This study was performed to investigate the morphological and structural changes of bone tissues and the effects of irradiation on the mandibular bodies of rats which were fed low calcium diets. In order to carry out this experiment, 160 seven-week old Sprague-Dawley strain rats weighing about 150 gm were selected and equally divided into one normal diet group of 80 rats and one low calcium diet group with the remainder. These groups were then subdivided into two groups, 40 were assigned rats for each subdivided group, exposed to radiation. The Group 1 was composed of forty non-irradiated rats with normal diet, Group 2 of forty irradiated rats with normal diet, Group 3 forty non-irradiated rats with low calcium diet, and Group 4 forty irradiated rats with low calcium diet. The two irradiation groups received a single dose of 20 Gy on the jaw area only and irradiated with a cobalt-50 teletherapy unit. The rats with normal and low calcium diet groups were serially terminated by ten on the 3rd, the 7th, the 14th, and the 21st day after irradiation. After termination, both sides of the dead rats mandible were removed and fixed with 10% neutral formalin. The bone density of mandibular body was measured by use of bone mineral densitometer(Model DPX -alpha, Lunar Corp., U.SA). Triga Mark ill nuclear reactor in Korea Atomic Research Institute was used for neutron activation and then calcium contents of mandibular body were measured by using a 4096 multichannel analyzer (EG and G ORTEC 919 MCA, U.SA). Also the mandibular body was radiographed with a soft X-ray apparatus(Hitex Co., Ltd., Japan). Thereafter, the obtained microradiograms were observed by a light microscope and were used for the morphometric analysis using a image analyzer(Leco 2001 System, Leco Co., Canada). The morphometric analysis was performed for parameters such as the total area, the bone area, the inner and outer perimeters of the bone. The obtained results were as follows: 1. In the morphometric analysis, total area and outer perimeter of the mandibular bodies of Group 3 were a little smaller than that of Group 1. The mean bone width and bone area were much smaller than that of Group 1 and the inner perimeter of Group 3 was much longer than that of Group 1. The total area and outer perimeter of Group 2 and Group 4 showed little difference. The mean bone width and bone area of Group 4 were smaller than that of Group 2 and the inner perimeter of Group 4 was longer than that of Group 2. 2. The remarkable decreases of the number and thickness of trabeculae and also the resorption of endosteal surface of cortical bone could be seen in the microradiogram of Group 3, Group 4 since the 3rd day of experiment. On the 21st day of experiment, the above findings could be more clearly seen in Group 4 than in Group 3. 3. The bone mineral density of Group 3 was lesser than that of Group 1 and the bone mineral density of Group 4 was lesser than that of Group 2 on the 7th, 14th, 21st days. The irradiation caused the bone mineral density to be decreased regardless of diet. In the case of Groups with low calcium diet, the bone mineral density was much decreased on the 21st day than on the 3rd day of experiment. 4. The calcium content in mandible of Group 3 was smaller than that of Group 1 throughout the experiment. roup 4 showed the least amount of calcium content. The irradiation caused the calcium content to be decreased regardless of diet. In the case of Groups with low calcium diet, the calcium content was much decreased on the 21st day than on the 3rd day of experiment. In conclusion, the present study demonstrated that morphological changs and decrease of bone mass due to resorption of bone by low calcium diet, and that the resorption of bone could be found in the spongeous bone and endosteal surface of cortical bone. So the problem of resorption of bone must be considered when the old and the postmenopausal women are taken radiotherapy because the irradiation seems to be accelerated the resorption of osteoporotic bone.

  • PDF

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius (자체 개발한 보조기구로 원위 요골의 골밀도 측정 자세 연구)

  • Han, Man-Seok;Song, Jae-Yong;Lee, Hyun-Kuk;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.419-426
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. Materials and Methods : CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. Results : The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. Conclusion : In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  • PDF

Physiological and Proteome Responses of Korean F1 maize (Zea mays L.) Hybrids to Water-deficit Stress during Tassel Initiation (옥수수 영양생장기 한발 스트레스에 의한 광합성의 생리적 반응 및 프로테옴 변화 분석)

  • Bae, Hwan Hee;Kwon, Young-Sang;Son, Beom-Young;Kim, Jung-Tae;Go, Young Sam;Kim, Sun-Lim;Baek, Seong-Bum;Shin, Seonghyu;Kim, Sang Gon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.4
    • /
    • pp.422-431
    • /
    • 2019
  • Severe droughts in spring have occurred frequently in Korea in recent years, exerting a critical impact on corn yield. Therefore, it is necessary to find physiological and/or molecular indicators of the response to drought stress in maize plants. In this study, we investigated the effects of water-deficit stress on two Korean elite F1 maize hybrids, Ilmichal and Gwangpyeongok, by withholding water for 10 days at tassel initiation. The water deficit drastically reduced the relative leaf water content, leaf number, leaf area, and stem length, leading to dry matter reduction. Moreover, it reduced the SPAD values and stomatal conductance of leaves in drought-stressed plants of both hybrids. Importantly, the number of leaves and SPAD value were non-destructive and easy to investigate in response to water-deficit stress, suggesting that they may be useful indicators for screening drought-tolerant genetic resources. We detected more than 100 spots that were differentially accumulated under drought stress. Of these spots, a total of 21 protein spots (≥1.5-fold) from drought-exposed maize leaves were successfully analyzed by MALDI-TOF-TOF mass spectrometry. Functional annotation using Gene Ontology analysis revealed that most of the identified proteins were involved in carbohydrate metabolism, stress response fatty acid catabolism, photosynthesis, energy metabolism, and transport. The protein expression levels were increased in both Ilmichal and Gwangpyeongok, except for triosephosphate isomerase, fructose-bisphosphate aldolase, and an uncharacterized protein. The lactoylglutathione lyase delta (3,5)-delta (2,4)-dienoyl-CoA isomerase was overexpressed in Gwangpyeongok only. The results obtained from this study suggest that the drought-specific genes may be useful as molecular markers for screening drought-tolerant maize genotypes.

A Fast 4X4 Intra Prediction Method using Motion Vector Information and Statistical Mode Correlation between 16X16 and 4X4 Intra Prediction In H.264|MPEG-4 AVC (H.264|MPEG-4 AVC 비디오 부호화에서 움직임 벡터 정보와 16~16 및 4X4 화면 내 예측 최종 모드간 통계적 연관성을 이용한 화면 간 프레임에서의 4X4 화면 내 예측 고속화 방법)

  • Na, Tae-Young;Jung, Yun-Sik;Kim, Mun-Churl;Hahm, Sang-Jin;Park, Chang-Seob;Park, Keun-Soo
    • Journal of Broadcast Engineering
    • /
    • v.13 no.2
    • /
    • pp.200-213
    • /
    • 2008
  • H.264| MPEG-4 AVC is a new video codingstandard defined by JVT (Joint Video Team) which consists of ITU-T and ISO/IEC. Many techniques are adopted fur the compression efficiency: Especially, an intra prediction in an inter frame is one example but it leads to excessive amount of encoding time due to the decision of a candidate mode and a RDcost calculation. For this reason, a fast determination of the best intra prediction mode is the main issue for saving the encoding time. In this paper, by using the result of statistical relation between intra $16{\times}16$ and $4{\times}4$ intra predictions, the number of candidate modes for $4{\times}4$ intra prediction is reduced. Firstly, utilizing motion vector obtained after inter prediction, prediction of a block mode for each macroblock is made. If an intra prediction is needed, the correlation table between $16{\times}16$ and $4{\times}4$ intra predicted modes is created using the probability during each I frame-coding process. Secondly, using this result, the candidate modes for a $4{\times}4$ intra prediction that reaches a predefined specific probability value are only considered in the same GOP For the experiments, JM11.0, the reference software of H.264|MPEG-4 AVC is used and the experimental results show that the encoding time could be reduced by 51.24% in maximum with negligible amounts of PSNR drop and bitrate increase.

The Effectiveness of Buprenorphine Transdermal Patch on Patients with Shoulder Pain: Short-Term Follow-up Study (견관절 통증을 동반한 동결견 환자에게서 Buprenorphine transdermal patch의 효과: 단기 추시 결과)

  • Hong, Jin Ho;Park, Yong Bok;Ryu, Ho Young;Jeon, Sang Jun;Park, Won Ha;Yoo, Jae Chul
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose:The effectiveness of transdermal buprenorphine patch on the patients with frozen state of frozen shoulder was evaluated. Materials and Methods: Between March and September in 2013, 127 patients with pain and limited range of motion in shoulder joint over 6 months were included. Every patient was confirmed the diagnosis through MRI or ultrasonogram and each patient received intra-articular injection of steroid once. After 2~4 weeks, every patient was interviewed via telephone survey and finally 105 patients were included, 54 patients received only oral NSAIDs (NP group) while 51 patients received additional transdermal buprenorphine patch (BP group). Pain and functional visual analog scale (PVAS, FVAS), American Shoulder Elbow Society (ASES) score was checked. Results: Generally, every outcome variables showed improvements in both groups (p<0.001). PVAS score after treatment showed superior result in NP group but it was not significant (p=0.088). In ASES score, NP group had superior result than BP group and it had significant difference. Similarly in FVAS, NP group showed superior result but the data before treatment was significantly different (p=0.028) Conclusion: Transdermal buprenorphine patch didn't show superior treatment result in the patient with frozen state of frozen shoulder which was applied with oral NSAIDs after single intra-articular glenohumeral steroid injection in short-term follow-up.

  • PDF

Assessment of Soil Aggregates and Erodibility Under Different Management Practices in the Mountainous Soils (산지에서 영농방법에 따른 토양입단과 침식성 평가)

  • Joo, Jin-Ho;Yang, Jae-E;Kim, Jeong-Je;Jung, Yeong-Sang;Choi, Joong-Dae;Yun, Sei-Young;Ryu, Kwan-Shig
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.33 no.2
    • /
    • pp.61-70
    • /
    • 2000
  • Soil erosion in the hilly and mountainous uplands in the Daekwanryong area, Kangwon-Do, were investigated through a field plot experiment. The plot size was 15m long and 2.5m wide with the average slope of 12.5 percents. Soil erodibility factor (K), surface coverage (SC), soil aggregate percentage and wind erodibility (I) were evaluated in the mountainous soils under different management practices for corn and potato cultivations. Soil erodibility factor (K) was greater in upper part than in lower part of the plots. Surface coverage (SC) values ranged from 0.01 to 0.84 depending on the amounts of crop residues. Soils having a greater crop residue in surface were less subjected to soil erosion. SC values after corn harvest were 0.4 to 0.8, while those after potato harvest were 0.4 to 0.5, indicating potato might be better than corn for erosion control. Soil aggregate percentages of the experimental plots ranged from 49.7 to 79.8%. Those were higher in potato-cultivated plots with higher surface coverage, organic fertilizer treatment and contour tillage. Soil aggregate percentage of potato-cultivated plots was significantly correlated to crop residue coverage after harvest. The dried soil aggregate percentage, showing the ranges of 26.4 to 56.4%, were higher in the plots with the increased crop residue incorporation. Wind erodibility (I) of the soil was decreased with increasing surface coverage. When soil had 26.4% of the dried aggregate percentage, wind erodibility was estimated to be $183Mgha^{-1}$ which was equivalent to soil loss of $0.5Mg\ha^{-1}day^{-1}$.

  • PDF