• Title/Summary/Keyword: 실험 데이터

Search Result 12,589, Processing Time 0.054 seconds

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Effect of Patient Size on Image Quality and Dose Reduction after Added Filtration in Digital Chest Tomosynthesis (부가필터를 적용한 디지털 흉부단층합성검사에서 환자 체형에 따른 화질 평가와 선량감소 효과)

  • Bok, Geun-Seong;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.23-30
    • /
    • 2018
  • To evaluate the effect of patient size on effective dose and image quality for Digital Chest Tomosynthesis(DTS) using additional 0.3 mm copper filtration. Eighty artificial nodules were placed in the thorax phantom("Lungman," Kyoto Kagaku, Japan), and Digital Chest Tomosynthesis(DTS) images of the phantom were acquired both with and without added 0.3 mm Cu filtration. To simulate patients of three sizes: small, average size and oversize, one or two 20-mm-thick layer of PMMA(polymethyl methacrylatek) blocks were placed on the phantom. The Effective dose was calculated using Monte Carlo simulations. Two evaluations of image quality methods have been employed. Three readers counted the number of nodules detected in the lung, and the measured contrast-to-noise ratios(CNRs) were used. Data were analyzed statistically. The ED reduced $26{\mu}Sv$ in a phantom, $33{\mu}Sv$ in one 20-mm-thick layer of PMMA block placed on the phantom, and $48{\mu}Sv$ in two 20-mm-thick layer of PMMA blocks placed on the phantom. The Effective dose(ED) differences between DTS with and without filtration were significant(p<0.05). In particular, when we used two 20-mm-thick layer of PMMA blocks placed on the phantom, the ED was significantly reduced by 36% compared with those without additional filtration. Nodule detection sensitivities were not different between with and without added filtration. Differences of CNRs were statistically insignificant(p>0.05). Use of additional filtration allows a considerable dose reduction during Digital Chest Tomosynthesis(DTS) without loss of image quality. In particular, additional filtration showed outstanding result for effective dose reduction on two 20-mm-thick layer of PMMA blocks placed on the phantom. It applies to overweight patients.

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.

A Search of the Community between Eight Constitution Medicine and Disease Ecology: A Perspective from Medical Geography (8체질의학과 질병생태학의 공통성에 관한 연구: 의료지리학적 접근을 중심으로)

  • Kim, Changkeun;Ryu, Je-Hun;Kim, Younghoon;Park, Sookyung;Jang, YoungHun;Han, JungHoon
    • Journal of the Korean Geographical Society
    • /
    • v.49 no.6
    • /
    • pp.897-916
    • /
    • 2014
  • There is a considerable community between Eight Constitution Medicine and disease ecology in that they examine the relationship between humans and environment in terms of genetic, environmental and cultural factors, in addition to the factor of germs. In this respect, the purpose of this research aims to investigate the community between Eight Constitution Medicine, a branch of Eastern Medicine and disease ecology in geography. The research method is to analyse the clinical results from 647 patients and the data from a field survey on the Yeonggwang-gun County, Jeollanam-do Province. The results are summarized as the following: First, geographical distribution of patients varies depending on the type of physical constitution; it is also divided into two types, an oceanic type and an inland type. Second, it is highly probable that there is a significant relation between a vulnerable disease in association with a type of physical constitution and patient's native place; there are diseases that are not associated with all the patients who have the same constitution; they might be incurred by the eating or life habits in association with the characteristics of geographical environment. Third, the case study of Yeonggwang-gun County, Jeollanam-do Province, with a focus on the mutual relationship among the three factors. shows that patients, who share in common the eating or life habits that coincide with their own personal types of constitution, maintain a good health condition; if not, they tend to be exposed to a various kinds of disease. Because the study on the community between Eight Constitution Medicine and disease ecology is now at the early stage, diverse types of approaches should be tried to be applied in the future.

  • PDF

Growth of Minuartia laricina, Arenaria juncea, and Corydalis speciose in Field with Various Soil Water Contents (토양 수분 함량에 따른 너도개미자리, 벼룩이울타리, 산괴불주머니의 노지 생육)

  • Gil, Min;Kwon, Hyuck Hwan;Kwon, Young Hyun;Jung, Mi Jin;Kim, Sang Yong;Rhie, Yong Ha
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.344-353
    • /
    • 2020
  • Plants native in Korea have not only ornamental values but also have excellent environmental adaptability, so they can be used as garden plants. Studies on proper volumetric water content (VWC) of substrates have been reported, but many have been conducted in glasshouse conditions where environmental factors were controlled. When considering garden planting, it is necessary to perform the automated irrigation system in outdoor conditions where rainfall occurs at frequent intervals. This research aimed to investigate the VWC suitable for the growth of Minuartia laricina, Arenaria juncea, and Corydalis speciosa in open filed. Sandy soil which consisted of particles of weathered rock was used, and the VWC of 0.15, 0.20, 0.25, and 0.30 ㎥·m-3 was maintained using an automated irrigation system with capacitance soil moisture sensors and a data logger. No significant differences in growth and antioxidant enzymes activity of A. juncea were observed among VWC treatments. However, the survival rate was low at VWC 0.30 ㎥·m-3 treatment, which was the highest soil moisture content. Even considering the efficiency of water use, we recommended that VWC 0.15-0.20 ㎥·m-3 is suitable for the cultivation of A. juncea. Minuartia laricina showed better growth with lower VWC. Because of frequent rainfall in open field, plant volume and survival rate was high even in VWC 0.15 ㎥·m-3 treatment. In C. speciosa, the plant height, number of shoots and lateral shoots, and fresh and dry weight were higher in plants grown in VWC 0.25 ㎥·m-3 as compared with that in the plants grown at 0.15, 0.20, and 0.30 ㎥·m-3. Based on these results, M. laricina needed less water in open filed, and A. juncea and C. speciosa required higher VWC, but excessive water should be avoided.

Analysis of growth environment for precision cultivation management of the oyster mushroom 'Suhan' (병재배 느타리버섯 '수한'의 정밀재배관리를 위한 생육환경 분석)

  • Lee, Chan-Jung;Lee, Sung-Hyeon;Lee, Eun-Ji;Park, Hae-sung;Kong, Won-Sik
    • Journal of Mushroom
    • /
    • v.16 no.3
    • /
    • pp.155-161
    • /
    • 2018
  • In this study, we analyze the growth environment using smart farm technology in order to develop the optimal growth model for the precision cultivation of the bottle-grown oyster mushroom 'Suhan'. Experimental farmers used $88m^2$ of bed area, 2 rows and 5 columns of shelf shape, 5 hp refrigerator, 100T of sandwich panel for insulation, 2 ultrasonic humidifiers, 12 kW of heating, and 5,000 bottles for cultivation. Data on parameters such as temperature, humidity, carbon dioxide concentration, and illumination, which directly affect mushroom growth, were collected from the environmental sensor part installed at the oyster mushroom cultivator and analyzed. It was found that the initial temperature at the time of granulation was $22^{\circ}C$ after the scraping, and the mushroom was produced and maintained at about $25^{\circ}C$ until the bottle was flipped. On fruiting body formation, mushrooms were harvested while maintaining the temperature between $13^{\circ}C$ and $15^{\circ}C$. Humidity was approximately 100% throughout the growth stage. Carbon dioxide concentration gradually increased until 3 days after the beginning of cultivation, and then increased rapidly to approximately 2,600 ppm. From the 6th day, $CO_2$ concentration was gradually decreased through ventilation and maintained at 1,000 ppm during the harvest. Light was not provided at the initial stage of oyster mushroom cultivation. On the $3^{rd}$ and $4^{th}$ day, mushrooms were irradiated by 17 lux light. Subsequently, the light intensity was increased to 115-120 lux as the growth progressed. Fruiting body characteristics of 'Suhan' cultivated in a farmhouse were as follows: Pileus diameter was 30.9 mm and thickness was 4.5 mm; stipe thickness was 11.0 mm and length was 76.0 mm; stipe and pileus hardness was 0.8 g/mm and 2.8 g/mm, respectively; L values of the stipe and pileus were 79.9 and 52.3, respectively. The fruiting body yield was 160.2 g/850 ml, and the individual weight was 12.8 g/10 unit.

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.

Study of the UAV for Application Plans and Landscape Analysis (UAV를 이용한 경관분석 및 활용방안에 관한 기초연구)

  • Kim, Seung-Min
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.3
    • /
    • pp.213-220
    • /
    • 2014
  • This is the study to conduct the topographical analysis using the orthophotographic data from the waypoint flight using the UAV and constructed the system required for the automatic waypoint flight using the multicopter.. The results of the waypoint photographing are as follows. First, result of the waypoint flight over the area of 9.3ha, take time photogrammetry took 40 minutes in total. The multicopter have maintained the certain flight altitude and a constant speed that the accurate photographing was conducted over the waypoint determined by the ground station. Then, the effect of the photogrammetry was checked. Second, attached a digital camera to the multicopter which is lightweight and low in cost compared to the general photogrammetric unmanned airplane and then used it to check its mobility and economy. In addition, the matching of the photo data, and production of DEM and DXF files made it possible to analyze the topography. Third, produced the high resolution orthophoto(2cm) for the inside of the river and found out that the analysis is possible for the changes in vegetation and topography around the river. Fourth, It would be used for the more in-depth research on landscape analysis such as terrain analysis and visibility analysis. This method may be widely used to analyze the various terrains in cities and rivers. It can also be used for the landscape control such as cultural remains and tourist sites as well as the control of the cultural and historical resources such as the visibility analysis for the construction of DSM.

Design of a Crowd-Sourced Fingerprint Mapping and Localization System (군중-제공 신호지도 작성 및 위치 추적 시스템의 설계)

  • Choi, Eun-Mi;Kim, In-Cheol
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.9
    • /
    • pp.595-602
    • /
    • 2013
  • WiFi fingerprinting is well known as an effective localization technique used for indoor environments. However, this technique requires a large amount of pre-built fingerprint maps over the entire space. Moreover, due to environmental changes, these maps have to be newly built or updated periodically by experts. As a way to avoid this problem, crowd-sourced fingerprint mapping attracts many interests from researchers. This approach supports many volunteer users to share their WiFi fingerprints collected at a specific environment. Therefore, crowd-sourced fingerprinting can automatically update fingerprint maps up-to-date. In most previous systems, however, individual users were asked to enter their positions manually to build their local fingerprint maps. Moreover, the systems do not have any principled mechanism to keep fingerprint maps clean by detecting and filtering out erroneous fingerprints collected from multiple users. In this paper, we present the design of a crowd-sourced fingerprint mapping and localization(CMAL) system. The proposed system can not only automatically build and/or update WiFi fingerprint maps from fingerprint collections provided by multiple smartphone users, but also simultaneously track their positions using the up-to-date maps. The CMAL system consists of multiple clients to work on individual smartphones to collect fingerprints and a central server to maintain a database of fingerprint maps. Each client contains a particle filter-based WiFi SLAM engine, tracking the smartphone user's position and building each local fingerprint map. The server of our system adopts a Gaussian interpolation-based error filtering algorithm to maintain the integrity of fingerprint maps. Through various experiments, we show the high performance of our system.

Noise-robust electrocardiogram R-peak detection with adaptive filter and variable threshold (적응형 필터와 가변 임계값을 적용하여 잡음에 강인한 심전도 R-피크 검출)

  • Rahman, MD Saifur;Choi, Chul-Hyung;Kim, Si-Kyung;Park, In-Deok;Kim, Young-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.126-134
    • /
    • 2017
  • There have been numerous studies on extracting the R-peak from electrocardiogram (ECG) signals. However, most of the detection methods are complicated to implement in a real-time portable electrocardiograph device and have the disadvantage of requiring a large amount of calculations. R-peak detection requires pre-processing and post-processing related to baseline drift and the removal of noise from the commercial power supply for ECG data. An adaptive filter technique is widely used for R-peak detection, but the R-peak value cannot be detected when the input is lower than a threshold value. Moreover, there is a problem in detecting the P-peak and T-peak values due to the derivation of an erroneous threshold value as a result of noise. We propose a robust R-peak detection algorithm with low complexity and simple computation to solve these problems. The proposed scheme removes the baseline drift in ECG signals using an adaptive filter to solve the problems involved in threshold extraction. We also propose a technique to extract the appropriate threshold value automatically using the minimum and maximum values of the filtered ECG signal. To detect the R-peak from the ECG signal, we propose a threshold neighborhood search technique. Through experiments, we confirmed the improvement of the R-peak detection accuracy of the proposed method and achieved a detection speed that is suitable for a mobile system by reducing the amount of calculation. The experimental results show that the heart rate detection accuracy and sensitivity were very high (about 100%).