• Title/Summary/Keyword: 실증설비

Search Result 336, Processing Time 0.033 seconds

Study on the On-Board Test of After-Treatment Systems to Reduce PM-NOx in Low-Speed Marine Diesel Engine (선박용 저속디젤엔진 적용을 위한 PM-NOx 동시저감 배출저감설비 해상실증 연구)

  • Dong-Kyun Ko;Suk-Young Jeong;In-Seob Kim;Gye-Won An;Youn-Woo Nam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.5
    • /
    • pp.497-504
    • /
    • 2023
  • In this study, Selective catalytic reduction (SCR) + Diesel particulate filter (DPF) system was installed on a ship with a low-speed engine to conduct the on-board test. The target ship (2,881 gross tons, rated power 1,470 kW@240 rpm ×1) is a general cargo ship sailing in the coastal area. Drawing development, approvals and temporary survey of the ship were performed for the installation of the after-treatment system. For performance evaluation, the gaseous emission analyzer was used according to the NOx technical code and ISO-8178 method of measurement. The particulate matter analyzer used a smoke meter to measure black carbon, as discussed by the International Maritime Organization (IMO). Tests were conducted using MGO (0.043%) and LSFO (0.42%) fuels according to the sulfur content. The test conditions were selected by considering the engine rpm (130, 160 and 180). Gaseous emission and particulate matter (smoke) were measured according to the test conditions to confirm the reduction efficiency of the after treatment system. The results of NOx emission and particulate matter (smoke) revealed that reduction efficiency was more than 90%. The exhaust pressure met the allowable back pressure (less than 50 mbar). This study confirms the importance of the on-board test and the potential of SCR + DPF systems as a response technology for reducing nitrogen oxides and particulate matter.

Research about movement character of PV Inverter by distribution line impedance (선로임피던스에 의한 태양광 인버터의 동작특성에 관한 연구)

  • Jeong, Jum-Soo;Yoon, Ki-Kab
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.305-309
    • /
    • 2009
  • This paper operate with variable line impedance equipment consist of resister and reactor, when connect to 3phase induce motor present solve problem appear grid interconnection before/after about voltage transient of pv inverter through test and analysis solve problem.

  • PDF

Establishment of Test Facility for Flue Gas Treatment Technologies and Utilization (연소배가스 처리기술 평가를 위한 설비구축 및 활용방안)

  • 박성열;한근희;현주수;민병무
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.545-550
    • /
    • 2003
  • 한국에너지기술연구원에서는 국내에서 개발된 연소배가스 처리기술의 상용화를 위한 실증용 설비구축 사업이 2002년부터 2005년까지 4년 동안 정부의 지원으로 추진 중에 있다. 본 사업은 시간당 1.0톤의 석탄 연소가 가능한 순환 유동층 연소보일러 및 부대 장치를 이용하여, 10,000 Nm$^3$/hr의 연소 배가스를 공급할 수 있는 설비와 개방형 실험실을 구축함과 동시에 전문가 집단에 의한 기술지원체계를 확립하는 것이 최종 목표이다.(중략)

  • PDF

A Study on Maximum Sidewall Pressure for Underground Transmission Cables (지중송전케이블 허용측압에 관한 연구 및 기술정립)

  • Kim, Du-Jin;Lee, Ji-Yeol;Suk, Kwang-Hyun;Kim, Jae-Seung;Kim, Tai-Young;Min, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.553-554
    • /
    • 2011
  • 도심지간 대용량 전력수송을 담당하는 지중송전케이블의 설비 신뢰성 향상과 공사원가 절감을 위해 적정 포설길이의 결정과 접속함의 최적 배치가 중요하며, 이러한 시스템 설계에 있어서 허용 포설장력과 측압은 여러 중요 요소 중 하나가 된다. 특히, 허용측압 계산과정에서 적용중인 최대 측압값에 대한 실증적 검증과 건정성 확인시험을 통해 케이블 특성에 가장 적정한 값을 도출하고, 실 계통에 적용함으로서 최적 시스템 설계가 구현될 것이다. 따라서 본 연구에서는 지중송전케이블을 관로에 포설시 곡률부에서 발생하는 측압을 여러 case별로 모의할 수 있도록 실증설비를 구축하였고, 실제 작용되는 측면하중을 로드셀을 이용하여 측정하였다. 본 연구결과로 안전율을 고려한 최적의 허용측압이 결정되었으며, 이러한 허용측압의 확대를 통해 장경간 케이블 포설의 이론 정립이 가능하게 되었다.

  • PDF

The Technique of Installing Floating Photovoltaic Systems (수상태양광의 시공기술에 관한 실증연구)

  • Choi, Young-Kwan;Yi, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4447-4454
    • /
    • 2013
  • In October 2011, a commercialized 100kW class floating photovoltaic system positive plant was installed at Hapcheon dam a multi-purpose reservoir the first time ever in the nation. Floating photovoltaic system differs in water float, mooring device and underwater cable process from land photovoltaic system. As for land and building photovoltaic power generation equipments, many installation cases and skilled experiences are available, and thus installation is not difficult. However, commercial power generation floating photovoltaic system, which is attempted for the first time in the nation, requires to be designed and installed through a series of processes like technical review and verification of data by process in comparison with similar cases. The structure of floating photovoltaic system, an equipment for float photovoltaic module and other electrical equipment, is required to withstand weather environments like wind or typhoon etc and yet not affect water quality negatively, and for implementation of this system, construction efficiency and economy etc should be considered comprehensively. In this paper, the techniques of installing floating photovoltaic structure, mooring device, underwater cable, electrical equipment and remote monitoring control system are explained. The 100kW floating PV system is operating with 15% average capacity factor.

Study on the installation of Forest Fire Simulation Facility (산불 모의 실증 시험 설비 구축)

  • Lee, Won-Kyo;Choi, In-Hyuk;Lee, Sang-Yun;Noh, Hee-Won
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.361_362
    • /
    • 2009
  • 우리나라 송전선로의 위치는 대부분 산악지형에 포설되어 있어 산불 발생으로 인한 피해에 취약한 구조이다. 주로 산불에 의한 화염, 열, 연무 등 복합적인 환경 요인이 송전선로에 영향을 미치게 되며, 이로 인해 송전 선로를 구성하는 전선 및 애자를 포함한 금구류 등이 본래의 기능을 상실하게 되어 전력 공급에 문제가 발생하게 된다. 또한 산불 진화에 사용하는 물과 방재용 약재에 의해 발생하는 부가적인 송전 선로의 특성 변화 역시 잠재적인 사고 발생 요인으로 볼 수 있다. 본 논문은 이러한 산불 발생시 송전선로에 미치는 영향 및 특성 연구를 위해 산불의 특성을 살펴보고 특성을 모의하여 시험 할 수 있는 산불 모의 실증 시험 설비를 구축에 대해 설명한다.

  • PDF

Verification Experiment and Simulation of Cooling Load for a Test Space with Forced Ventilation (시험공간에 강제환기를 고려한 냉방부하의 실증실험 및 시뮬레이션)

  • Kim, Dong-Hyeok;Yoo, Ho-Seon;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.217-222
    • /
    • 2005
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8:30 to 21:00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual cooling loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Cooling loads including sensible and latent were compared between by experiment and by simulation. Both of cooling loads associated with ventilation show a close agreement within an engineering tolerance.

  • PDF

Operation Control Algorithm of Stand-alone Power System (독립형 발전 시스템의 운전제어 알고리즘)

  • Jone, Byoungjeen;Kwon, Kyoungmin;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.63-65
    • /
    • 2013
  • 본 논문은 한국전력공사의 상용 계통 전원을 공급 받기 어려운 도서지역에 신재생 에너지를 활용한 전력 공급 발전 설비 구축을 위한 운전제어 알고리즘 제안하였다. 구성된 독립형 발전 시스템 설비는 풍력 발전설비, 태양광 발전설비, 비상용 디젤 발전설비, 전력저장용 배터리, 배터리 충전장치와 이러한 구성 요소들을 통합 제어 감시를 하기 위한 EMS(Energy Management System)로 구성되었다. 본 논문에서는 이러한 각각의 발전 설비에 대한 제어 운용 알고리즘을 제안하고, 이를 실증단지에서 적용함으로서 제안된 운용알고리즘의 적합성을 검증하였다.

  • PDF

A Study on the Development for Localization of Vibration Monitoring System for TBN and Rotor of Power Generation Facilities (발전설비 터빈 및 회전체 진동감시시스템 국산화 개발 연구)

  • Lee, Eun-Sung;Shin, Dong-Il
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.292-293
    • /
    • 2022
  • 국내발전소의 진동감시설비는 GE Bently, Nevada, VIBRO-Meter사 등 외산제품이 대부분 사용되고 있다. 본 연구에서는 부품소재 산업 국산화 시책에 부응한 발전설비 터빈 및 회전체의 진동감시시스템의 성능 검증을 실시한다. 현장 실증시험은 진동감시시스템 시제품(이하 CMS5000)과 기존 사용하고 있는 Bently3300의 측정데이터를 비교 분석하여 성능을 검증하였다. 성능 검증 결과 CMS5000은 Bently3300과 동등한 수준 이상으로 확인되어 진동감시설비의 국산화 및 수출기반 확보는 물론 예방보전 의 효율화 및 안전관리에 기여할 것으로 기대된다.

  • PDF

해외 동향

  • Korea Electrical Manufacturers Association
    • NEWSLETTER 전기공업
    • /
    • no.98-1 s.194
    • /
    • pp.19-26
    • /
    • 1998
  • PDF