• Title/Summary/Keyword: 실린더 압력

Search Result 281, Processing Time 0.024 seconds

Pressure Loss across Tube Bundles in Two-phase Flow (2상 유동 내 관군에서의 압력 손실)

  • Sim, Woo Gun;Banzragch, Dagdan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.181-189
    • /
    • 2016
  • An analytical model was developed by Sim to estimate the two-phase damping ratio for upward two-phase flow perpendicular to horizontal tube bundles. The parameters of two-phase flow, such as void fraction and pressure loss evaluated in the model, were calculated based on existing experimental formulations. However, it is necessary to implement a few improvements in the formulations for the case of tube bundles. For the purpose of the improved formulation, we need more information about the two-phase parameters, which can be found through experimental test. An experiment is performed with a typical normal square array of cylinders subjected to the two-phase flow of air-water in the tube bundles, to calculate the two-phase Euler number and the two-phase friction multiplier. The pitch-to-diameter ratio is 1.35 and the diameter of cylinder is 18mm. Pressure loss along the flow direction in the tube bundles is measured with a pressure transducer and data acquisition system to calculate the two-phase Euler number and the two-phase friction multiplier. The void fraction model by Feenstra et al. is used to estimate the void fraction of the two-phase flow in tube bundles. The experimental results of the two phase friction multiplier and two-phase Euler number for homogeneous and non-homogeneous two-phase flows are compared and evaluated against the analytical results given by Sim's model.

Dewatering of Soybean Milk Residue by Hydraulic Press with Ohmic Heating (Ohmic Heating을 이용한 두유박의 압착탈수)

  • Cho, Won-Il;Pyun, Yu-Ryang;Lee, Youn-Soo;Kwon, Ik-Boo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.324-329
    • /
    • 1996
  • In order to develop a novel dewatering process for soybean milk residue, hydraulic press with ohmic heating was built and its expression conditions were examined. The electric conductivity of raw soybean milk residue was 0.128 S/m and increased linearly with increasing temperature. Water content of the residue could be reduced to 74% with the conventional hydraulic press, but to less than 70% by applying ohmic heating to the hydraulic press. The most effective dewatering was achieved by applying alternative current with 5 kHz frequency at 60 V during expression. The solid content of the expressed liauid was markedly reduced from 10% to 3.3% by ohmic heating during expression. Temperature of the cake rose to above $95^{\circ}C$ during the dewatering due to ohmic heating.

  • PDF

Long-term Monitoring System for Ship's Engine Performance Analysis Based on the Web (선박엔진성능분석용 웹기반 장기모니터링시스템 구현)

  • Kwon, Hyuk-Joo;Yang, Hyun-Suk;Kim, Min-Kwon;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.483-488
    • /
    • 2015
  • This paper implements a long-term monitoring system (LMS) for ship's engine performance analysis (SEPA) based on the web, for the purpose of the communication speed and engine maintenance. This system is composed of a simulator, monitoring module with a multi channel A/D converter, monitoring computer, network attached storage (NAS), RS485 serial and wireless internet communication system. The existing products monitor the information transmitted from pressure sensors installed in the upper parts of each of engines in the local or web computer, but have a delay in the communication speed and errors in long-term monitoring due to the large volume of sampling pressure data. To improve these problems, the monitoring computer saves the sampling pressure data received from the pressure sensors in NAS, monitors the long-term sampling data generated by the sectional down sampling method on a local computer, and transmits them to the web for long-term monitoring. Because this method has one tenth of the original sampling data, it will use memory with small capacity, save communication cost, monitor the long-term sampling data for 30 days, and as a result, make a great contribution to engine maintenance.

Calculation of Expected Life of Hydrogen Pressure Vessels by Fracture and Fatigue Mechanics assuming Semi-elliptical Cracks and Analysis of the Effect of Thickness and Radius (반타원형 균열을 가정한 파괴 및 피로역학에 의한 수소 압력용기의 예상 수명 계산과 두께와 내경이 미치는 영향 분석)

  • Kim, Jeong Hwan;Lee, Hwa Young;Lee, Min-Kyung;Lee, Jae-Hun;Lyu, Geunjun
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.53-65
    • /
    • 2021
  • While the hydrogen refueling station is rapidly expanded and installed, the safety inspection of the hydrogen pressure vessel in the station should be very important. Of these, according to ASME, hydrogen embrittlement tests must be performed for hydrogen vessel that store hydrogen above a certain pressure. The main test method for hydrogen embrittlement inspection is to carry out fracture tests and fatigue fracture tests in a high pressure hydrogen atmosphere, which allows the durability limit of the pressure vessel to be measured and the endurable limit to be determined in the hydrogen atmosphere. In detail, the critical crack depth can be calculated by the stress intensity factor(K), and the service life can be determined by da/dN (fatigue growth rate). API579-1/ ASME FFS-1 part 9 exemplifies the calculation method according to the mode of crack-like flaws, but for various shapes such as plates and cylinders, there are about 55 modes according to the shape and location of the crack. Due to the fairly complex formula, it is not easily accessible. In this study, we will show you how to calculate fracture mechanics numerically via Excel and VBA. In addition, this was applied to analyze the effects of the thickness and inner diameter of the pressure vessel on the service life.

Turbulent-Induced Noise around a Circular Cylinder using Permeable FW-H Method (Permeable FW-H 방법을 이용한 원형 실린더 주변의 난류유동소음해석)

  • Choi, Woen-Sug;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Jung, Chul-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.752-759
    • /
    • 2014
  • Varieties of research on turbulent-induced noise is conducted with combinations of acoustic analogy methods and computational fluid dynamic methods to analyze efficiently and accurately. Application of FW-H acoustic analogy without turbulent noise is the most popular method due to its calculation cost. In this paper, turbulent-induced noise is predicted using RANS turbulence model and permeable FW-H method. For simplicity, noise from 2D cylinder is examined using three different methods, direct method of RANS, FW-H method without turbulent noise and permeable FW-H method which can take into account of turbulent-induced noise. Turbulent noise was well predicted using permeable FW-H method with same computational cost of original FW-H method. Also, ability of permeable FW-H method to predict highly accurate turbulent-induced noise by applying adequate permeable surface is presented. The procedure to predict turbulent-induced noise using permeable FW-H is established and its usability is shown.

Modelling and Simulation of H2 separation in Pd Membrane System with Co-current and Current-current Flow (병류와 향류 흐름에서 수소분리를 위한 Pd 분리막 시스템의 모델링 및 모사)

  • Yi, Yong;Noh, Seunghyo;Oh, Min
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.598-602
    • /
    • 2010
  • In this paper, we carried out CFD modelling and simulation for the membrane system to separate H2 gas from the multi-component feed gas. The membrane system is of the annulus tubular type consisting of the external lumen side for the feed gas and the internal permeation side for the sweeping gas. The operating temperature and pressure of the lumen side inlet flow are $374^{\circ}C$ and 7 bar respectively and those of the sweeping gas are $374^{\circ}C$ and 3 bar, and considering these conditions, Pd membrane system was employed. CFD simulations were performed for the co-current flow and counter-current flow membrane system based on the flow directions between the feed and the sweeping gas. Comparisons and discussions were made for the H2 partial pressure, H2 mole fraction and H2 flux for both cases. Furthermore, we executed CFD simulations for the each case of the various inlet flow rates of the feed gas at the lumen side. Accordingly, we reviewed the effects of the flow rate and residence time on the performance of the membrane system.

Implement the system of the Position Change for Obstructive sleep apnea patient (폐쇄성수면 무호흡 환자의 자세변환 시스템 구현)

  • Ye, Soo-young;Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1231-1236
    • /
    • 2017
  • In this study, we developed a system that can change position to improve obstructive sleep apnea. Blocking of the breathing airway caused by obstruction of the apnea, lateral position is provided by the airway to improve the apnea. We used a pressure sensor (FSR402) in the form of an array to determine the position of patient. The air cylinder was controlled to raise and lower the bed. As a result of calculating the pressure difference between the supine position and the lateral position, it was $0.41{\pm}0.30$ and $1.09{\pm}0.73$. In other words, when the patient is lateral position, the difference between the sensor values on the right and left side is large. Therefore, it is confirmed that the system can maintain airway to breath for improvement of obstructive sleep.

Field Application of Ultrasonic Inspection System for Stay Welds at Steam Generator of KSNP (한국표준형 원전 증기발생기 Stay 용접부 자동검사시스템 및 현장 검증)

  • Lim, Sa Hoe;Park, Chi Seung;Park, Chul Hoon;Joo, Keum Chong;Noh, Hee Chung;Yoon, Kwang Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2010
  • The stay cylinder weld at the steam generator of Korean Standard Nuclear Power Plants is safety class I component and is subjected to be inspected by the volumetric examination such as ultrasonic method. As accessibility of this area is limited due to the narrow space and high radiation, the existing manual inspection method involves various difficulties. Moreover operators may be exposed to internal contamination by contaminated dust during the surface buffing process to improve the inspection reliability of this area. Recently the new automatic inspection system for stay cylinder welds has been developed. The inspection system basically consists of a driving assembly, data acquisition device and signal processing units. The driving assembly is classified by 1) the scanner for inspecting and buffing the weld, 2) pillars for guiding the scanner and 3) the base frame for loading and supporting pillars. The scanner has 4 sensor modules to inspect in 4 refracted angles and 4 incident directions. These components can be inserted into the skirt of the stay cylinder through the manway hole and assembled easily by one-touch in the skirt. Data acquisition device and signal processing units developed in previous works are also newly upgraded for better processing of data analysis and evaluation. The system has been successfully demonstrated not only in the mock-up but also in the field. In this paper, newly developed inspection system for the stay cylinder weld of the steam generator is introduced and their field applications are discussed.

  • PDF

A Numerical Study on Effects of Pilot Injection on Combustion and Emission Characteristics in a Marine Diesel Engine (선박용 디젤 엔진에서 Pilot 분사가 연소 및 배기 특성에 미치는 영향에 관한 수치해석적 연구)

  • Bae, Myung-Jik;Han, Dong-Sik;Kim, Hyeon-Gyu;Chang, Young-Jone;Song, Ju-Hun;Jeon, Chung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.37-45
    • /
    • 2010
  • Computational simulation has been carried out to examine the effects of pilot injection to reduce both of NOx and Soot emissions in a marine diesel engine. For verification of the computational result, calculated cylinder pressure was matched to experimental pressure. In this study, the primary variables were injection timing, dwell time and injection rate while the amount of injection fuel was maintained constant. It was revealed that variation of pilot injection timing affects auto ignition and heat release rate. In the results, both of NO and soot emission were reduced without deterioration of in-cylinder pressure under the condition of $10^{\circ}$CA dwell time and 0.022kg/s injection rate.

Computational Fluid Analysis for Optimization of Vortex Cup with Different Shape (형상 변화에 따른 볼텍스 컵 최적화를 위한 전산유동해석)

  • Kim, Joong Hui;Sohn, Chang Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.8
    • /
    • pp.671-676
    • /
    • 2014
  • The vortex cup is proposed as a method to transport sensitive products such as silicon wafers in manufacturing. Air through the inlet nozzle located at the top of the vortex cup flows to form a swirl in the cylinder. The flow located in the lower part of the thin gap between the vortex cup and the bottom surface escapes and generates a negative pressure that can lift objects. In this research, three-dimensional numerical simulation of the air flow field in a vortex cup is performed, and a comparison of the simulation and experimental results shows very good agreement. In addition, the vortex cup length and shape that affect the negative pressure were applied to the analysis. Through the simulation results, optimum conditions for the vortex cup shape were proposed.