• Title/Summary/Keyword: 실대실험

Search Result 23, Processing Time 0.032 seconds

Evaluation of Thermal Environment through Large-scale Model Experiment on Air-barrier Type Perimeter-less System (실대실험에 의한 에어베리어형 페리미터레스 공조시스템의 실내 열환경 평가)

  • 김용경;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.970-978
    • /
    • 2003
  • This paper aims at suggesting design guidelines for a perimeter-less HVAC system that contributes energy savings. Perimeter-less HVAC system is one that relieves difficulties such as handling mixing loss, uneven radiative environment, and maintenance and repair. It prevents heat load gained through window and outdoor wall without modifying a previously equipped building skin system. In this paper, we conducted a large-scale model experiment to see how the push-pull air flow would handle indoor heat to obtain an optimized perimeter-less design, and then we plan to perform several kinds of CFD (computational fluid dynamics) cases through numerical simulation

An experimental study on the fire characteristics of liquid accelerant over furniture(mattress) (가구(침대)의 유류방화 특성에 관한 실험적 연구)

  • Kim, Soo-Young
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.235-240
    • /
    • 2010
  • 본 연구는 침대 매트리스를 초기 가연물로하여 소량의 인화성 액체를 사용한 방화 화재 특성에 관한 실험적 연구로서 인화성액체의 spill형태에 따른 가연물의 연소속도, 연소 Patterns의 분석과 동일한 공간 가연물에서 일반화재와 유류방화의 비교 실대 화재 실험 및 실험 현장에서 수거한 유류증거물의 인화성액체 종류별, 증거물의 상태에 따른 GC/Mass 분석 결과특성에 관한 연구이다.

  • PDF

A Study on the External Wall Heating Temperature Distribution According to Opening Size in Building (건물의 개구부 크기에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.261-267
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as following: when the experiment was conducted with opening sizes(horizontal length) each at 2,000mm, 1,600mm, and 1,400mm, the flashover occurred at 630 seconds, 505 seconds and 510 seconds, respectively. Also, the total heating time, in proportion to this, came to 815 seconds, 713 seconds and 721 seconds. The maximum heating temperature of the exterior wall by the opening size reached 282.4℃ at 2,000mm, 382.9℃ at 1,600mm, and 423.8℃ at 1,400mm. This represented that as the opening size gets smaller, the heating temperature of the exterior wall by fire spread becomes higher.

Study on Elasto-Plastic Behavior of Column to Beam Connection with 600MPa High Performance Steel(SM 570 TMC) (기둥-보 용접접합부의 보단부 스캘럽형상과 탄소성 거동에 관한 실험적 연구 - 600MPa(SM570TMC)의 경우 -)

  • Kim, Jong Rak;Kim, Seung Bae;Kwon, June Yeop
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.691-700
    • /
    • 2008
  • Contemporary architectural structures have diverse and complex forms. Such structural variety demands requisite performance from the connections in the steel structure so that the latter could resist a horizontal force, such as an earthquake. The connections are the all-important components that create the discontinuous form and that support stress concentration, determining the stiffness and toughness of the entire steel frame. In this study, a real-scale column-to-beam connection was constructed in the 600MPa-grade high-strength and high-performance steel, to test its behavior. Its material and welding characteristics were examined in this study, and its structural performance was analyzed by conducting seismic-resistance tests on the full-scale, cross-shaped column-to-beam welded connections with non-scallop, ordinary-scallop, and reinforced-scallop details. The weld ability of the high-strength, high-performance steel was also evaluated, and data regarding the seismic design for practical application were provided.

A Study on the External Wall Heating Temperature Distribution According to Opening Upper Shading Installation and Length (개구부 상부 차양설치 및 길이에 따른 외벽 수열온도분포에 관한 연구)

  • Jung, Ui-In;Hong, Sang-Hun;Kim, Bong-Joo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.339-345
    • /
    • 2020
  • This study used a real-scale model experiment to reproduce internal fires in residential buildings such as a multi-dwelling unit, in order to prevent damage caused by tens of thousands of fires witnessed each year and to take measures to cope with them. For experimental conditions, different opening sizes were applied to measure and analyze the heating temperature of the exterior wall. Results drawn are as follow : On top of this, the experimental conditions had whether to install shading and put a shading length differently, before measuring and analyzing the heating temperature of the exterior wall. Subsequent results were drawn as shown below. Based on the maximum temperature, the temperature was lowered as much as around 90℃ at 150mm, around 150℃ or over at 300mm and over 175℃ at 450mm. It also turned out that the difference in maximum temperature dropped by around 180℃ or over. This indicated that the shading installation works well in lowering flame temperature generated by fire spread of the exterior wall.

An Constructive Experiment through Mock-up and Monolith of High-Strength High-Performance Concrete (고강도-고성능 콘크리트의 모의 부재 및 실대 구조물 시공 실험)

  • 김태영;이영호;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.357-364
    • /
    • 1997
  • In this experiment high-strength concrete of good workability is made by means of either replacing unit cement quantity to fly-ash by 20% or using low heat cement to reduce the internal hydration heat suggested as the fault of concrete. Concrete is poured through ready mixed concrete to test the ability of applying to the substantial works and is carried out the test of flowing and core strength and record of temperature of imitating specimens. It is capable to apply high-strength concrete replaced to fly-adh 20% to the substantial works through the experiment

  • PDF

Fire Resistance of Concrete Filled Double Skin Tubular Columns under Axial Load (일정 축력을 받는 Double CFT기둥의 내화성능 평가)

  • Chung, Sang-Keun;Kim, Sun-Hee;Lee, Seong-Hui;Choi, Sung-Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.51-59
    • /
    • 2011
  • Although an uncoated CFT column with a high axial-force ratio can be used to secure fire resistance for two hours or less in low-rise buildings, it does not satisfy the three-hour-long fire resistance required in high-rise buildings. Accordingly, so that the uncoated CFT column could be used for high-rise buildings, additional measures for the improvement of its fire resistance should be proposed. In this regard, the use of a Double CFT column as a measure for improving the fire resistance of the uncoated CFT column was proposed in this paper. A fire resistance test was conducted on an uncoated CFT column and a Double CFT column in real scale, under a load. Through such test, the effect of the Double CFT column on fire resistance was evaluated and then compared with that of a variant shape of the cross-section of a steel column.

The Evaluation of Fire Safety Performance on Interior Finish Materials (Gypsum Board, Plywood) (건물내장재(석고보드, 합판)의 화재성능평가)

  • 김충환;김종훈;김운형;하동명;이수경
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.55-62
    • /
    • 2001
  • The fire performance evaluation methods in Korea and overseas for interior finish materials were analysed and tested with gypsum board and Plywood by using room corner test not adopted by domestic code until now. The results of gypsum board (thickness:8 mm) and Plywood (thickness:4 mm) applying NFPA 265 and ISO 9705 test respectively are satisfied the assessment criteria. To assess a actual fire performance and classify fire hazard levels for interior finish materials, room-corner test and flame spread models should be adopted in building code and fire code to overcome limitations of current bench-scale test method.

  • PDF