• Title/Summary/Keyword: 실내 이산화탄소 농도

Search Result 50, Processing Time 0.031 seconds

Effects of Green Wall System Controling Indoor Thermal Environments and Carbon Dioxide (벽면 녹화가 실내 온열환경 및 이산화탄소 농도 조절에 미치는 영향)

  • Sin, Junghwan;Kim, Hwanyi;Kim, Sughwan;Kim, Sumin;Chang, Jae D.
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.2
    • /
    • pp.148-153
    • /
    • 2014
  • Importance of energy consumptions has being emphasized because of problems of the energy and environment. So, recently, green wall systems have been installed to reduce building energy consumptions. The green wall systems provide several benefits; they make it possible to maintain moderate thermal comforts by greenery. Greening such a surface wall in the building by plants, the temperature of the wall can be properly controlled that purifies the air and improves the view spanning over the space. This study evaluated the effects of green wall systems on reducing room temperature quantitatively, changing of humidity, decreasing of $CO_2$. Test results were confirmed; first, the space installed by green walls showed that temperature and $CO_2$ decreased and humidity was increased. Second, two structures were compared with the solar radiation, and green wall systems controlled the temperature and humidity stably near the wall regardless of the amount solar radiation. In conclusion, the green wall systems can contribute to thermal comforts and indoor air quality in the buildings.

  • PDF

Characteristics of Indoor Air Quality and Local Supply Index with a Variation of Supply ${\cdot}$ Exhaust Airflow rate (환기량 변화에 따른 실내공기질과 국소급기지수 특성)

  • Han, Chang-Woo;Noh, Kwang-Chul;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.21-26
    • /
    • 2005
  • We performed the numerical analysis on the characteristics of indoor air quality and local supply index with a variation of supply · exhaust airflow rate. We analyzed the local supply index and carbon dioxide concentration at the room and breathing zone with respect to the variation of the supply · exhaust airflow rate. From the numerical results, we found that local supply index was affected but carbon dioxide concentration was hardly affected by the variation of the airflow rate in the room. And we also knew that carbon dioxide concentration was raised in despite of the increment of the supply airflow rate in the breathing zone. After this study it is necessary to analyze the local exhaust index when we evaluate the state of the ventilation in the room.

  • PDF

Plant Growth Responses and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System (벽면형 식물바이오필터 내 식물 생육 및 실내공기질 정화)

  • Jung, Seul Ki;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.28 no.5
    • /
    • pp.665-674
    • /
    • 2015
  • The final goal of this research is to develop a botanical biofiltration system, which combines green interior, biofiltering, and automatic irrigation, which can purify indoor air pollutants according to indoor space and the size of biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be more suitable for indoor space utilization. This study was performed to compare indoor air quality between the space adjacent to a botanical biofilter and the space away from the biofilter (control) without generation of artificial indoor air pollutants, and to evaluate plant growth depending on multiple floors within the biofilter. Each concentration of indoor air pollutants such as TVOCs, monoxide, and dioxide in the space treated with the biofilter was lower than that of control. Dracaena sanderiana ‘Vitoria’ and Epipremnum aureum ‘N Joy’ also showed normal growth responses regardless of multiple floors within the biofilter. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was effective for indoor air purification.

Design of multi-sensor system for comprehensive indoor air quality monitoring

  • TaeHeon Kim;SungYeup Kim;Yoosin Kim;Min Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.7
    • /
    • pp.149-158
    • /
    • 2024
  • This study aims to design and develop AirDeep-Room, a multi-sensor system for monitoring air quality in various indoor environments. The system measures CO2, TVOC, particulate matter, temperature, and humidity in real-time. By integrating multiple sensors, AirDeep-Room allows convenient correlation analysis using low data format in real-time. The sensor system was installed in a server room and a classroom. Data analysis showed a negative correlation of -0.24 between temperature and humidity in the server room, and a positive correlation of 0.43 in the classroom, indicating different interactions. A high correlation (r=0.69) between the number of students and concentrations of CO2 and TVOC demonstrated the significant impact of occupancy on air quality. AirDeep-Room effectively manages air quality across various environments and provides essential data for improving air quality in densely populated areas.

The Concentration of Indoor Air Quality and Correlations of Materials at Multiple-use Facilities in Gwangju (광주지역 다중이용시설에서 실내공기질 농도와 상관성 분석)

  • Lee, Dae-Haeng;Lee, Se-Haeng;Bae, Seok-Jin;Kim, Nan-Hee;Park, Kang-Soo;Kim, Do-Sool;Paik, Ke-Jin;Moon, Yong-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.11
    • /
    • pp.1001-1010
    • /
    • 2010
  • The purpose of this study is to investigate the concentration levels of particle materials ($PM_{10}$, asbestos), gas materials ($CO_2$, CO, $NO_2$, HCHO, Rn, VOCs) and total suspended colony (TSC), and the correlations among these materials in indoor air quality of 54 multiple-use facilities and 15 public-use facilities of Gwangju. The highest mean concentration of $PM_{10}$ was $69.2\;{\mu}g/m^3$ at indoor parking place, followed by childcare facilities, large commercial building and subway station building. The highest mean concentration of CO was 2.7 ppm at indoor parking place and that of $CO_2$ was 604.1 ppm at medical service facilities. The highest mean concentration of $NO_2$ was 0.036 ppm at indoor parking place. The geomean concentration of HCHO was $3.6\;{\mu}g/m^3$ in all facilities and the highest was $631.8\;{\mu}g/m^3$ at art gallery. The geomean concentration of VOCs (5 species) was $24.14\;{\mu}g/m^3$ in all facilities and toluene was the highest material of $15.30\;{\mu}g/m^3$, followed by xylene, ethylbenzene, benzene and styrene. The highest mean concentration of TSC was $625.3\;CFU/m^3$ at jjimjilbang, followed by childcare facilities, medical service facilities and large commercial building. The highest of asbestos was 0.0072 each/cc at childcare facilities and that of radon was 1.41 pCi/L at art gallery. PM10 showed positive correlations to TSC with $R^2\0.5332$ by lognormal equation at childcare facilities. CO2 showed positive correlations to CO at childcare facilities and indoor parking place. Lognormal equation fitted to the VOCs data more than normal equation in all facilities.

A Comparative Analysis on Concentration of Pollutants in Housing Indoor-Air between Winter and Summer (주택 실내 공기중 오염물질 농도의 동절기와 하절기 비교 분석)

  • Nam, Ki-Cheul;Lee, Young-Han;Choi, Bong-Seok
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.125-131
    • /
    • 2017
  • Purpose: The study is to measure concentrations of indoor air pollutants in housing and to analyze the characteristics of pollutants in housing indoor-air between summer and winter comparatively. The research result could be used as data for public health through indoor air quality management of existing housing and more as a reference for new housing. Method: It was investigated 24 middle class housings of metropolitan area in winter which have been built for the past 30 years. Concentration of HCHO, TVOC was investigated in living room at morning and night and concentration of $CO_2$ was investigated in living room and master bedroom at morning and night. SKT100-X5 was used for concentration of HCHO, TVOC and ZGm053UK for concentration of $CO_2$. The characteristics of HCHO, TVOC, $CO_2$ concentration in winter were analyzed and then the concentrations in winter were analyzed the concentrations in summer being preceding research comparatively. Result: Average concentration of TVOC in winter was 2.7 times more than that of TVOC in summer, average concentration of HCHO in winter was about 2.0 times more than that of HCHO in summer. Average concentration of $CO_2$ in the morning at living room in winter was 1.3 times more than that of $CO_2$ in summer. Average concentration of $CO_2$ in the morning at master bedroom in winter was 1.1 times more than that of $CO_2$ in summer. Average concentration of TVOC was 1.31 times more than that of HCHO and standard deviation of that was 1.73 times higher. Average concentration of $CO_2$ was almost nearly close or over to 1,000ppm being criteria of the Ministry of Environment.

Development of Potassium Impregnated Carbon Absorbents for Indoor CO2 Adsorption (K계열 함침 탄소계 흡착제의 실내 저농도 이산화탄소 흡착성능 강화)

  • Jeong, Se-Eun;Wang, Shuang;Lee, Yu-Ri;Won, Yooseob;Kim, Jae-Young;Jang, Jae Jun;Kim, Hana;Jo, Sung-ho;Park, Young Cheol;Nam, Hyungseok
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.606-612
    • /
    • 2022
  • Relatively high indoor CO2 concentration (>1,000 ppm) has a negative impact on human health. In this work, indoor CO2 adsorbent was developed by impregnating KOH or K2CO3 on commercial activated carbon, named as KOH/AC and K2CO3/AC. Commercial activated carbon (AC) showed relatively high BET surface area (929 m2/g) whereas KOH/AC and K2CO3/AC presented lower BET surface area of 13.6 m2/g and 289 m2/g. Two experimental methods of TGA (2,000 ppmCO2, weight basis) and chamber test (initial concentration: 2,000 ppmCO2, CO2 IR analyzer) were used to investigate the adsorption capacity. KOH/AC and K2CO3/AC exhibited similar adsorption capacities (145~150 mgCO2/g), higher than K2CO3/Al+Si supports adsorbent (84.1 mgCO2/gsample). Similarly, chamber test also showed similar trend. Both KOH/AC and K2CO3/AC represented higher adsorption capacities (KOH/AC: 93.5 mgCO2/g K2CO3/AC: 94.5 mgCO2/gsample) K2CO3/Al+Si supports. This is due to the KOH or K2CO3 impregnation increased alkaline active sites (chemical adsorption), which is beneficial for CO2 adsorption. In addition, the regeneration test results showed both K-based adsorbents pose a good regeneration and reusability. Finally, the current study suggested that both KOH/AC and K2CO3/AC have a great potential to be used as CO2 adsorbent for indoor CO2 adsorption.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Evaluating the Feasibility of a Ground Source Heat pump System for an Elderly Care Center through Simulation Approach (시뮬레이션을 통한 노인 요양 시설의 지열 히트펌프 시스템 적용 가능성 평가)

  • Byonghu Sohn;Young-Sun Kim;Seung-Eon Lee
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.4
    • /
    • pp.39-52
    • /
    • 2023
  • This study analyzes the energy performance of a elderly care center building and the applicability of a ground source heat pump (GSHP) system through simulation approach. For this purpose, a building information modeling (BIM) program and an energy performance calculation program were used. The impact of the mechanical ventilation system on the energy requirements of the heating and cooling system and the indoor environment was also analyzed, focusing on the change in indoor carbon dioxide (CO2) concentration, which is a representative indicator of the indoor environment (air quality). The simulation results showed that the target building exceeds Level 7 in terms of simulated primary energy consumption or actual energy consumption. In addition, it was analyzed that the target building could not maintain the indoor CO2 concentration below the standard concentration by natural ventilation through window opening alone. Combining the GSHP system with the mechanical ventilation system (Case B and Case C) can further reduce the overall energy consumption by reducing the amount of outdoor air introduced by opening windows. The cost savings compared to the baseline case are estimated to be 67.3% for Case A, 63.7% for Case B, 65.5% for Case C, and 42.5% for Case D. It is necessary to analyze the impact of various renewable energy technologies and passive ones on the energy performance and indoor environment of elderly care centers.

Intercomparison of Chamber Methods for Soil Respiration Measurement in a Phytotron System (식물 환경 조절 시스템에서의 토양 호흡 관측 챔버법의 비교 실험)

  • Chae Namyi;Kim Rae-Hyun;Hwang Taehee;Suh Sang-Uk;Lee Jae-Seok;Son Yowhan;Lee Dowon;Kim Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.7 no.1
    • /
    • pp.107-114
    • /
    • 2005
  • Soil CO₂ emission is one of the primary components in carbon balance of terrestrial ecosystems. In soil CO₂ flux measurements, chamber method is currently the most common technique. Prior to compare or synthesize the data collected from different chamber methods, potential biases must be quantified for each measurement system. We have conducted an intercomparison experiment among four closed dynamic chamber systems and an automatic open-closed chamber system in a temperature-controlled phytotron. Due to the disturbed CO₂ concentrations inside the phytotron during the measurements with closed dynamic chambers and the changes in soil water content, the interpretation of the data was difficult to quantify the biases of individual methods. However, the experiment provided not only valuable information on the performance characteristics of the five instruments to varying soil temperature and CO₂ concentration but also useful insights for better designs and strategy for future intercomparison in a controlled environment.