• Title/Summary/Keyword: 실내 광원

Search Result 93, Processing Time 0.025 seconds

Implementation of AC Direct Driver Circuit for Ultra-slim LED Flat Light System (초슬림 LED 면조명 기구용 교류 직결형 구동 회로 구현)

  • Cho, Myeon-Gyun;Choi, Hyo-Sun;Yoon, Dal-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4177-4185
    • /
    • 2012
  • LEDs are becoming the most suitable candidate replacing traditional fluorescent lamps because of its eco-friendly characteristics. LEDs are also actively used to design green building system and to make outdoor billboard as a back-light system due to its high energy efficiency. In this paper, we have developed AC direct driver for $12{\times}12$ FLB(flexible LED board) and LED flat light without SMPS. It has LID-PC-R101B driver IC that can support the high power factor and be composed of LED switching circuit in group. Also, an elaborate system designs can guarantee a high luminous efficiency, a high reliability and a low power consumption. The proposed FLB has the ultra slim shape of $450{\times}450$ mm, width of 4 mm and weight of 280 g. In the end, we have developed a prototype of FLB for billboard and flat light for room lighting with AC direct driver iposrder to verify the performance of the proposed system.

EEFL using intelligent lighting system control device (EEFL을 이용한 지능형 조명시스템 제어장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.11 no.4
    • /
    • pp.229-234
    • /
    • 2013
  • The purpose of this study is to develop a lighting apparatus of the illuminance and color temperature to maximize the ability of the optimal combination of light sources that can be controlled efficiently control device. Finding people comfortable feeling for indoor lighting that can be used in a variety of color temperature illumination area by combining light sensitivity can be realized. Lighting apparatus for fluorescent lamps with different color temperature of 2000K and 8000K, and by varying the quantity of each of the fluorescent lamps, the illuminance of lighting equipment and color temperature through optical simulations were evaluated. By infrared remote control receiver, divided into 5 types of relaxation, conversation, meeting, hospitality, arts and the lighting environment you want to transfer the PC0 ~ PC4 through the parallel port on the mode selected by the user at the receiving end the DC voltage output. EEFL inverter input DC voltage and the DC input voltage, depending on the level of EEFL dimming value (illuminance and color temperature) lighting environment you want to create change while using a PIR sensor EEFL automatically turn off if people do not have was developed so that the power consumption so you can save.

Study on Scalable Video Coding Signals Transmission Scheme using LED-ID System (LED-ID 시스템을 이용한 SVC 신호의 전송 기법에 관한 연구)

  • Lee, Kyu-Jin;Cha, Dong-Ho;Hwang, Sun-Ha;Lee, Kye-San
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.10B
    • /
    • pp.1258-1267
    • /
    • 2011
  • In this paper, using the indoor LED-ID communication system have researched for how to transmit video signals. In LED-ID communications use the LEDs for lighting features at the same time communication is an effective way to implement. This proposed system using Visible light(RGB) as way to transmit signals, depends on the mixture RGB, which decided the color of light, moreover, each things determined their performance. However, if the video signal were fixed allocated RGB to transmit such as the original system, the importance of the each signals a different occur the limit on the quality of the video than SVC signals. In order to solve this problem in this paper, according to the RGB mixture ratios analyze the performance for the White LED, which analyzed based on allocating the SVC signal by transmitting to improve the quality of the video was about how researched.

A Study on Ubiquitous Road for Prevention of the Overweight Vehicles (과적차량 방지를 위한 유비쿼터스도로에 관한 연구)

  • Jo, Byung-Wan;Yoon, Kwang-Won;Park, Jung-Hoon;Kim, Heoun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.225-232
    • /
    • 2008
  • Overload vehicles operate damage to road, bridge, and then increasing in maintenance and repair cost because structures are reduced durability. The existing regulation systems have many problems and need coping measure. Therefore, this paper organized Ubiquitous sensor network system for development of intelligent auto overload vehicle regulation system about high speed vehicles, also axial load WIM sensor was selected by indoor experiment through wireless protocol. And we examined possibility U-load auto overload vehicle regulation system through experiment of the transmission and reception distance. If this system will apply to road and bridge, might be effective for economy and convenience through establishment of U-IT system. And high speed vehicle that was amalgamate IT technology and existing overload regulation problems, also tested wireless sensor for USN organization. This experiment aim to organize system interface for user through perfection man-less, wireless system of Internal/External Network from high speed WIN sensor with USN organization. Accordingly, it is necessary experimentation through Test Bed for constitution External network and application of actually regulations using WCDMA/HSDPA.

Study of the Optical System Design of a Reflective LED Stand to Reduce Glare (눈부심 감소를 위한 반사형 LED 스탠드 광학계 설계에 관한 연구)

  • Kong, Mi-Seon;Jung, Mee-Suk
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.334-343
    • /
    • 2020
  • In this paper, a study of the design of a lighting optical system to form indirect light was conducted, to reduce the glare caused by the hot spot of the LED. In the case of using an LED for indoor lighting, glare is caused because of the high luminance and non-uniform luminance distribution. In particular, LED stands are located close to the user's eyes and are used for a long time, so research to reduce glare is essential. Therefore, in this paper an optical system structural study and the design of an LED stand for glare reduction were conducted. Afterward, the luminance analysis and comparison to an existing LED stand product confirmed that the reflective LED stand proposed in this paper had better performance in terms of glare.

Effects of Indoor Light Intensity on the Growth Characteristics of $Distylium$ $racemosum$, $Osmanthus$ $heterophyllus$ and $Damnacanthus$ $indicus$ (실내 광조건이 조록나무, 구골나무 및 호자나무의 생육에 미치는 영향)

  • Song, Eun-Young;Kim, Seong-Cheol;Chun, Seung-Jong;Lim, Chan-Kyu;Kim, Mi-Sun;Kim, Chun-Hwan;Ro, Na-Young
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.66-73
    • /
    • 2012
  • This study was conducted to develope new indoor plants and to investigate the effects of light intensity on the growth of $Distylium$ $racemosum$, $Osmanthus$ $heterophyllus$ and $Damnacanthus$ $indicus$ under 100 lux, 1,000 lux and 2,500 lux fluorescent lighting for six months in the environment-controlled growth chambers. 1. $Distylium$ $racemosum$ : Most of $Distylium$ $racemosum$ under 100 lux light intensity were blighted in two months, whereas it was 100% of survival under 1,000 lux and 2,500 lux after six months. Plant height, number of leaf, leaf width and leaf length became higher as light intensity increased. The plants maintained under 2,500 lux showed the greatest plant height and leaf number. 2. $Osmanthus$ $heterophyllus$ : $Osmanthus$ $heterophyllus$ under 100 lux light intensity were blighted in two months, whereas it was 100% of survival under 1,000 lux and 2,500 lux after six months. However, under 1,000 lux, it paused plant height and was not increased in leaf number any more. A plant growth status showed the highest value under 2,500 lux in all conditions. 3. $Damnacanthus$ $indicus$ : $Damnacanthus$ $indicus$ was defoliated and blighted under 100 lux light intensity in two months, whereas it was grown properly with 1,000 lux or above. However, the growth under 2,500 lux of $Damnacanthus$ $indicus$ was superior to other treatments. But, $Damnacanthus$ $indicus$ under 1,000 lux after 6 months was more favorable chlorophyll contents, leaf length and leaf width than 2,500 lux. As increasing slightly of chlorophyll contents and leaf growth under 1,000 lux, $Damnacanthus$ $indicus$ could be utilized highly to the indoor ornamental plant.

In vitro Test of Mycelial Growth Inhibition of 5 Fungi Pathogenic to Strawberries by Ultraviolet-C (UV-C) Irradiation (자외선(UV-C) 조사에 의한 딸기병원균의 균사생장억제)

  • Kim, Seon Ae;Ahn, Soon-Young;Oh, Wook;Yun, Hae Keun
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.634-637
    • /
    • 2012
  • In strawberry production, among others, the high incidence of diseases by pathogenic fungi resulting in the reduction of fruit yield and quality requires the development of eco-friendly management systems rather than chemical sprays to control them. The diameter of colonies grown in media at $25^{\circ}C$ for 5 days was measured to evaluate the in vitro inhibition of mycelial growth of 5 pathogenic fungi by irradiation with ultraviolet (UV-C, 264 nm). The mycelial growth of 5 pathogenic fungi was inhibited in potato dextrose agar (PDA) by the irradiation of UV-C for 1 hour a day, and was dramatically inhibited by the irradiation of UV-C for 9-12 h a day. The irradiation of UV-C for 9-12 h a day inhibited completely the growth of the late blight pathogen, Phytophthora cactorum. The irradiation distance of 40 to 50 cm was effective for the inhibition of mycelial growth of fungi. The mycelial growth of fungi without pre-incubation was inhibited strongly by UV-C irradiation compared to fungi pre-incubated for 2 days without light. The mycelia growth of Colletotrichum gloeosprioides and Fusarium oxysporum was inhibited strongly by UV-C irradiation in vegetable 8 juice agar compared to PDA.

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

Analysis of Eye-safe LIDAR Signal under Various Measurement Environments and Reflection Conditions (다양한 측정 환경 및 반사 조건에 대한 시각안전 LIDAR 신호 분석)

  • Han, Mun Hyun;Choi, Gyu Dong;Seo, Hong Seok;Mheen, Bong Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.5
    • /
    • pp.204-214
    • /
    • 2018
  • Since LIDAR is advantageous for accurate information acquisition and realization of a high-resolution 3D image based on characteristics that can be precisely measured, it is essential to autonomous navigation systems that require acquisition and judgment of accurate peripheral information without user intervention. Recently, as an autonomous navigation system applying LIDAR has been utilized in human living space, it is necessary to solve the eye-safety problem, and to make reliable judgment through accurate obstacle recognition in various environments. In this paper, we construct a single-shot LIDAR system (SSLs) using a 1550-nm eye-safe light source, and report the analysis method and results of LIDAR signals for various measurement environments, reflective materials, and material angles. We analyze the signals of materials with different reflectance in each measurement environment by using a 5% Al reflector and a building wall located at a distance of 25 m, under indoor, daytime, and nighttime conditions. In addition, signal analysis of the angle change of the material is carried out, considering actual obstacles at various angles. This signal analysis has the merit of possibly confirming the correlation between measurement environment, reflection conditions, and LIDAR signal, by using the SNR to determine the reliability of the received information, and the timing jitter, which is an index of the accuracy of the distance information.

Prognostic Value of Blood Lactate for Mortality of Acutely Poisoned Patients in Emergency Department (응급실내 급성 중독 환자들의 예후 예측에 대한 혈액 젖산 수치의 유용성)

  • Kim, Hye Ran;Kang, Mun Ju;Kim, Yong Hwan;Lee, Jun Ho;Cho, Kwang Won;Hwang, Seong Youn;Lee, Dong Woo
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.14 no.1
    • /
    • pp.16-25
    • /
    • 2016
  • Purpose: Patients suffering from acute poisoning by different substances often visit the emergency department (ED) and receive various prognoses according to the toxic material and patients' condition. Hyperlactatemia, which is an increased blood lactate level that generally indicates tissue hypoperfusion, is commonly utilized as a prognostic marker in critically ill patients such as those with sepsis. This study was conducted to investigate the relationships between blood lactate and clinical prognosis in acute poisoned patients. Methods: This retrospective study was conducted from January 2013 to June 2014 at a single and regional-tertiary ED. We enrolled study patients who were examined for blood test with lactate among acute intoxicated patients. The toxic materials, patient demographics, laboratory data, and mortalities were also reviewed. Additionally, we analyzed variables including blood lactate to verify the correlation with patient mortality. Results: A total of 531 patients were enrolled, including 24 (4.5%) non-survivors. Patient age, Glasgow coma scale (GCS), serum creatinine (Cr), aspartate transaminase (AST), and serum lactate differed significantly between survivors and non-survivors in the binary logistic regression analysis. Among these variables, GCS, AST, and lactate differed significantly. The median serum lactate levels were 2.0 mmol/L among survivors and 6.9 mmol/L among non-survivors. The AUC with the ROC curve and odds ratio of the initial serum lactate were 0.881 and 3.06 (0.89-8.64), respectively. Conclusion: Serum lactate was correlated with fatalities of acute poisoning patients in the ED; therefore, it may be used as a clinical predictor to anticipate their prognoses.

  • PDF