A Study on the Evaluation the Safety of Evacuation in Indoor Sports Stadium through Evacuation Simulation (피난시뮬레이션을 통한 실내 스포츠경기장 내 장애인의 피난 안전성 평가 연구)

  • MinEon Ju;SeHong Min
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.69-81
    • /
    • 2024
  • Purpose: Recently, there has been a movement to guarantee the right to watch sports for the disabled. However, the sports stadium is designed without considering the wheelchair users, so the right to move in the stadium is not secured. Restrictions on the movement of the disabled make the evacuation vulnerable in an emergency. This study aims to develop a plan to ensure the safety of movement and evacuation of wheelchair users by conducting simulations targeting indoor sports stadiums. Method: The simulation was performed by constructing a scenario with the shape of the stands as a variable. The effect of the installation of wheelchair seats on evacuation was confirmed. Result: The results according to whether wheelchair seats are installed, the evacuation route of wheelchair movement, and whether wheelchair seats are separately arranged were compared. The impact of wheelchair seat installation on evacuation and its characteristics were derived. As a result, upward and separation seat was the most vulnerable to evacuation. Conclusion: A plan to secure evacuation performance was derived for the top floors of upward and separation seat. It is judged that the content can be use as a way to secure the safety of movement and evacuation of the disabled in sports stadiums.

Economic and Evacuation Time Analysis of Horizontally-installed Indoor Emergency Exit (하향식 피난구의 경제성 및 피난 소요시간 분석)

  • Liu, Yue;Kim, Sun-Kuk;Kim, Ki-Hyuk;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.363-373
    • /
    • 2018
  • Evacuation facilities are installed so that people can evacuate high-rise apartment houses when it is impossible to escape fire through the front door. The households of apartment houses may escape the building in two ways, which will reduce loss of lives. This study examined the characteristics of two-way evacuation facilities, including a light-weight partition wall, shelter space at the balcony and horizontally-installed indoor emergency exit. Then, it proposed a horizontally-installed outdoor emergency exit that improved the problems of the examined facility types, and analyzed its economic-feasibility. When a horizontally-installed emergency exit instead of a traditional type to escape from fire is used, people may be more autonomous in deciding whether active evacuation is possible or not. Thus, the time required to evacuate the building with 4 different evacuation methods using the stairs and horizontally-installed emergency exit was simulated in consideration of the impact of evacuation methods that people choose on the time required for evacuation using pathfinder. Then, the simulation results were compared and analyzed. Any appropriate evacuation method to reduce the time required for evacuation was predicted, analyzed and decided. As a result of this study, it was analyzed that the high - rise apartment top - down type evacuation zone can shorten the total evacuation time compared to the staircase type.

An Experimental Study on Mechanical Ventilation Using an Exhaust Engine in Corridor Fires (복도공간 화재 시 배연차를 활용한 배연에 관한 실험적 연구)

  • Lee, Sung-Ryong;Han, Dong-Hoon
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.99-105
    • /
    • 2010
  • Ventilation fans utilized correctly can increase the effectiveness of fire fighters and survivability of occupants. It is possible to increase the pressure of a corridor to prevent the infiltration of smoke. In this study, experiments were carried out to evaluate ventilation effectiveness in corridor fires. Corridor used in the experiment was 20 m long. Heptane was used as a fuel. Temperature and visibility were measured in order to evaluate ventilation effectiveness according to the position of a vent. Vent distance ranged from 0 m to 4 m and height varied from 0 m to 1.5 m. When the vent was positioned 2 m long and 0.75 m high the result was most effective.

A Study on the Evacuation Planning in the Multiplex Cinema (멀티플렉스 영화관의 피난계획에 관한 연구)

  • So Eun-Tark;Song Byung-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.3 s.50
    • /
    • pp.147-155
    • /
    • 2005
  • As multiplex theaters are increasing rapidly in number, concerns over the evacuation process in case of fire emergency are also increasing. The study investigates the users' awareness and recognition of evacuation route by the method of questionnaire, and analyzes the users' behavior in choosing the route by the simulation program called Simulex. Among others, findings indicate a vast majority of the users are unaware of the proper route in the emergency, yet anticipate to evacuate by it, instead of the entry/exit route that they are familiar with. This aspect, however, can be useful to provide the proper route of evacuation for the users, if an appropriate information is given that the entry/exit route is also used as an emergency egress. The simulation shows heavy congestion at the closer evacuation route from the exit, and distinctly less traffic at the farther means of egress. Based on this natural phenomenon, it is suggested that the emergency stair should be nearby and aligned with the exit from auditorium. Although the present building regulation only requires a minimum dimension at each route, there is a need to widen the passageway that is likely to be recognized easily and subsequently overcrowded in case of fire emergency.

실내가연물의 유독가스 방출특성에 관한 연구

  • Kim, Hong;Oh, Kyu-Hyung;Lee, Young-Sub;Kim, Dong-Hyun;Ham, Sang-Geun
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.06a
    • /
    • pp.186-189
    • /
    • 2000
  • 국내의 건축물의 화재안전성 평가는 화재안전성을 고려한 공간구성, 연기의 유동, 거주자의 피난계획 및 피난성능평가, 건축물 내부에 설치된 방화설비계통의 화재안전성능평가 등을 연구하여 왔다. 그런데 이들 연구의 대부분은 건축물의 공간적 특성분석과 주거여건 등을 고려한 기초자료의 파악 및 분석 등을 국내의 여건과는 상이한 국외의 자료를 근거로 하거나 2차원적인 해석 및 평가에 그치고 있는 경향이 있다. (중략)

  • PDF

A Study on the Improvement of the Evacuation in Ward of the General Hospital (종합병원 병동부 피난환경 개선에 관한 연구)

  • Kim, Woo-Seok;Chai, Choul-Gyun
    • Korean Institute of Interior Design Journal
    • /
    • v.15 no.5 s.58
    • /
    • pp.202-208
    • /
    • 2006
  • The purpose of this study is to suggest architectural planning guideline for the improvement of the evacuation environment in a ward. To suggest of guideline, the problem of irrational domestic criteria is searched according to compare National fire code (NFPA101, Life safety code) with Korea building law. This study includes stairs, corridors and exit door etc. but excludes fire facilities. To verify effectiveness of suggested guideline, egress simulation is run that based on databases according to literature survey. The results of this study could be summarized as follow: Suggested guidelines are subdivision(fire partition), evacuation by elevator, secure useful waiting space of elevator hall and smokeproof enclosures, the corridor is divided by fire or smoke barriers corridor from hazardous room, only wheeled items are arranged in corridors of a ward story. The result of computer simulation for suggested guidelines verify that egress time can be decreased 20% or above.

Numerical Study on the Effect of Heat Release Rate and Interior Opening on Fire Flow Velocity in the Case of Interior Fire in an Apartment Building (공동주택 화재 시 화재크기 및 실내 개구부 크기가 화재풍속에 미치는 영향에 관한 수치해석적 연구)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.37-43
    • /
    • 2014
  • In the case of interior fire in an apartment building, contamination of vestibule area by fire smoke before air fan operating when fire doors are open makes the evacuation of people very difficult. In order to investigate the effect of heat release rate (HRR) and interior opening on fire flow velocity, numerical simulations using Fire Dynamics Simulator were carried out. In simulations, actual dimensions and configuration of an apartment building were considered and interior leakage and HRR were varied. From simulation results, it was found that fire flow velocity distribution is significantly influenced by HRR and interior opening resulting in the change of the location of a neutral plane. Also, it is shown that there is a larger difference of the fire flow velocity between upper and lower part of the fire door when the neutral plane becomes closer to the ceiling.

A Study on the Enhancement of Fire Resistance Function in Primary Structure Department of Building Type Traditional Market (건물형 전통시장 화재발생시 피난안전성 확보를 위한 규모별 주요구조부 내화보강 연구)

  • Jang, Hye-Min;Hwang, Jung-Ha
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.87-95
    • /
    • 2020
  • This study evaluates the safety of an asylum through a fire simulation of building Type traditional markets. We derive the building's indoor temperature, use the observed variation in temperature gradient to calculate the temperature of the main structure, and finally compares the time required to attain the limit temperature of the structure its time of escape. To ensure improved security of the asylum, the government has proposed a fire-resistance improvement plan for the major structural parts of buildings are not safe with thickness of 0.01 m and 0.035 m. F.ire-resistance reinforcement for small - and medium-sized vehicles is more than 0.025 m, in thickness; moreover safety can be ensured for medium and large-sized vehicles fire using fire resistant reinforcement of over 0.035 m. Accordingly, in order to ensure the safety of an asylum, fire-resistant reinforcement measures may be considered.

Route Exploration Algorithm for Emergency Rescue Support on Urgent Disaster (긴급 재해 발생 시 피난 지원을 위한 탈출 경로 탐색 알고리즘)

  • Hwang, Jun-Su;Choi, Young-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.9
    • /
    • pp.12-21
    • /
    • 2016
  • The emergency evacuation support system supports evacuation assistance when an urgent disaster occurs. We have implemented evacuation route search algorithm to assist people's escape when a disaster occurs such as fires or terrorism in the building. The algorithm will guide the escape route at the fastest emergency exit of each region at the emergency state. The algorithm calculates the escape route by applying the weighting factor of age groups and population density around the emergency exit and of other regions. So the system helps escape to bypass the crowded emergency exit and the disaster area, and reduces the congestion of emergency exit and overloading of evacuation route.

A Study on the Application of Fire Protection Facilities in Large Enclosure Gymnasium (대규모 실내경기장의 소방방재설비 적용현황 분석)

  • Choi, Dong-Ho;Kim, Choon-Dong;Yang, Jeong-Hoon;Cho, Young-Hum
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.135-145
    • /
    • 2010
  • The objective of this study is to draw basic data for the application of the fire protection planning for the future plan large enclosure buildings in Korea through an analysis of its characteristics by case studies of the domestic and foreign large scale gymnasiums. In this study, domestic building codes for the fire protection are investigated and fire detection systems, fire extinguishing systems, smoke control systems and evacuation systems of three large scale gymnasiums located at Korea and eight foreign countries are compared and analyzed. The results of this study show that infrared light fire detection system and flame detector for spacial characteristics are potentially used in fire protection systems of large scale gymnasiums: dry type sprinkler and sprinkler water gun are adopted in fire detection system; and smoke accumulation system is widely utilized in smoke control system.

  • PDF