• Title/Summary/Keyword: 실내토조실험

Search Result 67, Processing Time 0.028 seconds

Behavior of Underground Flexible Pipes Subject to Vehicle Load (차량하중을 받는 지중연성관의 거동특성)

  • 이대수;상현규;김경열
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.65-73
    • /
    • 2002
  • Underground flexible pipes for electric cables are subject to external loads and surrounding soil pressure. Particularly, strain of flexible pipes is of great concern in terms of safety and maintenance for electric cables. In this paper, stress and strain of flexible pipes with various depth are compared using traditional formula, FEM analysis and model soil box test. The results show that theoretical values are more conservative in strain in comparison with model soil box test and FEM analysis. Considering the strain criteria - maximum 3.5%, flexible pipes can be buried at the depth of 40cm without additional soil improvement. From the result of this study, deformation formula compatible with the field condition was proposed.

Laboratory Experimental Study on Interfacial Friction of Rock and Grout (암반과 그라우트체의 접촉면 마찰 평가를 위한 모의실내실험)

  • Park, Ji-Ho;Kim, Young-Uk;Jeong, Kyeong-Han;Kim, Jung-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3723-3728
    • /
    • 2011
  • This study investigated the friction behaviors of rock and grout through the small /large scale laboratory experiments. The small-scale laboratory tests were undertaken using a specially designed and fabricated equipments to simulate the contact surface of rock. In calibration chamber test, a artificial rock mass was prepared in soil container to measure the tensile resistance of grout. Test condition includes the grouting method of pressure involvement. The results of the tests show that the pressure grouting increases the frictional resistance significantly.

Observation of spatio-temporal soil loss in soil erosion experiment using a stereo photogrammetry technique (입체사진측량 기법을 활용한 토조 내 토사유출의 시공간적 변화 관찰)

  • Kim, Youngchan;Shin, Sanghoon;Byun, Jongmin;Paik, Kyungrock
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.306-306
    • /
    • 2015
  • 기존 토사유출실험 연구는 대체로 유출구에서 유사의 총량을 일정한 시간 간격으로 측정했다. 이 같은 방식으로는 총 토사유출량의 시간적 변화는 알 수 있으나, 토사유출의 공간적 분포 변화는 알 수 없기 때문에 토사유출의 취약지점을 파악하고 이를 제시할 수 없다. 본 연구에서는 이러한 한계를 극복하고자 입체사진측량 기법을 도입하여 토사유출의 공간분포를 측정하고 각 지점이 총 토사유출량에 기여하는 정도를 파악하였다. 토조($2m{\times}1m{\times}0.3m$)로부터 약 1.5 m 높이에서 고해상도 디지털 카메라를 이용하여 토조 내 표면을 촬영하였고, 입체사진측량 기법을 이용해 토조 내 수치표고모형(Digital Elevation Models)을 추출하였다. 수치표고모형 추출 과정에서는 고도값의 오차 범위를 확인하였고 격자 해상도를 다양하게 설정하면서 최적의 격자 해상도를 평가해보았다. 최종적으로 구한 일련의 수치표고모형으로부터 토사유출의 시공간적 변화를 파악할 수 있었으며, 이는 토조 내 토사유출 과정에 대한 보다 세밀한 이해를 가져올 것으로 기대된다.

  • PDF

Characterization of Increases in Volumetric Water Content in Soil Slopes to Predict the Risk of Shallow Failure (토사비탈면 표층붕괴 위험 예측을 위한 체적함수비 증가 특성 연구)

  • Suk, Jae-Wook;Kang, Hyo-Sub;Choi, Sun-Gyu;Jeong, Hyang-Seon;Song, Hyo-Sung
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.485-496
    • /
    • 2020
  • The characteristics of volumetric water content changes in soil slopes were studied here in an effort to identify the signs of heavy rain causing shallow slope failure. Volumetric water contents in cases with and without shallow failure were measured in flume and test-bed experiments. Measurement data from 282 experiments of both types revealed that the volumetric water content gradient in shallow failure events ranged from 0.072 to 0.309. In non-failure cases, the range was 0.01~0.32. Therefore, this one specific value cannot predict shallow slope failure. However, as the volumetric water content gradient increased, there was a clear tendency to shallow failure. By using this trend, criteria for four warning levels are suggested.

An Experimental Study on Settlement Reduction of Artificial Reef using Geosynthetics (토목섬유를 이용한 인공어초 침하 저감에 대한 실험 연구)

  • Ha, Yong-Soo;Kim, Yun-Tae
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.21-29
    • /
    • 2015
  • An artificial reef is a human-made underwater structure to improve marine environment and to provide a habitat for fish and other ocean wildlife. An artificial reef is placed on the ocean ground. In soft ground like most of the seabed soil, the ground has been settled due to weight of artificial reef. This study investigated the bearing capacity and settlement reduction effect of geosynthetics which were reinforced on the ground in a large size tank. Penetration tests and large soil tank laboratory tests were performed to investigate settlement reduction effect and bearing capacity on artificial reef with different spreading area of geogrid. Laboratory test results indicate that the spreaded geogrid under artificial reef reduce the settlement of ground and increase bearing capacity of ground.

A Study of Correlation between SPT N-value and Exerted Electrical Energy Required for Ground Drilling I : Basic Study (Laboratory Soil Box Test) (지반굴착에 소요되는 전기에너지와 표준관입시험 N값과의 상관관계 연구 I : 기초연구(실내토조실험))

  • Choi, Changho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.45-53
    • /
    • 2012
  • Ground drilling is a common method to conduct site investigation, soil improvement, and pile installation. In the point of construction ground drilling requires electrical energy to drill a hole in ground in which the energy exerts into the motor located on the head of auger and generates rotational power. In this paper it is verified that the exerted electrical energy is closely related to the strength characteristics of ground. Measurement sensors, recording system, and drilling system were developed to obtain exerted motor current and drilling depth and laboratory soil box tests were carried out. The measured motor current and boring depth were applied to predict SPT N-value and the prediction results were compared to SPT N-value of laboratory tests. The test results show that the exerted electrical energy to bore ground be a good index to estimate SPT N-value.

Soil Deformation Tracking in Model Chamber by Targetless Close-Range Photogrammetry (무타겟 사진측량 기반 모형 토조 내 지반 변위 측정)

  • Lee, Chang No;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.555-562
    • /
    • 2019
  • This paper presents soil deformation measurement in model chamber based on photogrammetry. We created an aluminum framed acrylic model chamber with soil inside and applied photogrammetry to measure soil deformation caused by loading tests. The soil consists of 40% black and 60% regular sand to create image contrast in soil images. In preprocessing, the self camera calibration was carried out for IOPs (Interior Orientation Parameters), followed by the space resection to estimate EOPs (Exterior Orientation Parameters) using control points located along the aluminum frame. Image matching was applied to measure the soil displacement. We tested different matching window sizes and the effect of image smoothing. Experimental results showed that 65x65 pixels of window size produced better soil deformation map and the image smoothing was useful to suppress the matching outliers. In conclusion, photogrammetry was able to efficiently generated soil deformation map.

Laboratory Test of CLSM with Botton Ash (Bottom ash를 이용한 유동성 뒤채움재의 실내모형실험)

  • Lee, Kwan-Ho;Lee, Kyung-Joong;KIm, Yun-Tae;Cho, Jae-Yun
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.197-197
    • /
    • 2011
  • 최근 들어 전력 사용량의 증가로 인한 화력발전소의 부산물인 석탄회 중 바텀애시와 각종 공공사업과 관련하여 해마다 현장발생토의 발생량이 지속적으로 증가하고 있는 추세이다. 바텀애시와 현장발생토사를 효과적으로 재활용하는 방법 중 유동성 뒤채움재를 개발하여 활용하는 방안을 모색하기 위한 연구이다. SP로 분류된 흙 현장발생토와 서천 화력발전소에서 발생하는 석탄회 중 입경이 0.9~1.5mm의 바텀애시만을 선별하여 현장발생토와 바텀애시의 비율을 7 : 3으로 변환한 최적배합을 선정하여 강재로 제작된 가로 80cm, 세로 60cm, 높이 90cm의 모형토조를 이용하여 실험을 진행하였으며, 사용상 지하 매설이 되는 관의 거동 특성은 확인하기 위하여 내경 30cm, 두께 8mm의 연선관 중 하나인 PVC관을 원형지하매설관으로 선정하여 배합을 타설하는 과정과 타설 후 7일간의 양생기간을 거친 후 차량하중으로 가정할 수 있는 하중을 가하여 원형지하매설관의 관외부에서 수직방향과 수평방향의 토압과 관내부의 수직 수평방향 변위 그리고 관 자체의 횡 종단 변형을 측정하여 원형지하매설관의 거동특성을 파악하였다. 타설시 지하매설관은 유동성 뒤채움재의 특성으로 인하여 시간이 지남에 따라 안정화되는 것을 확인할 수 있었으며, 최대하중을 3300kgf로 하여 하중 재하 후 지하매설관의 거동특성은 대체적으로 일반 모래를 사용하여 실험한 값보다 적은 변형 특성을 보이고 있으나 수평토압의 경우 일반적인 흙의 변형과 전혀 상이한 결과값을 보이는 경우도 있어 추가적인 실험 및 고찰의 필요하다. 본 실험에서 사용한 최적배합비 이외의 배합으로 같은 실험을 수행하여 바텀애시 량의 가감 및 재활용 재료인 폐타이어 고무칩등을 첨가한 실험을 계획하고 있으며 추후 실내시험과 모형실험을 토대로 유한요소해석을 추가로 시행하여 실험값과 해석값의 비교를 할 예정이다.

  • PDF

A Study on The Scale Effect of Landslide Model Tests (산사태 모형실험에서의 Scale Effect에 관한 연구)

  • Jeong, Jisu;Ji, Younghwan;Kim, Yootae;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.8
    • /
    • pp.5-12
    • /
    • 2011
  • This study was performed to analyze the degree of rainfalls, the duration time of rainfalls, the inclination of slopes and other damage causes depending on the ground condition, when the landslide occurs by the rainfall. Based on that, a big and a small model soil box were compared to examine the features of landslides, which is ultimately for forecasting landslides. An artificial rainfall device was installed in the model box, and the large model box has a real-size slope in it. Also, various measures were fulfilled such as collapse forms, a pore pressure, an earth pressure and moisture contents in order to analyze the effect of the model box size on the landslide mechanism and to test the usability of a small model box as a material for landslide experiments.

Experimental Study on Development for Separation and Reinforcement Geotextiles with Horizontal Wicking Drain Property (수평방향의 위킹 배수 특성을 지닌 분리·보강용 지오텍스타일 개발을 위한 실험적 연구)

  • Kim, Hong-Kwan;Ahn, Min-Soo
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.215-224
    • /
    • 2019
  • According to the recent civil engineering construction work site which is a complex process, development of multi-functional geotextiles is required. In this study, the characteristics of five different modified cross-section fiber yarns for the selection of wicking yarns were analyzed and yarns that can achieve target properties were selected. Experimental prototype geotextiles suitable for horizontal wicking drain property and reinforcement was developed and its tensile strength, 2% secant modulus, vertical water permeability, AOS, friction characteristics by the direct shear method, and vertical/horizontal wicking test were analyzed. These tests are conducted to verify the performance of the geotextiles with horizontal wick drain property, separation and reinforcement developed in this study. As a results of the indoor soil box test, it was confirmed that the geotextiles using the wicking yarn sufficiently exhibited the function of discharging excess pore water in the horizontal direction.