• Title/Summary/Keyword: 실내모형토조

Search Result 66, Processing Time 0.02 seconds

A Study on the Calculation of Lateral Flow Pressure of Polluted Soils with Various Water Contents (함수량이 다른 오염지반의 측방유동압 산정에 관한 연구)

  • 안종필;박경호
    • The Journal of Engineering Geology
    • /
    • v.12 no.1
    • /
    • pp.75-88
    • /
    • 2002
  • When unsymmetrical surcharge is worked on polluted soft soils, large plastic shearing deformation such as settlements, lateral displacement, upheavals and shearing failure occured in the soils and they have often done considerable damages to the soils and structures. Accordingly, this study conducts laboratory pilots test to investigate the determination method of lateral flow pressure of polluted soft soils by comparing it to existing equations. The model test is performed that a model stock device is made and polluted soils are filled in a container which fires the soils. Then the displacement is observed as surcharge load is increased by regular intervals at untrained condition. The result shows that test the lateral flow pressure is adequately calculated by the equation (P=K$_{0}$YH) and the maximum value of lateral flow pressure Is found near 0.3H of layer thickness(H) and is higher to ground surface than synthesis pattern, Poulos distribution pattern and soft clay soils(CL, CH) which is not polluted.

Behavior of Model Sheet Piles under Vertical Loads (수직하중을 받는 모형 강널말뚝의 거동)

  • 윤여원;김두균
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.5-16
    • /
    • 1998
  • In order to study the behavior of the sheet pile under vertical load in sands, model pile tests using calibration chamber are performed. For this research, five model piles, with the same section area and different degree of inclination of flange, were made. And model pile tests were conducted for each of these piles with different relative density and direction of applied load. For model pile which has the same shape, compression capacity is about 100% higher than pullout capacity and the difference increases with increasing relative density. Pullout ultimate capacity and corresponding displacement increase with increasing relative density and the pullout capacities remained almost the same irrespective of the inclination of flanges for the same density. The ultimate capacity under compression load is highest at 30$^{\circ}$ of inclination of flanges and the trend is more evident with increasing relative density. From the analysis of load distribution, the higher loading capacity at 30$^{\circ}$ of inclination of flanges with same section area may be attributed to the partial soil plug between flanges.

  • PDF

Characteristics of Bearing Capacity of Soft Ground Reinforced by Vertical Mat (연직 매트로 보강된 연약지반의 지지력 특성)

  • Shin, Eun-Chul;Lee, Gil-Ho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.6
    • /
    • pp.83-90
    • /
    • 2012
  • Generally, the effect of the cement deep mixing method on the improvement of clay ground is far greater than the effect of physical improvement. Although it leads to great improvement strength in the initial stage, there are not many constructional precedents in Korea and it is hard to manage quality according to the cement-clay mixing method. In order to figure out the strength characteristics according to the mixing ratio of cement, sand, and clay and the improvement characteristics of weak ground according to the forms of the specimens to be improved, marine clay was used in this study to conduct the uniaxial compression test and soil bin model test. The test piece specimens for the uniaxial compression test were mixed with sand in a fixed ratio with the criterion of the water cement ratio. The cement was mixed with clay in the ratios of 10%, 20%, 30%, and 40% to the clay weight. The moisture content of the soil ground was made in the ratios of 40%, 60%, and 80%. The test piece specimens went through curing by moistening for 7, 14, and 28 days and underwent the uniaxial compression test according to the curing period. For the bearing test, the soil bin models were made and the ground improved in the Mat type was formed. After that, the bearing strength was compared in this study according to the improvement ratio and analyzed the intervening effect between the walls of the improved specimens.

A Study on the Ground Reinforcement of Jeju Scoria Layer by Chemical Grouting (약액주입에 의한 제주도 송이지층의 지반보강에 관한 연구)

  • Yang, Kiho;Park, Jeongjun;Kim, Younghun;Byun, Yoseph;Lee, Eunjong;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.75-82
    • /
    • 2014
  • Recently, public works becoming bigger in Jeju are implemented various kinds of ground reinforcement method including the chemical grouting method. In this study, we have been investigated on the proper material and the injection condition for the excellent injection effect and the excellent strength of injection material and the permanent waterproof and reinforcement through the experiment. The kind of injection material has been selected through the uniaxial compression test and the endurance test of injection material as the chamber test. An experiment was performed with model ground made of scoria, the injection performance of selected material has been identified through the evaluation test of injection range using the decision test of injection amount and the calibration chamber test. As a result of test, it has been analyzed that MSG appeared to have the excellent strength, durability and injection performance all compared with the ordinary cement, this result is judged to be possible as the ancillary data of design at time of design and construction with the chemical grouting method in the future.

Evaluation of Suction Installation for the Circular Pipe into Low-water Sandy Ground via Model Test (모형실험을 활용한 저수심 사질토 지반에서 원형강관 설치 석션압 평가)

  • Xin, Zhen-Hua;Kim, Jae-Hyun;Lee, Ju-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.1-10
    • /
    • 2021
  • In this study, a circular pipe can be installed by suction pressure for construction on soft ground with a low-water level. A series of laboratory-scale model tests were conducted in sandy ground to comprehend the suction pressure of the circular pipe in low-water levels. For repeated tests on saturated sandy soil, a container was mounted with three vibration generators on the floor. A repetitive vibration was applied using the vibration system for ground compaction. In the model tests, different diameters and thicknesses on saturated sandy soil with a water depth were considered. The result showed that the suction pressure increased with increasing penetration depth of the circular pipe. Moreover, the suction pressure required to penetrate the pipe decreased with increasing diameter. In the low-water level, the total suction pressure measured at the top lid increased because additional suction pressure is required to lift the water column. On the other hand, this led to a decrease in suction pressure to penetrate the circular pipe because the weight of the water column is applied as a dead load. Therefore, it is necessary to consider the water level to design the required suction pressure accurately.

Evaluation of Applicability of HMS-25 as the Railroad Roadbed Material (철도 노반재로서의 수경성 입도 조정 고로슬래그(HMS-25)의 적용성 평가)

  • 황선근;이성혁;이시한;최찬용
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.157-165
    • /
    • 2000
  • The applicability and performance of HMS-25 as the railroad roadbed materials were evaluated through the model and laboratory tests. The uniaxial compression test of HMS-25, model soil box test, and combined resonant column and torsional shear test were performed for static and dynamic analysis of railroad roadbed. The uniaxial compression test result of HMS-25 shows steady increase in strength due to hardening chemical reaction between HMS-25 and water. The result of model soil box test reveals that railroad roadbed of HMS-25 is better than that of soil in several aspects such as bearing capacity and settlement. The combined resonant column and torsional that shear test result indicates that shear modulus of HMS-25 increases with the power of 0.5 to the confining pressure and that shear modulus increases with the increase of curing period.

  • PDF

Sand-Box Evaluation for Vibration-Attenuation of Concrete Panels with Recycled Materials (재활용재 혼입콘크리트 패널의 진동감쇠성에 대한 사조실험)

  • 정영수;최우성;조성호
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.171-182
    • /
    • 1998
  • Vibration-controlled concrete has been developed by using various concrete mixtures, such as latex, rubber powders, plastic resins and polystyrene(styrofoam). As part of the recycling research of obsolete aged tires and plastic materials, various vibration-reducing mixtures are used for 10 concrete panels having above 200 kg/cm$^2$ in uniaxial compressive strength. Plywood box with sand uniformly saturated by the raining device has been used for the analysis of the impact wave, of which data have been transfered by the FFT technique to comparatively investigate damping ratios of 10 concrete panels.According to wave propagation analysis on vibration-controlled concrete for this research, it can be concluded that Latex concrete has relatively larger damping ratios than those for noncontrolled normal concrete in a similar compressive strength

An Experimental Study on the Bearing Characteristics of Auger-Cast Pile Installed Using Expansive Mortar

  • Yoon, Sung-Soo;Lee, Won-Je;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.3
    • /
    • pp.99-111
    • /
    • 1999
  • The frictional capacity of auger-cast piles is often very small because of the disturbance of the soil surrounding the pile during the excavation process. Usage of expansive agents and a pressurized injection technique for auger-cast piles should improve the frictional resistance between pile and soil. This paper presents the test results of auger-cast model piles installed with expansive mortar in laboratory compacted weathered soil. The model piles were installed in a calibration chamber with a variation in the amount of expansive agent, the injection process and the chamber pressure. It was observed that the pile shaft resistance increases with the increased amount of expansive agent, and also increases when mortar is pressure injected. The shaft resistance increased up to 24% for the pile installed only with expansive mortar and increased up to 56% for the pile installed with the pressurized injection of expansive mortar, compared with that of piles with plain mortar.

  • PDF

The Model Test on Load Reduction Effect of Caps Foundation Method (캡스기초공법의 하중경감효과에 관한 모형시험)

  • Park, Jong-Man;Kang, Chi-Gwang;Kwak, Jung-Min;Han, Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.479-486
    • /
    • 2019
  • The caps foundation method can reduce the load of a building by using the arching effect, but verification of the method is still insufficient. In this paper, a model test was performed to quantitatively prove the load reduction effect by this method. The test was carried out using six conditions according to the size of caps foundation block and the area of the loading plate. The test results show that the earth pressure was the highest at the position closest to the loading point regardless of the size of caps foundation block and the area of the loading plate. At the highest earth pressure position, when the loading plate area was 30 cm × 30 cm, the earth pressure of a small block was reduced by 35.4% on average, and that of a big block was reduced by 39.7% compared to the pressure with no block. When the loading plate area was 60 cm × 60 cm, the earth pressure of the small block was reduced by 33.9% on average, and the earth pressure of the big block was reduced by 42.7%. Therefore, if the caps foundation method is applied, the load will be reduced by more than 33% for a small block and 39% for a big block.

Freezing and Bearing Capacity Characteristics of Road Foundations under Temperature Condition (온도조건에 의한 도로하부 지반의 동결 및 지지력 특성)

  • Shin, Eun-Chul;Kim, Sung-Hwan;Park, Jeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.3
    • /
    • pp.5-14
    • /
    • 2012
  • In the current design codes for anti-freezing layer, the thickness of anti-freezing layer is calculated by freezing depth against the temperature condition. Therefore, they have a tendency of over-design and uniform thickness without the considerations of thermal stability, bearing capacity and frost susceptibility of materials. So, it is essential for studying the appropriateness and bearing capacity of road foundation materials as well as their seasonal and mechanical properties to take an appropriate and reasonable design of the road structure system. In this paper, the freezing and bearing capacity characteristics of typical road foundation materials were evaluated in the large scale laboratory test. LFWD (light falling weight deflectometer) was used to determine the change of elastic modulus ($E_{LFWD}$) caused by to the frost heave and thaw. Furthermore, the influence of crushed natural aggregate on the freezing of the subgrade soil was studied to verify the function and effectiveness of the anti-freezing layer.