• Title/Summary/Keyword: 실내대기오염물질

Search Result 88, Processing Time 0.029 seconds

Reviews on the Studies of MTBE Contaminants in Groundwater

  • 이지훈;이진용;천정용;이강근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.55-58
    • /
    • 2000
  • Methyl tertiary butyl ether (MTBE) is a gasoline additive that boosts the oxygen content in fuel (an oxygenate), resulting in less air-polluting carbon monoxide being released from vehicle exhaust systems. Then, groundwater contamination problems have been developed in areas where the chemical is used. Common sources of water contamination by MTBE include leaking underground gasoline storage tanks and leaks and spills from above ground fuel storage tanks, etc.. Studies on the chemical and these problems are going on abroad vigorously. These studies should be performed in our country as well more actively. This paper reviews on articles on these studies and focuses on the identification of the chemical as a groundwater contamination source.

  • PDF

Implement of Analysis system with Indoor Environment Monitoring Based on IoT (사물인터넷 기반 실내 환경 모니터링 분석 시스템 구현)

  • Nam, Jae-hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1687-1692
    • /
    • 2019
  • In the era of the fourth industrial revolution, advanced technologies such as the Internet of Things(IoT) and big data are emerging. However, the level of application of IoT to indoor environment is very weak. Therefore, it is necessary to develop a system for analyzing air pollutants or indoor air quality through real-time monitoring using the IoT. This paper implements a system that measures indoor environmental values using Arduino and various sensors, and stores the information obtained from various sensors into a database of server. The information stored in the server was built as a database and utilized in the ventilation system or air cleaner installed in the home or company's room. In the proposed system, it is possible to check the immediate indoor environmental condition through the LED status display of the monitoring sensor module while reducing the cost of the sensor used to implement IoT technology.

A Study on the Performance Evaluation and by-product of styrene decomposition by Non-thermal Plasma Processing (플라즈마 공정에 의한 Styrene 처리에 관한 성능 평가 및 부산물 동정 연구)

  • 박정욱;전보경;최금찬
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.69-70
    • /
    • 2003
  • 최근 실내공기 질(IAQ : Indoor Air Quality)에 관한 인식이 높아지고 있으며 환경개선에 상응하는 기술 개발의 중요성이 크게 부각되고 있다. 실제 산업체에서는 여러 가스정화기술들이 오염물질제거에 이용되어 왔고, 그 한 분야인 N.T.P(Non-thermal plasma Process) 공정도 다양한 각도에서 연구가 수행되어 왔다. 그러나, 이 기술의 실용화를 위한 설계변수 개념의 연구는 부족한 실정으로, 이에 본 연구는N.T.P 공정에 의한 가스정화의 반 경험식 도출과 이를 이용한 성능 평가 고찰이 주목적이다. 또한, 반응기 통과 후 나오는 부산물을 동정하여, 차후 후단에 사용할 촉매를 결정 하고자 한다. (중략)

  • PDF

Photocatalytic Degradation of Methyl-tertiary butyl ether using Element-Enhanced Photocatalyst

  • Yang, Chang-Hui;Sin, Myeong-Hui;Jang, Jong-Dae;Lee, Jin-U;Choe, Seong-Rak;Jo, Wan-Geun
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.110-113
    • /
    • 2008
  • 최근 가시광선에서 응답하는 광촉매를 이용하여 저농도의 일반적인 실내 대기 오염물질 제어를 위한 적용가능성에 대해 많은 평가가 있어왔다. 가시광선에서 활성을 보이는 질소 원소가 도핑된 TiO$_2$광촉매를 이용하여 대표적인 휘발성유기화합물질들 중에 하나인 MTBE의 분해율에 대한 실험을 실시하였다. 본 연구에서 여러 가지 변수들 중에 농도와 상대습도에 따라 MTBE의 분해율에 대하여 실험하였으며, 본 연구의 실험조건하에서 질소가 도핑된 TiO$_2$ 광촉매를 통해서 효과적으로 MTBE가 제거됨을 확인 할 수 있었다.

  • PDF

Application of Sulfur-doping Titanium Dioxide to Trichloroethylene Oxidation

  • Yang, Chang-Hui;Sin, Myeong-Hui;Jang, Jong-Dae;Lee, Jin-U;Lee, Jun-Ho;Jo, Wan-Geun
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.127-130
    • /
    • 2008
  • 가시광선에서 활성을 보이는 TiO$_2$광촉매를 이용하여 대표적인 휘발성유기화합물질들 중에 하나인 TCE의 분해을에 대한 실험을 수행하였다. 본 연구에서 여러 가지 변수들 중에 농도와 상대습도에 따른 휘발성유기화합물의 분해율에 대하여 실험하였으며, 농도 및 상대습도의 변화에 따른 분해율의 영향에 대하여 확인 할 수 있었다. 향후 광촉매를 실제 실내대기에 적용하기 위해 더욱 다양한 조건에서 여러 가지 오염물질에 대한 연구들이 진행되어야 할 것이다.

  • PDF

Resistance Functions of Woody Landscape Plants to Air Pollutants (I) - SOD Activity - (조경수목(造景樹木)의 대기오염물질(大氣汚染物質)에 대한 방어기능(防禦機能) (I) - SOD 활성(活性)을 중심으로 -)

  • Kim, Myung Hee;Lee, Soo Wook
    • Journal of Korean Society of Forest Science
    • /
    • v.81 no.2
    • /
    • pp.164-176
    • /
    • 1992
  • This study was conducted to determine the toxic effects of air pollutants on landscaping trees, Pinus densiflora, Pinus koraierasis, Ginkgo biloba, Liriodeytdron tulipifera, Platanus occidentalis and their resistance to the pollutant toxicity in urban and industrial regions of Seoul and Taejon, Korea. Total sulfur content and superoxide dismutase activity were analysed in tree foliage of Pinus densiflora, Pinzes koraiensis, Ginkgo biloba, Liriodendron tulipifera, Platanus occidentalis. In addition, SOD activity was analyzed in the foliage of tree seedlings, i.e. Pinus densijlora, Pinus koraiensis, Ginkgo biloba, Liriodendron tulipifera, with the lurnigation of $SO_2$ in gas chamber 4 hours a day for six days. In all species total sulfur content and SOD activity had a positive correlation. Air pollutants accumulated in tree tissues were supposed to enhance the enzyme activity like SOD providing with the resistance mechanisms. Trees under the air pollution stress increased enzyme activity to develop internal self-resistance against pollutants, but after a critical point enzyme-activity decreased gradually and resulting in injury after all, Deciduous trees had greater filtration capacity than conifers and coniferous trees showed greater resistance against air pollutants than deciduous species. Foliage SOD activity was higher in polluted area than in unpolluted area for most species. Coniferous species and mature trees had higher SOD activity than deciduous seedlings. Especially Pinus koraiensis, Ginkgo biloba and Plcatanus occidentalis had higher SOD activity than other species. The tree species with the high SOD activity showed strong resistance against air pollutants. In 2nd-year needles of Pinus densiflora seedlings and current and 2nd-year needles of Pinus koraiensis seedlings containing high native SOD activity, SOD activity increased with the increase of $SO_2$ level. But in seedlings containing low native SOD activity, SOD activity increased at 0.5ppm $SO_2$ level while it decreased at 1.5 and 2.5ppm $SO_2$. Changes of SOD activity was different between species and in most species SOD seemed to participate in resistance mechanism.

  • PDF

Indoor Air Data Meter and Monitoring System (실내 공기 데이터 측정기 및 모니터링 시스템)

  • Jeon, Sungwoo;Lim, Hyunkeun;Park, Soonmo;Jung, Hoekyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.1
    • /
    • pp.140-145
    • /
    • 2022
  • In an advanced modern society, among air pollutants caused by urban industrialization and public transportation, fine dust flows into indoors from the outdoors. The fine dust meter used indoors provides limited information and measures the pollution level differently, so there is a problem that users cannot monitor and monitor the data they want. To solve this problem, in this paper, indoor air quality data fine dust and ultra-fine dust (PM1.0, PM2.5, PM10), VOC (Volatile Organic Compounds) and PIR (Passive Infrared Sensor) are used to measure fine dust. and a monitoring system were designed and implemented. We propose a fine dust meter and monitoring system that is installed in a designated area to measure fine dust in real time, collects, stores, and visualizes data through App Engine of Google Cloud Platform and provides it to users.

The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model (실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.E
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

A Study on Characteristics of Main Indoor Air Pollutants and Ventilation in Nursery Facilities (어린이집 실내공기 중 주요 오염물질의 특성 및 환기에 관한 연구)

  • Kim, Sang Cheol;Kang, Byeong-Chang;Lee, Sang-Uk;Kim, Gi-Doo;Seo, Won-Ho;Kim, Jong-Heon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.245-250
    • /
    • 2014
  • As the number of nursery facilities and infants who stay there is continuously increasing, IAQ (Indoor Air Quality) of nursery facilities should be managed strictly and thoroughly because infants are more susceptible to infections due to their low resistivity. In this study the characteristics of IAQ and ventilation associated factors were investigaed for suggesting a desirable condition for IAQ management. Environmental factors were not much related to IAQ characteristics rather than internal factors such as structures of the room. And the positive effect of ventilation on IAQ was obvious and seemed to hinge on factors related to window area especially window/wall ratio. Results of this study indicate that the structure with broader window area of a room and frequnet ventilation can be an effective way for keeping IAQ of nursery facilities clean and safe.

Analysis of Indoor Air Pollutants from Elementary School Classrooms with Different Environment in Ulsan, Korea (울산광역시 초등학교 실내공기오염물질의 환경적 특성에 따른 농도 분석)

  • Lee, Chi-Hyeon;Lee, Byeong-Kyu;Kim, Yang-Ho;Lee, Ji-Ho;Oh, In-Bo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.97-116
    • /
    • 2011
  • This study analyzed indoor air pollutants from elementary school with different environment. Air sampling and measurement were carried out from classrooms and hallways from three target elementary schools in the fall and winter seasons. The winter average concentrations of $PM_{10}$, $CO_2$, CO, aldehydes and ketones, and benzene were higher than the fall ones. The fall average concentrations of $O_3$ and $NO_2$ were higher than the winter ones. The concentrations of $PM_{10}$ and $CO_2$ at the schools near the heavy traffic areas and having poor ventilation were higher than those from the other elementary school. The average concentration of CO at the school having heavy traffic volume was highest. The concentrations of $O_3$, $NO_2$, aldehydes and ketones, and VOCs at the school near the shipbuilding industries were highest among the three elementary schools.