• Title/Summary/Keyword: 신호 획득

Search Result 1,350, Processing Time 0.023 seconds

Shear-wave elasticity imaging with axial sub-Nyquist sampling (축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법)

  • Woojin Oh;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.403-411
    • /
    • 2023
  • Functional ultrasound imaging, such as elasticity imaging and micro-blood flow Doppler imaging, enhances diagnostic capability by providing useful mechanical and functional information about tissues. However, the implementation of functional ultrasound imaging poses limitations such as the storage of vast amounts of data in Radio Frequency (RF) data acquisition and processing. In this paper, we propose a sub-Nyquist approach that reduces the amount of acquired axial samples for efficient shear-wave elasticity imaging. The proposed method acquires data at a sampling rate one-third lower than the conventional Nyquist sampling rate and tracks shear-wave signals through RF signals reconstructed using band-pass filtering-based interpolation. In this approach, the RF signal is assumed to have a fractional bandwidth of 67 %. To validate the approach, we reconstruct the shear-wave velocity images using shear-wave tracking data obtained by conventional and proposed approaches, and compare the group velocity, contrast-to-noise ratio, and structural similarity index measurement. We qualitatively and quantitatively demonstrate the potential of sub-Nyquist sampling-based shear-wave elasticity imaging, indicating that our approach could be practically useful in three-dimensional shear-wave elasticity imaging, where a massive amount of ultrasound data is required.

A Study of a Module of Wrist Direction Recognition using EMG Signals (근전도를 이용한 손목방향인식 모듈에 관한 연구)

  • Lee, C.H.;Kang, S.I.;Bae, S.H.;Kwon, J.W.;LEE, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.1
    • /
    • pp.51-58
    • /
    • 2013
  • As it is changing into aging society, rehabilitation, welfare and sports industry markets are being expanded fast. Especially, the field of vital signals interface to control welfare instruments like wheelchair, rehabilitation ones like an artificial arm and leg and general electronic ones is a new technology field in the future. Also, this technology can help not only the handicapped, the old and the weak and the rehabilitation patients but also the general public in various application field. The commercial bio-signal measurement instruments and interface systems are complicated, expensive and large-scaled. So, there are a lot of limitations for using in real life with ease. this thesis proposes a wireless transmission interface system that uses EMG(electromyogram) signals and a control module to manipulate hardware systems with portable size. We have designed a hardware module that receives the EMG signals occurring at the time of wrist movement and eliminated noises with filter and amplified the signals effectively. DSP(Digital Signal Processor) chip of TMS320F2808 which was supplied from TI company was used for converting into digital signals from measured EMG signals and digital filtering. We also have used PCA(Principal Component Analysis) technique and classified into four motions which have right, left, up and down direction. This data was transmitted by wireless module in order to display at PC monitor. As a result, the developed system obtains recognition success ratio above 85% for four different motions. If the recognition ratio will be increased with more experiments. this implemented system using EMG wrist direction signals could be used to control various hardware systems.

  • PDF

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.

Efficient Acquisition of High-Quality ISAR Images Using the Discrete Gabor Representation in an Oversampling Scheme (Oversampling 형태를 갖는 Discrete Gabor Representation을 이용한 고품질 표적 ISAR 영상의 효율적인 획득)

  • Park, Ji-Hoon;Yang, Woo-Yong;Bae, Jun-Woo;Kang, Seong-Cheol;Myung, Noh-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.566-573
    • /
    • 2013
  • Inverse synthetic aperture radar(ISAR) images have been widely used in non-cooperative target recognition(NCTR). One of the most important issues in ISAR imaging is the improvement of the image smeared by target motion. In this paper, we propose the discrete Gabor representation(DGR) in an oversampling scheme for efficient acquisition of high-quality ISAR images. The DGR compartmentally assigns the Gabor coefficients to unit cells of the time-frequency grid related to the given Gabor logons. Thus, it can show an excellent time-frequency concentration and effectively discriminates the Doppler components from point-scatterers. The simulation results demonstrated that the DGR not only obtained high-quality ISAR images but also retained computational efficiency.

Low Power Parallel Acquisition Scheme for UWB Systems (저전력 병렬탐색기법을 이용한 UWB시스템의 동기 획득)

  • Kim, Sang-In;Cho, Kyoung-Rok
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.1
    • /
    • pp.147-154
    • /
    • 2007
  • In this paper, we propose a new parallel search algorithm to acquire synchronization for UWB(Ultra Wideband) systems that reduces computation of the correlation. The conventional synchronization acquisition algorithms check all the possible signal phases simultaneously using multiple correlators. However it reduces the acquisition time, it makes high power consumption owing to increasing of correlation. The proposed algorithm divides the preamble signal to input the correlator into an m-bit bunch. We check the result of the correlation at first stage of an m-bit bunch data and predict whether it has some synchronization acquisition information or not. Thus, it eliminates the unnecessary operation and save the number of correlation. We evaluate the proposed algorithm under the AWGN and the multi-Path channel model with MATLAB. The proposed parallel search scheme reduces number of the correlation 65% on the AWGN and 20% on the multi-path fading channel.

An Efficient Receiver Structure Based on PN Performance in Underwater Acoustic Communications (수중음향통신에서 PN 성능 기반의 효율적인 수신 구조)

  • Baek, Chang-Uk;Jung, Ji-Won
    • Journal of Navigation and Port Research
    • /
    • v.41 no.4
    • /
    • pp.173-180
    • /
    • 2017
  • Underwater communications are degraded as a result of inter symbol interference in multipath channels. Therefore, a channel coding scheme is essential for underwater communications. Packets consist of a PN sequence and a data field, and the uncoded PN sequence is used to estimate the frequency and phase offset using a Doppler and phase estimation algorithm. The estimated frequency and phase offset are fed to a coded data field to compensate for the Doppler and phase offset. The PN sequence is generally utilized to acquire the synchronization information, and the bit error rate of an uncoded PN sequence predicts the performance of the coded data field. To ensure few errors, we resort to powerful BCJR decoding algorithms of convolutional codes with rates of 1/2, 2/3, and 3/4. We use this powerful channel coding algorithm to present an efficient receiver structure based on the relation between the bit error of the uncoded PN sequence and coded data field in computer simulations and lake experiments.

Beamforming based RFID System for Moving Target Tagging (이동 물체의 태깅을 위한 디지털 빔포밍 기반 RFID 시스템)

  • Jeon, Seong-Ha;Jeon, Hyeon-Moo;Shin, Seong-Gwan;Sohn, Chae-Bong;Yang, Hoon-Gee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1713-1720
    • /
    • 2014
  • RFID technology has evolved from basic operation like the acquisition of tag IDs into a more complicated operation such as the simultaneous acquisition of tag IDs and their positions and recently, is raising the possibility of obtaining additional informations, which include their velocities, directions and distances. In this paper, we present a RFID system that can fullfil aforementioned advanced functions. In the proposed system, a tag transmits a sequence of FMCW pulses modulated by ID signals and a reader separates the tag signals in azimuth direction using an array antenna, followed by the FMCW demodulation from which distances, velocities as well as the tag IDs are extracted. We propose a receiver structure of the reader and theoretically analyze its operability. Moreover, its performance is examined by simulation.

PET Detector Design with a Small Number of Photo Sensors (적은 수의 광센서를 사용한 PET 검출기 설계)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.525-531
    • /
    • 2021
  • The detector of the positron emission tomography (PET) is composed using a plurality of scintillation pixels and photo sensors. The use of multiple photo sensors increases cost and complicates signal processing. In this study, a detector with reduced cost and simple signal processing was designed using a small number of photo sensors. A scintillation pixel and a small number of photo sensors were used, and a optical guide was used to deliver light to all the photo sensors. A reflector is applied to the scintillation pixel and the optical guide to transmit the maximum amount of light to the photo sensor. A diffuse reflector and a specular reflector were used for the reflector, and a flood image was obtained by applying different thicknesses of the optical guide. An optimal combination was selected through comparative analysis of the acquired flood images. As a result, when specular reflectors were used for both the scintillation pixel and the optical guide, excellent flood images were obtained from optical guides of all thicknesses. For the optical guide, the optimal image was obtained when using a 3 mm thickness in consideration of the size of the image and the analysis of the point where the image of the scintillation pixel was formed.

Studio Digital Camera Characterization by Using Multiple Regression analysis Method (다중회귀분석법을 이용한 스튜디오형 디지털 카메라 칼라 보정)

  • 윤창락;조맹섭
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.395-397
    • /
    • 1999
  • 디지털 카메라에 의해 획득된 RGB 칼라 신호는 디지털 카메라의 하드웨어적인 특성에 따라 서로 다른 값을 가지는 장비 의존적(Device Dependent) 특성을 가지며, 칼라 운영 시스템(CMS; Color Management System)이 프로파일 연결 칼라 공간(PCS:Profile Connection Space)으로 사용하는 CIE XYZ 칼라 공간에 대해 비선형적인 특성을 가진다. 본 논문에서는 디지털 카메라의 RGB 칼라 신호를 장비 독립적(Device Independent)인 CIE XYZ 칼라 공간으로 변환하는 변환 행렬을 구하는 방법을 제안한다. 변환 행렬은 비선형 다항식을 이용하여 3$\times$m의 변환 행렬을 구하고, 실험에 사용되는 칼라 샘플의 수에 따른 일반화(Generalization) 성능을 평가한다.

  • PDF

Develoment of Echo Sounder for fast Signal Processor (고속신호처리 프로세서를 이용한 음향측심기 개발)

  • Park, Dong-Jin;Yoon, Yang-Ho;Kim, Young-Il;Oh, Young-Seock;Park, Seung-Soo
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.207-208
    • /
    • 2006
  • 기존의 음향측심기는 복잡한 하드웨어 구조로 인해 크기와 중량이 큰 단점이 있었다. 이에 본 개발에서는 이러한 단점을 보완하기 위해 고속의 단일칩을 적용하여 단순구조의 하드웨어로 구성하였으며, 그 결과 장비의 크기 및 중량을 감소시킬 수 있었고 또 신호처리 기법을 적용하여 측정 데이터의 안정성을 획득 하였다.

  • PDF