• Title/Summary/Keyword: 신호 획득

Search Result 1,356, Processing Time 0.025 seconds

Remote Access and Data Acquisition System for High Voltage Electron Microscopy (초고전압 투과전자현미경의 원격제어 및 데이터 획득 시스템)

  • Ahn, Young-Heon;Kang, Ji-Seoun;Jung, Hyun-Joon;Kim, Hyeong-Seog;Jung, Hyung-Soo;Han, Hyuck;Jeong, Jong-Man;Gu, Jung-Eok;Lee, Sang-Dong;Lee, Jy-Soo;Cho, Kum-Won;Kim, Youn-Joong;Yeom, Heon-Young
    • Applied Microscopy
    • /
    • v.36 no.1
    • /
    • pp.7-16
    • /
    • 2006
  • A new remote access system for a 1.3 MV high voltage electron microscope has been developed. Almost all essential functions for HVEM operation, huck as stage control, specimen tilting, TV camera selection and image recording, are successfully embedded into this prototype of the remote system. Particularly, this system permits perfect and precise operation of the goniometer and also controls the high resolution digital camera via simple Web browsers. Transmission of control signals and communication with the microscope is accomplished via the global ring network for advanced applications development (GLORIAD). This fact makes it possible to realize virtual laboratory to carry out practical national and international HVEM collaboration by using the present system

A Study on Usefulness of Diffusion Tensor Imaging (DTI6D) in Brain Ischemic Disease (뇌 허혈성 질환 확산텐서영상(DTI6D)의 임상적 유용성에 관한 연구)

  • Goo, Eunhoe
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.223-228
    • /
    • 2013
  • We evaluated the usefulness of $DTI_{6D}$ which was acquiring six direction diffusion data through compared to $DWI_{3D}$. Mean SNR and CNR were on $DWI_{3D}$ and $DTI_{6D}$ $44.01{\pm}13.36$, $37.15{\pm}11.44$ (p=0.029) and $18.47{\pm}9.66$, $19.88{\pm}9.20$(p=0.017). The number of lesions were $311{\pm}26.87$, $224.5{\pm}26.16$(p=0.041) on $DTI_{6D}$ and $DWI_{3D}$. Twenty patients were the more detected brain infarction lesion on $DTI_{6D}$. But there is no one the more detected on $DWI_{3D}$. And the more three direction diffusion data could get more information. However, we need to consider about the time consumption compared to DWI.

Physical Vapor Deposition공정 시, Substrate 온도에 따른 X-선 검출용 비정질 셀레늄의 성능평가

  • Kim, Dae-Guk;Gang, Jin-Ho;Kim, Jin-Seon;No, Seong-Jin;Jo, Gyu-Seok;Sin, Jeong-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.210.2-210.2
    • /
    • 2013
  • 현재 국내의 상용화된 디지털 방식 X-선 영상장치에서 간접변환방식은 대부분 CsI를 사용하고 있으며, X-선 흡수에 의해 전기적 신호를 발생시키는 직접변환방식은 Amorphous Selenium(a-Se)을 사용한다. a-Se은 진공 중에 녹는점이 낮아 증착시 substrate의 온도에 따라 민감한 변화를 보인다. 본 연구에서는 간접변환방식에 비해 높은 영상의 질을 획득할 수 있는 직접변환방식의 a-Se기반 X-선 검출기 제작 시 substrate에 인가된 온도에 따른 특성을 연구하여 최적화 된 substrate의 온도를 알고자 한다. 본 실험에서는 glass에 투명한 전극물질인 Indium Tin Oxide (ITO)가 electrode로 형성된 substrate를 사용하였으며 그 상단에 a-Se을 Physical Vapor Deposition (PVD)방식을 거쳐 X-선 검출기 샘플을 제작하였다. PVD 공정 시 네 개의 보트에 a-Se 시료를 각각 100g씩 총 400g을 넣고, $5{\times}10-5Torr$까지 진공도를 낮추었다. 보트의 온도는 $270^{\circ}C$에서 40분 $290^{\circ}C$에서 90분으로 온도를 인가하여 a-Se을 기화시켜 증착하였다. 증착 시 substrate 온도를 각각 $20^{\circ}C$, $40^{\circ}C$, $60^{\circ}C$, $70^{\circ}C$ 네 종류로 나누어 실험을 진행하였다. 끝으로 증착된 a-Se 상단에 Au를 PVD방식으로 electrode를 형성시켜 a-Se기반의 X-선 검출기 샘플 제작을 완료하였다. 제작된 a-Se기반의 X-선 검출기 샘플의 두께는 80에서 $85{\mu}m$로 온도에 따른 차이가 없었다. 이후에 전기적 특성을 평가하기위해 electrometer와 oscilloscope를 이용하여 Dark current와 Sensitivity를 측정하여 Signal to Noise Ratio(SNR)로 도출하였으며 Scanning Electron Microscope(SEM) 표면 uniformity를 관찰하였다. 또한 제작된 a-Se기반 X-선 검출기 샘플의 hole collection 성능을 확인하고자 mobility를 측정하였다. 측정결과 a-Se의 work function을 고려한 $10V/{\mu}m$기준에서 70kV, 100mA, 0.03sec의 조건의 X-선을 조사 하였을 때 Sensitivity는 세 종류의 검출기 샘플이 15nC/mR-cm2에서 18nC/mR-cm2으로 비슷한 양상을 나타내었지만, substrate온도가 $70^{\circ}C$때의 샘플은 10nC/mR-cm2이하로 저감됨을 알 수 있었다. 그리고 substrate온도 $60^{\circ}C$에서 제작된 검출기 샘플의 전기적 특성이 SNR로 환산 시, 15.812로 가장 우수한 전기적 특성을 나타내어 최적화 된 온도임을 알 수 있었다. SEM촬영 시 온도상승에 따라 표면 uniformity가 우수하였으며, Mobility lifetime에서는 $60^{\circ}C$에서 제작된 검출기 샘플이 deep trap 수치가 높아 hole이 $0.04584cm2/V{\cdot}sec$$0.00174cm2/V{\cdot}sec$의 electron보다 26.34배가량 빠른 것을 확인하였다. 본 연구를 통해 a-Se증착 시, substrate에 인가된 온도는 균일한 박막의 형성 및 표면구조에 영향을 미치며 온도가 증가할수록 안정적인 전기적 특성을 나타내지만 $70^{\circ}C$이상일 시, a-Se층의 결정화가 생겨 deep trap을 발생시켜 전기적 특성이 저하됨을 확인 할 수 있었다. 따라서 증착 시의 substrate의 온도 최적화는 a-Se기반 X-선 검출기의 안전성 및 성능향상을 위해 불가피한 요소가 된다고 사료된다.

  • PDF

A feasibility study on new stimulation method in fMRI language examinations using custom designed images (기능적 자기공명영상의 언어기능검사 시 image를 이용한 자극방법의 타당성 연구)

  • Choi, Kwan-Woo;Son, Soon-Yong;Jeong, Mi-Ae;Min, Jung-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5005-5011
    • /
    • 2011
  • The purpose of this work is to know the validity of a new stimulation method in cognitive functional imaging using custom-designed images correspond to words or syllables improving the shortcomings of existing method using text. From March 2011 to May five Subjects in need of language related functional MRI scanning were selected and both of text stimulating method and image stimulating method sacanning were carried out three times each. Using 3.0T Philps MRI machine and Invivo Co's Eloquence system, data acquisition was performed with EPI-BOLD technique. Post processing was performed with SPM 99 while the activated signals were determined within 95 percent confidence level.The number of activation clusters and the activation ratio inside ROI were compared. As as result, all of the subject showed activation inside Broca area but it did not have statistical significance. In conclusion, the image sitimulation method has potential because image itself is a common means of recognition and it can be recognised easily even if there language barrier. This stimulation method can be applied to replacing the exising scanning method especially in the elderly, infants, foerigners who may not fully understand about the examination.

A Study on Maximizing the Matching Ratio of Scintillation Pixels and Photosensors of PET Detector using a Small Number of Photosensors (적은 수의 광센서를 사용한 PET 검출기의 섬광 픽셀과 광센서 매칭 비율의 최대화 연구)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.749-754
    • /
    • 2021
  • In order to maximize the matching ratio between the scintillation pixel and the photosensor of the PET detector using a small number of photosensor, various arrays of scintillation pixels and four photosensors were used. The array of scintillation pixels consisted of six cases from 6 × 6 to 11 × 11. The distance between the photosensors was applied equally to all scintillation pixels, and the arrangement was expanded by reducing the size of scintillation pixel. DETECT2000 capable of light simulation was used to acquire flood images of the designed PET detectors. At the center of each scintillation pixel array, light generated through the interaction between extinction radiation and scintillation pixels was generated, and the light was detected through for four photosensors, and then a flood image was reconstructed. Through the reconstructed flood image, we found the largest arrangement in which all the scintillation pixels can be distinguished. As a result, it was possible to distinguish all the scintillation pixels in the flood image of 8 × 8 scintillation pixel array, and from the 9 × 9 scintillation pixel flood image, the two edge scintillation pixels overlapped and appeared in the image. At this time, the matching ratio between the scintillation pixel and the photosensor was 16:1. When a PET system is constructed using this detector, the number of photosensors used is reduced and the cost of the oveall system is expected to be reduced through the simplification of the signal processing circuit.

Characteristics of Cancer Stem Cells and Immune Checkpoint Inhibition (암줄기세포의 특성 및 면역관문억제)

  • Choi, Sang-Hun;Kim, Hyunggee
    • Journal of Life Science
    • /
    • v.29 no.4
    • /
    • pp.499-508
    • /
    • 2019
  • Cancer stem cells (CSCs), which are primarily responsible for metastasis and recurrence, have self-renewal, differentiation, therapeutic resistance, and tumor formation abilities. Numerous studies have demonstrated the signaling pathways essential for the acquisition and maintenance of CSC characteristics, such as WNT/${\beta}$-catenin, Hedgehog, Notch, B lymphoma Mo-MLV insertion region 1 homolog (BMI1), Bone morphogenetic protein (BMP), and TGF-${\beta}$ signals. However, few therapeutic strategies have been developed that can selectively eliminate CSCs. Recently, neutralizing antibodies against Cytotoxic T-lymphocyte associated protein 4 (CTLA-4) and Programmed cell death protein 1 (PD-1)/Programmed death-ligand 1 (PD-L1), immune checkpoint inhibitors (ICIs), have shown promising outcomes in clinical trials of melanoma, lung cancer, and pancreatic cancer, as well as in hematologic malignancies. ICIs are considered to outperform conventional anticancer drugs by maintaining long-lasting anti-cancer effects, with less severe side effects. Several studies reported that ICIs successfully blocked CSC properties in head and neck squamous carcinomas, melanomas, and breast cancer. Together, these findings suggest that novel and effective anticancer therapeutic modalities using ICIs for selective elimination of CSCs may be developed in the near future. In this review, we highlight the origin and characteristics of CSCs, together with critical signaling pathways. We also describe progress in ICI-mediated anticancer treatment to date and present perspectives on the development of CSC-targeting ICIs.

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.

Design of Two Layer Depth-encoding Detector Module with SiPM for PET (SiPM을 사용한 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 모듈 설계)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.319-324
    • /
    • 2019
  • A depth-encoding detector module with silicon photomultipliers(SiPMs) using two layers of scintillation crystal array was designed, and the position measurement capability was verified using DETECT2000. The depth of interaction of the crystal pixels with the gamma rays was tracked through the image acquired with the combination of surface treatment of the crystal pixels and reflectors. The bottom layer was treated as a reflector except for the optically coupled surfaces, and the crystals of top layer were optically coupled each other except for the outer surfaces so that the light sharing was made easier than the bottom layer. Flood images were obtained through the combination of specular reflectors and random reflectors, grounded and polished surfaces of crystal pixels, and the positions at which layer images were generated were measured and analyzed. The images were reconstructed using the Anger algorithm, whose the SiPM signals were reduced as the 16-channels to 4-channels. In the combination of the grounded surface and all reflectors, the depth positions were discriminated into two layers, whereas it was impossible to separate the two layers in the all polished surface combinations. Therefore, using the combination of grounded surface crystal pixels and reflectors could improve the spatial resolution at the outside of the field of view by measuring the depth position in preclinical positron emission tomography.

Altered Functional Connectivity of the Executive Control Network During Resting State Among Males with Problematic Hypersexual Behavior (문제적 과잉 성 행동자의 휴지기 상태 시 집행 통제 회로의 기능적 연결성 변화)

  • Seok, Ji-Woo
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.35-44
    • /
    • 2019
  • Individuals with problematic hypersexual behavior (PHB) evince the inability to control sexual impulses and arousal. Previous studies have identified that these characteristics are related to structural and functional changes in the brain region responsible for inhibitory functions. However, very little research has been conducted on the functional connectivity of these brain areas during the resting state in individuals with PHB. Therefore, this study used functional magnetic resonance imaging devices with the intention of identifying the deficit of the functional connectivity in the executive control network in individuals with PHB during the resting state. Magnetic resonance imaging data were obtained for 16 individuals with PHB and 19 normal controls with similar demographic characteristics. The areas related to the executive control network (LECN, RECN) were selected as the region of interest, and the correlation coefficient with time series signals between these areas was measured to identify the functional connectivity. Between groups analysis was also used. The results revealed a significant difference in the strength of the functional connectivity of the executive control network between the two groups. In other words, decreased functional connectivity was found between the superior/middle frontal gyrus and the caudate, and between the superior/middle frontal gyrus and the superior parietal gyrus/angular gyrus in individuals with PHB. In addition, these functional Connectivities related to the severity of hypersexual behavior. The findings of this study suggest that the inability to control sexual impulses and arousal in individuals with PHB might be related to the reduced functional connectivity of executive control circuits.

A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication (단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교)

  • Goo, EunHoe
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.1003-1011
    • /
    • 2020
  • This study aims to compare and evaluate the image differences between single and dual sources in applying a technique to reduce metal artifacts using dual energy CT. Discovery CT 256 (GE, USA) as a single source device and Somatom Definition Flash (Siemens Health Care, Forchheim, Germany) as a dual source device. The self-made phantom (pigs with medical titanium screws inserted) was quantitative and qualitatively evaluated under the same conditions by varying the dose under the same conditions using a dual energy CT. The evaluation method was compared by measuring SNR for metal artifacts (scattering, stripe) generated by metal inserts, divided around bones and around tissues. There was a difference in images in the method of reducing metal artifacts between single-source and dual-source devices. In a single source device, the linearized prosthesis by metal implantation showed a greater decrease than the image obtained from a double source device, and the surrounding tissue was well observed without interference from the artifact. In dual-source devices, scattering and stripe artifacts caused by metal inserts decreased more than on a single source device, and signals from adjacent tissues surrounding the metal implant were well observed without diminishing. If the examination is conducted separately between single source and dual source devices depending on whether the area to which the patient is intended to be viewed during the examination is adjacent to the metal insert or the total tissue surrounding the metal insert, it is believed that diagnostic helpful images can be obtained.