• Title/Summary/Keyword: 신호 대 잡음 비율

Search Result 42, Processing Time 0.026 seconds

Sensitivity Study on the Infra-Red Signature of Naval Ship According to the Composition Ratio of Exhaust Plume (폐기가스 조성 비율이 적외선 신호에 미치는 영향 연구)

  • Cho, Yong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.103-110
    • /
    • 2018
  • Infrared signatures emitted from naval ships are mainly classified into internal signatures generated by the internal combustion engine of the ship and external signatures generated from the surface of the ship heated by solar heat. The internal signatures are also affected by the chemical components ($CO_2$, $H_2O$, CO and soot) of the exhaust plumes generated by the gas turbine and diesel engine, which constitute the main propulsion system. Therefore, in this study, the chemical composition ratios of the exhaust plumes generated by the gas turbines and diesel engines installed in domestic naval ships were examined to identify the chemical components and their levels. The influence of the chemical components of the exhaust plumes and their ratios on the infrared signatures of a naval ship was investigated using orthogonal arrays. The infrared signature intensity of the exhaust plumes calculated using infrared signature analysis software was converted to the signal-to-noise ratio to facilitate the analysis. The signature analysis showed that $CO_2$, soot and $H_2O$ are the major components influencing the mid-wave infrared signatures of both the gas turbine and diesel engine. In addition, it was confirmed that $H_2O$ and $CO_2$ are the major components influencing the long-wave infrared signatures.

Endpoint Detection of Speech Signal Using Lyapunov Exponent (리아프노프 지수를 이용한 음성신호 종점 탐색 방법)

  • Zang, Xian;Kim, Jeong-Yeon;Chong, Kil-To
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.28-33
    • /
    • 2009
  • In the research of speech recognition, locating the beginning and end of a speech utterance in a background of noise is of great importance. The conventional methods for speech endpoint detection are based on two simple time-domain measurements-short-time energy, and short-time zero-crossing rate, which couldn't guarantee the precise results if in the low signal-to-noise ratio environments. This paper proposes a novel approach that finds the Lyapunov exponent of time-domain waveform. This proposed method has no use for obtaining the frequency-domain parameters for endpoint detection process, e.g. Mel-Scale Features, which have been introduced in other paper. Accordingly, this algorithm is low complexity and suitable for Digital Isolated Word Recognition System.

[ $^1H$ ] MR Spectroscopy of the Normal Human Brains: Comparison between Signa and Echospeed 1.5 T System (정상 뇌의 수소 자기공명분광 소견: 1.5 T Signa와 Echospeed 자기공명영상기기에서의 비교)

  • Kang Young Hye;Lee Yoon Mi;Park Sun Won;Suh Chang Hae;Lim Myung Kwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.2
    • /
    • pp.79-85
    • /
    • 2004
  • Purpose : To evaluate the usefulness and reproducibility of $^1H$ MRS in different 1.5 T MR machines with different coils to compare the SNR, scan time and the spectral patterns in different brain regions in normal volunteers. Materials and Methods : Localized $^1H$ MR spectroscopy ($^1H$ MRS) was performed in a total of 10 normal volunteers (age; 20-45 years) with spectral parameters adjusted by the autoprescan routine (PROBE package). In all volunteers, MRS was performed in a three times using conventional MRS (Signa Horizon) with 1 channel coil and upgraded MRS (Echospeed plus with EXCITE) with both 1 channel and 8 channel coil. Using these three different machines and coils, SNRs of the spectra in both phantom and volunteers and (pre)scan time of MRS were compared. Two regions of the human brain (basal ganglia and deep white matter) were examined and relative metabolite ratios (NAA/Cr, Cho/Cr, and mI/Cr ratios) were measured in all volunteers. For all spectra, a STEAM localization sequence with three-pulse CHESS $H_2O$ suppression was used, with the following acquisition parameters: TR=3.0/2.0 sec, TE=30 msec, TM=13.7 msec, SW=2500 Hz, SI=2048 pts, AVG : 64/128, and NEX=2/8 (Signa/Echospeed). Results : The SNR was about over $30\%$ higher in Echospeed machine and time for prescan and scan was almost same in different machines and coils. Reliable spectra were obtained on both MRS systems and there were no significant differences in spectral patterns and relative metabolite ratios in two brain regions (p>0.05). Conclusion : Both conventional and new MRI systems are highly reliable and reproducible for $^1H$ MR spectroscopic examinations in human brains and there are no significant differences in applications for $^1H$ MRS between two different MRI systems.

  • PDF

Low-Complexity Speech Enhancement Algorithm Based on IMCRA Algorithm for Hearing Aids (보청기를 위한 IMCRA 기반 저연산 음성 향상 알고리즘)

  • Jeon, Yuyong;Lee, Sangmin
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.363-370
    • /
    • 2017
  • In this paper, we proposed a low-complexity speech enhancement algorithm based on a improved minima controlled recursive averaging (IMCRA) and log minimum mean square error (logMMSE). The IMCRA algorithm track the minima value of input power within buffers in local window and identify the speech presence using ratio between input power and its minima value. In this process, many number of operations are required. To reduce the number of operations of IMCRA algorithm, minima value is tracked using time-varying frequency-dependent smoothing based on speech presence probability. The proposed algorithm enhanced speech quality by 2.778%, 3.481%, 2.980% and 2.162% in 0, 5, 10 and 15dB SNR respectively and reduced computational complexity by average 9.570%.

Development of Optical Pickup for ElectroAcoustic Guitar (일렉트로어쿠스틱 기타용 광 픽업의 개발)

  • Shin, Bong-Hi;Park, Young-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.417-422
    • /
    • 2014
  • A guitar pickup is a transducer that converts string vibration to an electrical signal. The magnetic and piezo pickups are the most commonly used for the respective electric and electroacoustic guitars. The magnetic pickups are prone to magnetic interference between the steel strings and permanent magnets, while the piezo ones are not free from signal inference between the strings. Thus, this paper presents the development of an optical pickup for the electroacoustic guitar. The proposed optical pickup has the top-to-bottom structure. It uses two of Infrared (IR) Light Emitting Diode (LED) and one photodetector. The developed optical pickup is subjected to the evaluation with commonly used piezoelectric pickup. It becomes obvious that SNR with the optical pickup is increased by 45 percent in average, compared with the piezoelectric pickup. It can be concluded that the developed optical pickup has a potential to be applied to the acoustic guitar.

Application of LLR on Cooperative Communications for Wireless Relay Networks (무선 중계 네트워크의 협력 통신 방법에 대한 LLR 적용 연구)

  • Khuong Ho Van;Kong Hyung-Yun;Lee Dong-Un
    • The KIPS Transactions:PartC
    • /
    • v.13C no.5 s.108
    • /
    • pp.601-606
    • /
    • 2006
  • Decode-and-forward cooperative communications protocol (DFP) allows single-antenna users in wireless medium to obtain the powerful benefits of multi-antenna systems without physical antenna arrays. For this protocol, so far the relays have used SNR to evaluate the reliability of the received signal before deciding whether to forward the decoded data so as to prevent their unsuccessful detection. However, SNR only characterizes the long-term statistic of Gaussian noise and thus leading to inaccurate assesment. Therefore, we propose using log-likelihood ratio (LLR) which accounts for the instantaneous noise in the received signal as an alternative to SNR. A variety of simulation results reveal the significant superiority of the SNR-based DFP to the SNR-based DFP regardless of threshold level and relay position under the flat Rayleigh fading channel plus AWGN (Additive White Gaussian Noise).

A New Resource Allocation with Rate Proportionality Constraints in OFDMA Systems (OFDMA 시스템에서 비율적 전송률 분배를 위한 자원 할당)

  • Han, Seung-Youp;Oh, Eun-Sung;Han, Myeong-Su;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.1
    • /
    • pp.59-65
    • /
    • 2008
  • In this paper, a new adaptive resource allocation scheme is proposed in orthogonal frequency-division multiple access(OFDMA) systems with rate proportionality constraints. The problem of maximizing the overall system capacity with constraints on bit error rate, total transmission power and rate-proportionality for user requiring different classes of service is formulated. Since the optimal solution to the constrained fairness problem is extremely complex to obtain, a low-complexity suboptimal algorithm that separates subchannel allocation and power allocation is proposed. Firstly, the number of subchannels to be assigned to each user is determined based on the users' average signal-to-noise ratio and rate-proportion. Subchannels are subsequently distributed according to the modified max-min criterion. Lastly, based on the subchannel allocation, the optimal power allocation by solving the Language dual problem is proposed. Additionally, in order to reduce the computational complexity, iterative rate proportionality tracking algorithm is proposed for maximizing the capacity together with maintaining the rate proportionality constraint.

PET/CT SUV Ratios in an Anthropomorphic Torso Phantom (의인화몸통팬텀에서 PET/CT SUV 비율)

  • Yeon, Joon-Ho;Hong, Gun-Chul;Kang, Byung-Hyun;Sin, Ye-Ji;Oh, Uk-Jin;Yoon, Hye-Ran;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.23-29
    • /
    • 2020
  • The standard uptake values (SUVs) strongly depend on positron emission tomographs (PETs) and image reconstruction methods. Various image reconstruction algorithms in GE Discovery MIDR (DMIDR) and Discovery Ste (DSte) installed at Department of Nuclear Medicine, Seoul Samsung Medical Center were applied to measure the SUVs in an anthropomorphic torso phantom. The measured SUVs in the heart, liver, and background were compared to the actual SUVs. Applied image reconstruction algorithms were VPFX-S (TOF+PSF), QCFX-S-350 (Q.Clear+TOF+PSF), QCFX-S-50, VPHD-S (OSEM+PSF) for DMIDR, and VUE Point (OSEM) and FORE-FBP for DSte. To reduce the radiation exposure to radiation technologists, only the small amount of radiation source 18F-FDG was mixed with the distilled water: 2.28 MBq in the 52.5 ml heart, 20.3 MBq in the 1,290 ml liver and 45.7 MBq for the 9,590 ml in the background region. SUV values in the heart with the algorithms of VPFX-S, QCFX-S-350, QCFX-S-50, VPHD-S, VUE Point, and FOR-FBP were 27.1, 28.0, 27.1, 26.5, 8.0, and 7.4 with the expected SUV of 5.9, and in the background 4.2, 4.1, 4.2, 4.1, 1.1, and 1.2 with the expected SUV of 0.8, respectively. Although the SUVs in each region were different for the six reconstruction algorithms in two PET/CTs, the SUV ratios between heart and background were found to be relatively consistent; 6.5, 6.8, 6.5, 6.5, 7.3, and 6.2 for the six reconstruction algorithms with the expected ratio of 7.8, respectively. Mean SNRs (Signal to Noise Ratios) in the heart were 8.3, 12.8, 8.3, 8.4, 17.2, and 16.6, respectively. In conclusion, the performance of PETs may be checked by using with the SUV ratios between two regions and a relatively small amount of radioactivity.

Multi-Component Relaxation Study of Human Brain Using Relaxographic Analysis (Relaxographic 분석법을 이용한 뇌의 다중 자기이완특성에 관한 연구)

  • Yongmin Chang;Bong Soo Han;Bong Seok Kang;Kyungnyeo Jeon;Kyungsoo Bae;Yong-Sun Kim;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.120-128
    • /
    • 2002
  • Purpose : To demonstrate that the relaxographic method provides additional information such as the distribution of relaxation times and water content which are poentially applicable to clinical medicine. Materials and Methods : First, the computer simulation was performed with the generated relaxation data to verify the accuracy and reliabilility of the relaxographic method (CONTINI). Secondly, in or der to see how well the CONTIN quantifies and resolves the two different ${T_1}$ environments, we calculated the oil to water peak area ratios and identified peak positions of ${T_1}-distribution$ curve of the phantom solutions, which consist of four centrifugal tubes (10 ml) filled with the compounds of 0, 10, 20, 30% of corn oil and distilled water, using CONTIN. Finally, inversion recovery MR images for a volunteer are acquired for each TI ranged from 40 to 1160 msec with TR/TE=2200/20 msec. From the 3 different ROIs (GM, WM, CSF), CONTIN analysis was performed to obtain the ${T_1}$-distribution curves, which gave peak positions and peak area of each ROI location. Results : The simulation result shows that the errors of peak positions were less in the higher peak (centered ${T_1}=600$ msec) than in the lower peak (centered ${T_1}=150$ msec) for all SNR but the errors of peak areas were larger in the higher peak than in the lower peak. The CONTIN analysis of the measured relaxation data of phantoms revealed two peaks between 20 and 60 msec and between 500 and 700 msec. The analysis gives the peak area ratio as oil 10%: oil 20%: oil 30% = 1:1.3:1.9, which is different from the exact ratio, 1:2:3. For human brain, in ROI 3 (CSF), only one component of -distributions was observed whereas in ROI 1(GM) and in ROI 2 (WM) we observed two components of ${T_1}-distribution$. For the WM and CSF there was great agreement between the observed ${T_1}-relaxation$ times and the reported values. Conclusion : we demonstrated that the relaxographic method provided additional information such as the distribution of relaxation times and water content, which were not available in the routine relaxometry and ${T_1}/{T_2}$ mapping techniques. In addition, these additional information provided by relaxographic analysis may have clinical importance.

  • PDF

A 1.2V 90dB CIFB Sigma-Delta Analog Modulator for Low-power Sensor Interface (저전력 센서 인터페이스를 위한 1.2V 90dB CIFB 시그마-델타 아날로그 모듈레이터)

  • Park, Jin-Woo;Jang, Young-Chan
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.786-792
    • /
    • 2018
  • A third-order sigma-delta modulator with the architecture of cascade of integrator feedback (CIFB) is proposed for an analog-digital converter used in low-power sensor interfaces. It consists of three switched-capacitor integrators using a gain-enhanced current-mirror-based amplifier, a single-bit comparator, and a non-overlapped clock generator. The proposed sigma-delta analog modulator with over-sampling ratio of 160 and maximum SNR of 90.45 dB is implemented using $0.11-{\mu}m$ CMOS process with 1.2-V supply voltage. The area and power consumption of the sigma-delta analog modulator are $0.145mm^2$ and $341{\mu}W$, respectively.